Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 35(3): 452-461.e3, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37852601

RESUMO

PURPOSE: To develop and evaluate a smartphone augmented reality (AR) system for a large 50-mm liver tumor ablation with treatment planning for composite overlapping ablation zones. MATERIALS AND METHODS: A smartphone AR application was developed to display tumor, probe, projected probe paths, ablated zones, and real-time percentage of the ablated target tumor volume. Fiducial markers were attached to phantoms and an ablation probe hub for tracking. The system was evaluated with tissue-mimicking thermochromic phantoms and gel phantoms. Four interventional radiologists performed 2 trials each of 3 probe insertions per trial using AR guidance versus computed tomography (CT) guidance approaches in 2 gel phantoms. Insertion points and optimal probe paths were predetermined. On Gel Phantom 2, serial ablated zones were saved and continuously displayed after each probe placement/adjustment, enabling feedback and iterative planning. The percentages of tumor ablated for AR guidance versus CT guidance, and with versus without display of recorded ablated zones, were compared among interventional radiologists with pairwise t-tests. RESULTS: The means of percentages of tumor ablated for CT freehand and AR guidance were 36% ± 7 and 47% ± 4 (P = .004), respectively. The mean composite percentages of tumor ablated for AR guidance were 43% ± 1 (without) and 50% ± 2 (with display of ablation zone) (P = .033). There was no strong correlation between AR-guided percentage of ablation and years of experience (r < 0.5), whereas there was a strong correlation between CT-guided percentage of ablation and years of experience (r > 0.9). CONCLUSIONS: A smartphone AR guidance system for dynamic iterative large liver tumor ablation was accurate, performed better than conventional CT guidance, especially for less experienced interventional radiologists, and enhanced more standardized performance across experience levels for ablation of a 50-mm tumor.


Assuntos
Realidade Aumentada , Neoplasias Hepáticas , Cirurgia Assistida por Computador , Humanos , Smartphone , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia
2.
Eur Radiol ; 31(5): 3165-3176, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33146796

RESUMO

OBJECTIVES: The early infection dynamics of patients with SARS-CoV-2 are not well understood. We aimed to investigate and characterize associations between clinical, laboratory, and imaging features of asymptomatic and pre-symptomatic patients with SARS-CoV-2. METHODS: Seventy-four patients with RT-PCR-proven SARS-CoV-2 infection were asymptomatic at presentation. All were retrospectively identified from 825 patients with chest CT scans and positive RT-PCR following exposure or travel risks in outbreak settings in Japan and China. CTs were obtained for every patient within a day of admission and were reviewed for infiltrate subtypes and percent with assistance from a deep learning tool. Correlations of clinical, laboratory, and imaging features were analyzed and comparisons were performed using univariate and multivariate logistic regression. RESULTS: Forty-eight of 74 (65%) initially asymptomatic patients had CT infiltrates that pre-dated symptom onset by 3.8 days. The most common CT infiltrates were ground glass opacities (45/48; 94%) and consolidation (22/48; 46%). Patient body temperature (p < 0.01), CRP (p < 0.01), and KL-6 (p = 0.02) were associated with the presence of CT infiltrates. Infiltrate volume (p = 0.01), percent lung involvement (p = 0.01), and consolidation (p = 0.043) were associated with subsequent development of symptoms. CONCLUSIONS: COVID-19 CT infiltrates pre-dated symptoms in two-thirds of patients. Body temperature elevation and laboratory evaluations may identify asymptomatic patients with SARS-CoV-2 CT infiltrates at presentation, and the characteristics of CT infiltrates could help identify asymptomatic SARS-CoV-2 patients who subsequently develop symptoms. The role of chest CT in COVID-19 may be illuminated by a better understanding of CT infiltrates in patients with early disease or SARS-CoV-2 exposure. KEY POINTS: • Forty-eight of 74 (65%) pre-selected asymptomatic patients with SARS-CoV-2 had abnormal chest CT findings. • CT infiltrates pre-dated symptom onset by 3.8 days (range 1-5). • KL-6, CRP, and elevated body temperature identified patients with CT infiltrates. Higher infiltrate volume, percent lung involvement, and pulmonary consolidation identified patients who developed symptoms.


Assuntos
COVID-19 , SARS-CoV-2 , China/epidemiologia , Surtos de Doenças , Humanos , Japão , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
J Vasc Interv Radiol ; 31(12): 2122-2131, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33012647

RESUMO

PURPOSE: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets. METHODS: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols. First-pass navigation success was defined as catheter delivery into a targeted airway segment solely using AF, with second-pass success defined as reaching the targeted segment by using updated AF image guidance based on confirmatory cone-beam CT. Secondary outcomes were navigation error, navigation time, radiation exposure, and preliminary safety. RESULTS: First-pass success was 100% (10/10) ex vivo and 19/24 (79%) and 11/15 (73%) for in vivo phases 1 and 2, respectively. Phase 2 second-pass success was 4/4 (100%). Navigation errors were 2.2 ± 1.2 mm ex vivo and 4.9 ± 3.2 mm and 4.0 ± 2.6 mm for in vivo phases 1 and 2, respectively. No major device-related complications were observed in the in vivo experiments. CONCLUSIONS: Endobronchial navigation is feasible and accurate with cone-beam CT-based AF image guidance. AF can guide endobronchial navigation with endovascular catheters and steerable guiding sheaths to peripheral lung targets, potentially overcoming limitations associated with bronchoscopy.


Assuntos
Cateterismo/instrumentação , Catéteres , Tomografia Computadorizada de Feixe Cônico/instrumentação , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Radiografia Intervencionista/instrumentação , Animais , Estudos de Viabilidade , Fluoroscopia/instrumentação , Masculino , Modelos Animais , Interpretação de Imagem Radiográfica Assistida por Computador , Sus scrofa
4.
J Biomech Eng ; 142(12)2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34043756

RESUMO

Swine are a commonly used model in translational pulmonary research. However, in vivo airway morphometry during respiration has not been studied in extensive detail using modern imaging tools. Chest computed tomographic was performed in swine (n = 3) at multiple stages of respiration. Morphometric parameters of each airway segment at end-expiration and end-inspiration were compared as well as among matched anatomical regions (proximal and distal; ventral, lateral, and dorsal). Analysis included segment diameter, length, ellipticity, and the bifurcation angle between daughter branches. Deformation of the airway during respiration was qualitatively visualized using a point-to-point deformation map. Comparison of airway generation showed airway diameter and length were larger at end-inspiration in the fourth and seventh generations compared to end-expiration. Bifurcation angle was larger at end-inspiration compared to end-expiration. Analysis by anatomical region showed that length and bifurcation angle were larger at inspiration in the distal airway regions only. Regardless of respiratory phase, the lateral regions had larger diameters and lengths compared to the ventral and dorsal regions at similar generations and proximal regions had larger bifurcation angles. The findings that morphological changes were more prevalent in distal airways during respiration was confirmed by analysis of a deformation map. Compared to human airway models, the relative diameter may be smaller and length may be greater in swine in similar airway generations. This morphometric description of the swine airways during respiration may guide conduct of preclinical translational studies, revealing advantages and limitations of swine models for specific evaluations. Such morphometric parameters may directly determine the suitability of the swine model for the study of lung interventions, in terms of recapitulation of human morphometry dynamics.


Assuntos
Respiração , Animais , Expiração , Pulmão , Suínos , Tomografia Computadorizada por Raios X
5.
Stroke ; 49(4): 856-864, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29535267

RESUMO

BACKGROUND AND PURPOSE: Many ruptured intracranial aneurysms (IAs) are small. Clinical presentations suggest that small and large IAs could have different phenotypes. It is unknown if small and large IAs have different characteristics that discriminate rupture. METHODS: We analyzed morphological, hemodynamic, and clinical parameters of 413 retrospectively collected IAs (training cohort; 102 ruptured IAs). Hierarchal cluster analysis was performed to determine a size cutoff to dichotomize the IA population into small and large IAs. We applied multivariate logistic regression to build rupture discrimination models for small IAs, large IAs, and an aggregation of all IAs. We validated the ability of these 3 models to predict rupture status in a second, independently collected cohort of 129 IAs (testing cohort; 14 ruptured IAs). RESULTS: Hierarchal cluster analysis in the training cohort confirmed that small and large IAs are best separated at 5 mm based on morphological and hemodynamic features (area under the curve=0.81). For small IAs (<5 mm), the resulting rupture discrimination model included undulation index, oscillatory shear index, previous subarachnoid hemorrhage, and absence of multiple IAs (area under the curve=0.84; 95% confidence interval, 0.78-0.88), whereas for large IAs (≥5 mm), the model included undulation index, low wall shear stress, previous subarachnoid hemorrhage, and IA location (area under the curve=0.87; 95% confidence interval, 0.82-0.93). The model for the aggregated training cohort retained all the parameters in the size-dichotomized models. Results in the testing cohort showed that the size-dichotomized rupture discrimination model had higher sensitivity (64% versus 29%) and accuracy (77% versus 74%), marginally higher area under the curve (0.75; 95% confidence interval, 0.61-0.88 versus 0.67; 95% confidence interval, 0.52-0.82), and similar specificity (78% versus 80%) compared with the aggregate-based model. CONCLUSIONS: Small (<5 mm) and large (≥5 mm) IAs have different hemodynamic and clinical, but not morphological, rupture discriminants. Size-dichotomized rupture discrimination models performed better than the aggregate model.


Assuntos
Aneurisma Roto/epidemiologia , Hemodinâmica , Aneurisma Intracraniano/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Angiografia Digital , Angiografia Cerebral , Análise por Conglomerados , Estudos de Coortes , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Análise Multivariada , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ruptura Espontânea
6.
J Biomech Eng ; 139(12)2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28857116

RESUMO

Computational fluid dynamics (CFD) is a promising tool to aid in clinical diagnoses of cardiovascular diseases. However, it uses assumptions that simplify the complexities of the real cardiovascular flow. Due to high-stakes in the clinical setting, it is critical to calculate the effect of these assumptions in the CFD simulation results. However, existing CFD validation approaches do not quantify error in the simulation results due to the CFD solver's modeling assumptions. Instead, they directly compare CFD simulation results against validation data. Thus, to quantify the accuracy of a CFD solver, we developed a validation methodology that calculates the CFD model error (arising from modeling assumptions). Our methodology identifies independent error sources in CFD and validation experiments, and calculates the model error by parsing out other sources of error inherent in simulation and experiments. To demonstrate the method, we simulated the flow field of a patient-specific intracranial aneurysm (IA) in the commercial CFD software star-ccm+. Particle image velocimetry (PIV) provided validation datasets for the flow field on two orthogonal planes. The average model error in the star-ccm+ solver was 5.63 ± 5.49% along the intersecting validation line of the orthogonal planes. Furthermore, we demonstrated that our validation method is superior to existing validation approaches by applying three representative existing validation techniques to our CFD and experimental dataset, and comparing the validation results. Our validation methodology offers a streamlined workflow to extract the "true" accuracy of a CFD solver.


Assuntos
Hidrodinâmica , Aneurisma Intracraniano/fisiopatologia , Modelagem Computacional Específica para o Paciente , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Imagens de Fantasmas
8.
J Biomech Eng ; 138(6): 061009, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27109451

RESUMO

Recent high-resolution computational fluid dynamics (CFD) studies have detected persistent flow instability in intracranial aneurysms (IAs) that was not observed in previous in silico studies. These flow fluctuations have shown incidental association with rupture in a small aneurysm dataset. The aims of this study are to explore the capabilities and limitations of a commercial cfd solver in capturing such velocity fluctuations, whether fluctuation kinetic energy (fKE) as a marker to quantify such instability could be a potential parameter to predict aneurysm rupture, and what geometric parameters might be associated with such fluctuations. First, we confirmed that the second-order discretization schemes and high spatial and temporal resolutions are required to capture these aneurysmal flow fluctuations. Next, we analyzed 56 patient-specific middle cerebral artery (MCA) aneurysms (12 ruptured) by transient, high-resolution CFD simulations with a cycle-averaged, constant inflow boundary condition. Finally, to explore the mechanism by which such flow instabilities might arise, we investigated correlations between fKE and several aneurysm geometrical parameters. Our results show that flow instabilities were present in 8 of 56 MCA aneurysms, all of which were unruptured bifurcation aneurysms. Statistical analysis revealed that fKE could not differentiate ruptured from unruptured aneurysms. Thus, our study does not lend support to these flow instabilities (based on a cycle-averaged constant inflow as opposed to peak velocity) being a marker for rupture. We found a positive correlation between fKE and aneurysm size as well as size ratio. This suggests that the intrinsic flow instability may be associated with the breakdown of an inflow jet penetrating the aneurysm space.


Assuntos
Simulação por Computador , Hidrodinâmica , Aneurisma Intracraniano/fisiopatologia , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelagem Computacional Específica para o Paciente
9.
J Vasc Surg ; 59(5): 1410-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23845661

RESUMO

BACKGROUND: Experimental modeling of arteriovenous hemodialysis fistula (AVF) hemodynamics is challenging. Mathematical modeling struggles to accurately represent the capillary bed and venous circulation. In vivo animal models are expensive and labor intensive. We hypothesized that an in vitro, physiologic model of the extremity arteriovenous circulation with provisions for AVF and distal revascularization and interval ligation (DRIL) configurations could be created as a platform for hemodynamic modeling and testing. METHODS: An anatomic, upper extremity arteriovenous model was constructed of tubing focusing on the circulation from the subclavian artery to subclavian vein. Tubing material, length, diameter, and wall thickness were selected to match vessel compliance and morphology. All branch points were constructed at physiologic angles. The venous system and capillary bed were modeled using tubing and one-way valves and compliance chambers. A glycerin/water solution was created to match blood viscosity. The system was connected to a heart simulator. Pressure waveforms and flows were recorded at multiple sites along the model for the native circulation, brachiocephalic AVF configuration, and the AVF with DR without and with IL (DR no IL and DRIL). RESULTS: A preset mean cardiac output of 4.2 L/min from the heart simulator yielded a subclavian artery pressure of 125/55 mm Hg and a brachial artery pressure of 121/54 mm Hg with physiologic arterial waveforms. Mean capillary bed perfusion pressure was 41 mm Hg, and mean venous pressure in the distal brachial vein was 17 mm Hg with physiologic waveforms. AVF configuration resulted in a 15% decrease in distal pressure and a 65% decrease in distal flow to the hand. DR no IL had no change in distal pressure with a 27% increase in distal flow. DRIL resulted in a 3% increase in distal pressure and a 15% increase in distal flow to the hand above that of DR no IL. Flow through the DR bypass decreased from 329 mL/min to 55 mL/min with the addition of IL. Flow through the AVF for both DR no IL and DRIL was preserved. CONCLUSIONS: Through the construction and validation of an in vitro, pulsatile arteriovenous model, the intricate hemodynamics of AVF and treatments for ischemic steal can be studied. DR with or without IL improved distal blood flow in addition to preserving AVF flow. IL decreased the blood flow through the DR bypass itself. The findings of the AVF as a pressure sink and the relative role of IL with DR bypass has allowed this model to provide hemodynamic insight difficult or impossible to obtain in animal or human models. Further study of these phenomena with this model should allow for more effective AVF placement and maturation while personalizing treatment for associated ischemic steal. CLINICAL RELEVANCE: The complications of arteriovenous fistula (AVF)-associated steal with its concurrent surgical treatments have been clinically described but have relatively little published, concrete hemodynamic data. A further understanding of the underlying hemodynamics is necessary to prevent the occurrence of steal and improve treatment when it occurs. Specific objectives are to study the blood flow through an AVF with varying anatomic and physiologic parameters, determine what factors contribute to the development of arterial steal distal to an AVF, and create optimal interventions to treat arterial steal from an AVF when it occurs. The long-term goal is creation of AVF tailored to patient-specific parameters, resulting in higher rates of functional fistulas with decreases in fistula-related complications. The ability to study fluid dynamics using a unique, in vitro, upper extremity pulsatile arteriovenous circulation simulator creates the ideal platform for this work.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Hemodinâmica , Isquemia/fisiopatologia , Modelos Anatômicos , Modelos Cardiovasculares , Artéria Subclávia/cirurgia , Veia Subclávia/cirurgia , Extremidade Superior/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Viscosidade Sanguínea , Capilares/fisiopatologia , Frequência Cardíaca , Humanos , Isquemia/etiologia , Isquemia/terapia , Ligadura , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Artéria Subclávia/fisiopatologia , Veia Subclávia/fisiopatologia
10.
Artigo em Inglês | MEDLINE | ID: mdl-38814530

RESUMO

PURPOSE: Targeting accuracy determines outcomes for percutaneous needle interventions. Augmented reality (AR) in IR may improve procedural guidance and facilitate access to complex locations. This study aimed to evaluate percutaneous needle placement accuracy using a goggle-based AR system compared to an ultrasound (US)-based fusion navigation system. METHODS: Six interventional radiologists performed 24 independent needle placements in an anthropomorphic phantom (CIRS 057A) in four needle guidance cohorts (n = 6 each): (1) US-based fusion, (2) goggle-based AR with stereoscopically projected anatomy (AR-overlay), (3) goggle AR without the projection (AR-plain), and (4) CT-guided freehand. US-based fusion included US/CT registration with electromagnetic (EM) needle, transducer, and patient tracking. For AR-overlay, US, EM-tracked needle, stereoscopic anatomical structures and targets were superimposed over the phantom. Needle placement accuracy (distance from needle tip to target center), placement time (from skin puncture to final position), and procedure time (time to completion) were measured. RESULTS: Mean needle placement accuracy using US-based fusion, AR-overlay, AR-plain, and freehand was 4.5 ± 1.7 mm, 7.0 ± 4.7 mm, 4.7 ± 1.7 mm, and 9.2 ± 5.8 mm, respectively. AR-plain demonstrated comparable accuracy to US-based fusion (p = 0.7) and AR-overlay (p = 0.06). Excluding two outliers, AR-overlay accuracy became 5.9 ± 2.6 mm. US-based fusion had the highest mean placement time (44.3 ± 27.7 s) compared to all navigation cohorts (p < 0.001). Longest procedure times were recorded with AR-overlay (34 ± 10.2 min) compared to AR-plain (22.7 ± 8.6 min, p = 0.09), US-based fusion (19.5 ± 5.6 min, p = 0.02), and freehand (14.8 ± 1.6 min, p = 0.002). CONCLUSION: Goggle-based AR showed no difference in needle placement accuracy compared to the commercially available US-based fusion navigation platform. Differences in accuracy and procedure times were apparent with different display modes (with/without stereoscopic projections). The AR-based projection of the US and needle trajectory over the body may be a helpful tool to enhance visuospatial orientation. Thus, this study refines the potential role of AR for needle placements, which may serve as a catalyst for informed implementation of AR techniques in IR.

11.
Sci Rep ; 14(1): 13352, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858467

RESUMO

Liver cancer ranks as the fifth leading cause of cancer-related death globally. Direct intratumoral injections of anti-cancer therapeutics may improve therapeutic efficacy and mitigate adverse effects compared to intravenous injections. Some challenges of intratumoral injections are that the liquid drug formulation may not remain localized and have unpredictable volumetric distribution. Thus, drug delivery varies widely, highly-dependent upon technique. An X-ray imageable poloxamer 407 (POL)-based drug delivery gel was developed and characterized, enabling real-time feedback. Utilizing three needle devices, POL or a control iodinated contrast solution were injected into an ex vivo bovine liver. The 3D distribution was assessed with cone beam computed tomography (CBCT). The 3D distribution of POL gels demonstrated localized spherical morphologies regardless of the injection rate. In addition, the gel 3D conformal distribution could be intentionally altered, depending on the injection technique. When doxorubicin (DOX) was loaded into the POL and injected, DOX distribution on optical imaging matched iodine distribution on CBCT suggesting spatial alignment of DOX and iodine localization in tissue. The controllability and localized deposition of this formulation may ultimately reduce the dependence on operator technique, reduce systemic side effects, and facilitate reproducibility across treatments, through more predictable standardized delivery.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Doxorrubicina , Sistemas de Liberação de Medicamentos , Hidrogéis , Agulhas , Poloxâmero , Hidrogéis/química , Animais , Doxorrubicina/administração & dosagem , Doxorrubicina/química , Doxorrubicina/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Poloxâmero/química , Bovinos , Tomografia Computadorizada de Feixe Cônico/métodos , Fígado/diagnóstico por imagem , Fígado/metabolismo
12.
Res Sq ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38496436

RESUMO

Liver cancer ranks as the fifth leading cause of cancer-related death globally. Direct intratumoral injections of anti-cancer therapeutics may improve therapeutic efficacy and mitigate adverse effects compared to intravenous injections. Some challenges of intratumoral injections are that the liquid drug formulation may not remain localized and have unpredictable volumetric distribution. Thus, drug delivery varies widely, highly-dependent upon technique. An x-ray imageable poloxamer 407 (POL)-based drug delivery gel was developed and characterized, enabling real-time feedback. Utilizing three needle devices, POL or a control iodinated contrast solution were injected into an ex vivo bovine liver. The 3D distribution was assessed with cone beam computed tomography (CBCT). The 3D distribution of POL gels demonstrated localized spherical morphologies regardless of the injection rate. In addition, the gel 3D conformal distribution could be intentionally altered, depending on the injection technique. When doxorubicin (DOX) was loaded into the POL and injected, DOX distribution on optical imaging matched iodine distribution on CBCT suggesting spatial alignment of DOX and iodine localization in tissue. The controllability and localized deposition of this formulation may ultimately reduce the dependence on operator technique, reduce systemic side effects, and facilitate reproducibility across treatments, through more predictable standardized delivery.

13.
J Med Imaging (Bellingham) ; 10(2): 025001, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36875636

RESUMO

Purpose: An augmented reality (AR) system was developed to facilitate free-hand real-time needle guidance for transperineal prostate (TP) procedures and to overcome the limitations of a traditional guidance grid. Approach: The HoloLens AR system enables the superimposition of annotated anatomy derived from preprocedural volumetric images onto a patient and addresses the most challenging part of free-hand TP procedures by providing real-time needle tip localization and needle depth visualization during insertion. The AR system accuracy, or the image overlay accuracy ( n = 56 ), and needle targeting accuracy ( n = 24 ) were evaluated within a 3D-printed phantom. Three operators each used a planned-path guidance method ( n = 4 ) and free-hand guidance ( n = 4 ) to guide needles into targets in a gel phantom. Placement error was recorded. The feasibility of the system was further evaluated by delivering soft tissue markers into tumors of an anthropomorphic pelvic phantom via the perineum. Results: The image overlay error was 1.29 ± 0.57 mm , and needle targeting error was 2.13 ± 0.52 mm . The planned-path guidance placements showed similar error compared to the free-hand guidance ( 4.14 ± 1.08 mm versus 4.20 ± 1.08 mm , p = 0.90 ). The markers were successfully implanted either into or in close proximity to the target lesion. Conclusions: The HoloLens AR system can provide accurate needle guidance for TP interventions. AR support for free-hand lesion targeting is feasible and may provide more flexibility than grid-based methods, due to the real-time 3D and immersive experience during free-hand TP procedures.

14.
PLoS One ; 18(8): e0289674, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37540658

RESUMO

PURPOSE: Heat-induced destruction of cancer cells via microwave ablation (MWA) is emerging as a viable treatment of primary and metastatic liver cancer. Prediction of the impacted zone where cell death occurs, especially in the presence of vasculature, is challenging but may be achieved via biophysical modeling. To advance and characterize thermal MWA for focal cancer treatment, an in vivo method and experimental dataset were created for assessment of biophysical models designed to dynamically predict ablation zone parameters, given the delivery device, power, location, and proximity to vessels. MATERIALS AND METHODS: MWA zone size, shape, and temperature were characterized and monitored in the absence of perfusion in ex vivo liver and a tissue-mimicking thermochromic phantom (TMTCP) at two power settings. Temperature was monitored over time using implanted thermocouples with their locations defined by CT. TMTCPs were used to identify the location of the ablation zone relative to the probe. In 6 swine, contrast-enhanced CTs were additionally acquired to visualize vasculature and absence of perfusion along with corresponding post-mortem gross pathology. RESULTS: Bench studies demonstrated average ablation zone sizes of 4.13±1.56cm2 and 8.51±3.92cm2, solidity of 0.96±0.06 and 0.99±0.01, ablations centered 3.75cm and 3.5cm proximal to the probe tip, and temperatures of 50 ºC at 14.5±13.4s and 2.5±2.1s for 40W and 90W ablations, respectively. In vivo imaging showed average volumes of 9.8±4.8cm3 and 33.2±28.4cm3 and 3D solidity of 0.87±0.02 and 0.75±0.15, and gross pathology showed a hemorrhagic halo area of 3.1±1.2cm2 and 9.1±3.0cm2 for 40W and 90W ablations, respectfully. Temperatures reached 50ºC at 19.5±9.2s and 13.0±8.3s for 40W and 90W ablations, respectively. CONCLUSION: MWA results are challenging to predict and are more variable than manufacturer-provided and bench predictions due to vascular stasis, heat-induced tissue changes, and probe operating conditions. Accurate prediction of MWA zones and temperature in vivo requires comprehensive thermal validation sets.


Assuntos
Fígado , Animais , Suínos , Fígado/patologia , Fígado/cirurgia , Micro-Ondas , Temperatura , Técnicas de Ablação , Ablação por Radiofrequência
15.
Urology ; 181: 76-83, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37572884

RESUMO

OBJECTIVE: To report an initial experience with a novel, "fully" transperineal (TP) prostate fusion biopsy using an unconstrained ultrasound transducer placed on the perineal skin to guide biopsy needles inserted via a TP approach. METHODS: Conventional TP prostate biopsies for detection of prostate cancer have been performed with transrectal ultrasound, requiring specialized hardware, imposing limitations on needle trajectory, and contributing to patient discomfort. Seventy-six patients with known or suspected prostate cancer underwent 78 TP biopsy sessions in an academic center between June 2018 and April 2022 and were included in this study. These patients underwent TP prostate fusion biopsy using a grid or freehand device with transrectal ultrasound as well as TP prostate fusion biopsy using TP ultrasound in the same session. Per-session and per-lesion cancer detection rates were compared for conventional and fully TP biopsies using Fisher exact and McNemar's tests. RESULTS: After a refinement period in 30 patients, 92 MRI-visible prostate lesions were sampled in 46 subsequent patients, along with repeat biopsies in 2 of the 30 patients from the refinement period. Grade group ≥2 cancer was diagnosed in 24/92 lesions (26%) on conventional TP biopsy (17 lesions with grid, 7 with freehand device), and in 25/92 lesions (27%) on fully TP biopsy (P = 1.00), with a 73/92 (79%) rate of agreement for grade group ≥2 cancer between the two methods. CONCLUSION: Fully TP biopsy is feasible and may detect prostate cancer with detection rates comparable to conventional TP biopsy.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Ultrassonografia de Intervenção/métodos , Biópsia , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética
16.
Semin Intervent Radiol ; 38(5): 565-575, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34853503

RESUMO

Image-guided robotics for biopsy and ablation aims to minimize procedure times, reduce needle manipulations, radiation, and complications, and enable treatment of larger and more complex tumors, while facilitating standardization for more uniform and improved outcomes. Robotic navigation of needles enables standardized and uniform procedures which enhance reproducibility via real-time precision feedback, while avoiding radiation exposure to the operator. Robots can be integrated with computed tomography (CT), cone beam CT, magnetic resonance imaging, and ultrasound and through various techniques, including stereotaxy, table-mounted, floor-mounted, and patient-mounted robots. The history, challenges, solutions, and questions facing the field of interventional radiology (IR) and interventional oncology are reviewed, to enable responsible clinical adoption and value definition via ergonomics, workflows, business models, and outcome data. IR-integrated robotics is ready for broader adoption. The robots are coming!

17.
Cardiovasc Intervent Radiol ; 44(5): 774-781, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33409547

RESUMO

PURPOSE: To compare needle placement performance using an augmented reality (AR) navigation platform implemented on smartphone or smartglasses devices to that of CBCT-guided fluoroscopy in a phantom. MATERIALS AND METHODS: An AR application was developed to display a planned percutaneous needle trajectory on the smartphone (iPhone7) and smartglasses (HoloLens1) devices in real time. Two AR-guided needle placement systems and CBCT-guided fluoroscopy with navigation software (XperGuide, Philips) were compared using an anthropomorphic phantom (CIRS, Norfolk, VA). Six interventional radiologists each performed 18 independent needle placements using smartphone (n = 6), smartglasses (n = 6), and XperGuide (n = 6) guidance. Placement error was defined as the distance from the needle tip to the target center. Placement time was recorded. For XperGuide, dose-area product (DAP, mGy*cm2) and fluoroscopy time (sec) were recorded. Statistical comparisons were made using a two-way repeated measures ANOVA. RESULTS: The placement error using the smartphone, smartglasses, or XperGuide was similar (3.98 ± 1.68 mm, 5.18 ± 3.84 mm, 4.13 ± 2.38 mm, respectively, p = 0.11). Compared to CBCT-guided fluoroscopy, the smartphone and smartglasses reduced placement time by 38% (p = 0.02) and 55% (p = 0.001), respectively. The DAP for insertion using XperGuide was 3086 ± 2920 mGy*cm2, and no intra-procedural radiation was required for augmented reality. CONCLUSIONS: Smartphone- and smartglasses-based augmented reality reduced needle placement time and radiation exposure while maintaining placement accuracy compared to a clinically validated needle navigation platform.


Assuntos
Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Óculos Inteligentes , Smartphone , Tomografia Computadorizada de Feixe Cônico Espiral/métodos , Cirurgia Assistida por Computador/métodos , Realidade Aumentada , Humanos
18.
Transl Lung Cancer Res ; 10(8): 3627-3644, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34584862

RESUMO

BACKGROUND: Endobronchial navigation is performed in a variety of ways, none of which are meeting all the clinicians' needs required to reach diagnostic success in every patient. We sought to characterize precurved and steerable guiding sheaths (GS) in endobronchial targeting for lung biopsy using cone beam computed tomography (CBCT) based augmented fluoroscopy (AF) image guidance. METHODS: Four precurved GS (EdgeTM 45, 90, 180, 180EW, Medtronic) and two steerable GS [6.5 F Destino Twist (DT), Oscor; 6 F Morph, BioCardia] were evaluated alone and in combination with an electromagnetic tracking (EM) guide and biopsy needles in three experimental phases: (I) bench model to assess GS deflection and perform biopsy simulations; (II) ex vivo swine lung comparing 2 steerable and 2 precurved GS; and (III) in vivo male swine lung to deliver a needle (n=2 swine) or to deliver a fiducial marker (n=2 swine) using 2 steerable GS. Ex vivo and in vivo image guidance was performed with either commercial or prototype AF image guidance software (Philips) based on either prior CT or procedural CBCT. Primary outcomes were GS delivery angle (θGS) and needle delivery angle (θN) in bench evaluation and needle delivery error (mm) (mean ± se) for ex vivo and in vivo studies. RESULTS: The steerable DT had the largest range of GS delivery angles (θN: 0-114°) with either the 21 G or 19 G biopsy needle in the bench model. In ex vivo swine lung, needle delivery errors were 8.7±0.9 mm (precurved Edge 90), 5.4±1.9 mm (precurved Edge 180), 4.7±1.2 mm (steerable DT), and 5.6±2.4 mm (steerable Morph). In vivo, the needle delivery errors for the steerable GS were 6.0±1.0 mm (DT) and 15±7.0 mm (Morph). In vivo marker coil delivery was successful for both the steerable DT and morph GS. A case report demonstrated successful needle biopsy with the steerable DT. CONCLUSIONS: Endobronchial needle delivery with AF guidance is feasible without a bronchoscope with steerable GS providing comparable or improved accuracy compared to precurved GS.

19.
Sci Rep ; 11(1): 6940, 2021 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-33767213

RESUMO

A better understanding of temporal relationships between chest CT and labs may provide a reference for disease severity over the disease course. Generalized curves of lung opacity volume and density over time can be used as standardized references from well before symptoms develop to over a month after recovery, when residual lung opacities remain. 739 patients with COVID-19 underwent CT and RT-PCR in an outbreak setting between January 21st and April 12th, 2020. 29 of 739 patients had serial exams (121 CTs and 279 laboratory measurements) over 50 ± 16 days, with an average of 4.2 sequential CTs each. Sequential volumes of total lung, overall opacity and opacity subtypes (ground glass opacity [GGO] and consolidation) were extracted using deep learning and manual segmentation. Generalized temporal curves of CT and laboratory measurements were correlated. Lung opacities appeared 3.4 ± 2.2 days prior to symptom onset. Opacity peaked 1 day after symptom onset. GGO onset was earlier and resolved later than consolidation. Lactate dehydrogenase, and C-reactive protein peaked earlier than procalcitonin and leukopenia. The temporal relationships of quantitative CT features and clinical labs have distinctive patterns and peaks in relation to symptom onset, which may inform early clinical course in patients with mild COVID-19 pneumonia, or may shed light upon chronic lung effects or mechanisms of medical countermeasures in clinical trials.


Assuntos
COVID-19/diagnóstico por imagem , Testes de Química Clínica , Testes Hematológicos , Tórax/diagnóstico por imagem , Adulto , COVID-19/sangue , COVID-19/virologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença , Tórax/patologia , Tomografia Computadorizada por Raios X
20.
Diagn Interv Radiol ; 27(1): 20-27, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32815519

RESUMO

PURPOSE: Chest X-ray plays a key role in diagnosis and management of COVID-19 patients and imaging features associated with clinical elements may assist with the development or validation of automated image analysis tools. We aimed to identify associations between clinical and radiographic features as well as to assess the feasibility of deep learning applied to chest X-rays in the setting of an acute COVID-19 outbreak. METHODS: A retrospective study of X-rays, clinical, and laboratory data was performed from 48 SARS-CoV-2 RT-PCR positive patients (age 60±17 years, 15 women) between February 22 and March 6, 2020 from a tertiary care hospital in Milan, Italy. Sixty-five chest X-rays were reviewed by two radiologists for alveolar and interstitial opacities and classified by severity on a scale from 0 to 3. Clinical factors (age, symptoms, comorbidities) were investigated for association with opacity severity and also with placement of central line or endotracheal tube. Deep learning models were then trained for two tasks: lung segmentation and opacity detection. Imaging characteristics were compared to clinical datapoints using the unpaired student's t-test or Mann-Whitney U test. Cohen's kappa analysis was used to evaluate the concordance of deep learning to conventional radiologist interpretation. RESULTS: Fifty-six percent of patients presented with alveolar opacities, 73% had interstitial opacities, and 23% had normal X-rays. The presence of alveolar or interstitial opacities was statistically correlated with age (P = 0.008) and comorbidities (P = 0.005). The extent of alveolar or interstitial opacities on baseline X-ray was significantly associated with the presence of endotracheal tube (P = 0.0008 and P = 0.049) or central line (P = 0.003 and P = 0.007). In comparison to human interpretation, the deep learning model achieved a kappa concordance of 0.51 for alveolar opacities and 0.71 for interstitial opacities. CONCLUSION: Chest X-ray analysis in an acute COVID-19 outbreak showed that the severity of opacities was associated with advanced age, comorbidities, as well as acuity of care. Artificial intelligence tools based upon deep learning of COVID-19 chest X-rays are feasible in the acute outbreak setting.


Assuntos
COVID-19/diagnóstico , Aprendizado Profundo/estatística & dados numéricos , Radiografia Torácica/métodos , SARS-CoV-2/genética , Tórax/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , COVID-19/epidemiologia , COVID-19/terapia , COVID-19/virologia , Comorbidade , Estudos de Viabilidade , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Radiografia Torácica/classificação , Radiologistas , Estudos Retrospectivos , Índice de Gravidade de Doença , Tórax/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA