Zhonghua Wai Ke Za Zhi ; 46(14): 1054-7, 2008 Jul 15.
Artigo em Zh | MEDLINE | ID: mdl-19094529

RESUMO

OBJECTIVE: To determine the value of the use of a pneumatic tourniquet in total knee arthroplasty. METHODS: Sixty patients were prospectively randomized into 2 groups, one group underwent total knee replacement with a tourniquet (n = 30) and one without (n = 30). Operating time, blood loss, postoperative mean morphine requirement, swelling, ecchymosis, earlier straight-leg raising and postoperative knee flexion were measured in both groups. RESULTS: There was no significant difference in the total blood loss between the 2 groups although the intraoperative blood loss was significantly greater in those without a tourniquet. The mean morphine requirement, postoperative swelling, scope of ecchymosis, earlier straight-leg raising and postoperative knee flexion in the patients that had surgery without a tourniquet were significantly better than those with a tourniquet. CONCLUSION: Knee arthroplasty operation with the use of a tourniquet has only small benefits on the total blood loss, but hinder in patients' early postoperative rehabilitation exercises.


Assuntos
Artroplastia do Joelho , Torniquetes , Idoso , Perda Sanguínea Cirúrgica/prevenção & controle , Feminino , Humanos , Masculino , Estudos Prospectivos , Torniquetes/efeitos adversos