1.
Circulation ; 148(3): 241-252, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37459413

RESUMO

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Feminino , Estados Unidos/epidemiologia , Masculino , Brancos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiologia , Prevenção Primária
2.
N Engl J Med ; 384(4): 316-324, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197158

RESUMO

BACKGROUND: In patients with symptomatic paroxysmal atrial fibrillation that has not responded to medication, catheter ablation is more effective than antiarrhythmic drug therapy for maintaining sinus rhythm. However, the safety and efficacy of cryoballoon ablation as initial first-line therapy have not been established. METHODS: We performed a multicenter trial in which patients 18 to 80 years of age who had paroxysmal atrial fibrillation for which they had not previously received rhythm-control therapy were randomly assigned (1:1) to receive treatment with antiarrhythmic drugs (class I or III agents) or pulmonary vein isolation with a cryoballoon. Arrhythmia monitoring included 12-lead electrocardiography conducted at baseline and at 1, 3, 6, and 12 months; patient-activated telephone monitoring conducted weekly and when symptoms were present during months 3 through 12; and 24-hour ambulatory monitoring conducted at 6 and 12 months. The primary efficacy end point was treatment success (defined as freedom from initial failure of the procedure or atrial arrhythmia recurrence after a 90-day blanking period to allow recovery from the procedure or drug dose adjustment, evaluated in a Kaplan-Meier analysis). The primary safety end point was assessed in the ablation group only and was a composite of several procedure-related and cryoballoon system-related serious adverse events. RESULTS: Of the 203 participants who underwent randomization and received treatment, 104 underwent ablation, and 99 initially received drug therapy. In the ablation group, initial success of the procedure was achieved in 97% of patients. The Kaplan-Meier estimate of the percentage of patients with treatment success at 12 months was 74.6% (95% confidence interval [CI], 65.0 to 82.0) in the ablation group and 45.0% (95% CI, 34.6 to 54.7) in the drug-therapy group (P<0.001 by log-rank test). Two primary safety end-point events occurred in the ablation group (Kaplan-Meier estimate of the percentage of patients with an event within 12 months, 1.9%; 95% CI, 0.5 to 7.5). CONCLUSIONS: Cryoballoon ablation as initial therapy was superior to drug therapy for the prevention of atrial arrhythmia recurrence in patients with paroxysmal atrial fibrillation. Serious procedure-related adverse events were uncommon. (Supported by Medtronic; STOP AF First ClinicalTrials.gov number, NCT03118518.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/administração & dosagem , Antiarrítmicos/efeitos adversos , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Prevenção Secundária/métodos , Método Simples-Cego , Inquéritos e Questionários
3.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523591

RESUMO

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Masculino , Feminino , Criocirurgia/métodos , Fibrilação Atrial/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Sistema de Registros , Qualidade de Vida , Idoso , Ablação por Radiofrequência/métodos
4.
J Cardiovasc Electrophysiol ; 34(3): 765-768, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36738138

RESUMO

Guidelines recommend using the CHA2DS2-VASc score to determine anticoagulation decisions in atrial fibrillation (AF) patients, including those who undergo pulmonary vein isolation (PVI), however this may not consistently occur in the real-world setting because of other clinical factors. We sought to evaluate the anticoagulation prescription rates patterns in AF patients 1 year PVI at our institution. Consecutive AF patients undergoing PVI in our prospective registry during 2014-2018 who were alive at 1-year post-PVI were studied. Anticoagulation prescription rates at this time-point were adjudicated, and correlated to CHA2DS2-VASc score, sex, and heart rhythm status at 1 year. Amongst 4596 patients undergoing PVI, mean age was 64.2 ± 10.0 years, 1328 (28.9%) were female, and based on CHA2DS2-VASc score anticoagulation was not indicated, can be considered and indicated in 872 (19.0%), 1183 (25.7%), and 2541 (55.3%) patients, respectively. At 1-year after PVI, 3504 (76.2%) patients were on anticoagulation, and 792 (17.2%) had recurrence of AF. Anticoagulation was continued in over half of AF patients without classic CHA2DS2-VASc indication particularly in those with AF recurrence and women, while they were mildly under-prescribed in those with indication, especially for those without AF recurrence and men. In a large real world cohort of patients after PVI, anticoagulation prescription is not solely depending on the CHA2DS2-VASc score and sex, but also heart rhythm status and other clinical or imaging factors.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Medição de Risco/métodos , Coagulação Sanguínea , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 34(8): 1595-1604, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37453072

RESUMO

INTRODUCTION: Use of sodium glucose cotransporter 2 inhibitors (SGLT2i) was associated with a reduction in atrial fibrillation hospitalizations. Therefore, we aim to evaluate the effects of SGLT2i on atrial tachy-arrhythmias (ATA) in patients with cardiac implantable electronic devices (CIEDs). METHODS: All 13 888 consecutive patients implanted with a CIED in two tertiary medical centers were enrolled. Treatment with SGLT2i was assessed as a time dependent variable. The primary endpoint was the total number of ATA. Secondary endpoints included total number of ventricular tachy-arrhythmias (VTA), ATA and VTA, and death. All events were independently adjudicated blinded to the treatment. Multivariable propensity score modeling was performed. RESULTS: During a total follow-up of 24 442 patient years there were 62 725 ATA and 10 324 VTA events. Use of SGLT2i (N = 696) was independently associated with a significant 22% reduction in the risk of ATA (hazard ratio [HR] = 0.78 [95% confidence interval {CI} = 0.70-0.87]; p < .001); 22% reduction in the risk of ATA/VTA (HR = 0.78 [95% CI = 0.71-0.85]; p < .001); and with a 35% reduction in the risk of all-cause mortality (HR = 0.65 [95% CI = 0.45-0.92]; p = .015), but was not significantly associated with VTA risk (HR = 0.92 [95% CI = 0.80-1.06]; p = .26). SGLT2i were associated with a lower ATA burden in heart failure (HF) patients but not among diabetes patients (HF: HR = 0.68, 95% CI = 0.58-0.80, p < .001 vs. Diabetes: HR = 0.95, 95% CI = 0.86-1.05, p = .29; p < .001 for interaction between SGLT2i indication and ATA burden). CONCLUSION: Our real world findings suggest that in CIED HF patients, those with SGLT2i had a pronounced reduction in ATA burden and all-cause mortality when compared with those not on SGLT2i.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Fibrilação Atrial/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Glucose
6.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448428

RESUMO

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Alta do Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Satisfação do Paciente , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36259719

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Medidas de Resultados Relatados pelo Paciente
8.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493505

RESUMO

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Sobrepeso/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Obesidade/complicações , Obesidade/diagnóstico , Resultado do Tratamento
9.
Am Heart J ; 251: 35-42, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35526570

RESUMO

BACKGROUND: For patients with symptomatic atrial fibrillation (AF), physicians typically offer AF ablation for symptom relief; however, patients often anticipate/expect a life free from anticoagulation. This belief puts patients at increased risk of stroke due to the potential for asymptomatic AF postablation if anticoagulation is ceased contrary to clinical guidelines. Although the WATCHMAN device has been FDA-approved to decrease the risk of thromboembolism from the left atrial appendage (LAA) in patients with an appropriate rationale to avoid oral anticoagulation, it has not been well-studied following AF ablation. Additionally, there are limited data comparing the WATCHMAN device to direct oral anticoagulants. The OPTION study will investigate whether LAA closure with the WATCHMAN FLX device is a reasonable alternative to oral anticoagulation following percutaneous catheter ablation for nonvalvular AF. TRIAL DESIGN: OPTION is a multinational, multicenter, prospective randomized clinical trial. Patients with a CHA2DS2-VASc of ≥2 in men or ≥3 in women and who underwent a AF catheter ablation procedure between 90 and 180 days prior to randomization (sequential) or are planning to have catheter ablation within 10 days of randomization (concomitant) will be randomized in a 1:1 allocation of WATCHMAN FLX vs control. Control patients will start or continue market-approved oral anticoagulation for the duration of the trial. A total of 1600 patients were randomized from 130 global investigational sites. Follow-up for both device and control patients will occur at 3, 12, 24, and 36 months. The primary effectiveness noninferiority endpoint is stroke (ischemic or hemorrhagic), all-cause death, or systemic embolism at 36 months. The primary safety superiority endpoint is nonprocedural bleeding through 36 months (International Society on Thrombosis and Haemostasis [ISTH] major bleeding or clinically relevant nonmajor bleeding). The secondary noninferiority endpoint is ISTH major bleeding through 36 months (including procedural bleeding). CONCLUSIONS: This trial will assess the safety and efficacy of WATCHMAN FLX in a postablation contemporary clinical AF patient population at risk of stroke.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35689504

RESUMO

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(2): 197-208, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34855270

RESUMO

BACKGROUND: Antiarrhythmic drugs (AADs) and catheter ablation are first line treatments of paroxysmal atrial fibrillation (PAF), however, there exists a paucity of data regarding the potential benefit of different catheter ablation technologies versus AADs as an early rhythm strategy. OBJECTIVE: To assess the safety and efficacy of cryoablation versus radiofrequency ablation (RFA) versus AADs as a first line therapy of PAF. METHODS: MEDLINE, Embase, Scopus and CENTRAL were searched to retrieve randomized clinical trials (RCTs) comparing cryoablation, RFA or AADs to one another as first line therapies for atrial fibrillation (AF). The primary outcome was overall freedom from arrhythmia recurrence (AF, atrial flutter [AFL], atrial tachycardia). Secondary outcomes included freedom from symptomatic arrhythmia recurrence, hospitalization, and serious adverse events. A random-effects Bayesian network meta-analysis was used to calculate odds ratios (OR) and 95% credible intervals (CrI). RESULTS: Six RCTs (N = 1212) met the inclusion criteria (605 AADs, 365 Cryoablation, and 245 RFA). Compared with AADs, overall recurrence was reduced with RFA (OR: 0.31; 95% CrI: 0.10-0.71) and cryoablation (OR: 0.39; 95% CrI: 0.16-1.00). Comparing ablation (cryoablation and RFA) with AADs in respect to freedom from symptomatic AF recurrence, neither cryoablation (OR: 0.35; 95% CrI: 0.06-1.96) nor RFA (OR: 0.34; 95% CrI: 0.07-1.27) resulted in statistically significant reductions individually compared to AADs, though pooled ablation with both technologies showed lower odds of arrhythmia recurrence (OR: 0.35; 95% CrI: 0.13-0.79). In terms of serious adverse events rates, neither cryoablation (OR: 0.77; 95% CrI: 0.44-1.39) nor RFA (OR: 1.45; 95% CrI: 0.67-3.23) were significantly different to AADs. RFA resulted in a statistically significant reduction in hospitalizations compared to AAD (OR: 0.08; 95% CrI: 0.01-0.99), whereas cryoablation did not (OR: 0.77; 95% CrI: 0.44-1.39). The surface under the cumulative ranking curve showed RFA to be the most effective treatment at reducing overall rates of recurrence, symptomatic recurrence and hospitalizations; whereas cryoablation was most likely to reduce serious adverse events. CONCLUSION: Cryoablation and RFA are both effective and safe first line therapies for AF compared to AADs, with RFA being the most effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Ablação por Radiofrequência , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Metanálise em Rede , Recidiva , Resultado do Tratamento
12.
Europace ; 24(Suppl 2): ii14-ii21, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35661868

RESUMO

Atrial fibrillation (AF) is a commonly encountered chronic and progressive heart rhythm disorder, characterized by exacerbations and remissions. Contemporary clinical practice guidelines recommend a trial of antiarrhythmic drugs (AADs) as the initial therapy for sinus rhythm maintenance; however, these medications have modest efficacy and are associated with significant adverse effects. Recently, several trials have demonstrated that an initial treatment strategy of cryoballoon catheter ablation significantly improves arrhythmia outcomes (e.g. freedom atrial tachyarrhythmia and reduction in arrhythmia burden), produces clinically meaningful improvements in patient-reported outcomes (e.g. symptoms and quality of life), and significantly reduces subsequent healthcare resource utilization (e.g. hospitalization), without increasing the risk of serious or any adverse events. These findings are relevant to patients, providers, and healthcare systems, helping inform the decision regarding the initial choice of rhythm-control therapy in patients with treatment-naïve AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Qualidade de Vida , Resultado do Tratamento
13.
J Electrocardiol ; 75: 1-9, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36272350

RESUMO

BACKGROUND: The electrocardiography (ECG) has short-term prognostic value in coronavirus disease 2019 (COVID-19), yet its ability to predict long-term mortality is unknown. This study aimed to elucidate the predictive role of initial ECG on long-term all-cause mortality in patients diagnosed with COVID-19. METHODS: In this prospective cohort study, adults with COVID-19 who underwent ECG testing within a 17-hospital health system in Northeast Ohio and Florida between 03/2020-06/2020 were identified. An expert ECG reader analyzed all studies blinded to patient status. The associations of ECG characteristics with long-term all-cause mortality and intensive care unit (ICU) admission were assessed using Cox proportional hazards regression model and multivariable logistic regression models, respectively. Status of long-term mortality was adjudicated on 01/07/2022. RESULTS: Of 837 patients (median age 65 years, 51% female, 44% Black), 683 (81.6%) were hospitalized, 281 (33.6%) required ICU admission, 67 (8.0%) died in-hospital, and 206 (24.6%) died at final follow-up after a median (IQR) of 21 (9-103) days after ECG. Overall, 179 (20.7%) patients presented with sinus tachycardia, 12 (1.4%) with atrial flutter, and 45 (5.4%) with atrial fibrillation (AF). After multivariable adjustment, sinus tachycardia (E-value for HR=3.09, lower CI=2.2) and AF (E-value for HR=3.13, lower CI=2.03) each independently predicted all-cause mortality. At final follow-up, patients with AF had 64.5% probability of death compared with 20.5% for those with normal sinus rhythm (P<.0001). CONCLUSIONS: Sinus tachycardia and AF on initial ECG strongly predict long-term all-cause mortality in COVID-19. The ECG can serve as a powerful long-term prognostic tool in COVID-19.


Assuntos
Fibrilação Atrial , COVID-19 , Adulto , Humanos , Feminino , Idoso , Masculino , Eletrocardiografia , Prognóstico , Estudos Prospectivos , Taquicardia Sinusal , Fibrilação Atrial/diagnóstico
14.
J Cardiovasc Electrophysiol ; 32(7): 1909-1917, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955116

RESUMO

BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.


Assuntos
Ablação por Cateter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia
15.
Europace ; 23(8): 1211-1218, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-33585883

RESUMO

AIMS: CHA2DS2-VASc score is widely utilized for risk stratification and guiding anticoagulation in patients with atrial fibrillation (AF). Cardiac computed tomography (CCT) routinely performed for pulmonary vein isolation (PVI) can also identify coronary artery calcifications (CAC). We evaluated the frequency and outcomes of incorporating CAC into the CHA2DS2-VASc score in AF patients undergoing PVI. METHODS AND RESULTS: Consecutive patients in a prospective PVI registry during 2014-18 having CCT within 1 year of PVI were studied. Reclassification of CHA2DS2-VASc score and associations between CAC as a binary variable detected on CCT with clinical characteristics, stroke as primary endpoint, death, myocardial infarction, and major adverse cardiovascular events (MACE) were analysed. Amongst 3604 AF patients, 2238 (62.1%) had CAC detected on CCT and was associated with most traditional cardiovascular risk factors. Coronary artery calcification was independently associated with all pre-specified endpoints adjusting for clinical parameters in multivariable analysis. Adjusting for CHA2DS2-VASc score, CAC was associated with stroke (hazards ratio 3.64, 95% confidence interval 1.25-10.6, P = 0.018), death (2.26, 1.29-3.98, P = 0.006), and MACE (2.08, 1.36-3.16, P = 0.001) during 2.8 ± 1.6-year follow-up. Incorporating CAC as a vascular disease parameter of CHA2DS2-VASc score, anticoagulation decision-making would be revised in 723 (20.1%) patients, including an additional 488 (13.5%) patients where anticoagulation would be now indicated. CONCLUSION: Coronary artery calcification is prevalent in AF patients undergoing PVI and independently associated stroke, death and MACE even when adjusted for traditional CHA2DS2-VASc score. Adding CAC as vascular component to the CHA2DS2-VASc score requires further research as it potentially modified the anticoagulation management in 20% of our AF cohort.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tomografia Computadorizada por Raios X
16.
Europace ; 23(8): 1237-1243, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-33729470

RESUMO

AIMS: Cryoballoon pulmonary vein isolation (PVI) is a safe and effective treatment for atrial fibrillation (AF). Current limitations include incomplete vein occlusion due to balloon rigidity and inconsistent electrogram recording, which impairs identification of isolation. We aimed to evaluate the acute safety and performance of a novel cryoballoon system. METHODS AND RESULTS: The system includes a steerable sheath, mapping catheter, and a balloon that maintains uniform inflation pressure and size following initiation of ablation. Protocol-directed cryoablation was delivered for 180 s for isolation documented in ≤60 s, otherwise freeze duration was 240 s. Primary endpoints were acute safety and vein isolation. Pulmonary vein isolation was confirmed at ≥30 min post-isolation. Data were compared across vein locations. Thirty patients with paroxysmal AF were enrolled at two centres and underwent PVI. Pulmonary vein isolation was achieved with cryoablation only in 100% of veins (120/120). Nadir temperature was -53.1 ± 5.3°C. The number of applications to achieve PVI was 1.4 ± 0.4 per vein. Of the 120 veins, 89 were isolated with a single cryothermal application (10/30 patients required only 4 total cryoablations). There were no procedural- or device-related serious adverse events at 30 days post-procedure. A subset (24/30) of patients was followed for 1-year and 71% (17/24) remained free of atrial arrhythmias. Six patients with arrhythmia recurrence were remapped and three had durable PVI for all four veins. CONCLUSION: In this first human experience, the novel cryoballoon platform was safe, efficacious, and demonstrated a high proportion of successful single ablation isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
17.
Europace ; 23(7): 1063-1071, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33463688

RESUMO

AIMS: Heart rate recovery (HRR), the decrease in heart rate occurring immediately after exercise, is caused by the increase in vagal activity and sympathetic withdrawal occurring after exercise and is a powerful predictor of cardiovascular events and mortality. The extent to which it impacts outcomes of atrial fibrillation (AF) ablation has not previously been studied. The aim of this study is to investigate the association between attenuated HRR and outcomes following AF ablation. METHODS AND RESULTS: We studied 475 patients who underwent EST within 12 months of AF ablation. Patients were categorized into normal (>12 b.p.m.) and attenuated (≤12 b.p.m.) HRR groups. Our main outcomes of interest included arrhythmia recurrence and all-cause mortality. During a mean follow-up of 33 months, 43% of our study population experienced arrhythmia recurrence, 74% of those with an attenuated HRR, and 30% of those with a normal HRR (P < 0.0001). Death occurred in 9% of patients in the attenuated HRR group compared to 4% in the normal HRR cohort (P = 0.001). On multivariable models adjusting for cardiorespiratory fitness (CRF), medication use, left atrial size, ejection fraction, and renal function, attenuated HRR was predictive of increased arrhythmia recurrence (hazard ratio 2.54, 95% confidence interval 1.86-3.47, P < 0.0001). CONCLUSION: Heart rate recovery provides additional valuable prognostic information beyond CRF. An impaired HRR is associated with significantly higher rates of arrhythmia recurrence and death following AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Frequência Cardíaca , Humanos , Recidiva , Fatores de Risco , Resultado do Tratamento
18.
Ultrason Imaging ; 43(6): 299-307, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34510970

RESUMO

Radiofrequency ablation (RFA) is a common treatment of atrial fibrillation. However, current treatment is associated with a greater than 20% recurrence rate, in part due to inadequate monitoring of tissue viability during ablation. Spectral parameters, in particular cyclic variation of integrated backscatter (CVIB), have shown promise as early indicators of myocardial recovery from ischemia. Our aim was to demonstrate the use of spectral parameters to differentiate atrial myocardium before and after radiofrequency ablation. An AcuNav 10 F catheter was used to collect radiofrequency signals from the posterior wall of the left atrium of patients before and immediately after RFA for AF. The normalized power spectrum was obtained and three spectral parameters (integrated backscatter [IB], slope, and intercept) were extracted across two continuous heart cycles. Parameters were gated for ventricular end-diastole and compared before and after ablation. Additionally, the cyclic variation of each of these three parameters was generated as an average of the variation across the two recorded heart cycles. Data from 14 patients before and after ablation demonstrated a significant difference in the magnitude of the cyclic variation of integrated backscatter (9.0 vs. 6.0 dB, p < .001) and cyclic variation of the intercept (14.0 vs. 11.5 dB, p = .04). No significant difference was noted in the magnitude of the cyclic variation of the slope. Among spectral parameters gated for end-diastole, significant differences were noted in the slope (-4.39 vs. -3.73 dB/MHz, p = .002) and intercept (16.8 vs. 11.9 dB, p = .002). No significant difference was noted in the integrated backscatter. Spectral parameters are able to differentiate atrial myocardium before and immediately following ablation and may be useful in monitoring atrial ablations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Miocárdio
19.
J Cardiovasc Electrophysiol ; 31(8): 1979-1986, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32510749

RESUMO

BACKGROUND: Morbid obesity is associated with prohibitively high arrhythmia recurrence rates following atrial fibrillation (AF) ablation. DESIGN: This was a single-center study comprising 239 patients with morbid obesity and symptomatic paroxysmal or persistent AF undergoing AF ablation compared to 239 patients with a body mass index less than 30 kg/m2 matched based on age, sex, ejection fraction, AF type, presence and type of heart failure, and left atrial volume index. METHODS: Our primary outcome of interest was arrhythmia recurrence. RESULTS: During a mean follow-up of 29 months, arrhythmia recurrence was observed in 65% of the morbidly obese cohort compared to 27% of the control group (P < .0001). Among those with morbid obesity, sleep apnea screening, and treatment (91% vs 40%; P < .0001), blood pressure control (62% vs 53%; P = .001), glycemic control (85% vs 56%; P = .004), and weight loss more than equal to 5% (33% vs 57% in those who lost less than 5% and 83% in those who gained weight, P < .0001) were associated with lower arrhythmia recurrence. Recurrent arrhythmia was observed in one (4%) patient who accomplished all four goals, compared to 36% who achieved 3 of 4, 85% who modified 2 of 4%, and 97% of those who modified zero or one risk-factor. Risk-factor modification (RFM) was also associated with substantial reductions in the need for repeat ablation or direct-current cardioversion and arrhythmia-related hospitalization (P < .0001). CONCLUSION: RFM through pragmatic noninvasive means such as blood pressure and glycemic control, sleep apnea screening and treatment, and weight loss is associated with substantially lower rates of recurrent arrhythmia among morbidly obese patients undergoing AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Obesidade Mórbida , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Humanos , Obesidade Mórbida/complicações , Obesidade Mórbida/diagnóstico , Obesidade Mórbida/cirurgia , Recidiva , Fatores de Risco , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 31(5): 1182-1186, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108406

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is indicated in patients with medically refractory heart failure and wide QRS duration. While much is known about predictors of left ventricular (LV) remodeling after CRT implantation and short-term mortality, limited data exist on long-term outcomes after CRT placement. METHODS: We retrospectively reviewed all patients undergoing CRT implantation at our center between 2003 and 2008 and examined mortality using institutional electronic records, social security death index, and online obituary search. We included only patients with preimplant echoes with LV ejection fraction (LVEF) 35% or below. Variable selection was performed using stepwise regression and models were compared using goodness-of-fit criteria. A final model was validated with the bootstrap regression method. RESULTS: Out of the 877 CRT patients undergoing implantation during this time, 287 (32.7%) survived longer than 10 years. Significant (P < .05) predictors of survival in our multivariate model were age, left ventricular diastolic diameter, sex, presence of nonischemic vs ischemic cardiomyopathy, QRS duration, atrial fibrillation, BNP levels, and creatinine levels at the time of CRT implantation. A model using the odds ratios from these variables had a receiver operating curve with an area under the curve score of 0.816 (standard error, 0.019) at predicting survival or freedom from LVAD or heart transplant for longer than 10 years after CRT implantation. The specificity for factors 3 or above and 5 or above was 68% and 77%, respectively. CONCLUSION: A large proportion of patients are still alive 10 years after CRT implantation. Variables at the time of CRT implant can help provide prognostic information to patients and electrophysiologists to determine the long-term benefit and survival of patients after CRT implantation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sobreviventes , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA