Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Med Imaging ; 20(1): 52, 2020 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-32429910

RESUMO

BACKGROUND: In the last years, Selective Internal Radiation Therapy (SIRT), using biocompatible Yttrium-90 (90Y) labeled microspheres have emerged for the treatment of malignant hepatic tumors. Unfortunately, a significant part of 90Y-labeled microspheres may shunt to the lungs after intraarterial injection. It can be predictable by infusing technetium-99 m-labeled macro-aggregated albumin particles through a catheter placed in the proper hepatic artery depending on the lobe to be treated with performing a quantitative lung scintigraphy. Radiation pneumonitis (RP) can occur 1 to 6 months after the therapy, which is a rare but severe complication of SIRT. Prompt timing of steroid treatment is important due to its high mortality rate. On the other hand, pulmonary diffusion capacity measured by carbon monoxide (DLCO) is an excellent way to measure the diffusing capacity because carbon monoxide is present in minimal amount in venous blood and binds to hemoglobin in the same manner as oxygen. Some authors reported that the most consistent changes after radiation therapy (RT) are recorded with this quantitative reproducible test. The relationship between the proportional reductions in DLCO and the severity of RP developing after this therapy may prove to be clinically significant. CASE PRESENTATION: We herein present a patient who developed RP after SIRT that could be quantified using DLCO. To the best of our knowledge, this case is the first who developed unexpected RP after SIRT with significant decrease in DLCO with internal radiation exposure. CONCLUSIONS: RP is a very rare complication and may lead to a fatal outcome. Decline in DLCO could be a valuable parameter for follow-up and to identify potential candidates for RP and could be also another trigger for administration of steroid therapy with prompt timing in this patient group.


Assuntos
Capacidade de Difusão Pulmonar/métodos , Pneumonite por Radiação/diagnóstico , Radioisótopos de Ítrio/efeitos adversos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/virologia , Hepatite B/radioterapia , Humanos , Infusões Intra-Arteriais , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/virologia , Masculino , Pessoa de Meia-Idade , Radioisótopos de Ítrio/administração & dosagem
2.
AJR Am J Roentgenol ; 208(6): 1400-1409, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28267361

RESUMO

OBJECTIVE: The purpose of this study is to assess the utility of a volume navigation technique (VNT) for ultrasound-guided biopsy of MRI-detected, but sonographically ambiguous or occult, breast lesions. SUBJECTS AND METHODS: Within a recruitment period of 13 months (January 1, 2014, through February 1, 2015), 22 patients with 26 BI-RADS category 4 or 5 lesions that were detected at MRI but missed at second-look ultrasound were reimaged using a rapid sequence and a flexible body coil in a 3-T MRI scanner. Patients were supine, with three skin markers placed on the breasts. MRI volume data were coregistered to real-time ultrasound in a dedicated platform, and MRI-detected lesions (six masses, 11 nonmass enhancements, eight foci, and one architectural distortion) were sought using VNT-guided ultrasound. Five needle biopsy specimens were obtained either from each sonographically detected lesion (n = 11) or from VNT-guided sonographically localized breast volume corresponding to the MRI-detected, but still ultrasound-occult, lesions (n = 15). RESULTS: Histopathologic analysis revealed 18 benign and six malignant lesions. The remaining two lesions, both of which appeared as masses at MRI, were high risk and were upgraded to carcinoma after excisional biopsy. All malignant lesions underwent curative surgery; the final histopathologic diagnoses remained unchanged. Of the six malignant lesions, one was a mass, three were nonmass enhancements, and two were enhancing foci at MRI. Three malignant lesions were occult at ultrasound, and three were discerned as subtle hypoechoic changes. No benign lesion was sonographically visualized as a mass, and none progressed, with 56% disappearing at MRI performed during the follow-up period (mean, 14 months). CONCLUSION: Coregistration of MRI and real-time ultrasound enables sonographic localization of breast lesions detected at MRI only. VNT is a feasible alternative to MRI-guided biopsy of ultrasound-occult breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Aumento da Imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Adulto , Idoso , Reações Falso-Negativas , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Carga Tumoral
3.
Acta Radiol ; 58(7): 849-855, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27799571

RESUMO

Background Pelvic congestion syndrome (PCS) is a commonly overlooked condition which is a potential cause of chronic pelvic pain. Magnetic resonance imaging (MRI) of the sacroiliac joint (SIJ) may demonstrate unexpected conditions that can mimic sacroiliitis (SI). Awareness of MRI-defined pelvic venous congestion (PVC) may help in identifying PCS, where vascular abnormality may be the sole manifestation of SIJ pain. Purpose To detect incidental MRI-defined PVC in patients who underwent SIJ-MRI for presumed SI and define the variance of its incidence. Material and Methods A total of 870 women who underwent SIJ-MRI were retrospectively evaluated. Incidental findings of PVC and other genitourinary and musculoskeletal system disorders were documented. Results Of the 774 included patients, 37% demonstrated incidentally detected imaging findings related to the genitourinary system, musculoskeletal system, and PVC. The prevalence of MRI-defined PVC signs was higher in patients without SI than with SI. The prevalence of musculoskeletal disorders was higher in patients with SI whereas prevalence for genitourinary disorders was similar. Binary logistic regression analysis revealed a statistically significant correlation between SI-PVC and SI-genitourinary disorders but not between SI-musculoskeletal disorders pairs ( P = 0.001, 0.001, and 0.057 > 0.05). The probability of observing SI in SIJ-MRI is positively correlated with the absence of PVC or genitourinary disorders. Conclusion Patients who underwent MRI for presumed SI demonstrated incidental PVC as well as other genitourinary and musculoskeletal findings. An awareness of these imaging findings can help identify PVC and may draw clinicians' attention to the possibility of PCS.


Assuntos
Hiperemia/complicações , Hiperemia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Articulação Sacroilíaca/diagnóstico por imagem , Sacroileíte/complicações , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Pelve , Estudos Retrospectivos , Adulto Jovem
4.
Acta Radiol ; 58(3): 286-291, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27235454

RESUMO

Background Ultrasound-guided fine needle aspiration biopsy (FNAB) of thyroid nodules, though the most accurate method to rule out malignancy, still has an inherent risk of yielding non-diagnostic specimens despite immediate assessment of specimen adequacy by an on-site cytopathologist. Purpose To evaluate the effects of nodule volume and extent of cystic degeneration on total biopsy time and number of aspirations required for obtaining an adequate specimen. Material and Methods A total of 510 patients underwent FNAB by a single radiologist accompanied by a cytopathologist who immediately assessed each sample for specimen adequacy. All sampled nodules were single and had one maximum diameter > 10 mm. Nodule volumes and cystic degeneration ratios were calculated prior to the intervention. Aspirations were repeated until the cytological material was deemed adequate by the cytopathologist; the number of aspirations and total biopsy time were then recorded. Results Nodule volumes did not have significant effect on neither number of aspirations necessary for achieving specimen adequacy ( P > 0.05) nor total biopsy time (r = -0.148 with P = 0.001). Predominantly cystic nodules, compared to predominantly solid nodules, required more sampling per nodule (4.58 ± 1.11 vs. 3.44 ± 1.19 aspirations, P = 0.001) and longer total biopsy time (16.40 ± 6.19 vs. 11.15 ± 6.18 min, P = 0.001). Conclusion Predominantly cystic nodules require allocation of more time for biopsy. To ensure specimen adequacy when immediate specimen evaluation by an on-site cytopathologist is not possible, four samples from predominantly solid nodules and five passes through predominantly cystic nodules are required.


Assuntos
Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adulto Jovem
5.
AJR Am J Roentgenol ; 206(1): 217-25, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26700355

RESUMO

OBJECTIVE: The objective of this study was to evaluate the accuracy of the volume navigation technique for combining real-time ultrasound and contrast-enhanced MRI (CE-MRI) of breast lesions. SUBJECTS AND METHODS: Thirty-eight women with single breast lesions underwent 3-T MRI. A 3.5-minute CE-MRI sequence was used, as was a flexible body coil. Patients underwent imaging in the supine position, with three markers placed on their breasts. Real-time sonographic images were coregistered to the preloaded breast CE-MRI volume by coupling skin markers, with the use of an electromagnetic transmitter positioned next to the subjects. The transmitter detected the spatial positions of the two electromagnetic sensors mounted on the transducer bracket. After this fusion process in 3D space was completed, divergences in the location of the center of each lesion on CE-MRI and ultrasound images were analyzed. RESULTS: The mean lesion size was 17.4 mm on ultrasound and 17.9 mm on MRI, whereas the mean (± SD) misalignment of the lesion centers on CE-MRI and ultrasound was 3.9 ± 2.5 mm on the x-axis (mediolateral view), 3.6 ± 2.7 mm on the y-axis (anteroposterior view), and 4.3 ± 2.6 mm on the z-axis (craniocaudal view). No lesion had a misalignment greater than 10 mm on any of three axes. The accuracy of volume navigation was independent of patient age and the lesion size, location, and histopathologic findings (p > 0.05). Intermediate lesions, which had a depth of center of 11-20 mm on ultrasound had a mean misalignment of 2.6 ± 1.9 mm, compared with 5.5 ± 2.2 mm for deep lesions, which had a depth of center greater than 20 mm (p = 0.049). CONCLUSION: The volume navigation technique is an accurate method for coregistration of CE-MRI and sonographic images, enabling lesion localization within a limited volume.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Pessoa de Meia-Idade
6.
Acta Radiol ; 57(11): 1304-1309, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26019241

RESUMO

Background An important difficulty regarding the Breast Imaging Reporting and Data System (BI-RADS) category 3 assessment is the need for extensive diagnostic workup and an additional 6-month follow-up study. Purpose To evaluate the feasibility of the BI-RADS category 3 assessments at opportunistic screening. Material and Methods Mammography charts of 9062 screening patients in a major teaching hospital situated in an urban setting of a developing country were evaluated retrospectively (1997-2010). BI-RADS category 3 patients, called for a 6-month follow-up, which comprised a single-view spot or magnification mammogram. The length of follow-up period, compliance to periodic mammographic surveillance, cancer detection rate, and negative predictive values of category 3 assessments were calculated. Results Of the screened population, 9.2% were assigned BI-RADS category 3, and 31.2% of these cases were lost to follow-up. The mean follow-up period for 606 patients was 36.9 months. The negative predictive values for 6-month, 12-month, and final control studies were 90.9%, 87.5%, and 100%, respectively. Patient compliance for 6 months, 12 months, and any control evaluations beyond 12 months was low (50.0%, 29.8%, and 47.5%, respectively). Cancer detection rate was 0.8%. Conclusion Results of the study supports the feasibility of the BI-RADS category 3 assessments at opportunistic screening without any additional diagnostic workup. The practice of category 3 assessment following screening mammograms may be a more cost-effective method for developing countries with high recall rates and low resources in eliminating the maximum risk with minimum cost within the limits of available resources.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Competência Clínica/estatística & dados numéricos , Países em Desenvolvimento/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/classificação , Feminino , Humanos , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Turquia/epidemiologia
7.
Acta Neurochir (Wien) ; 158(8): 1545-53, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27250849

RESUMO

BACKGROUND: Stent-assisted coiling using low-profile, self-expandable and retrievable stents is a valid option in endovascular treatment of challenging intracranial aneurysms. This study aims to evaluate the feasibility and efficacy of ACCLINO 1.9 F and ACCLINO Flex stent systems, designed for use as adjunctive products in coil embolization of intracranial aneurysms. METHODS: Case files of 47 patients, and 52 aneurysms in total, treated with at least one ACCLINO 1.9 F or ACCLINO Flex stent were retrospectively evaluated. Technical success, complications, and angiographic outcomes were assessed based on immediate post-procedural controls along with 6th and 12th month angiograms. RESULTS: Mechanical untoward event rate, including asymptomatic complications, is 9.6 % (five out of 52 aneurysms). Failed dual-stenting attempt rate is 15.4 % (two out of 13). Overall procedure-related morbidity is 4.2 % with no neurologic sequelae. Initial occlusion rate is 90.4 % (47 aneurysms). One patient had residual filling in the aneurysm neck, which was stable throughout follow-up. The remaining four cases had spontaneous follow-up occlusion. Recanalization rate at 6th month is 2.1 % with one aneurysm requiring retreatment. One patient was lost to follow-up. There is no mortality associated with treatment. CONCLUSIONS: Stent-assisted coil embolization with ACCLINO stents in single or dual configurations is a feasible treatment option for challenging intracranial aneurysms. Follow-up results are encouraging; techniques were effective in complex cases and there were no clinically significant adverse outcomes.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Humanos , Resultado do Tratamento
8.
Acta Radiol ; 56(10): 1203-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25344502

RESUMO

BACKGROUND: A fine needle aspiration biopsy (FNAB) of thyroid nodules - the least invasive and most accurate method used to investigate malignant lesions - may yield non-diagnostic specimens even under ultrasonographic guidance. PURPOSE: To evaluate the effects of thyroid nodule volume and extent of cystic degeneration on both the non-diagnostic specimen ratio as well as cytopathologist's definitive cytological diagnosis time. MATERIAL AND METHODS: In this single center study, FNAB was performed on 505 patients with single thyroid nodules greater than 10 mm. Nodule volume was calculated prior to FNAB and cystic degeneration ratio was recorded. All biopsies were performed by a single radiologist who also prepared specimen slides. Specimen adequacy and final diagnosis were made in the pathology laboratory by a single-blinded cytopathologist based on the Bethesda system. Definitive cytological diagnosis time was recorded upon reaching a definitive diagnosis. RESULTS: The specimen adequacy ratio was 85.3%. The mean nodule volume of adequate specimens was larger than those of non-diagnostic samples (6.00 mL vs. 3.05 mL; P = 0.001). There was no correlation between nodule volume and cytopathologist's definitive cytological diagnosis time (r = 0.042). Biopsy of predominantly solid nodules yielded better specimen adequacy ratios compared to predominantly cystic nodules (87.8% vs. 75.3%; P = 0.028). Definitive cytological diagnosis times were longer in predominantly cystic nodules compared to predominantly solid nodules (376 s vs. 294 s; P = 0.019). CONCLUSION: Predominantly cystic nodules are likely to benefit from repeated nodular sampling until the specimen is declared adequate by an on-site cytopathologist. If a cytopathologist is not available, obtaining more specimens per nodule may achieve desired adequacy ratios.


Assuntos
Biópsia por Agulha Fina , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Diagn Interv Radiol ; 29(2): 350-358, 2023 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-36988000

RESUMO

PURPOSE: This study aims to evaluate the safety and efficacy of flow diverters (FDs) in the treatment of middle cerebral artery (MCA) aneurysms and share the follow-up (F/U) results. METHODS: The treatment and F/U results of 76 MCA aneurysms treated with the flow re-direction endoluminal device (FRED), FRED Jr., and pipeline embolization device (PED) FD stents were evaluated retrospectively. The aneurysm occlusion rates were compared between FDs, and the integrated and jailed branches were evaluated through follow-ups. The oversizing of the stent was compared between occluded/non-occluded aneurysms and integrated branches. RESULTS: The mean F/U duration was 32 ± 6.3 months, and the mean aneurysm diameter was 4.45 mm. A total of 61 (80.3%) aneurysms were wide-necked; 73 (96.1%) were saccular; 52 (68.4%) were located at the M1 segment; and 36 (45.6%) FREDs, 23 (29.1%) FRED Jr.s, and 19 (24.1%) PEDs were used for treatment. The overall occlusion rates for the 6-, 12-, 24-, 36-, and 60-month digital subtraction angiographies were 43.8%, 63.5%, 73.3%, 85.7%, and 87.5% respectively. The last F/U occlusion rates were 67.6% for FRED, 66.7% for PED, and 60.6% for FRED Jr. (P = 0.863). An integrated branch was covered with an FD during the treatment of 63 (82.8%) aneurysms. A total of six (10%) of the integrated branches were occluded without any symptoms at the last F/U appointment. The median oversizing was 0.45 (0-1.30) for occluded aneurysms, and 0.50 (0-1.40) for non-occluded aneurysms (P = 0.323). The median oversizing was 0.70 (0.45-1.10) in occluded integrated branches and 0.50 (0-1.40) in non-occluded branches (P = 0.131). In-stent stenosis was seen in 22 (30.1%) of the stents at the 6-month F/U and in only 2 (4.7%) at the 24-month F/U. Thus, none of the patients had any neurological deficits because of the in-stent stenosis. Severe in-stent stenosis was seen in two stents. CONCLUSION: MCA aneurysms tend to be complex, with integrated branches and potentially wide necks. FD stents are safe and effective in the treatment of MCA aneurysms, and the patency of the side and jailed branches is preserved in most cases. Higher occlusion and lower in-stent stenosis rates are seen with longer F/U durations.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Doenças Vasculares , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Constrição Patológica/terapia , Embolização Terapêutica/métodos , Stents , Doenças Vasculares/terapia , Procedimentos Endovasculares/métodos , Angiografia Cerebral
10.
Diagn Interv Radiol ; 28(6): 621-626, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36550764

RESUMO

PURPOSE We aimed to demonstrate the feasibility of ultrasound (US)-guided retrograde tibial access through chronically occluded tibial arteries as a bailout endovascular recanalization procedure in patients with critical limb ischemia (CLI). METHODS Fifty-one CLI patients with failed conventional antegrade tibiopedal recanalization required retrograde tibiopedal access in the same session. In all of these patients, the target tibial artery was chronically occluded in at least the distal half of the cruris. Access attempts were made under real-time US by a single operator experienced in image-guided vascular access procedures. Fluoroscopy was used only as an adjunct during advancement of a 0.018 inch guidewire. If access to the artery was successful by the retrograde route, the occluded artery was usually predilated with a 2 mm balloon, and the standard endovascular treatment was mostly performed through the antegrade route. RESULTS Patients had athereosclerosis (n=35) or Buerger's disease (n=32) and presented with Rutherford category IV and category V. Successful placement of a guidewire in the occluded artery lumen was achieved in 81% of all patients, whereas, treatment success, i.e. angiographic demonstration of in-line flow at the end of procedure, was achieved in 49%. No significant procedure-related complications were observed. Of 33 limbs with initially successful endovascular treatment, 6 required minor and 1 required major amputation during follow-up. CONCLUSION US-guided retrograde access through completely occluded tibial arteries is difficult but feasible. Half of the tibial arteries that could not be recanalized otherwise were converted to successful recanalization by this method.


Assuntos
Arteriopatias Oclusivas , Procedimentos Endovasculares , Doença Arterial Periférica , Humanos , Artérias da Tíbia/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Resultado do Tratamento , Arteriopatias Oclusivas/terapia , Ultrassonografia de Intervenção , Procedimentos Endovasculares/métodos , Doença Arterial Periférica/terapia , Estudos Retrospectivos , Grau de Desobstrução Vascular , Salvamento de Membro
11.
Interv Neuroradiol ; 28(3): 302-310, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34515551

RESUMO

OBJECTIVE: This study aims to compare the efficacy, safety, and long-term outcomes of two flow diverters, i.e., pipeline embolization device and flow re-direction endoluminal device, in the treatment of distal carotid aneurysms. METHODS: A total of 138 patients with 175 aneurysms were included from February 2012 to September 2019. Ninety-nine aneurysms were treated with flow re-direction endoluminal device and 76 with pipeline embolization device. Angiographic follow-ups were at the 6th, 12th, 24th, 36th, and 60th months; the O'Kelly-Marotta grading scale was used to assess aneurysms occlusion. Outcomes of two devices were compared; possible associations regarding patient characteristics, aneurysm properties, treatment details, and adverse events were evaluated. RESULTS: The mean follow-up period was 33 months, with 10 patients lost to follow-up. Occlusion rates at the 6th and 12th months and during the last follow-up were similar for flow re-direction endoluminal device (81%, 84%, and 90%) and pipeline embolization device (82%, 85%, and 93%). Occlusion rates were also similar after stand-alone use without coiling. There was no significant difference regarding adverse event rates with a 10.9% overall complication rate, 3.6% mortality, and 0.7% permanent morbidity. All the mortality and morbidity were related to hemorrhagic complications. Device deployment failure was observed with five flow re-direction endoluminal devices and two pipeline embolization devices, whereas two severe in-stent stenoses occurred with each device. CONCLUSIONS: Both flow re-direction endoluminal device and pipeline embolization device are feasible and effective in flow diversion of distal internal carotid artery aneurysms, with similar adverse events rates and aneurysm occlusion success. Aneurysm occlusion rates increase with time, while the presence of an integrated branch significantly decreases treatment success.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Prótese Vascular , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
12.
Curr Med Imaging ; 17(7): 897-903, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33966622

RESUMO

BACKGROUND: Greater Saphenous Vein (GSV) courses within saphenous compartment, an adipose-filled space bound by fasciae provides structural support. Ultrasound Shear-Wave Elastography (SWE) provides objective and quantitative data on tissue shear elasticity modulus. OBJECTIVE: This study aims to analyze possible associations between early stage GSV insufficiency and saphenous intracompartmental SWE measurements. METHODS: Two-hundred consecutive patients, ages 22 to 81 (mean=44.3) years, with venous insufficiency symptoms underwent Doppler and SWE examinations. Patients had no visible or palpable sign of venous disease or had telangiectasia and reticular veins only. Analyses regarding patient age, gender, presence of venous insufficiency of GSV proper and intracompartmental connective tissue elasticity were performed. RESULTS: Ninety-six patients had Doppler evidence for either bilateral or unilateral insufficiency of GSV proper at mid-thigh level. Intracompartmental elasticity of patients with venous insufficiency (mean=4.36±2.24 kilopascals; range 1.55 to 10.44 kPa) did not differ significantly from those with normal veins (mean=4.82±2.61 kPa; range 2.20 to 12.65 kPa) (p=0.231). No threshold for predicting the presence of venous insufficiency could be determined. Neither were there any correlations between age, gender and intracompartmental elasticity. In patients with unilateral insufficiency, however, elastography values around insufficient veins were significantly lower compared to contralateral normal GSV (p<0.001). CONCLUSION: Many intrinsic and patient factors affect intracompartmental connective tissue elastography measurements; thus, cut-off values obtained from specific populations have limited generalizability. Nevertheless, statistically significant intrapatient differences of intracompartmental elasticity among diseased and normal saphenous veins indicate that lack of elastic support from surrounding connective tissues contributes to venous insufficiency in early stages.


Assuntos
Técnicas de Imagem por Elasticidade , Insuficiência Venosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Tecido Conjuntivo/diagnóstico por imagem , Elasticidade , Humanos , Pessoa de Meia-Idade , Veia Safena/diagnóstico por imagem , Insuficiência Venosa/diagnóstico por imagem , Adulto Jovem
13.
Clin Nucl Med ; 46(2): e94-e96, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33181739

RESUMO

ABSTRACT: FDG PET/CT is used in the diagnosis and follow-up of various malignant tumors and changes patient management in routine clinical practice. However, inflammatory, infectious, physiological, and technical causes and benign pathological conditions may lead to false-positive FDG uptake. We report a case of a 59-year-old man who was considered having a false-positive FDG-PET pulmonary nodular lesion in favor of metastasis, which was formed by the use of hemostatic powder.


Assuntos
Fluordesoxiglucose F18 , Hemostáticos/farmacologia , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Reações Falso-Positivas , Humanos , Masculino , Pessoa de Meia-Idade , Pós
14.
Turk Gogus Kalp Damar Cerrahisi Derg ; 28(3): 474-479, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32953210

RESUMO

BACKGROUND: This study aims to identify specific segmental distribution patterns of lower extremity chronic venous disease based on latent class analysis of Doppler mapping results. METHODS: A total of 1,871 lower extremities of 1,218 treatment-naïve patients (536 males, 682 females; mean age 45.4 years; range, 21 to 87 years) with chronic venous disease referred for Doppler examination between September 2009 and August 2018 were included. Refluxing superficial venous segments of the lower extremities were mapped and recorded in database in 10 distinct anatomic locations as follows: saphenofemoral junction and proximal greater saphenous vein, mid and distal thigh greater saphenous vein, anterior and posterior accessory saphenous veins, proximal and distal calf greater saphenous vein, saphenopopliteal junction and proximal lesser saphenous vein, distal lesser saphenous vein, and intersaphenous veins including Giacomini"s vein. Repeated examinations were excluded. The latent class analysis was applied to identify any possible anatomic distribution patterns of chronic venous disease. RESULTS: Bayesian information criteria revealed three latent class models fit for refluxing segment distribution as follows: 58.2% (n=1,089) were above-the-knee greater saphenous vein segments including saphenofemoral junction (pattern 1); 29.3% (n=548) were below-theknee greater saphenous vein segments (pattern 2); and 12.5% (n=234) were lesser saphenous vein segments and intersaphenous veins including Giacomini"s vein (pattern 3). There was no age- or sex-specific differences in the chronic venous disease distribution patterns. CONCLUSION: The latent class analysis, by identifying previously unseen subgroups within the sampled population, provides a new approach to classification of reflux patterns in chronic venous disease. Identification of latent classes may provide understanding of different pathophysiological bases of venous reflux and more optimal planning for interventions.

15.
Cardiovasc Intervent Radiol ; 41(1): 43-48, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29038874

RESUMO

PURPOSE: To demonstrate feasibility and safety of ultrasound-guided popliteal sciatic nerve block for providing analgesia during urgent endovascular treatment of critical limb ischemia with resting pain. MATERIALS AND METHODS: Ultrasound-guided popliteal sciatic blocks were performed by an interventional radiologist in angiography suite immediately prior to commencement of urgent endovascular treatment of 30 critical limb ischemia patients. Subjective pain levels prior to and following sciatic block were assessed using the visual analog scale (VAS). Need for any supplemental anxiolytics or analgesics during treatment was recorded. Post-procedural evaluation of patient and operator satisfaction levels regarding the intervention was also documented. RESULTS: Ultrasound-guided sciatic block provided adequate analgesia in all patients; VAS scores were 0 (no pain) in 87% and 1-3 (mild to annoying pain) in 13%. Two patients required anxiolytic premedication. Additional analgesia was not required during course of endovascular treatment of any patients. Time necessary to perform sciatic block ranged 3-9 (mean 5.9 ± 1.3) min. Median number of needle attempts was 1 (range 1-3). Onset of satisfactory block ranged from 5 to 20 min (mean 9.4 ± 2.6 min). Mean treatment time was 102.2 ± 36.7 min, and balloon time was 22.4 ± 6.1 min. Patient and operator satisfaction with pain control were very good in all cases. There were no procedure-related complications. CONCLUSIONS: Ultrasound-guided popliteal sciatic block is a feasible and safe alternative for providing adequate analgesia during urgent endovascular treatment of critical limb ischemia with resting pain. LEVEL OF EVIDENCE: Level 4, case series.


Assuntos
Analgesia/métodos , Procedimentos Endovasculares , Isquemia/terapia , Bloqueio Nervoso/métodos , Dor/tratamento farmacológico , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Extremidades/irrigação sanguínea , Estudos de Viabilidade , Feminino , Humanos , Isquemia/complicações , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Manejo da Dor/métodos , Estudos Prospectivos , Nervo Isquiático/diagnóstico por imagem , Resultado do Tratamento
16.
Phlebology ; 33(7): 470-474, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28728467

RESUMO

Purpose To elaborate on a planar anatomic variant of great saphenous vein as a potential therapeutic pitfall in the treatment of venous reflux. Materials and methods Lower extremity veins in 568 limbs with great saphenous vein insufficiency were sonographically mapped. A rather overlooked variation, the saphenous bow, was studied with emphasis on anatomic clarification and its involvement in venous insufficiency. Results This variation, observed in 5.1% (n = 29) of limbs, comprised two segments; one uninterrupted great saphenous vein proper coursing throughout saphenous compartment and one extra-compartmental segment originating distally from and proximally fusing with it. Venous arch remains within compartment only briefly during take-off and re-entry. Extra-compartmental venous arch had reflux either alone (10.3%) or together with intra-compartmental segment (75.9%). Conclusion This variation, part of saphenous segmental aplasia/hypoplasia complex, is associated with venous insufficiency. Meticulous mapping of great saphenous vein territory and identification of such variants during planning stage is indispensable for optimal clinical outcomes of treatment.


Assuntos
Veia Safena , Varizes , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Veia Safena/patologia , Veia Safena/fisiopatologia , Varizes/patologia , Varizes/fisiopatologia , Varizes/terapia
17.
Ulus Travma Acil Cerrahi Derg ; 23(6): 489-494, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29115651

RESUMO

BACKGROUND: Primer epiploic appendagitis (PEA) is an uncommon condition. METHODS: We retrospectively reviewed the clinical records and computed tomography (CT) findings of 45 patients with PEA. RESULTS: On the basis of physical examination and pain localization, presumptive clinical diagnosis was acute appendicitis (n=13), acute cholecystitis (n=2), acute diverticulitis (n=19), renal colic (n=7) and ovarian pathology (n=4). CONCLUSION: Although it has no characteristic clinical and laboratory features, CT is the best modality for accurate diagnosis of PEA.


Assuntos
Doenças do Colo , Doenças Retais , Tomografia Computadorizada por Raios X , Apendicite , Doenças do Colo/diagnóstico , Doenças do Colo/diagnóstico por imagem , Doenças do Colo/fisiopatologia , Diagnóstico Diferencial , Diverticulite , Humanos , Doenças Retais/diagnóstico , Doenças Retais/diagnóstico por imagem , Doenças Retais/fisiopatologia , Estudos Retrospectivos
18.
Acad Radiol ; 22(10): 1236-41, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26254544

RESUMO

RATIONALE AND OBJECTIVES: The aim of the study was to ascertain the learning curves for the radiology residents when first introduced to an anatomic structure in magnetic resonance images (MRI) to which they have not been previously exposed to. MATERIALS AND METHODS: The iliolumbar ligament is a good marker for testing learning curves of radiology residents because the ligament is not part of a routine lumbar MRI reporting and has high variability in detection. Four radiologists, three residents without previous training and one mentor, studied standard axial T1- and T2-weighted images of routine lumbar MRI examinations. Radiologists had to define iliolumbar ligament while blinded to each other's findings. Interobserver agreement analyses, namely Cohen and Fleiss κ statistics, were performed for groups of 20 cases to evaluate the self-learning curve of radiology residents. RESULTS: Mean κ values of resident-mentor pairs were 0.431, 0.608, 0.604, 0.826, and 0.963 in the analysis of successive groups (P < .001). The results indicate that the concordance between the experienced and inexperienced radiologists started as weak (κ <0.5) and gradually became very acceptable (κ >0.8). Therefore, a junior radiology resident can obtain enough experience in identifying a rather ambiguous anatomic structure in routine MRI after a brief instruction of a few minutes by a mentor and studying approximately 80 cases by oneself. CONCLUSIONS: Implementing this methodology will help radiology educators obtain more concrete ideas on the optimal time and effort required for supported self-directed visual learning processes in resident education.


Assuntos
Internato e Residência , Curva de Aprendizado , Ligamentos/anatomia & histologia , Vértebras Lombares/anatomia & histologia , Imageamento por Ressonância Magnética , Radiologia/educação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Instruções Programadas como Assunto , Adulto Jovem
19.
Clin Imaging ; 38(6): 792-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24928822

RESUMO

PURPOSE: This study aimed to determine the reliability of the iliolumbar ligament (ILL), 12th costa, aortic bifurcation (AB), right renal artery (RRA), and conus medullaris (CM) for numbering of vertebral segments. SUBJECTS AND METHODS: Five hundred five patients underwent routine lumbar MRI examinations including a cervicothoracic sagittal scout and T1 and T2-weighted sagittal and axial turbo spin echo images. Images were evaluated by two radiologists separately. RESULTS: The identifiability of ILL and 12th costa were 85.7% and 48.1%. AB, RRA, and CM were located more caudally in lumbarized S1 and more cranially in sacralized L5 cases. CONCLUSION: Landmarks suggested by previous studies are not reliable alternatives to cervicothoracic scout images due to wide ranges of distribution and inconsistencies in identification.


Assuntos
Vértebras Lombares/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/anatomia & histologia , Feminino , Humanos , Vértebras Lombares/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Artéria Renal/anatomia & histologia , Reprodutibilidade dos Testes , Medula Espinal/anatomia & histologia , Adulto Jovem
20.
World J Gastroenterol ; 20(38): 14004-9, 2014 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-25320540

RESUMO

AIM: To highlight magnetic resonance enterography (MRE) for diagnosis of patients with refractory iron deficiency anemia and normal endoscopy results. METHODS: Fifty-three patients diagnosed with iron deficiency anemia refractory to treatment and normal gastroscopy and colonoscopy results were admitted to this prospective study between June 2013 and December 2013. All patients underwent a standardized MRE examination with a 1.5 Tesla magnetic resonance imaging system using two six-channel phased-array abdominal coils. Adequate bowel distention and fast imaging sequences were utilized to achieve diagnostic accuracy. All segments of the small bowel, duodenum, jejunum, and ileum were examined in detail. All cases were examined independently by two radiologists with > 5 years of experience in abdominal magnetic resonance imaging. A consensus reading was performed for each patient following image examination. Both radiologists were blinded to patient history, laboratory findings, and endoscopy results. RESULTS: Twenty (37.7%) male and 33 (62.3%) female patients were included in the study. The mean age of the patients was 52.2 ± 13.6 years (range: 19-81 years, median 51.0). The age difference between the male and female patient groups was not statistically significant (54.8 ± 16.3 years vs 50.7 ± 11.7 years). MRE results were normal for 49 patients (92.5%). Four patients had abnormal MRE results. One patient with antral thickening was diagnosed with antral gastritis in the second-look gastroscopy. One patient had focal wall thickening in the 3(rd) and 4(th) portions of the duodenum. The affected areas were biopsied in a subsequent duodenoscopy, and adenocarcinoma was diagnosed. One patient had a fistula and focal contrast enhancement in the distal ileal segments, consistent with Crohn's disease. One patient had focal wall thickening with luminal narrowing in the mid-jejunum that was later biopsied during a double-balloon enteroscopy, and lymphoma was diagnosed. CONCLUSION: MRE is a non-invasive and effective alternative for evaluating possible malignancies of the small intestines and can serve as a guide for a second-look endoscopy.


Assuntos
Anemia Ferropriva/diagnóstico , Doença de Crohn/diagnóstico , Hemorragia Gastrointestinal/diagnóstico , Neoplasias Intestinais/diagnóstico , Intestinos/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Anemia Ferropriva/etiologia , Anemia Ferropriva/patologia , Anemia Ferropriva/terapia , Biópsia , Colonoscopia , Doença de Crohn/complicações , Doença de Crohn/patologia , Doença de Crohn/terapia , Feminino , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/patologia , Hemorragia Gastrointestinal/terapia , Gastroscopia , Humanos , Neoplasias Intestinais/complicações , Neoplasias Intestinais/patologia , Neoplasias Intestinais/terapia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA