Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 100(3): 404-412, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35723247

RESUMO

OBJECTIVES: Evaluate transcatheter heart valve (THV) geometry according to left ventricular outflow tract (LVOT) calcium degree and its impact on hemodynamics and outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a contemporary self-expanding THV. BACKGROUND: LVOT calcium remains challenging for contemporary THVs. LVOT calcium location and degree may affect THV deployment and impact flow patterns and shear stress, accelerating THV degeneration. METHODS: EPROMPT (CoreValve Evolut Pro Prospective Registry; NCT03423459) is a prospective, investigator-initiated, multicenter registry of patients undergoing TAVR using CoreValve Evolut PRO/PRO + THVs. A total of 107 patients were enrolled in EPROMPT's computed tomography (CT) cohort between January 2018 and October 2021. These patients underwent follow-up CT scan 30 days post-TAVR. We analyzed THV geometry and its interaction with the aortic root following deployment using 30-day post-TAVR CT in patients with none/mild versus moderate/severe LVOT calcium. RESULTS: Thirty-day THV inflows were less eccentric in the short axis in patients with none/mild versus moderate/severe LVOT calcium (1.16 ± 0.09 vs. 1.21 ± 0.12; p = 0.007). THV became more circular and was similar between both cohorts at the THV waist (1.08 ± 0.06 vs. 1.09 ± 0.11; p = 0.551), leaflet tips (1.03 ± 0.04 vs. 1.05 ± 0.09; p = 0.299), and THV outflow (1.04 ± 2.2 vs. 1.03 ± 2.7; p = 0.143). Thirty-day > mild paravalvular leak was low in both cohorts (1.5% vs. 2.4%; p = 0.724); mean gradients were similar (7.7 ± 3.6 vs. 7.7 ± 3.4 mmHg; p = 0.955). CONCLUSIONS: Despite inflow deformities observed in patients with moderate/severe LVOT calcium, Evolut PRO/PRO + conforms to elliptical aortic annuli, maintaining circularity and proper function at the leaflets and outflow, even in patients with moderate/severe LVOT calcium.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Cálcio , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34505737

RESUMO

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Am Heart J ; 237: 25-33, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33713618

RESUMO

BACKGROUND: Previous studies from the Low Risk TAVR (LRT) trial demonstrated that transcatheter aortic valve replacement (TAVR) is safe and feasible in low-risk patients, with excellent 30-day and 1-year outcomes. The objective of this study was to report clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration (SVD) 2 years after TAVR. METHODS: The LRT trial was the first Food and Drug Administration-approved Investigational Device Exemption trial in the United States to evaluate the safety and feasibility of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis (AS). Valve hemodynamics and SVD by echo were recorded 30 days, 1 year, and 2 years post-TAVR. RESULTS: The LRT trial enrolled 200 low-risk patients to receive TAVR. Their mean age was 73.6 years and 61.5% were men. At 2-year follow-up, the mortality rate was 4.2%; the cardiovascular death rate was 1.6%. The disabling stroke rate was 1.1%, permanent pacemaker implantation rate was 8.6%, and 4 patients (2.2%) presented with endocarditis (2 between years 1 and 2). Of the 14% of TAVR subjects who had evidence of HALT at 30 days, there was no impact on valve hemodynamics, endocarditis or stroke at 2 years. CONCLUSIONS: TAVR for low-risk patients with symptomatic severe tricuspid AS is safe at 2 years. The presence of HALT at 30 days did not impact the early hemodynamic improvements nor the durability of the valve structure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(3): 580-585, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34051039

RESUMO

OBJECTIVE: Compare two large-bore vascular closure devices (VCDs), collagen-plug-based MANTA and suture-based dual Perclose ProGlide (PP), in patients undergoing contemporary transfemoral transcatheter aortic valve replacement (TAVR). BACKGROUND: The SAFE MANTA IDE clinical trial demonstrated that the collagen-plug-based MANTA VCDs were safe and effective in closing large-bore arteriotomies. However, data comparing this collagen-plug-based VCD to the suture-based VCD in contemporary practice are sparse. METHODS: This was a retrospective observational study in which we screened transfemoral (TF) TAVR patients at our institution from 2017 to 2020. Included were those whose large-bore TF access was closed using either MANTA or PP with and without Angio-Seal. Our primary outcome was VCD success. Additional in-hospital outcomes included major and minor vascular complications, post-TAVR length of stay, and mortality. RESULTS: We screened 696 patients who underwent TAVR. Using propensity scores, we matched 124 patients who received MANTA with 124 patients who received PP. Patients had a mean age of 77.2 years, 69.0% were men, and their mean Society of Thoracic Surgeons score was 3.4%. VCD success was equivalent between VCDs (95.2% vs. 95.2%; p = 1.000). Patients had similar rates of mortality (0% vs. 0.8%; p = .316), and no patients had major vascular complications. CONCLUSIONS: In contemporary TAVR, the collagen-plug-based MANTA VCD appears to be as safe and effective as the suture-based dual PP VCD, with no differences in VCD success, vascular complications, or mortality. Therefore, selection of VCD for TAVR should be left to operator discretion, taking into account anatomical considerations.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 90(4): 673-679, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28296039

RESUMO

BACKGROUND: Residual aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is associated with adverse outcome. We sought to evaluate the efficacy and safety of second CoreValve (CV) implantation to treat residual AR following the initial CV deployment. METHODS AND RESULTS: TAVR patients treated with a second CV due to moderate and above residual AR were compared to single device implantation. Valvular function parameters were compared at baseline, post procedure, and 30 days. Among 172 CV TAVR patients, 11 required a second device (6%) due to significant residual AR. The main differences between the groups were higher rates of low ejection fraction in patients with 2 CV implanted and higher annular diameter (27 [29-25] vs. 25 [26-24] mm, P = 0.03), requiring a larger device. Although two patients in the two CV group had high initial implantation, low implantation was similar between the groups. A second CV achieved adequate reduction in residual AR in six patients (55%), while an additional four patients had moderate residual AR. Only one remained with moderate to severe AR after 30 days follow-up. There were no cases of peri-procedural stroke or mortality. CONCLUSIONS: Second implantation of self-expanding valve can successfully reduce residual significant AR following initial CV implantation and should be considered as therapeutic option for this population. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Cardiovasc Magn Reson ; 18(1): 45, 2016 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-27430331

RESUMO

BACKGROUND: Scar burden by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is associated with functional recovery after coronary artery bypass surgery (CABG). There is limited data on long-term mortality after CABG based on left ventricular (LV) scar burden. METHODS: Patients who underwent LGE CMR between January 2003 and February 2010 within 1 month prior to CABG were included. A standard 16 segment model was used for scar quantification. A score of 1 for no scar, 2 for ≤ 50 % and 3 for > 50 % transmurality was assigned for each segment. LV scar score (LVSS) defined as the sum of segment scores divided by 16. All-cause mortality was ascertained by social security death index. RESULTS: One hundred ninety-six patients met the inclusion criteria. 185 CMR studies were available. History of prior MI was present in 64 % and prior CABG in 5.4 % of patients. Scar was present in 72 % of patients and median LVEF was 38 %. Over a median follow up of 8.3 years, there were 64 deaths (34.6 %). There was no statistically significant difference in mortality between Scar and No-scar groups (37 % versus 29 %). In the group with scar, a lower scar burden (defined either < 4 segments with scar or based on LVSS) was independently associated with increased survival. CONCLUSION: In patients undergoing surgical revascularization, scar burden is negatively associated with survival in patients with scar. However, there is no difference in survival based on presence or absence of scar alone. CMR prior to CABG adds additional prognostic information.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Idoso , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Cicatriz/mortalidade , Cicatriz/fisiopatologia , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Bases de Dados Factuais , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
Eur Radiol ; 25(1): 58-64, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25182629

RESUMO

OBJECTIVES: The purpose of this study was to investigate the effects of knowledge-based iterative model reconstruction (IMR) on image quality in cardiac CT performed for the planning of redo cardiac surgery by comparing IMR images with images reconstructed with filtered back-projection (FBP) and hybrid iterative reconstruction (HIR). METHODS: We studied 31 patients (23 men, 8 women; mean age 65.1 ± 16.5 years) referred for redo cardiac surgery who underwent cardiac CT. Paired image sets were created using three types of reconstruction: FBP, HIR, and IMR. Quantitative parameters including CT attenuation, image noise, and contrast-to-noise ratio (CNR) of each cardiovascular structure were calculated. The visual image quality--graininess, streak artefact, margin sharpness of each cardiovascular structure, and overall image quality--was scored on a five-point scale. RESULTS: The mean image noise of FBP, HIR, and IMR images was 58.3 ± 26.7, 36.0 ± 12.5, and 14.2 ± 5.5 HU, respectively; there were significant differences in all comparison combinations among the three methods. The CNR of IMR images was better than that of FBP and HIR images in all evaluated structures. The visual scores were significantly higher for IMR than for the other images in all evaluated parameters. CONCLUSIONS: IMR can provide significantly improved qualitative and quantitative image quality at in cardiac CT for planning of reoperative cardiac surgery. KEY POINTS: • Cardiac CT before redo surgery may mitigate increased risk • Iterative model reconstruction is the next generation in iterative reconstruction • Iterative model reconstruction improves the image quality in cardiac CT.


Assuntos
Algoritmos , Procedimentos Cirúrgicos Cardíacos , Angiografia Coronária/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Período Pré-Operatório , Doses de Radiação , Estudos Retrospectivos
11.
Artigo em Inglês | MEDLINE | ID: mdl-38797580

RESUMO

BACKGROUND: Outflow graft obstruction (OGO) is an uncommon yet life-threatening complication in patients with left ventricular assist devices (LVADs). In this retrospective, single-center case series, we identify the baseline demographics and presenting features of patients who develop LVAD OGO and the procedural details and outcomes surrounding percutaneous endovascular intervention (PEI). METHODS: We conducted a retrospective review of patients with LVADs at our institution between January 2010 and February 2023 who developed OGO and were treated with PEI. Details of the PEI including procedure time, fluoroscopy time, contrast use, stent size, number of stents, change in gradient, and change in flow after intervention were collected. RESULTS: A total of 12 patients who had 14 cases of OGO were identified from January 2010 to February 2023. The average age at presentation was 64.78 years. Nine of the 14 cases occurred in male patients. Eleven of the 14 cases occurred with Heartware devices (2 recurrences), 2 in Heartmate 2 and 1 in Heartmate 3. Notable procedural details include a mean procedure time of 90.86 min and mean contrast use of 162.5 mL. The initial gradient across the OGO was reduced by an average of 72 %, to a mean post-PEI of 11.57 mmHg. The average number of stents to achieve this gradient was around 2.08, with the most common stent diameter being 10 mm. Thirty-day mortality after PEI was 7 % (1/14) in this high-risk patient population. CONCLUSION: In our single-center experience, PEI can be a safe and effective treatment for LVAD OGO.

12.
Cardiovasc Revasc Med ; 59: 76-80, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37689575

RESUMO

BACKGROUND: Computed tomography with fractional flow reserve (CT-FFR) is increasingly common in assessing coronary artery disease. CASE PRESENTATION: We report five cases of discrepancies that led to changes in treatment. CONCLUSIONS: This report highlights discordant findings between modalities, which should be considered during the diagnostic assessment of chest pain.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Sensibilidade e Especificidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
13.
medRxiv ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38410488

RESUMO

Background: Regadenoson is used to induce hyperemia in cardiac imaging, facilitating diagnosis of ischemia and assessment of coronary flow reserve (CFR). While the regadenoson package insert recommends administration of radionuclide tracer 10-20 seconds after injection, peak hyperemia has been observed at approximately 100 seconds after injection in healthy volunteers undergoing cardiovascular magnetic resonance imaging (CMR). It is unclear when peak hyperemia occurs in a patient population. Objectives: The goal of this study was to determine time to peak hyperemia after regadenoson injection in healthy volunteers and patients, and whether the recommended image timing in the package insert underestimates CFR. Methods: Healthy volunteers (n=15) and patients (n=25) underwent stress CMR, including phase-contrast imaging of the coronary sinus at rest and multiple timepoints after 0.4 mg regadenoson injection. Coronary sinus flow (ml/min) was divided by resting values to yield CFR. Smoothed, time-resolved curves for CFR were generated with pointwise 95% confidence intervals. Results: CFR between 60 and 120 seconds was significantly higher than CFR at 30 seconds after regadenoson injection (p < 0.05) as shown by non-overlapping 95% confidence intervals for both healthy volunteers (30 s, [2.8, 3.4]; 60 s, [3.8, 4.4]; 90 s, [4.1, 4.7]; 120 s, [3.6, 4.3]) and patients (30 s, [2.1, 2.5]; 60 s, [2.6, 3.1]; 90 s, [2.7, 3.2]; 120 s, [2.5, 3.1]). Conclusion: Imaging at 90 seconds following regadenoson injection is the optimal approach to capture peak hyperemia. Imaging at 30 seconds, which is more aligned with the package insert recommendation, would yield an underestimate of CFR and confound assessment of microvascular dysfunction.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38849237

RESUMO

In current clinical practice, qualitative or semi-quantitative measures are primarily used to report coronary artery disease on cardiac CT. With advancements in cardiac CT technology and automated post-processing tools, quantitative measures of coronary disease severity have become more broadly available. Quantitative coronary CT angiography has great potential value for clinical management of patients, but also for research. This document aims to provide definitions and standards for the performance and reporting of quantitative measures of coronary artery disease by cardiac CT.

15.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
16.
Echocardiography ; 30(7): E195-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23557255

RESUMO

Cardiac fibromas represent the second most common benign cardiac mass seen in the pediatric population, but they are rarely seen in adults. Given their large size and unpredictable location within the heart, patients may present with varying symptomatology, and in many cases, the initial presentation is sudden death. Both echocardiography and magnetic resonance imaging are critical to the early diagnosis and prompt treatment of these potentially dangerous primary tumors. We report a 29-year-old woman presenting with syncope and ventricular tachycardia. She was found to have a 5.0 cm inferoapical left ventricular fibroma, which was successfully resected.


Assuntos
Fibroma/complicações , Fibroma/diagnóstico por imagem , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Síncope/etiologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Adulto , Diagnóstico Diferencial , Ecocardiografia Tridimensional/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Síncope/diagnóstico
17.
Am J Cardiol ; 206: 108-115, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37690148

RESUMO

Subclinical leaflet thrombosis occurs with transcatheter heart valves (THVs) and could be associated with structural valve deterioration. The current guidelines recommend the use of antiplatelet agents after transcatheter aortic valve replacement (TAVR) but not the routine use of oral anticoagulation. Our study examines the effects of short-term warfarin therapy on THV hemodynamics at 24 months after TAVR in low-risk patients. Low-risk patients who underwent TAVR were randomly allocated 1:1 to receive low-dose aspirin (n = 50) or low-dose aspirin plus warfarin (n = 44). After 30 days of treatment, ongoing medication regimens, including anticoagulation, were at the physicians' discretion. Follow-up after a period of 24 months was available for clinical and echocardiographic outcomes. At the 24-month mark, follow-up echocardiography of the randomly allocated patients revealed just 1 additional case of new structural valve deterioration in the aspirin group (compared with the occurrence within 30 days), based on the Valve Academic Research Consortium 3 definitions. There were also no differences in mean pressure gradients (11.5 ± 0.5 mm Hg vs 11.05 ± 4.0 mm Hg, p = 0.6) or peak velocity (2.2 ± 0.5 m/s vs 2.1 ± 0.4 m/s, p = 0.7) between the groups. A composite end point (mortality, stroke, and myocardial infarction) did not show any difference between the groups at long-term follow-up (p = 0.07). In conclusion, in low-risk patients who underwent TAVR, short-term anticoagulation with warfarin did not impact clinical outcomes or THV hemodynamics by echocardiography at 24 months.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Varfarina/uso terapêutico , Aspirina/uso terapêutico , Valva Aórtica/cirurgia , Seguimentos , Anticoagulantes/uso terapêutico , Estenose da Valva Aórtica/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento
18.
J Am Coll Cardiol ; 82(18): 1792-1803, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37879784

RESUMO

The United States has the highest maternal mortality in the developed world with cardiovascular disease as the leading cause of pregnancy-related deaths. In response to this, the emerging subspecialty of cardio-obstetrics has been growing over the past decade. Cardiologists with training and expertise in caring for patients with cardiovascular disease in pregnancy are essential to provide effective, comprehensive, multidisciplinary, and high-quality care for this vulnerable population. This document provides a blueprint on incorporation of cardio-obstetrics training into cardiovascular disease fellowship programs to improve knowledge, skill, and expertise among cardiologists caring for these patients, with the goal of improving maternal and fetal outcomes.


Assuntos
Cardiologistas , Doenças Cardiovasculares , Obstetrícia , Gravidez , Feminino , Humanos , Estados Unidos , Doenças Cardiovasculares/terapia , Bolsas de Estudo , Obstetrícia/educação , Cuidado Pré-Natal
19.
Am J Cardiol ; 193: 1-18, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36857839

RESUMO

Since the first transcatheter delivery of an aortic valve prosthesis was performed by Cribier et al in 2002, the picture of aortic stenosis (AS) therapeutics has changed dramatically. Initiated from an indication of inoperable to high surgical risk, extending to intermediate and low risk, transcatheter aortic valve replacement (TAVR) is now an approved treatment for patients with severe, symptomatic AS across all the risk categories. The current evidence supports TAVR as a frontline therapy for treating severe AS. The crucial question remains concerning the subset of patients who still are not ideal candidates for TAVR because of certain inherent anatomic, nonmodifiable, and procedure-specific factors. Therefore, in this study, we focus on these scenarios and reasons for referring selected patients for surgical aortic valve replacement in 2023.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
20.
Int J Cardiol ; 371: 305-311, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272571

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SLT) is characterized on computed tomography (CT) imaging as hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM). How antithrombotic regimen type impacts SLT remains poorly understood. We evaluated how antithrombotic regimen type impacts SLT in low-risk subjects following transcatheter aortic valve implantation (TAVI). METHODS: This substudy is a post hoc analysis of the LRT 1.0 and 2.0 trials to assess SLT in subjects who underwent CT or transoesophageal echocardiogram (TOE) imaging at 30 days, stratified by antithrombotic regimen received (single antiplatelet therapy [SAPT], dual antiplatelet therapy [DAPT], or oral anticoagulation). We also utilized univariable logistic regression modelling to identify echocardiographic predictors of HALT. RESULTS: Rates of HALT, RELM, and HAM were all significantly lower with oral anticoagulation compared to SAPT or DAPT at 30 days (HALT: 2.6% vs 14.3% vs 17.2%, respectively, with p < 0.001; RELM: 1.8% vs 9.6% vs 13.1%, respectively, with p = 0.004; and HAM: 0.9% vs 8.5% vs 9.8%, respectively, with p = 0.011). Additionally, short-term oral anticoagulation was not associated with higher bleeding rates compared to SAPT or DAPT (0.8% vs. 1.8% vs. 3.6%, p = 0.291). The presence of HALT did not significantly impact echocardiographic haemodynamic parameters at 30 days. CONCLUSION: This is the largest study to date that evaluated the impact of different antithrombotic regimens on SLT in low-risk TAVI patients. Oral anticoagulation was associated with significantly lower rates of SLT at 30 days compared to DAPT or SAPT, and there was no apparent benefit of DAPT over SAPT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fibrinolíticos/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA