Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Neural Eng ; 9(1): 016001, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22156042

RESUMO

Studying brain function and its local circuit dynamics requires neural interfaces that can record and stimulate the brain with high spatiotemporal resolution. Optogenetics, a technique that genetically targets specific neurons to express light-sensitive channel proteins, provides the capability to control central nervous system neuronal activity in mammals with millisecond time precision. This technique enables precise optical stimulation of neurons and simultaneous monitoring of neural response by electrophysiological means, both in the vicinity of and distant to the stimulation site. We previously demonstrated, in vitro, the dual capability (optical delivery and electrical recording) while testing a novel hybrid device (optrode-MEA), which incorporates a tapered coaxial optical electrode (optrode) and a 100 element microelectrode array (MEA). Here we report a fully chronic implant of a new version of this device in ChR2-expressing rats, and demonstrate its use in freely moving animals over periods up to 8 months. In its present configuration, we show the device delivering optical excitation to a single cortical site while mapping the neural response from the surrounding 30 channels of the 6 × 6 element MEA, thereby enabling recording of optically modulated single-unit and local field potential activity across several millimeters of the neocortical landscape.


Assuntos
Potenciais de Ação/fisiologia , Encéfalo/fisiologia , Eletrodos Implantados , Eletroencefalografia/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Neurônios/fisiologia , Imagens com Corantes Sensíveis à Voltagem/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Monitorização Ambulatorial/instrumentação , Ratos , Integração de Sistemas
2.
J Neurosci Methods ; 186(1): 8-17, 2010 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-19878693

RESUMO

The performance of neural electrodes in physiological fluid, especially in chronic use, is critical for the success of functional electrical stimulation devices. Tips of the Utah electrode arrays (UEAs) were coated with sputtered iridium oxide film (SIROF) and activated iridium oxide film (AIROF) to study the degradation during charge injection consistent with functional electrical stimulation (FES). The arrays were subjected to continuous biphasic, cathodal first, charge balanced (with equal cathodal and anodal pulse widths) current pulses for 7h (>1 million pulses) at a frequency of 50 Hz. The amplitude and width of the current pulses were varied to determine the damage threshold of the coatings. Degradation was characterized by scanning electron microscopy, inductively coupled plasma mass spectrometry, electrochemical impedance spectroscopy and cyclic voltammetry. The injected charge and charge density per phase were found to play synergistic role in damaging the electrodes. The damage threshold for SIROF coated electrode tips of the UEA was between 60 nC with a charge density of 1.9 mC/cm(2) per phase and 80 nC with a charge density of 1.0 mC/cm(2) per phase. While for AIROF coated electrode tips, the threshold was between 40 nC with a charge density of 0.9 mC/cm(2) per phase and 50 nC with a charge density of 0.5 mC/cm(2) per phase. Compared to AIROF, SIROF showed higher damage threshold and therefore is highly recommended to be used as a stimulation material.


Assuntos
Eletrônica/instrumentação , Eletrofisiologia/instrumentação , Irídio/química , Neurofisiologia/instrumentação , Animais , Artefatos , Líquidos Corporais/fisiologia , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Eletrodos/normas , Eletrodos Implantados/normas , Eletrônica/métodos , Eletrofisiologia/métodos , Humanos , Espectrometria de Massas , Microscopia Eletrônica de Varredura , Neurofisiologia/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Análise Espectral
3.
Artigo em Inglês | MEDLINE | ID: mdl-19965266

RESUMO

Sputtered iridium oxide (SIROF) is a candidate low-impedance coating for neural stimulation and recording electrodes. SIROF on planar substrates has exhibited a high charge-injection capacity and impedance suitable for indwelling cortical microelectrode applications. In the present work, the properties of SIROF electrode coatings deposited onto multi-shank penetrating arrays intended for intracortical and intraneural applications were examined. The charge-injection properties under constant current pulsing were evaluated for a range of pulsewidths and current densities using voltage transients to determine maximum potential excursions in an inorganic model of interstitial fluid at 37 degrees C. The charge-injection capacity of the SIROFs was significantly improved by the use of positive potential biasing in the interpulse period, but even without bias, the SIROFs reversibly inject higher charge than other iridium oxides or platinum. Typical deliverable charge levels of 25 to 160 nC/phase were obtained with 2000 mum(2) electrodes depending on pulsewidth and interpulse bias. Similar sized platinum electrodes could inject 3 to 8 nC/phase.


Assuntos
Microeletrodos , Animais , Engenharia Biomédica , Córtex Cerebral/fisiologia , Córtex Cerebral/cirurgia , Materiais Revestidos Biocompatíveis , Impedância Elétrica , Técnicas Eletroquímicas , Eletrodos Implantados , Desenho de Equipamento , Técnicas In Vitro , Irídio , Platina
4.
J Neural Eng ; 6(5): 055007, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19721185

RESUMO

Neural stimulation with high spatial and temporal precision is desirable both for studying the real-time dynamics of neural networks and for prospective clinical treatment of neurological diseases. Optical stimulation of genetically targeted neurons expressing the light sensitive channel protein Channelrhodopsin (ChR2) has recently been reported as a means for millisecond temporal control of neuronal spiking activities with cell-type selectivity. This offers the prospect of enabling local delivery of optical stimulation and the simultaneous monitoring of the neural activity by electrophysiological means, both in the vicinity of and distant to the stimulation site. We report here a novel dual-modality hybrid device, which consists of a tapered coaxial optical waveguide ('optrode') integrated into a 100 element intra-cortical multi-electrode recording array. We first demonstrate the dual optical delivery and electrical recording capability of the single optrode in in vitro preparations of mouse retina, photo-stimulating the native retinal photoreceptors while recording light-responsive activities from ganglion cells. The dual-modality array device was then used in ChR2 transfected mouse brain slices. Specifically, epileptiform events were reliably optically triggered by the optrode and their spatiotemporal patterns were simultaneously recorded by the multi-electrode array.


Assuntos
Potenciais de Ação/fisiologia , Encéfalo/fisiologia , Estimulação Elétrica/instrumentação , Eletrodos Implantados , Dispositivos Ópticos , Retina/fisiologia , Potenciais de Ação/efeitos da radiação , Animais , Encéfalo/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Camundongos , Camundongos Endogâmicos C57BL , Retina/efeitos da radiação , Integração de Sistemas
5.
Artigo em Inglês | MEDLINE | ID: mdl-19964571

RESUMO

Targeted neural excitation coupled with simultaneous multineuron recording is desirable both for studying the real-time dynamics of neural circuits and for prospective clinical treatment of neurological diseases. Optical stimulation of genetically targeted neurons expressing the light sensitive channel protein Channelrhodopsin (ChR2) has recently been reported as a means for millisecond temporal control of neuronal spiking activity with cell-type selectivity. This offers the prospect of enabling local (cellular level) stimulation and the concomitant monitoring of neural activity by extracellular electrophysiological methods, both in the vicinity of and distant to the stimulation site. We report here a novel dual-modality hybrid device which consists of a tapered coaxial optical waveguide ("optrode") directly integrated into a 100 element intra-cortical multi-electrode recording array. The dual-modality array device was used in ChR2 transfected mouse brain slices. Specifically, epileptiform events were reliably optically triggered by the optrode and their spatiotemporal patterns were simultaneously recorded by the multi-electrode array.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Microeletrodos , Neurônios/fisiologia , Animais , Encéfalo/fisiologia , Encéfalo/fisiopatologia , Estimulação Elétrica , Terapia por Estimulação Elétrica/instrumentação , Epilepsia/fisiopatologia , Desenho de Equipamento , Luz , Camundongos , Dispositivos Ópticos , Rodopsina/fisiologia , Córtex Somatossensorial/fisiologia , Córtex Somatossensorial/fisiopatologia , Sinapses/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA