Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 99(6): 1945-1952, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35067004

RESUMO

BACKGROUND: There is limited experience of using the MANTA plug-based vascular closure device for percutaneous arterial closure of the femoral artery after venoarterial extracorporeal membrane oxygenation. OBJECTIVES: To study femoral artery complications and need for subsequent vascular interventions after percutaneous decannulation of venoarterial extracorporeal membrane oxygenation (VA ECMO) using the MANTA plug-based vascular closure device. METHODS: We studied 34 consecutive patients who underwent percutaneous decannulation of VA ECMO using the MANTA device. Primary outcomes were conversion to surgical cutdown of the groin at decannulation (immediate) or later. Secondary outcomes were type of vascular complication necessitating conversion to surgical cutdown of the groin. RESULTS: Six (17.7%) patients had to undergo immediate (n = 3) or late (n = 3) conversion to surgical cutdown of the groin. Of these, three were owing to occlusion of the common femoral artery resulting in insufficient distal perfusion and three owing to bleeding or pseudoaneurysm. The mechanism of failure was complete intravascular deployment of the MANTA device in three patients, incomplete MANTA sealing of the arteriotomy in one patient, MANTA-unrelated thrombotic occlusion in one patient, and unknown in one patient. Surgical cut-down was typically performed with concomitant catheter thrombectomy with or without patch reconstruction of the artery. CONCLUSION: Percutaneous decannulation of VA ECMO using the MANTA VCD was feasible but a substantial number of patients needed to be converted to unplanned surgical repair, owing to either closure site-located stenosis/occlusion or bleeding. If suboptimal MANTA positioning is suspected, a low threshold for conversion to surgical cutdown of the groin is recommended.


Assuntos
Cateterismo Periférico , Oxigenação por Membrana Extracorpórea , Dispositivos de Oclusão Vascular , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA