Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 42(6): 583-594, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30657188

RESUMO

BACKGROUND: There are anecdotal reports of sudden death despite a functional implantable cardioverter defibrillator (ICD). We sought to describe scenarios leading to fatal or near-fatal outcome due to inappropriately inhibited ICD therapy in devices programmed with single-chamber detection criteria. METHODS: Programmed settings, episode lists, and intracardiac electrograms from 24 patients with a life-threatening event (n = 12) or fatal outcome (n = 12) related to failed ventricular arrhythmia detection were used to clarify the underlying scenario. RESULTS: Fifty episodes of failed ventricular arrhythmia detection were identified and categorized into six scenarios: (1) spontaneous ventricular tachycardia (VT) or ventricular fibrillation (VF) with a rate below the detection limits, (2) misclassification of polymorphic VT (PVT) or VF as supraventricular tachycardia (SVT), (3) misclassification of VT/VF as cluster of nonsustained VT episodes, (4) misclassification of monomorphic VT (MVT) as SVT, (5) inappropriate shock abortion, and (6) false termination detection. These scenarios occurred respectively 6, 9, 3, 9, 8, and 15 times. In 9/9 (100%) patients with PVT/VF classified as SVT, rate stability was active for rates ranging from 222 to 250 beats/min. MVT detected as SVT was due to the sudden onset criterion in 7/9 (78%) patients and twice a consequence of the rate stability criterion active for rates ranging from 200 to 250 beats/min. CONCLUSION: We describe six scenarios leading to failure of ventricular arrhythmia detection in a single-chamber detection setting withholding life-saving therapy. These scenarios are more likely to occur with high-rate programming and long detection times, especially if combined with rate stability and sudden onset.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/mortalidade , Fibrilação Ventricular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA