Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36236383

RESUMO

Low-cost sensors can provide inaccurate data as temperature and humidity affect sensor accuracy. Therefore, calibration and data correction are essential to obtain reliable measurements. This article presents a training and testing method used to calibrate a sensor module assembled from SO2 and NO2 electrochemical sensors (Alphasense B4 and B43F) alongside air temperature (T) and humidity (RH) sensors. Field training and testing were conducted in the industrialized coastal area of Quintero Bay, Chile. The raw responses of the electrochemical (mV) and T-RH sensors were subjected to multiple linear regression (MLR) using three data segments, based on either voltage (SO2 sensor) or temperature (NO2). The resulting MLR equations were used to estimate the reference concentration. In the field test, calibration improved the performance of the sensors after adding T and RH in a linear model. The most robust models for NO2 were associated with data collected at T < 10 °C (R2 = 0.85), while SO2 robust models (R2 = 0.97) were associated with data segments containing higher voltages. Overall, this training and testing method reduced the bias due to T and HR in the evaluated sensors and could be replicated in similar environments to correct raw data from low-cost electrochemical sensors. A calibration method based on training and sensor testing after relocation is presented. The results show that the SO2 sensor performed better when modeled for different segments of voltage data, and the NO2 sensor model performed better when calibrated for different temperature data segments.


Assuntos
Poluentes Atmosféricos , Dióxido de Nitrogênio , Poluentes Atmosféricos/análise , Calibragem , Monitoramento Ambiental , Umidade , Dióxido de Nitrogênio/análise
2.
Environ Monit Assess ; 192(3): 171, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32040639

RESUMO

Integration of low-cost air quality sensors with the internet of things (IoT) has become a feasible approach towards the development of smart cities. Several studies have assessed the performance of low-cost air quality sensors by comparing their measurements with reference instruments. We examined the performance of a low-cost IoT particulate matter (PM10 and PM2.5) sensor in the urban environment of Santiago, Chile. The prototype was assembled from a PM10-PM2.5 sensor (SDS011), a temperature and relative humidity sensor (BME280) and an IoT board (ESP8266/Node MCU). Field tests were conducted at three regulatory monitoring stations during the 2018 austral winter and spring seasons. The sensors at each site were operated in parallel with continuous reference air quality monitors (BAM 1020 and TEOM 1400) and a filter-based sampler (Partisol 2000i). Variability between sensor units (n = 7) and the correlation between the sensor and reference instruments were examined. Moderate inter-unit variability was observed between sensors for PM2.5 (normalized root-mean-square error 9-24%) and PM10 (10-37%). The correlations between the 1-h average concentrations reported by the sensors and continuous monitors were higher for PM2.5 (R2 0.47-0.86) than PM10 (0.24-0.56). The correlations (R2) between the 24-h PM2.5 averages from the sensors and reference instruments were 0.63-0.87 for continuous monitoring and 0.69-0.93 for filter-based samplers. Correlation analysis revealed that sensors tended to overestimate PM concentrations in high relative humidity (RH > 75%) and underestimate when RH was below 50%. Overall, the prototype evaluated exhibited adequate performance and may be potentially suitable for monitoring daily PM2.5 averages after correcting for RH.


Assuntos
Poluentes Atmosféricos , Monitoramento Ambiental , Material Particulado , Animais , Chile , Cidades , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Estações do Ano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA