Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
2.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
3.
Eur Heart J Case Rep ; 7(12): ytad589, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38425771

RESUMO

Background: Idiopathic inflammatory myopathies (IIMs) are autoimmune diseases that are characterized by muscle injury. These disorders can cause cardiomyopathy and heart failure, myocarditis, and arrhythmias. However, only a few cases of cardiac arrest as a result of IIMs have been previously reported. Case summary: A 46-year-old male presented with an out-of-hospital ventricular fibrillation cardiac arrest. A diagnosis of IIM had been made through a muscle biopsy performed 2 years before presentation. The patient had a positive anti-nuclear antibody but negative myositis-specific antibodies. His initial symptoms of IIM were mild and consisted of myalgias. His only cardiac symptoms were minor palpitations that occurred 3 years prior to the cardiac arrest, with a negative Holter monitor test result at that time. His cardiac catheterization was normal. He was suspected to have myocarditis, and a rheumatologist was consulted, following which the patient was initiated on intravenous immunoglobulin (IVIG). Cardiac magnetic resonance imaging demonstrated evidence of chronic myocarditis and an ejection fraction of 44%. He was initiated on goal-directed medical therapy for heart failure. A VVI implantable cardioverter defibrillator was implanted for secondary prevention. He was discharged and prescribed additional immunosuppression including further IVIG infusions, prednisone taper and rituximab infusions. Discussion: Our case demonstrates that cardiac arrest in IIM is not only plausible, but can be the first major cardiac manifestation of the disease. When a diagnosis of IIM is made, patients require a thorough assessment of cardiac symptomatology and a low threshold for additional cardiac investigations.

4.
CJC Open ; 5(7): 522-529, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37496779

RESUMO

Background: Access to left atrial appendage closure (LAAC) in Canada is limited, due to funding restrictions. This work aimed to assess Canadian clinical practice on patient selection, postprocedural antithrombotic therapy, and safety and/or efficacy with WATCHMAN device implantation. Methods: Seven Canadian centres implanting the WATCHMAN device participated in this prospective multicentre, observational registry. All procedures were done under general anesthesia with transesophageal echocardiography guidance. Patients were prospectively followed for 2years. The long-term stroke rate was compared with the expected rate based on the CHA2DS2-VASc score. Results: A total of 272 patients who underwent LAAC with the WATCHMAN device between December 2013 and August 2019 (mean age: 75.4 years [standard deviation {SD}: 8.75]; male, 63.2%; CHA2DS2-VASc score: 4.35 [SD: 1.64]; HAS-BLED score: 3.55 [SD: 0.94]) were included. Most patients (90.4%) had prior history of bleeding (major, 80.5%; minor, 21.7%). The WATCHMAN device was successfully implanted in 269 patients (98.9%), with a few procedure-related complications, including 5 pericardial effusions requiring drainage (1.8%), and 1 death (0.4%; 22 days post-LAAC from respiratory failure). Post-LAAC antithrombotic therapy included dual antiplatelet therapy in 70.6%, single antiplatelet therapy in 18.4%, and oral anticoagulation in 13.6%. During the follow-up period (mean: 709.7 days [SD: 467.2]), an 81.4% reduction of the ischemic stroke rate occurred, based on the expected rate from the CHA2DS2-VASc score (6.0% expected vs 1.1% observed). Device-related thrombus was detected in 1.8%. Conclusions: The majority of Canadian patients who underwent LAAC had oral anticoagulation contraindication due to prior bleeding, and most were safely treated with antiplatelet therapy post-LAAC, with a low device-related thrombus incidence. Long-term follow-up demonstrated that LAAC achieved a significant reduction in ischemic stroke rate.


Contexte: Au Canada, l'accès à la fermeture de l'appendice auriculaire gauche (FAAG) est limité en raison de restrictions quant au financement de cette intervention. Le présent rapport visait à évaluer les pratiques cliniques canadiennes sur la sélection des patients, le traitement antithrombotique après l'intervention et l'innocuité ou l'efficacité par l'implantation d'un dispositif WATCHMAN. Méthodologie: Sept centres canadiens procédant à l'implantation du dispositif WATCHMAN ont participé à ce registre observationnel, prospectif et multicentrique. Toutes les interventions ont été réalisées sous anesthésie générale avec guidage par échocardiographie transœsophagienne. Les patients ont par la suite été suivis de manière prospective pendant deux ans. Le taux d'AVC à long terme a été comparé au taux attendu, selon le score CHA2DS2-VASc. Résultats: Ont été inclus à l'étude 272 patients ayant subi une FAAG avec implantation d'un dispositif WATCHMAN entre décembre 2013 et août 2019 (âge moyen : 75,4 ans [écart-type {É.-T.} : 8,75]; hommes : 63,2 %; score CHA2DS2-VASc : 4,35 [É.-T. : 1,64]; score HAS-BLED : 3,55 [É.-T. : 0,94]). La plupart des patients (90,4 %) avaient des antécédents de saignements (majeurs : 80,5 %; mineurs : 21,7 %). Le dispositif WATCHMAN a bien été implanté chez 269 patients (98,9 %), avec quelques complications associées à l'intervention, dont cinq effusions péricardiques nécessitant un drainage (1,8 %) et un décès (0,4 %; 22 jours après la FAAG, en raison d'une insuffisance respiratoire). Le traitement antithrombotique après la FAAG comprenait une bithérapie antiplaquettaire dans 70,6 % des cas, une monothérapie antiplaquettaire dans 18,4 % des cas et une anticoagulothérapie orale dans 13,6 % des cas. Pendant la période de suivi (durée moyenne : 709,7 jours [É.-T. : 467,2]), on a noté une réduction de 81,4 % du taux d'AVC ischémique observé par rapport au taux attendu selon le score CHA2DS2-VASc (taux attendu : 6,0 %; taux observé : 1,1 %). Un thrombus associé au dispositif a été détecté dans 1,8 % des cas. Conclusions: La majorité des patients canadiens qui ont subi une FAAG présentaient des contre-indications à l'anticoagulothérapie orale en raison de leurs antécédents de saignements, et la plupart ont été traités de manière sécuritaire par des thérapies antiplaquettaires après la chirurgie, avec un faible taux d'incidence de thrombus associé au dispositif. Le suivi à long terme a montré que la FAAG permet d'obtenir une réduction importante du taux d'AVC ischémique.

5.
J Interv Card Electrophysiol ; 65(2): 481-489, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35739438

RESUMO

BACKGROUND: Transseptal puncture to achieve left atrial access is necessary for many cardiac procedures, including atrial fibrillation ablation. More recently, there has been an increasing need for left atrial access using large caliber sheaths, which increases risk of perforation associated with the initial advancement into the left atrium. We compared the effectiveness of a radiofrequency needle-based transseptal system versus conventional needle for transseptal access. METHODS: This prospective controlled trial randomized 161 patients with symptomatic paroxysmal atrial fibrillation undergoing cryoballoon pulmonary vein isolation to transseptal access with a commercially available transseptal system (radiofrequency needle plus stiff pigtail wire; RF + Pigtail group) versus conventional transseptal access (standard group). The primary outcome was time required for left atrial access. Secondary outcomes included failure of the assigned transseptal system, radiation exposure, and complications. RESULTS: The median transseptal puncture time was significantly shorter using the radiofrequency needle plus stiff pigtail wire transseptal system compared with conventional transseptal (840 ± 323 vs. 956 ± 407 s, P = 0.0489). Compared to conventional transseptal puncture, fewer transseptal attempts were required (1.0 ± 0.5 RF applications vs. 1.3 ± 0.8 mechanical punctures, P = 0.0123) and the fluoroscopy time was significantly shorter (72.0 [IQR 48.0, 129.0] vs. 93.0 [IQR 60.0, 171.0] s, P = 0.0490) with the radiofrequency needle plus stiff pigtail wire transseptal system. Failure to achieve transseptal LA access with the assigned system was rarely observed (1.3% vs. 5.7%, P = 0.2192). There were no procedural complications observed with either system. CONCLUSIONS: The use of a radiofrequency needle plus stiff pigtail wire resulted in shorter time to left atrial access and reduced fluoroscopy time compared to left atrial access using conventional transseptal equipment. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT03199703.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Estudos Prospectivos , Punções , Resultado do Tratamento
6.
Can Respir J ; 22(1): 23-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25379653

RESUMO

BACKGROUND: Obesity rates are increasing worldwide, particularly in North America. The impact of obesity on the outcome of critically ill patients is unclear. METHODS: A prospective observational cohort study of consecutive patients admitted to a tertiary critical care unit in Canada between January 10, 2008 and March 31, 2009 was conducted. Exclusion criteria were age <18 years, admission <24 h, planned cardiac surgery, pregnancy, significant ascites, unclosed surgical abdomen and brain death on admission. Height, weight and abdominal circumference were measured at the time of intensive care unit (ICU) admission. Coprimary end points were ICU mortality and a composite of ICU mortality, reintubation, ventilator-associated pneumonia, line sepsis and ICU readmission. Subjects were stratified as obese or nonobese, using two separate metrics: body mass index (BMI) ≥ 30 kg/m(2) and a novel measurement of 75th percentile for waist-to-height ratio (WHR). RESULTS: Among 449 subjects with a BMI ≥ 18.5 kg/m(2), both BMI and WHR were available for comparative analysis in 348 (77.5%). Neither measure of obesity was associated with the primary end points. BMI ≥ 3 0 kg/m(2) was associated with a lower odds of six-month mortality than the BMI <30 kg/m(2) group (adjusted OR 0.59 [95% CI 0.36 to 0.97]; P=0.04) but longer intubation times (adjusted RR 1.56 [95% CI 1.17 to 2.07]; P=0.003) and longer ICU length of stay (adjusted RR 1.67 [95% CI 1.21 to 2.31]; P=0.002). Conversely, measurement of 75th percentile for WHR was associated only with decreased ICU readmission (OR 0.23 [95% CI 0.07 to 0.79]; P=0.02). CONCLUSIONS: Obesity was not necessarily associated with worse outcomes in critically ill patients.


Assuntos
Estado Terminal/mortalidade , Obesidade/complicações , Adulto , Idoso , Índice de Massa Corporal , Canadá/epidemiologia , Feminino , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Obesidade/mortalidade , Estudos Prospectivos , Relação Cintura-Quadril
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA