Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Environ Monit Assess ; 193(5): 307, 2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33909163

RESUMO

Metal and metalloid contamination in drinking water sources is a global concern, particularly in developing countries. This study used hollow membrane water filters and metal-capturing polyurethane foams to sample 71 drinking water sources in 22 different countries. Field sampling was performed with sampling kits prepared in the lab at Hope College in Holland, MI, USA. Filters and foams were sent back to the lab after sampling, and subsequent analysis of flushates and rinsates allowed the estimation of suspended solids and metal and other analayte concentrations in source waters. Estimated particulate concentrations were 0-92 mg/L, and consisted of quartz, feldspar, and clay, with some samples containing metal oxides or sulfide phases. As and Cu were the only analytes which occurred above the World Health Organization (WHO) guidelines of 10 µg/L and 2000 µg/L, respectively, with As exceeding the guideline in 45% of the sources and Cu in 3%. Except for one value of ~ 285 µg/L, As concentrations were 45-200 µg/L (river), 65-179 µg/L (well), and 112-178 µg/L (tap). Other metals (Ce, Fe, Mg, Mn, Zn) with no WHO guideline were also detected, with Mn the most common. This study demonstrated that filters and foams can be used for reconnaissance characterization of untreated drinking water. However, estimated metal and other analyte concentrations could only be reported as minimum values due to potential incomplete retrieval of foam-bound analytes. A qualitative reporting methodology was used to report analytes as "present" if the concentration was below the WHO guideline, and "present-recommend retesting" if the concentration was quantifiable and above the WHO guideline.


Assuntos
Água Potável , Metaloides , Metais Pesados , Poluentes Químicos da Água , Monitoramento Ambiental , Humanos , Metaloides/análise , Metais Pesados/análise , Países Baixos , Poluentes Químicos da Água/análise
2.
Trop Med Health ; 49(1): 1, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33397511

RESUMO

BACKGROUND: Lack of sustainable access to clean drinking water continues to be an issue of paramount global importance, leading to millions of preventable deaths annually. Best practices for providing sustainable access to clean drinking water, however, remain unclear. Widespread installation of low-cost, in-home, point of use water filtration systems is a promising strategy. METHODS: We conducted a prospective, randomized, controlled trial whereby 16 villages were selected and randomly assigned to one of four treatment arms based on the installation location of Sawyer® PointONE™ filters (filter in both home and school; filter in home only; filter in school only; control group). Water samples and self-reported information on diarrhea were collected at multiple times throughout the study. RESULTS: Self-reported household prevalence of diarrhea decreased from 25.6 to 9.76% from installation to follow-up (at least 7 days, and up to 200 days post-filter installation). These declines were also observed in diarrhea with economic or educational consequences (diarrhea which led to medical treatment and/or missing school or work) with baseline prevalence of 9.64% declining to 1.57%. Decreases in diarrhea prevalence were observed across age groups. There was no evidence of a loss of efficacy of filters up to 200 days post-filter installation. Installation of filters in schools was not associated with decreases in diarrhea prevalence in school-aged children or family members. Unfiltered water samples both at schools and homes contained potential waterborne bacterial pathogens, dissolved heavy metals and metals associated with particulates. All dissolved metals were detected at levels below World Health Organization action guidelines. CONCLUSIONS: This controlled trial provides strong evidence of the effectiveness of point-of-use, hollow fiber membrane filters at reducing diarrhea from bacterial sources up to 200 days post-installation when installed in homes. No statistically significant reduction in diarrhea was found when filters were installed in schools. Further research is needed in order to explore filter efficacy and utilization after 200 days post-installation. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03972618 . Registered 3 June 2019-retrospectively registered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA