Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Br J Anaesth ; 132(2): 343-351, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37925268

RESUMO

BACKGROUND: Tranexamic acid is an antifibrinolytic drug that is commonly administered for obstetric haemorrhage. Conventional viscoelastic tests are not sensitive to tranexamic acid, but the novel ClotPro® TPA-test can measure tranexamic acid-induced inhibition of fibrinolysis. We aimed to evaluate the TPA-test in pregnant and non-pregnant women. METHODS: We performed an in vitro study of whole blood samples spiked with tranexamic acid from pregnant women in the first, second, and third trimester (n=20 per group) and from non-pregnant women (n=20). We performed ClotPro TPA-tests of whole blood sample and ClotPro EX-tests, FIB-tests, and TPA-tests. RESULTS: Clot lysis was inhibited in a concentration-dependent manner up to a tranexamic acid concentration of 6.25 mg L-1. At tranexamic acid concentrations of 12.5 mg L-1 and above, clot lysis was completely inhibited. The concentration-effect relationship of tranexamic acid did not differ in a clinically important manner in blood from pregnant women across all three trimesters or from non-pregnant controls. A median maximum lysis cut-off value of at9 least 16% (25-75th percentiles 15-18), a median clot lysis time of 3600 s (25-75th percentiles 3600-3600), or both was associated with a tranexamic acid concentration of least 12.5 mg L-1. CONCLUSIONS: The ClotPro® TPA-test is sensitive in detecting inhibition of fibrinolysis by tranexamic acid in whole blood samples of pregnant and non-pregnant women. The concentration-effect relationship of tranexamic acid to inhibit fibrinolysis in whole blood did not differ for women in the first, second, and third trimester or for non-pregnant women.


Assuntos
Antifibrinolíticos , Ácido Tranexâmico , Feminino , Humanos , Gravidez , Fibrinólise , Ácido Tranexâmico/farmacologia , Ativador de Plasminogênio Tecidual/farmacologia , Tempo de Lise do Coágulo de Fibrina , Antifibrinolíticos/farmacologia
2.
Anesth Analg ; 135(5): 1031-1040, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35984000

RESUMO

BACKGROUND: Viscoelastically guided coagulation factor concentrate-based algorithms for the treatment of trauma-induced coagulopathy include the administration of prothrombin complex concentrates (PCCs). However, the exact role of PCC preparations in this context is a matter of debate. Particularly, the ideal diagnostic trigger for their administration and potential differences between heparin-containing and heparin-free preparations remain unclear. We investigated the hypothesis that 2 different PCCs might have distinct influences on in vitro blood coagulation. METHODS: We conducted a direct comparison of 2 commercially available PCC preparations (the heparin-containing Beriplex P/N and the heparin-free Cofact) in an in vitro hemodilution model. Sole fibrinogen substitution served as the control group. To characterize the hemostatic changes, we utilized conventional coagulation tests, a thrombin generation assay (TGA), and 2 different viscoelastic hemostatic assays (VHAs; ROTEM delta and ClotPro). RESULTS: Irrespective of the diagnostic assay used, no significant differences between the 2 PCC groups were observed. Fibrinogen levels remained stable from the baseline throughout every dilution level. The control group already showed an increased endogenous thrombin potential (ETP; nM·L -1 ·min -1 ) at all dilution levels compared to baseline (baseline, 2829.4 (432.8); 40% dilution, 4211.7 (391.6); 60% dilution, 4290.9 (300.8); 80% dilution, 3861.4 (303.5); all P < .001). Spiking with both PCC preparations led to a further-pronounced thrombin elevation in comparison to the control group (ETP at 40% dilution, PCC1: 4913.3 [370.2], PCC2: 4988.1 [265.7]; 60% dilution, PCC1: 5174.5 [234.7], PCC2: 5390.4 [334.9]; 80% dilution, PCC1: 5253.8 [357.9], PCC2: 5392.6 [313.4]; all P < .001). Conventional coagulation tests did not mirror the TGA results. Despite increased thrombin generation, prothrombin time was significantly prolonged at all dilution levels for the control group, and both PCC groups exhibited significant prolongations at the 60% and 80% dilution levels (all P < .001) compared to baseline. Similarly, VHA did not depict the thrombin elevation. Furthermore, descriptive analyses revealed relevant differences between the 2 VHA devices, particularly at baseline. CONCLUSIONS: Both PCC preparations (ie, irrespective of heparin content) induced significant elevation of thrombin generation, which was not depicted by conventional coagulation tests or VHA. Our in vitro results suggest that diagnostic assays routinely used to guide PCC administration might not adequately reflect thrombin generation in bleeding patients.


Assuntos
Hemostáticos , Humanos , Hemostáticos/farmacologia , Trombina , Hemodiluição , Fatores de Coagulação Sanguínea/farmacologia , Heparina/farmacologia , Fibrinogênio
3.
Obes Surg ; 33(6): 1687-1693, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37106268

RESUMO

PURPOSE: Opioid-free anesthesia (OFA) is an alternative to conventional opioid-based anesthesia (OBA) in patients undergoing bariatric surgery. Several small studies and a meta-analysis have suggested advantages of OFA for bariatric surgery, but current evidence is still contradictory, and a universally accepted concept has not yet been established. The purpose of this study was to determine whether patients undergoing bariatric surgery experience less postoperative pain and better postoperative recovery when anesthetized with an OFA regimen than with an OBA regimen. MATERIALS AND METHODS: This prospective observational cohort study, conducted between October 2020 and July 2021, compared patients receiving OFA with patients receiving OBA. Patients were visited 24 and 48 h after the surgical procedure and asked about their postoperative pain using the visual analogue scale (VAS). Additionally, the quality of recovery-40 questionnaire (QoR-40) and the postoperative opioid requirements were recorded. RESULTS: Ninety-nine patients were included and analyzed in this study (OFA: N = 50; OBA: N = 49). The OFA cohort exhibited less postoperative pain than the OBA cohort within 24 h (VAS median [interquartile range (IQR)]: 2.2 [1-4.4] vs. 4.1 [2-6.5]; P ≤ 0.001) and 48 h (VAS median [IQR]: 1.9 [0.4-4.1] vs. 3.1 [1.4-5.8]; P ≤ 0.001) postoperatively. Additionally, the OFA cohort had higher QoR-40 scores and required less opioid therapy postoperatively. CONCLUSION: Based on our results the use of OFA for bariatric surgery results in less pain, reduced opioid requirements, and improved postoperative recovery-adding additional evidence regarding the use of OFA in everyday clinical practice.


Assuntos
Anestesia , Cirurgia Bariátrica , Obesidade Mórbida , Humanos , Analgésicos Opioides , Obesidade Mórbida/cirurgia , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos
4.
Intensive Care Med Exp ; 11(1): 85, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38032394

RESUMO

Extracellular vesicles (EVs) represent nanometer-sized, subcellular spheres, that are released from almost any cell type and carry a wide variety of biologically relevant cargo. In severe cases of coronavirus disease 2019 (COVID-19) and other states of systemic pro-inflammatory activation, EVs, and their cargo can serve as conveyors and indicators for disease severity and progression. This information may help distinguish individuals with a less severe manifestation of the disease from patients who exhibit severe acute respiratory distress syndrome (ARDS) and require intensive care measures. Here, we investigated the potential of EVs and associated miRNAs to distinguish normal ward patients from intensive care unit (ICU) patients (N = 10/group), with 10 healthy donors serving as the control group. Blood samples from which plasma and subsequently EVs were harvested by differential ultracentrifugation (UC) were obtained at several points in time throughout treatment. EV-enriched fractions were characterized by flow cytometry (FC), nanoparticle tracking analysis (NTA), and qPCR to determine the presence of selected miRNAs. Circulating EVs showed specific protein signatures associated with endothelial and platelet origin over the course of the treatment. Additionally, significantly higher overall EV quantities corresponded with increased COVID-19 severity. MiR-223-3p, miR-191-5p, and miR-126-3p exhibited higher relative expression in the ICU group. Furthermore, EVs presenting endothelial-like protein signatures and the associated miR-126-3p showed the highest area under the curve in terms of receiver operating characteristics regarding the requirement for ICU treatment. In this exploratory investigation, we report that specific circulating EVs and miRNAs appear at higher levels in COVID-19 patients, especially when critical care measures are indicated. Our data suggest that endothelial-like EVs and associated miRNAs likely represent targets for future laboratory assays and may aid in clinical decision-making in COVID-19.

5.
Front Med (Lausanne) ; 8: 777145, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869496

RESUMO

Background: Viscoelastic coagulation testing has been suggested to help manage coagulopathy in critically ill patients with COVID-19. However, results from different viscoelastic devices are not readily comparable. ClotPro® is a novel thromboelastometry analyzer offering a wider range of commercially available assays. Methods: We compared the results from ClotPro with results from the well-established ROTEM® Delta device and conventional coagulation tests in critically ill patients with COVID-19. Results: Viscoelastic parameters indicated the presence of a potentially hypercoagulable state in the majority of patients. In up to 95 paired measurements, we found strong correlations between several parameters routinely used in clinical practice: (i) EX test vs. EXTEM CT, A5, A10, MCF, (ii) IN test vs. INTEM A5, A10, MCF, and (iii) FIB test vs. FIBTEM A5, A10, MCF (all R > 0.7 and p < 0.001). In contrast, IN test CT vs. INTEM CT showed only a moderate correlation (R = 0.53 and p < 0.001). Clot strength parameters of both devices exhibited strong correlations with platelet counts and fibrinogen levels (all R > 0.7 and p < 0.001). Divergent correlations of intrinsically activated assays with aPTT and anti-factor Xa activity were visible. Regarding absolute differences of test results, considerable delta occurred in CT, CFT, and clot strength parameters (all p < 0.001) between both devices. Conclusions: Several parameters obtained by ClotPro show strong correlations with ROTEM Delta. Due to weak correlations of intrinsically activated clotting times and considerable absolute differences in a number of parameters, our findings underline the need for device-specific algorithms in this patient cohort.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA