RESUMO
BACKGROUND: The benefit of percutaneous coronary intervention (PCI) in patients with stable coronary artery disease and severe aortic stenosis who are undergoing transcatheter aortic-valve implantation (TAVI) remains unclear. METHODS: In an international trial, we randomly assigned, in a 1:1 ratio, patients with severe symptomatic aortic stenosis and at least one coronary-artery stenosis with a fractional flow reserve of 0.80 or less or a diameter stenosis of at least 90% either to undergo PCI or to receive conservative treatment, with all patients also undergoing TAVI. The primary end point was a major adverse cardiac event, defined as a composite of death from any cause, myocardial infarction, or urgent revascularization. Safety, including bleeding events and procedural complications, was assessed. RESULTS: A total of 455 patients underwent randomization: 227 to the PCI group and 228 to the conservative-treatment group. The median age of the patients was 82 years (interquartile range, 78 to 85), and the median Society of Thoracic Surgeons-Procedural Risk of Mortality score (on a scale from 0 to 100%, with higher scores indicating a greater risk of death within 30 days after the procedure) was 3% (interquartile range, 2 to 4). At a median follow-up of 2 years (interquartile range, 1 to 4), a major adverse cardiac event (primary end point) had occurred in 60 patients (26%) in the PCI group and in 81 (36%) in the conservative-treatment group (hazard ratio, 0.71; 95% confidence interval [CI], 0.51 to 0.99; P = 0.04). A bleeding event occurred in 64 patients (28%) in the PCI group and in 45 (20%) in the conservative-treatment group (hazard ratio, 1.51; 95% CI, 1.03 to 2.22). In the PCI group, 7 patients (3%) had PCI procedure-related complications. CONCLUSIONS: Among patients with coronary artery disease who were undergoing TAVI, PCI was associated with a lower risk of a composite of death from any cause, myocardial infarction, or urgent revascularization at a median follow-up of 2 years than conservative treatment. (Funded by Boston Scientific and the Danish Heart Foundation; NOTION-3 ClinicalTrials.gov number, NCT03058627.).
RESUMO
BACKGROUND: Most patients undergoing the mitral transcatheter edge-to-edge repair (TEER) technique are elderly comorbid patients. Low body mass index (BMI) < 23 kg/m2 has been identified in other elderly populations as a risk factor, but has not been studied sufficiently in mitral TEER. AIMS: We aimed to study the impact of low BMI (23 kg/m2) on the outcome after mitral TEER. METHODS: Patients undergoing first-time TEER for mitral regurgitation at a single tertiary center were included, with the exclusion of patients with preprocedural hemodynamic instability or missing BMI. The primary endpoint was all-cause mortality. Secondary endpoints were long-term major bleeding or admission with heart failure. RESULTS: A total of 120 patients (mean age 76 ± 10 years, 76% men) were included in the study. Thirty-nine (31%) had low BMI. Patients with low BMI had a similar symptomatic benefit as patients with BMI ≥ 23 kg/m2 at 1 year regarding decrease in diuretics dose and decrease in New York Heart Association (NYHA) class (p > 0.05). In a multivariable Cox regression analysis, BMI as a continuous variable (hazard ratio [HR]: 0.93 [95% confidence interval, CI: 0.87-0.99], p = 0.03) and low BMI (HR: 1.99 [95% CI: 1.12-3.52], p = 0.02) were associated with the primary outcome. Low BMI was not significantly associated with major bleeding (subdistribution hazard ratio [SHR]: 2.39 [95% CI: 0.96-5.97], p = 0.06) or admission with heart failure (SHR: 1.06 [95% CI: 0.61-1.88], p = 0.83) during follow-up with univariable competing risk regression analysis. CONCLUSION: Low BMI is a risk factor for mortality after mitral valve TEER, confirming the presence of an "obesity paradox" in this population and should receive attention in patient selection.
Assuntos
Índice de Massa Corporal , Cateterismo Cardíaco , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Feminino , Masculino , Fatores de Risco , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Fatores de Tempo , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Medição de Risco , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos , Magreza/mortalidade , Magreza/diagnóstico , Magreza/fisiopatologia , Magreza/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Hemorragia/mortalidade , Obesidade/mortalidade , Obesidade/diagnóstico , Obesidade/complicações , Obesidade/fisiopatologiaRESUMO
BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.
Assuntos
Síndrome Coronariana Aguda , Ácidos Alcanossulfônicos , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Trombose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Fatores de Risco , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Implantes Absorvíveis , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos , Trombose Coronária/etiologia , Stents/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversosRESUMO
BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).
Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidadeRESUMO
BACKGROUND: Chronic total occlusions (CTO) are frequent among patients with coronary artery disease. Revascularization with percutaneous coronary intervention (PCI) is safe and feasible in experienced hands. However, randomized data are needed to demonstrate symptomatic as well as prognostic effect of CTO-PCI compared to optimal medical therapy alone. METHODS: This trial aims to evaluate the effect of CTO PCI in patients with a CTO lesion and target vessel diameter ≥ 2.5 mm, and myocardial ischemia in the relevant territory. First, all patients are subjected to optimal medical therapy (OMT) for at least for 3 months and non-CTO lesions are managed according to guidelines. Subsequently, prior to randomization myocardial ischemia and quality of life (Seattle Questionnaire (SAQ)) is assessed. Patients are divided into two cohorts based on their SAQ score and randomized to either OMT alone or OMT and CTO-PCI. Cohort A is defined as Low- or asymptomatic patients with a quality-of-life score > 60 and/or CCS class < 2, and more than 10 % ischemia in the left ventricle (LV). Cohort B is symptomatic patients with a quality-of-life score < 60 or CCS class angina > 1 and at least ischemia in 5% of the LV. The primary end-point in cohort A is a composite of major adverse cardiac and cerebral events, hospitalization for heart failure and malignant ventricular arrhythmias. The primary endpoint in cohort B is difference in quality of life 6 months after randomization. IMPLICATIONS: This trial is designed to investigate if CTO-PCI improves QoL and MACCE. Both positive and negative outcome of the trial will affect future guidelines and recommendations on how to treat patients with CTO.
Assuntos
Doença da Artéria Coronariana , Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/cirurgia , Doença da Artéria Coronariana/etiologia , Qualidade de Vida , Intervenção Coronária Percutânea/efeitos adversos , Angina Pectoris/etiologia , Doença Crônica , Resultado do TratamentoRESUMO
BACKGROUND: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. STUDY DESIGN: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. SUMMARY: NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.
Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Constrição Patológica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Angiografia CoronáriaRESUMO
OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.
Assuntos
Síndrome Coronariana Aguda , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Doença da Artéria Coronariana/terapia , Fatores de Risco , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Fatores de Tempo , Desenho de Prótese , Infarto do Miocárdio/etiologia , Stents Farmacológicos/efeitos adversosRESUMO
BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.
Assuntos
Antibacterianos/uso terapêutico , Antígenos CD34/metabolismo , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Idoso , Antibacterianos/farmacologia , Feminino , Humanos , Masculino , Sirolimo/farmacologia , Resultado do TratamentoRESUMO
This sub-study of the SORT OUT IX trial sought to compare clinical outcomes between patients with diabetes randomized to implantation of either the polymer-free biolimus A9-coated BioFreedom stent (BF-BES) or the ultra-thin strut, biodegradable polymer sirolimus-eluting Orsiro stent (O-SES). Patients with diabetes have an increased risk of target lesion failure (TLF) after percutaneous coronary intervention (PCI). The impact of different stent types in patients with diabetes is still discussed. A total of 607 of the 3151 patients (19.3%) enrolled in the SORT OUT IX study had diabetes. Randomization was stratified by patients with/without diabetes; 304 received BF-BES and 303 O-SES. The primary endpoint was TLF, which was a composite of cardiac death, myocardial infarction (not related to other than the index lesion) and target lesion revascularization (TLR) within 1 year. After 1 year, patients with diabetes had higher TLF (7.2% vs. 3.7%, incidence rate ratio [IRR]: 1.65; 95% confidence interval [CI]: 1.08-2.50), than patients without diabetes. TLF did not differ significantly between BF-BES and O-SES in patients with diabetes (8.2% vs. 6.3%, IRR: 1.17; 95% CI: 0.63-2.20). In patients with diabetes, cardiac death occurred in 2.3% of BF-BES and in 3.6% of O-SES (IRR: 0.58; 95% CI: 0.23-1.45) and TLR occurred in 5.3% and 2.3% of BF-BES and O-SES, respectively (IRR: 2.12; 95% CI: 0.81-5.56). Definite stent thrombosis rates of 1.3% were found in both stent types. Patients with diabetes had higher 1-year TLF rate after PCI compared to patients without diabetes, whereas TLF did not differ significantly between the two stent types BF-BES and O-SES in patients with diabetes.
Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Morte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do TratamentoRESUMO
OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.
Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Implantes Absorvíveis , Antígenos CD34/imunologia , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Morte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo/efeitos adversos , Stents , Resultado do TratamentoRESUMO
BACKGROUND: In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention. METHODS: The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021. RESULTS: Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%]; Pnoninferiority=0.14). Significantly more patients in the BioFreedom stent group had target lesion revascularization than those in the Orsiro stent group (55 [3.5%] vs 20 [1.3%], rate ratio 2.77 [95% CI, 1.66-4.62]; P<0.0001). CONCLUSIONS: The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140.
Assuntos
Implantes Absorvíveis , Anti-Inflamatórios , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared. BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention. METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years. RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95). CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.
Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do TratamentoRESUMO
Current guidelines do not recommend coronary computed tomography angiography (CCTA) in patients with high levels of coronary calcium, as severe calcification leads to difficulties in estimating stenosis severity due to blooming artifacts obscuring the vessel lumen. Whether the CCTA-derived fractional flow reserve (FFRCT) improves the diagnostic performance of CCTA in patients with high levels of coronary calcification has not been sufficiently evaluated. We hypothesize that a noninvasive diagnostic strategy using FFRCT will perform comparably to an invasive diagnostic strategy in the detection of hemodynamically significant coronary artery disease (CAD) in clinical stable chest pain patients with high levels of coronary calcium. In this prospective, blinded, multicenter study, patients with suspected stable CAD referred for CCTA and demonstrating an Agatston score >399 will be included. Patients accepting inclusion will, in addition to CCTA, undergo invasive coronary angiography (ICA) and invasive FFR measurement. FFRCT analyses are performed by an external core laboratory blinded to any patient data, and the FFRCT results are blinded to all participating study sites. The primary objective is to evaluate whether FFRCT can identify patients with and without hemodynamically significant CAD, when ICA with FFR is the reference standard. A negative study result would question the clinical usefulness of FFRCT in patients with high levels of coronary calcium. A positive study result, however, would imply a reduction in the number of patients referred for coronary catheterization and, at the same time, increase the proportion of patients with hemodynamically significant CAD at the subsequent invasive examination.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Calcificação Vascular/diagnóstico por imagem , Cálcio/sangue , Cateterismo Cardíaco , Dor no Peito/etiologia , Doença da Artéria Coronariana/fisiopatologia , Dinamarca , Hemodinâmica , Humanos , Estudos Multicêntricos como Assunto , Valor Preditivo dos Testes , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Calcificação Vascular/fisiopatologiaRESUMO
BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448. FINDINGS: Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months. INTERPRETATION: The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients. FUNDING: Medtronic Cardiovascular and Biosensors Interventional Technologies.
Assuntos
Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Implantes Absorvíveis , Idoso , Materiais Revestidos Biocompatíveis , Dinamarca , Desenho de Equipamento , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/mortalidade , Polímeros , Sirolimo/administração & dosagem , Resultado do TratamentoRESUMO
BACKGROUND: Cardiac 15 O-water PET is a noninvasive method to evaluate epicardial and microvascular dysfunction and further quantitate absolute myocardial blood flow (MBF). AIM: The aim of this study was to assess the impact of revascularization on MBF and myocardial flow reserve (MFR) assessed with 15 O-water PET and invasive flow and pressure measurements. METHODS: In 21 patients with single-vessel disease referred for percutaneous coronary intervention (PCI), serial PET perfusion imaging and fractional flow reserve (FFR), coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) were performed during PCI and after 3 months. RESULTS: In the affected myocardium, stress MBF and MFR increased significantly from before revascularization to 3 months after revascularization: stress MBF 2.4â ±â 0.8 vs. 3.2â ±â 0.8; P â <â 0.001 and MFR 2.5â ±â 0.8 vs. 3.4â ±â 1.1; P â =â 0.004. FFR and CFR increased significantly from baseline to after revascularization and remained stable from after revascularization to 3-month follow-up: FFR 0.64â ±â 0.20 vs. 0.91â ±â 0.06 vs. 0.91â ±â 0.07; P â <â 0.001; CFR 2.4â ±â 1.2 vs. 3.6â ±â 1.9 vs. 3.6â ±â 1.9; P â <â 0.001, whereas IMR did not change significantly: 30.3â ±â 22.9 vs. 30.1â ±â 25.3 vs. 31.9â ±â 25.2; P â =â ns. After revascularization, an increase in stress MBF was associated with an increase in FFR ( r â =â 0.732; P â <â 0.001) and an increase in MFR ( r â =â 0.499; P â =â 0.021). IMR measured before PCI was inversely associated with improvement in stress MBF, ( r â =â -0.616; P â =â 0.004). CONCLUSION: Recovery of myocardial perfusion after PCI was associated with an increase in FFR 3 months after revascularization. Microcirculatory dysfunction was associated with less improvement in myocardial perfusion.
Assuntos
Angina Estável , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Microcirculação/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Angina Estável/etiologia , Água , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologiaRESUMO
Introduction: Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods: The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results: Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion: The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.
RESUMO
BACKGROUND: Diabetes mellitus is associated with higher risk of target lesion failure (TLF) after percutaneous coronary intervention. We studied the 5-year outcome in patients with diabetes mellitus treated with biodegradable polymer stents. METHODS: The SORT OUT VII was a randomised trial comparing the ultrathin sirolimus-eluting Orsiro stent (O-SES) and the biolimus-eluting Nobori stent (N-BES) in an all-comer setting. Patients (n = 2525) were randomised to receive O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). Endpoints were TLF (a composite of cardiac death, target-lesion myocardial infarction (MI), target lesion revascularization (TLR)), definite stent thrombosis and a patient related outcome (all-cause mortality, MI and revascularization) within 5 years. RESULTS: Patients with diabetes mellitus had higher TLF (20.6% vs 11.0%, (Rate ratio (RR) 1.85 95% confidence interval (CI): (1.42-2.40) and patient related outcome (42.0% vs 31.0%, RR 1.43 95% CI: (1.19-1.71)) compared to patients without diabetes. Among patients with diabetes mellitus, TLF after 5 years did not differ between O-SES and N-BES (21.2% vs 20.0%), RR 1.05 95% CI: (0.70-1.58), p = 0.81). Cardiac death, MI, TLR, and definite stent thrombosis did not differ between the groups. CONCLUSION: In patients with diabetes mellitus, 5-year outcomes were similar among patients treated with biodegradable polymer O-SES or N-BES. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01879358.
Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Fatores de Risco , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Polímeros , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Infarto do Miocárdio/mortalidadeRESUMO
In-stent restenosis (ISR) still occur after percutaneous coronary intervention (PCI). Few studies have compared outcomes after PCI for de novo stenosis and ISR and the results are conflicting. The aim of the present study is to compare outcomes after PCI for ISR and de novo coronary stenosis. Using patient level data from the randomized all-comer SORT OUT studies III-X, we included all patients with previous PCI and either an ISR or a de novo lesion as the study target lesion. Outcomes of interest were major adverse cardiac events (MACE) and target lesion revascularization (TLR) after 5 years. Of the 2928 patients with a previous PCI included in the SORT OUT studies, 491 (17%) were treated for ISR and 2437 (83%) for a de novo stenosis. Baseline characteristics did not differ significantly. At 5 years, MACE occurred in 148 patients (32%) in the ISR group and in 654 patients (28%) in the de novo stenosis group (Crude and adjusted HR 1.16 (0.97-1.38) and 1.16 (0.97-1.38)). The risk of TLR was higher in the ISR group when compared to the de novo stenosis group (Crude and adjusted HR 1.64 (95% CI, 1.24-2.17) and 1.71 (95% CI, 1.27-2.30)). In conclusion, the risk of MACE was similar after PCI of ISR and de novo lesions after 5 years. However, the risk of TLR was higher in the ISR group compared to the de novo stenosis group.
RESUMO
Coronary CT angiography (CTA) derived fractional flow reserve (FFRCT) is recommended for physiological assessment in intermediate coronary stenosis for guiding referral to invasive coronary angiography (ICA). In this study, we report real-world data on the feasibility of implementing a CTA/FFRCT test algorithm as a gatekeeper to ICA at referral hospitals. Retrospective all-comer study of patients with new onset stable symptoms and suspected coronary stenosis (30-89%) by CTA. Evaluation of CTA datasets, interpretation of FFRCT analysis, and decisions on downstream testing were performed by skilled CT-cardiologists. CTA was performed in 3974 patients, of whom 381 (10%) were referred directly to ICA, whereas 463 (12%) to non-invasive functional testing: FFRCT 375 (81%) and perfusion imaging 88 (19%). FFRCT analysis was rejected in 8 (2%) due to inadequate CTA image quality. Number of patients deferred from ICA after FFRCT was 267 (71%), while 100 (27%) were referred to ICA. Obstructive coronary artery disease (CAD) was confirmed in 62 (62%) patients and revascularization performed in 53 (53%). Revascularization rates, n (%), were higher in patients undergoing FFRCT-guided versus CTA-guided referral to ICA: 30-69% stenosis, 28 (44%) versus 8 (21%); 70-89% stenosis, 39 (69%) versus 25 (46%), respectively, both p < 0.05. Implementation of FFRCT at referral hospitals was feasible, reduced the number of invasive procedures, and increased the revascularization rate.
Assuntos
Angina Estável , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Estudos de Viabilidade , Reserva Fracionada de Fluxo Miocárdico , Valor Preditivo dos Testes , Encaminhamento e Consulta , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angina Estável/fisiopatologia , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Imagem de Perfusão do Miocárdio/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Algoritmos , Prognóstico , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Índice de Gravidade de Doença , Revascularização MiocárdicaRESUMO
Background: Pulmonary embolism (PE) is common, and it is the third leading cause of cardiovascular death. The management of patients with high-risk PE generally consists of systemic thrombolysis; however, surgical or catheter-directed treatment (CDT) can be considered in selected cases. Case summary: A 78-year-old female patient presenting with acute severe dyspnoea develops out-of-hospital cardiac arrest (OHCA). She was admitted with return of spontaneous circulation and a critical haemodynamic state upon arrival to the catheterization laboratory with an estimated no-flow time of 1â min and low-flow time of 52â min. An acute pulmonary angiogram reveals massive PE. After a PE response team conference, the patient was not found eligible for extracorporeal membrane oxygenation, surgery, or thrombolysis. The patient was treated with catheter-directed mechanical thrombectomy 129â min after first medical contact. The patient recovered and was discharged without any neurological deficits. Discussion: Catheter-directed mechanical thrombectomy was a successful treatment in a patient with OHCA secondary to high-risk PE, where thrombolysis and surgical interventions were considered contraindicated. This case underlines the future perspectives of CDT and also that a multidisciplinary team approach may benefit patients with high-risk PE.