Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(4): 2426-2436, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37831139

RESUMO

OBJECTIVES: Coronary computed tomography angiography (CCTA) has higher diagnostic accuracy than coronary artery calcium (CAC) score for detecting obstructive coronary artery disease (CAD) in patients with stable chest pain, while the added diagnostic value of combining CCTA with CAC is unknown. We investigated whether combining coronary CCTA with CAC score can improve the diagnosis of obstructive CAD compared with CCTA alone. METHODS: A total of 2315 patients (858 women, 37%) aged 61.1 ± 10.2 from 29 original studies were included to build two CAD prediction models based on either CCTA alone or CCTA combined with the CAC score. CAD was defined as at least 50% coronary diameter stenosis on invasive coronary angiography. Models were built by using generalized linear mixed-effects models with a random intercept set for the original study. The two CAD prediction models were compared by the likelihood ratio test, while their diagnostic performance was compared using the area under the receiver-operating-characteristic curve (AUC). Net benefit (benefit of true positive versus harm of false positive) was assessed by decision curve analysis. RESULTS: CAD prevalence was 43.5% (1007/2315). Combining CCTA with CAC improved CAD diagnosis compared with CCTA alone (AUC: 87% [95% CI: 86 to 89%] vs. 80% [95% CI: 78 to 82%]; p < 0.001), likelihood ratio test 236.3, df: 1, p < 0.001, showing a higher net benefit across almost all threshold probabilities. CONCLUSION: Adding the CAC score to CCTA findings in patients with stable chest pain improves the diagnostic performance in detecting CAD and the net benefit compared with CCTA alone. CLINICAL RELEVANCE STATEMENT: CAC scoring CT performed before coronary CTA and included in the diagnostic model can improve obstructive CAD diagnosis, especially when CCTA is non-diagnostic. KEY POINTS: • The combination of coronary artery calcium with coronary computed tomography angiography showed significantly higher AUC (87%, 95% confidence interval [CI]: 86 to 89%) for diagnosis of coronary artery disease compared to coronary computed tomography angiography alone (80%, 95% CI: 78 to 82%, p < 0.001). • Diagnostic improvement was mostly seen in patients with non-diagnostic C. • The improvement in diagnostic performance and the net benefit was consistent across age groups, chest pain types, and genders.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Feminino , Humanos , Masculino , Cálcio , Dor no Peito/diagnóstico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Idoso
2.
Eur Radiol ; 32(8): 5233-5245, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35267094

RESUMO

OBJECTIVES: There is conflicting evidence about the comparative diagnostic accuracy of the Agatston score versus computed tomography angiography (CTA) in patients with suspected obstructive coronary artery disease (CAD). PURPOSE: To determine whether CTA is superior to the Agatston score in the diagnosis of CAD. METHODS: In total 2452 patients with stable chest pain and a clinical indication for invasive coronary angiography (ICA) for suspected CAD were included by the Collaborative Meta-analysis of Cardiac CT (COME-CCT) Consortium. An Agatston score of > 400 was considered positive, and obstructive CAD defined as at least 50% coronary diameter stenosis on ICA was used as the reference standard. RESULTS: Obstructive CAD was diagnosed in 44.9% of patients (1100/2452). The median Agatston score was 74. Diagnostic accuracy of CTA for the detection of obstructive CAD (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) was significantly higher than that of the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). Among patients with an Agatston score of zero, 17% (101/600) had obstructive CAD. Diagnostic accuracy of CTA was not significantly different in patients with low to intermediate (1 to < 100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). CONCLUSIONS: Results in our international cohort show CTA to have significantly higher diagnostic accuracy than the Agatston score in patients with stable chest pain, suspected CAD, and a clinical indication for ICA. Diagnostic performance of CTA is not affected by a higher Agatston score while an Agatston score of zero does not reliably exclude obstructive CAD. KEY POINTS: • CTA showed significantly higher diagnostic accuracy (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) for diagnosis of coronary artery disease when compared to the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). • Diagnostic performance of CTA was not affected by increased amount of calcium and was not significantly different in patients with low to intermediate (1 to <100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). • Seventeen percent of patients with an Agatston score of zero showed obstructive coronary artery disease by invasive angiography showing absence of coronary artery calcium cannot reliably exclude coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Cálcio , Dor no Peito/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
3.
Entropy (Basel) ; 22(9)2020 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-33286775

RESUMO

Entropy is a quantitative measure of signal uncertainty and has been widely applied to ultrasound tissue characterization. Ultrasound assessment of hepatic steatosis typically involves a backscattered statistical analysis of signals based on information entropy. Deep learning extracts features for classification without any physical assumptions or considerations in acoustics. In this study, we assessed clinical values of information entropy and deep learning in the grading of hepatic steatosis. A total of 205 participants underwent ultrasound examinations. The image raw data were used for Shannon entropy imaging and for training and testing by the pretrained VGG-16 model, which has been employed for medical data analysis. The entropy imaging and VGG-16 model predictions were compared with histological examinations. The diagnostic performances in grading hepatic steatosis were evaluated using receiver operating characteristic (ROC) curve analysis and the DeLong test. The areas under the ROC curves when using the VGG-16 model to grade mild, moderate, and severe hepatic steatosis were 0.71, 0.75, and 0.88, respectively; those for entropy imaging were 0.68, 0.85, and 0.9, respectively. Ultrasound entropy, which varies with fatty infiltration in the liver, outperformed VGG-16 in identifying participants with moderate or severe hepatic steatosis (p < 0.05). The results indicated that physics-based information entropy for backscattering statistics analysis can be recommended for ultrasound diagnosis of hepatic steatosis, providing not only improved performance in grading but also clinical interpretations of hepatic steatosis.

4.
J Med Ultrasound ; 27(3): 130-134, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31867175

RESUMO

BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a popular modality to measure liver fibrosis. ARFI selects optimal locations for measurement under imaging guiding. However, there are concerns on study locations and observers bias. To decrease the variations, ARFI at two locations was measured with standardized protocol. This study attempted to establish its cutoff values according to Metavir fibrosis score in different etiologies. METHODS: A consecutive series of patients who received liver histology study were prospectively enrolled. All cases had hemogram, liver biochemistry, viral markers, and ARFI two-location measurements within 4 weeks of histology study. A standardized protocol was performed by single technologist. We excluded patients with alanine aminotransferase >5x upper limit normal. RESULTS: Five hundred and ten patients that included 153 seronegative for both HBsAg and anti-HCV Non-B non-C (NBNC), 33 autoimmune liver diseases (AILD), 261 chronic hepatitis B (CHB), and 63 chronic hepatitis C (CHC) were enrolled. About 83% of NBNC patients had fat cell >5%. For diagnosis of liver cirrhosis, the area under receiver operating characteristic curve of NBNC, AILD, CHB, and CHC groups was 0.937, 0.929, 0.784, and 0.937; the cutoff values for mean ARFI were 1.788, 2.095, 1.455, and 1.710 m/s, respectively. The sensitivity and specificity are both over 0.818 for patients with nonalcoholic fatty liver diseases, CHC, and AILD, but the corresponding data are only 0.727-0.756 in CHB. The Fibrosis-4 Score is as good as ARFI on fibrosis assessment in NBNC. CONCLUSION: The performance of ARFI two-location measurement is excellent in NBNC, AILD, and CHC, but is only satisfactory in CHB.

5.
Eur Radiol ; 28(9): 4006-4017, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29556770

RESUMO

OBJECTIVES: To analyse the implementation, applicability and accuracy of the pretest probability calculation provided by NICE clinical guideline 95 for decision making about imaging in patients with chest pain of recent onset. METHODS: The definitions for pretest probability calculation in the original Duke clinical score and the NICE guideline were compared. We also calculated the agreement and disagreement in pretest probability and the resulting imaging and management groups based on individual patient data from the Collaborative Meta-Analysis of Cardiac CT (CoMe-CCT). RESULTS: 4,673 individual patient data from the CoMe-CCT Consortium were analysed. Major differences in definitions in the Duke clinical score and NICE guideline were found for the predictors age and number of risk factors. Pretest probability calculation using guideline criteria was only possible for 30.8 % (1,439/4,673) of patients despite availability of all required data due to ambiguity in guideline definitions for risk factors and age groups. Agreement regarding patient management groups was found in only 70 % (366/523) of patients in whom pretest probability calculation was possible according to both models. CONCLUSIONS: Our results suggest that pretest probability calculation for clinical decision making about cardiac imaging as implemented in the NICE clinical guideline for patients has relevant limitations. KEY POINTS: • Duke clinical score is not implemented correctly in NICE guideline 95. • Pretest probability assessment in NICE guideline 95 is impossible for most patients. • Improved clinical decision making requires accurate pretest probability calculation. • These refinements are essential for appropriate use of cardiac CT.


Assuntos
Técnicas de Imagem Cardíaca , Dor no Peito/diagnóstico por imagem , Tomada de Decisão Clínica , Fidelidade a Diretrizes , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X , Adulto , Idoso , Dor no Peito/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Fatores de Risco
6.
Eur Radiol ; 28(11): 4919-4921, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29858635

RESUMO

The original version of this article, published on 19 March 2018, unfortunately contained a mistake. The following correction has therefore been made in the original: The names of the authors Philipp A. Kaufmann, Ronny Ralf Buechel and Bernhard A. Herzog were presented incorrectly.

8.
Histopathology ; 70(6): 986-999, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28032914

RESUMO

AIMS: To characterize the clinicopathological and genetic features of pleomorphic mantle cell lymphoma (PMCL), which morphologically mimics diffuse large B cell lymphoma (DLBCL). METHODS AND RESULTS: We screened systematically 500 B cell lymphomas morphologically compatible with DLBCL using an immunohistochemical algorithm of three markers (CD5, cyclin D1 and SOX11). Ten cases of PMCL were identified for further study and, surprisingly, four (40%) of them were cyclin D1-negative. These 10 patients were mainly elderly males with advanced disease, and their median survival was only 11 months. All cyclin D1-positive PMCLs tested showed an IGH-CCND1 translocation, whereas one of the four cyclin D1-negative PMCLs had a translocation involving CCND2 and a high CCND2 mRNA level (P < 0.000001). The genomewide copy number profiles of both cyclin D1-positive and cyclin D1-negative PMCLs were similar to those of classical mantle cell lymphoma (MCL) reported previously, confirming the diagnosis. Secondary genetic alterations involved in oncogenic pathways of MCL were observed more frequently in these PMCLs, possibly decreasing the dependence on the driving CCND1 translocation and accounting for the common cyclin D1 negativity. Copy number gains of PIK3CA and CCDC50 were detected in all cyclin D1-negative PMCLs but in only 40% of the cyclin D1-positive PMCLs. These additional oncogenic signals may compensate for the common absence of CCND2 translocation in cyclin D1-negative PMCL. CONCLUSION: We demonstrate for the first time that cyclin D1 negativity is surprisingly common in PMCL morphologically mimicking DLBCL, and the use of a simple immunohistochemical algorithm can prevent misclassification and inappropriate treatment.


Assuntos
Algoritmos , Biomarcadores Tumorais/análise , Imuno-Histoquímica/métodos , Linfoma Difuso de Grandes Células B/diagnóstico , Linfoma de Célula do Manto/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Classe I de Fosfatidilinositol 3-Quinases , Ciclina D1/biossíntese , Diagnóstico Diferencial , Feminino , Dosagem de Genes , Humanos , Hibridização in Situ Fluorescente , Peptídeos e Proteínas de Sinalização Intracelular/genética , Linfoma Difuso de Grandes Células B/genética , Linfoma de Célula do Manto/genética , Masculino , Pessoa de Meia-Idade , Fosfatidilinositol 3-Quinases/genética , Reação em Cadeia da Polimerase , Adulto Jovem
10.
J Med Syst ; 40(1): 33, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26563476

RESUMO

Fatty liver disease is a common disease caused by alcoholism, obesity, and diabetes, resulting in triglyceride accumulation in hepatocytes. Kurtosis coefficient, a measure of the peakedness of the probability distribution, has been applied to the analysis of backscattered statistics for characterizing fatty liver. This study proposed ultrasound kurtosis imaging as a computer-aided diagnosis (CAD) method to visually and quantitatively stage the fatty liver. A total of 107 patients were recruited to participate in the experiments. The livers were scanned using a clinical ultrasound scanner with a 3.5-MHz curved transducer to acquire the raw ultrasound backscattered signals for kurtosis imaging. The kurtosis image was constructed using the sliding window technique. Experimental results showed that kurtosis imaging has the ability to visualize and quantify the variation of backscattered statistics caused by fatty infiltration. The kurtosis coefficient corresponding to liver parenchyma decreased from 5.41 ± 0.89 to 3.68 ± 0.12 with increasing the score of fatty liver from 0 (normal) to 3 (severe), indicating that fatty liver reduces the degree of peakedness of backscattered statistics. The best performance of kurtosis imaging was found when discriminating between normal and fatty livers with scores ≥1: the area under the curve (AUC) is 0.92 at a cutoff value of 4.36 (diagnostic accuracy =86.9 %, sensitivity =86.7 %, specificity =87.0 %). The current findings suggest that kurtosis imaging may be useful in designing CAD tools to assist in physicians in early detection of fatty liver.


Assuntos
Diagnóstico por Computador/métodos , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/diagnóstico , Modelos Estatísticos , Fígado Gorduroso/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Ultrassonografia
11.
J Ultrasound Med ; 34(5): 813-21, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25911714

RESUMO

OBJECTIVES: The purpose of this study was to evaluate liver fibrosis by acoustic radiation force impulse (ARFI) measurements at 2 locations in patients with chronic hepatitis B and C. METHODS: A total of 204 consecutive patients (146 male and 58 female) with chronic hepatitis B (n = 121) and C (n = 83) who underwent liver biopsy were enrolled. All patients received ARFI measurements at 2 locations in the right intercostal space on the same day as biopsy. RESULTS: There was no difference in median ARFI values between detection locations. However, a significant difference was found for low and high values between locations (median ± SD, 1.38 ± 0.43 versus 1.56 ± 0.55 m/s; P < .001). By receiver operating characteristic (ROC) curve analysis for a METAVIR fibrosis score of F4 (cirrhosis), the lower value of 2 measurements had the highest area under the ROC curve (0.750), followed by the mean value (0.744) and the higher value (0.730). Patients with hepatitis C had a higher area under the ROC curve than patients with hepatitis B (0.824 versus 0.707) for predicting liver cirrhosis. By logistic regression analysis, ARFI was the best modality for predicting liver cirrhosis in hepatitis C, and conventional sonography was the best modality in hepatitis B (P < .001). The ARFI value in patients with hepatitis B was significantly influenced by liver inflammation (P = .019). CONCLUSIONS: Acoustic radiation force impulse imaging is the modality of choice for predicting liver cirrhosis in chronic hepatitis C, whereas conventional sonography is still the modality of choice in chronic hepatitis B.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/diagnóstico por imagem , Hepatite C Crônica/diagnóstico por imagem , Aumento da Imagem/métodos , Cirrose Hepática/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Hepatite B Crônica/complicações , Hepatite C Crônica/complicações , Humanos , Cirrose Hepática/etiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Eur Radiol ; 24(10): 2394-403, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24928280

RESUMO

PURPOSE: To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). MATERIALS AND METHODS: CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically. RESULTS: One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings. CONCLUSION: CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study. KEY POINTS: • DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Mamografia/métodos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
J Formos Med Assoc ; 113(2): 124-32, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24530246

RESUMO

BACKGROUND/PURPOSE: The 64-slice multidetector CT (64-MDCT) has bolstered the sensitivity and specificity of coronary CT angiography (CCTA) for detecting coronary artery disease. We performed this study to understand the current status of CCTA using 64-MDCT, so as to determine further promotion and optimal regulation schemes of CCTA in Taiwan. METHODS: Information about CCTA from 68 domestic hospitals with 64-MDCT was collected by means of a questionnaire from July 2009 to January 2010. The studied details included: (1) the implementation background of CCTA; (2) the interdisciplinary cooperation and report processing of CCTA; and (3) the promotion strategy of CCTA. RESULTS: The majority of CCTA sites (89.7%) were administered by diagnostic radiologists. Most cardiologists and cardiac surgeons have confirmed its clinical value by referring patients to undergo CCTA. Of the CCTA reports by radiologists, 41.2% had their report supplemented by referring cardiologists. Such cooperation amongst specialists promoted the development of CCTA. Of CCTA studies, 89.7% included coronary calcium scoring. Most (60.3%) respondents asserted the cost of a study to be 15,000 to 20,000 new Taiwan dollars. Nearly two-fifths (41.2%) of the respondents supported the restriction of subjects for CCTA to those who were high risk group for coronary artery disease or those > 40 years of age. CONCLUSION: Diagnostic radiologists are primarily in charge of managing CCTA sites in Taiwan. The interdisciplinary cooperation amongst radiologists and cardiologists in reporting CCTA may expedite the development of CCTA. The domestic radiologists are expected to standardize the process, which includes interpreting and reporting CCTA findings.


Assuntos
Angiografia Coronária/métodos , Angiografia Coronária/estatística & dados numéricos , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Inquéritos e Questionários , Taiwan
14.
J Thorac Imaging ; 39(2): 111-118, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982516

RESUMO

PURPOSE: To assess the correlation of coronary calcium score (CS) obtained by artificial intelligence (AI) with those obtained by electrocardiography gated standard cardiac computed tomography (CCT) and nongated chest computed tomography (ChCT) with different reconstruction kernels. PATIENTS AND METHODS: Seventy-six patients received standard CCT and ChCT simultaneously. We compared CS obtained in 4 groups: CS CCT , by the traditional method from standard CCT, 25 cm field of view, 3 mm slice thickness, and kernel filter convolution 12 (FC12); CS AICCT , by AI from the standard CCT; CS ChCTsoft , by AI from the non-gated CCT, 40 cm field of view, 3 mm slice thickness, and a soft kernel FC02; and CS ChCTsharp , by AI from CCT image with same parameters for CS ChCTsoft except for using a sharp kernel FC56. Statistical analyses included Spearman rank correlation coefficient (ρ), intraclass correlation (ICC), Bland-Altman plots, and weighted kappa analysis (κ). RESULTS: The CS AICCT was consistent with CS CCT (ρ = 0.994 and ICC of 1.00, P < 0.001) with excellent agreement with respect to cardiovascular (CV) risk categories of the Agatston score (κ = 1.000). The correlation between CS ChCTsoft and CS ChCTsharp was good (ρ = 0.912, 0.963 and ICC = 0.929, 0.948, respectively, P < 0.001) with a tendency of underestimation (Bland-Altman mean difference and 95% upper and lower limits of agreements were 329.1 [-798.9 to 1457] and 335.3 [-651.9 to 1322], respectively). The CV risk category agreement between CS ChCTsoft and CS ChCTsharp was moderate (κ = 0.556 and 0.537, respectively). CONCLUSIONS: There was an excellent correlation between CS CCT and CS AICCT , with excellent agreement between CV risk categories. There was also a good correlation between CS CCT and CS obtained by ChCT albeit with a tendency for underestimation and moderate accuracy in terms of CV risk assessment.


Assuntos
Inteligência Artificial , Doença da Artéria Coronariana , Humanos , Cálcio , Tomografia Computadorizada por Raios X/métodos , Medição de Risco , Reprodutibilidade dos Testes , Angiografia Coronária/métodos
15.
Ultrasonography ; 43(3): 179-192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38589285

RESUMO

The retroperitoneum is an important space in the human body that is often implicated in a range Epub ahead of print of acute medical conditions, some of which can be life-threatening. Ultrasonography may serve as a pivotal first-line imaging technique when assessing patients with suspected retroperitoneal abnormalities. Effective ultrasonography of the retroperitoneum requires a comprehensive grasp of its anatomy, adjacent structures, and potential pathologies. Being well-acquainted with the imaging characteristics of acute conditions can meaningfully assist in an accurate diagnosis and guide subsequent management. This review article summarizes and illustrates the acute conditions involving the retroperitoneum through the lens of ultrasound imaging.

16.
Korean J Radiol ; 25(5): 459-472, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38685736

RESUMO

Hyperpolarized (HP) carbon-13 (13C) MRI represents an innovative approach for noninvasive, real-time assessment of dynamic metabolic flux, with potential integration into routine clinical MRI. The use of [1-13C]pyruvate as a probe and its conversion to [1-13C]lactate constitute an extensively explored metabolic pathway. This review comprehensively outlines the establishment of HP 13C-MRI, covering multidisciplinary team collaboration, hardware prerequisites, probe preparation, hyperpolarization techniques, imaging acquisition, and data analysis. This article discusses the clinical applications of HP 13C-MRI across various anatomical domains, including the brain, heart, skeletal muscle, breast, liver, kidney, pancreas, and prostate. Each section highlights the specific applications and findings pertinent to these regions, emphasizing the potential versatility of HP 13C-MRI in diverse clinical contexts. This review serves as a comprehensive update, bridging technical aspects with clinical applications and offering insights into the ongoing advancements in HP 13C-MRI.


Assuntos
Isótopos de Carbono , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Ácido Pirúvico
17.
Virchows Arch ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733379

RESUMO

Cyclin D1 protein-positive diffuse large B cell lymphoma (DLBCL) has an immunophenotype of CD5(-) cyclin D1(+) SOX11(-), and most cases lack a CCND1 rearrangement and have a gene expression profile of DLBCL. Rarely, cyclin D1 protein-positive DLBCL harbors a CCND1 rearrangement, and some genetic copy number features typical of mantle cell lymphoma (MCL) have been detected. Since gene expression studies have not been performed, whether such CCND1-rearranged cases represent cyclin D1 protein-positive DLBCL or CD5/SOX11 double-negative pleomorphic MCL remains unclear. To date, no cases of CD5/SOX11 double-negative MCL have been reported. In this study, we collected eight cases initially diagnosed as cyclin D1 protein-positive DLBCL, including four with a CCND1 rearrangement and four without. Immunohistochemically, all four CCND1-rearranged cases had >50% of tumor cells positive for cyclin D1 protein, whereas only one (25%) non-rearranged case had >50% positive tumor cells. Analysis of genome-wide copy number, mutational, and gene expression profiles revealed that CCND1-rearranged cases were similar to MCL, whereas CCND1-non-rearranged cases resembled DLBCL. Despite the SOX11 negativity by immunohistochemistry, CCND1-rearranged cases had a notable trend (P = 0.064) of higher SOX11 mRNA levels compared to non-rearranged cases. Here, we show for the first time that CCND1 rearrangement could be useful for identifying CD5/SOX11 double-negative pleomorphic MCL in cases diagnosed as cyclin D1 protein-positive DLBCL. Cases with >50% cyclin D1 protein-positive tumor cells immunohistochemically and higher SOX11 mRNA levels are more likely to have a CCND1 rearrangement, and fluorescence in situ hybridization can be used to detect the rearrangement.

18.
Lancet Respir Med ; 12(2): 141-152, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38042167

RESUMO

BACKGROUND: In Taiwan, lung cancers occur predominantly in never-smokers, of whom nearly 60% have stage IV disease at diagnosis. We aimed to assess the efficacy of low-dose CT (LDCT) screening among never-smokers, who had other risk factors for lung cancer. METHODS: The Taiwan Lung Cancer Screening in Never-Smoker Trial (TALENT) was a nationwide, multicentre, prospective cohort study done at 17 tertiary medical centres in Taiwan. Eligible individuals had negative chest radiography, were aged 55-75 years, had never smoked or had smoked fewer than 10 pack-years and stopped smoking for more than 15 years (self-report), and had one of the following risk factors: a family history of lung cancer; passive smoke exposure; a history of pulmonary tuberculosis or chronic obstructive pulmonary disorders; a cooking index of 110 or higher; or cooking without using ventilation. Eligible participants underwent LDCT at baseline, then annually for 2 years, and then every 2 years up to 6 years thereafter, with follow-up assessments at each LDCT scan (ie, total follow-up of 8 years). A positive scan was defined as a solid or part-solid nodule larger than 6 mm in mean diameter or a pure ground-glass nodule larger than 5 mm in mean diameter. Lung cancer was diagnosed through invasive procedures, such as image-guided aspiration or biopsy or surgery. Here, we report the results of 1-year follow-up after LDCT screening at baseline. The primary outcome was lung cancer detection rate. The p value for detection rates was estimated by the χ2 test. Univariate and multivariable logistic regression analyses were used to assess the association between lung cancer incidence and each risk factor. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of LDCT screening were also assessed. This study is registered with ClinicalTrials.gov, NCT02611570, and is ongoing. FINDINGS: Between Dec 1, 2015, and July 31, 2019, 12 011 participants (8868 females) were enrolled, of whom 6009 had a family history of lung cancer. Among 12 011 LDCT scans done at baseline, 2094 (17·4%) were positive. Lung cancer was diagnosed in 318 (2·6%) of 12 011 participants (257 [2·1%] participants had invasive lung cancer and 61 [0·5%] had adenocarcinomas in situ). 317 of 318 participants had adenocarcinoma and 246 (77·4%) of 318 had stage I disease. The prevalence of invasive lung cancer was higher among participants with a family history of lung cancer (161 [2·7%] of 6009 participants) than in those without (96 [1·6%] of 6002 participants). In participants with a family history of lung cancer, the detection rate of invasive lung cancer increased significantly with age, whereas the detection rate of adenocarcinoma in situ remained stable. In multivariable analysis, female sex, a family history of lung cancer, and age older than 60 years were associated with an increased risk of lung cancer and invasive lung cancer; passive smoke exposure, cumulative exposure to cooking, cooking without ventilation, and a previous history of chronic lung diseases were not associated with lung cancer, even after stratification by family history of lung cancer. In participants with a family history of lung cancer, the higher the number of first-degree relatives affected, the higher the risk of lung cancer; participants whose mother or sibling had lung cancer were also at an increased risk. A positive LDCT scan had 92·1% sensitivity, 84·6% specificity, a PPV of 14·0%, and a NPV of 99·7% for lung cancer diagnosis. INTERPRETATION: TALENT had a high invasive lung cancer detection rate at 1 year after baseline LDCT scan. Overdiagnosis could have occurred, especially in participants diagnosed with adenocarcinoma in situ. In individuals who do not smoke, our findings suggest that a family history of lung cancer among first-degree relatives significantly increases the risk of lung cancer as well as the rate of invasive lung cancer with increasing age. Further research on risk factors for lung cancer in this population is needed, particularly for those without a family history of lung cancer. FUNDING: Ministry of Health and Welfare of Taiwan.


Assuntos
Adenocarcinoma in Situ , Adenocarcinoma , Neoplasias Pulmonares , Humanos , Feminino , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Fumantes , Estudos Prospectivos , Detecção Precoce de Câncer/métodos , Taiwan/epidemiologia , Tomografia Computadorizada por Raios X/métodos , Programas de Rastreamento
19.
Ann Surg Oncol ; 20(9): 3000-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23584515

RESUMO

BACKGROUND: Two randomized trials have shown that in patients with good response to neoadjuvant chemoradiotherapy (nCRT), a nonoperative approach (additional CRT) had equal survival to scheduled esophagectomy. However, controversy exists because of the high locoregional recurrence (LR) following a nonoperative approach. Endoscopic complete response (e-CR) determined by endoscopic finding is a good criterion for predicting local control after definitive CRT. We evaluated whether e-CR could also be used to select patients for nonoperative treatment after nCRT. METHODS: We retrospectively analyzed esophageal squamous cell carcinoma (SCC) patients with e-CR after nCRT between 1999 and 2006. Patients were divided into two groups by the type of treatment given after e-CR (group A, scheduled esophagectomy; group B, no scheduled surgery and continued CRT). RESULTS: There were 71 and 79 patients in groups A and B, respectively with similar pre/post-nCRT characteristics. Despite similarity in survival and recurrence between groups, the recurrence site differed significantly. LR occurred more frequently in group B, whereas systemic recurrence was the predominant failure pattern in group A (P<.001). With use of multivariate analysis on group B, we determined that pretreatment depth of tumor invasion≥T3 [odds ratio (OR), 11.19; 95% CI, 1.4-89; unfavorable, P=.023] and tumor length≥6 cm (OR, 3.069; 95% CI, 1.17-8.1; unfavorable, P=.023) were predictors for LR. Patients with initial clinical T2 and <6 cm tumor had comparable LR (5%) to the surgery group; these patients were candidates for nonoperative treatment after nCRT. CONCLUSION: In esophageal SCC patients who achieved e-CR after nCRT, pretreatment tumor depth and length were good indicators to select candidates for nonoperative treatment.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/patologia , Quimiorradioterapia , Neoplasias Esofágicas/patologia , Terapia Neoadjuvante , Recidiva Local de Neoplasia/diagnóstico , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/terapia , Cisplatino/administração & dosagem , Neoplasias Esofágicas/mortalidade , Neoplasias Esofágicas/terapia , Feminino , Fluoruracila/administração & dosagem , Seguimentos , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/terapia , Estadiamento de Neoplasias , Prognóstico , Indução de Remissão , Estudos Retrospectivos , Taxa de Sobrevida
20.
AJR Am J Roentgenol ; 201(2): W307-12, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23883245

RESUMO

OBJECTIVE: The Standards for Medical Exposure Quality Assurance in mammography systems were enacted on July 1, 2008, in Taiwan. This study aimed to evaluate the trends in performance of mammography units before and after the regulation started on the basis of annual on-site surveys from 2008 to 2010. MATERIALS AND METHODS: On-site measurements were conducted on 215, 205, and 209 mammography units in 2008, 2009, and 2010, respectively, which accounted for more than 95% of all units in Taiwan. Phantom image quality, average glandular dose (AGD), and half-value layer were evaluated on all systems. Processor conditions, compression conditions, radiation output, and computed radiography exposure indicators were assessed on units participating in mammography screening in 2008 and on all units in the later years. Evaluations of maximum compression force and automatic exposure control reproducibility were added into the protocol from 2009 onward. RESULTS: Mean phantom scores were improved significantly from 2008 to 2009 (11.63 ± 1.30 vs 12.31 ± 0.94, p < 0.05) and remained stable for 2010 (12.35 ± 0.87). Mean AGDs were 1.48 ± 0.47, 1.38 ± 0.41, and 1.37 ± 0.42 mGy over the 3 years, with a significant reduction from 2008 to 2009 (p < 0.05). For film-screen mammography systems, variations of sensitometric curves were greatly reduced in 2009 and 2010 when compared with 2008. Passing rates were increased after the regulation took effect in almost all aspects. CONCLUSION: Results from large-scale on-site surveys showed an overall improvement in performance after quality assurance in mammography was enforced in Taiwan.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/normas , Garantia da Qualidade dos Cuidados de Saúde , Análise de Variância , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Taiwan
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA