Clin Chem Lab Med ; 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38008748

RESUMO

OBJECTIVES: This paper evaluates 16 year results of the Allergy EQA program shared by EQA organisers in Belgium, Finland, Portugal, and The Netherlands. METHODS: The performance of Thermo Fisher and Siemens user groups (in terms of concordance between both groups, between laboratory CV, prevalence of clinically significant errors) and suitability of samples (stability and validity of dilution of patient samples) are evaluated using data of 192 samples in the EQA programs from 2007 to 2022. Measurands covered are total IgE, screens and mixes, specific IgE extracts and allergen components. RESULTS: There is perfect (53 %), acceptable (40 %) and poor (6 %) concordance between both method groups. In case of poor concordance the best fit with clinical data is seen for Thermo Fisher (56 %) and Siemens (26 %) respectively. The between laboratory CV evolves from 7.8 to 6.6 % (Thermo Fisher) and 7.3 to 7.7 % (Siemens). The prevalence of blunders by individual laboratories is stable for Siemens (0.4 %) and drops from 0.4 to 0.2 % for Thermo Fisher users. For IgE, the between year CV of the mean of both user groups is 1 %, and a fifteen-fold dilution of a patient sample has an impact of 2 and 4 % on the recovery of Thermo Fisher and Siemens user groups. CONCLUSIONS: The analytical performance of Thermo Fisher is slightly better than that of Siemens users but the clinical impact of this difference is limited. Stability of the sample and the low impact of dilution on the recovery of measurands demonstrates the suitability for purpose of the EQA program.

2.
Clin Chem Lab Med ; 59(5): 965-970, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33554536

RESUMO

OBJECTIVES: Hemoglobin A1c (HbA1c) is a valuable parameter in the monitoring of diabetic patients and increasingly in diagnosis of diabetes. Manufacturers continuously optimize instruments, currently the main focus is to achieve faster turnaround times. It is important that performance specifications remain of high enough standard, which is evaluated in this study for the new ARKRAY HA-8190V instrument. METHODS: The Clinical and Laboratory Standards Institute (CLSI) protocols EP-5, EP-9 and EP-10 were applied to investigate imprecision, bias and linearity. In addition potential interferences, performance in External Quality Assessment (EQA) and performance against the HA-8180V instrument in 220 clinical samples was evaluated. RESULTS: The HA-8190V demonstrates a CV of ≤0.8% in IFCC SI units (≤0.6% National Glycohemoglobin Standardization Program [NGSP]) at 34 and 102 mmol/mol levels (5.3 and 11.5% NGSP) and a bias of -0.1 mmol/mol (-0.01% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP), but with a significant slope as compared to target values. This results in a bias of -1.0 and 0.9 mmol/mol (-2.0 and 0.9% NGSP) at the 30 and 70 mmol/mol (4.9 and 8.6% NGSP) concentration level. Simulation of participation in the IFCC certification programme results in a Silver score (bias -0.1 mmol/mol, CV 1.1%). Interference in the presence of the most important Hb variants (AS, AC, AE, AD) and elevated HbA2 and HbF concentrations is less than 3 mmol/mol (0.3% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP). CONCLUSIONS: Analytical performance of the HA-8190V is very good, especially with respect to precision and HbA1c quantification in the presence of the most common Hb variants.


Assuntos
Diabetes Mellitus , Hemoglobinas Glicadas/análise , Humanos , Padrões de Referência
3.
Clin Chem ; 66(6): 769-778, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32335671

RESUMO

Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs. A conclusion regarding commutability or noncommutability requires that the magnitude of the difference in bias observed in the commutability assessment remains unchanged over time. This conclusion requires the CRM to be stable and no substantive changes in the MPs. These conditions should be periodically reverified. If an available CRM is determined to be noncommutable for a specific MP, that CRM can be used in the calibration hierarchy for that MP when an appropriately validated MP-specific correction for the noncommutability bias is included. We describe with examples how a MP-specific correction and its uncertainty can be developed and applied in a calibration hierarchy to achieve metrological traceability of results for CSs to the CRM's assigned value.


Assuntos
Viés , Guias como Assunto , Kit de Reagentes para Diagnóstico/normas , Calibragem , Humanos , Padrões de Referência
4.
J Inherit Metab Dis ; 43(2): 179-188, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31433494

RESUMO

Analysis of blood phenylalanine is central to the monitoring of patients with phenylketonuria (PKU) and age-related phenylalanine target treatment-ranges (0-12 years; 120-360 µmol/L, and >12 years; 120-600 µmol/L) are recommended in order to prevent adverse neurological outcomes. These target treatment-ranges are based upon plasma phenylalanine concentrations. However, patients are routinely monitored using dried bloodspot (DBS) specimens due to the convenience of collection. Significant differences exist between phenylalanine concentrations in plasma and DBS, with phenylalanine concentrations in DBS specimens analyzed by flow-injection analysis tandem mass spectrometry reported to be 18% to 28% lower than paired plasma concentrations analyzed using ion-exchange chromatography. DBS specimens with phenylalanine concentrations of 360 and 600 µmol/L, at the critical upper-target treatment-range thresholds would be plasma equivalents of 461 and 768 µmol/L, respectively, when a reported difference of 28% is taken into account. Furthermore, analytical test imprecision and bias in conjunction with pre-analytical factors such as volume and quality of blood applied to filter paper collection devices to produce DBS specimens affect the final test results. Reporting of inaccurate patient results when comparing DBS results to target treatment-ranges based on plasma concentrations, together with inter-laboratory imprecision could have a significant impact on patient management resulting in inappropriate dietary change and potentially adverse patient outcomes. This review is intended to provide perspective on the issues related to the measurement of phenylalanine in blood specimens and to provide direction for the future needs of PKU patients to ensure reliable monitoring of metabolic control using the target treatment-ranges.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Fenilalanina/sangue , Fenilcetonúrias/sangue , Aminoácidos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Teste em Amostras de Sangue Seco/instrumentação , Humanos , Espectrometria de Massas em Tandem/métodos
5.
Clin Chem Lab Med ; 59(1): 117-125, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32759402

RESUMO

Objectives: External quality assessment (EQA) with commutable samples is used for assessing agreement of results for patients' samples. We investigated the feasibility to aggregate results from four different EQA schemes to determine the bias between different measurement procedures and a reference target value. Methods: We aggregated EQA results for creatinine from programs that used commutable EQA material by calculating the relative difference between individual participant results and the reference target value for each sample. The means and standard errors of the means were calculated for the relative differences. Results were partitioned by methods, manufacturers and instrument platforms to evaluate the biases for the measurement procedures. Results: Data aggregated for enzymatic methods had biases that varied from -8.2 to 3.8% among seven instrument platforms for creatinine at normal concentrations (61-85 µmol/L). EQA schemes differed in the evidence provided about the commutability of their samples, and in the amount of detail collected from participants regarding the measurement procedures which limited the ability to sub-divide aggregated data by instrument platforms and models. Conclusions: EQA data could be aggregated from four different programs using different commutable samples to determine bias among different measurement procedures. Criteria for commutability for EQA samples as well as standardization of reporting the measurement methods, reagents, instrument platforms and models used by participants are needed to improve the ability to aggregate the results for optimal assessment of performance of measurement procedures. Aggregating data from a larger number of EQA schemes is feasible to assess trueness on a global scale.


Assuntos
Análise Química do Sangue/normas , Creatinina/sangue , Análise Química do Sangue/estatística & dados numéricos , Agregação de Dados , Estudos de Viabilidade , Humanos , Países Baixos , Noruega , Controle de Qualidade , Reino Unido , Estados Unidos
6.
Clin Chem Lab Med ; 59(2): 315-323, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001847

RESUMO

Objectives: Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. Methods: We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. Results: The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07±0.24 nmol/L. Conclusions: We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success.


Assuntos
Hepcidinas/sangue , Acreditação , Coleta de Amostras Sanguíneas , Calibragem , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Humanos , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Padrões de Referência , Espectrometria de Massas em Tandem
7.
Clin Chem Lab Med ; 57(6): 864-872, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30485171

RESUMO

Background Hepcidin concentrations measured by various methods differ considerably, complicating interpretation. Here, a previously identified plasma-based candidate secondary reference material (csRM) was modified into a serum-based two-leveled sRM. We validated its functionality to increase the equivalence between methods for international standardization. Methods We applied technical procedures developed by the International Consortium for Harmonization of Clinical Laboratory Results. The sRM, consisting of lyophilized serum with cryolyoprotectant, appeared commutable among nine different measurement procedures using 16 native human serum samples in a first round robin (RR1). Harmonization potential of the sRM was simulated in RR1 and evaluated in practice in RR2 among 11 measurement procedures using three native human plasma samples. Comprehensive purity analysis of a candidate primary RM (cpRM) was performed by state of the art procedures. The sRM was value assigned with an isotope dilution mass spectrometry-based candidate reference method calibrated using the certified pRM. Results The inter-assay CV without harmonization was 42.1% and 52.8% in RR1 and RR2, respectively. In RR1, simulation of harmonization with sRM resulted in an inter-assay CV of 11.0%, whereas in RR2 calibration with the material resulted in an inter-assay CV of 19.1%. Both the sRM and pRM passed international homogeneity criteria and showed long-term stability. We assigned values to the low (0.95±0.11 nmol/L) and middle concentration (3.75±0.17 nmol/L) calibrators of the sRM. Conclusions Standardization of hepcidin is possible with our sRM, which value is assigned by a pRM. We propose the implementation of this material as an international calibrator for hepcidin.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Hepcidinas/sangue , Espectrometria de Massas em Tandem , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Ensaio de Imunoadsorção Enzimática/normas , Hepcidinas/normas , Humanos , Marcação por Isótopo , Padrões de Referência , Espectrometria de Massas em Tandem/normas
8.
Clin Chem ; 64(3): 447-454, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348163

RESUMO

Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.


Assuntos
Técnicas de Laboratório Clínico/normas , Calibragem , Humanos , Padrões de Referência
9.
Clin Chem ; 64(3): 465-474, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348164

RESUMO

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrated.


Assuntos
Técnicas de Laboratório Clínico/normas , Padrões de Referência , Viés , Calibragem , Humanos
10.
Clin Chem ; 64(3): 455-464, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348165

RESUMO

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.


Assuntos
Técnicas de Laboratório Clínico/normas , Viés , Técnicas de Laboratório Clínico/estatística & dados numéricos , Interpretação Estatística de Dados , Humanos , Padrões de Referência , Manejo de Espécimes/normas , Incerteza
11.
Clin Chem Lab Med ; 57(2): 288-295, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30044761

RESUMO

Background Diabetes mellitus is a major global issue and high quality testing is essential for the diagnosis and treatment of the disease. The IFCC Committee for the Education in the Utility of Biomarkers in Diabetes (C-EUBD) plays a global role in improving knowledge and understanding around diabetes testing. This paper describes a multi-stakeholder approach, to improving diagnostic and therapeutic testing for diabetes, using a multicentre study in China as an example of the global impact of the group. Methods Educational workshops were developed to support the scientific aims of the study in which 30 centres around China received identical, fresh frozen whole blood samples with values assigned using IFCC secondary reference methods and undertook precision (EP-5) and trueness studies. Performance was assessed using sigma metrics. Results A successful multi-stakeholder group was developed and sustained throughout the study through several educational workshops, which enabled the formation of a long-term collaboration with key opinion leaders and policy makers in China. All 30 centres showed good performance with within and between laboratory coefficient of variations (CVs) below 3% in SI units at both low and high haemoglobin A1c (HbA1c) levels. All individual laboratories met the criteria of a sigma of two or more at a total allowable error (TAE) of 5 mmol/mol (0.46% NGSP). Conclusions The study led to a successful multi-partner approach to improving diabetes testing in China. All centres involved in the study meeting the published IFCC quality criteria, paving the way for future clinical trials and an expanded role for HbA1c testing across the country.


Assuntos
Química Clínica , Diabetes Mellitus/sangue , Hemoglobinas Glicadas/análise , Controle de Qualidade , China , Humanos
12.
Clin Chem Lab Med ; 55(10): 1509-1516, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28182577

RESUMO

BACKGROUND: To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. METHODS: Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. RESULTS: The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. CONCLUSIONS: By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.


Assuntos
Laboratórios/normas , Química Clínica/normas , Técnicas de Laboratório Clínico/normas , Controle de Qualidade
13.
Clin Chem Lab Med ; 55(2): 203-211, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27447239

RESUMO

BACKGROUND: Optimum patient care in relation to laboratory medicine is achieved when results of laboratory tests are equivalent, irrespective of the analytical platform used or the country where the laboratory is located. Standardization and harmonization minimize differences and the success of efforts to achieve this can be monitored with international category 1 external quality assessment (EQA) programs. METHODS: An EQA project with commutable samples, targeted with reference measurement procedures (RMPs) was organized by EQA institutes in Italy, the Netherlands, Portugal, UK, and Spain. Results of 17 general chemistry analytes were evaluated across countries and across manufacturers according to performance specifications derived from biological variation (BV). RESULTS: For K, uric acid, glucose, cholesterol and high-density density (HDL) cholesterol, the minimum performance specification was met in all countries and by all manufacturers. For Na, Cl, and Ca, the minimum performance specifications were met by none of the countries and manufacturers. For enzymes, the situation was complicated, as standardization of results of enzymes toward RMPs was still not achieved in 20% of the laboratories and questionable in the remaining 80%. CONCLUSIONS: The overall performance of the measurement of 17 general chemistry analytes in European medical laboratories met the minimum performance specifications. In this general picture, there were no significant differences per country and no significant differences per manufacturer. There were major differences between the analytes. There were six analytes for which the minimum quality specifications were not met and manufacturers should improve their performance for these analytes. Standardization of results of enzymes requires ongoing efforts.


Assuntos
Análise Química do Sangue , Colesterol/sangue , Enzimas/sangue , Glucose/análise , Ácido Úrico/sangue , Cálcio/sangue , Cloretos/sangue , Enzimas/metabolismo , Humanos , Países Baixos , Portugal , Potássio/sangue , Sódio/sangue , Espanha , Reino Unido
14.
Clin Chem ; 62(7): 993-1001, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27173010

RESUMO

BACKGROUND: Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. METHODS: We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. RESULTS: Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. CONCLUSIONS: The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results.


Assuntos
Serviços de Laboratório Clínico/normas , Hepcidinas/sangue , Cooperação Internacional , Humanos , Imunoquímica , Modelos Lineares , Padrões de Referência
15.
Clin Chem Lab Med ; 54(11): 1769-1775, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27171390

RESUMO

BACKGROUND: External quality assessment/proficiency test (EQA/PT) organizers play an important role in monitoring the performance of HbA1c measurements. With increasing quality of the assays, HbA1c is increasingly used for diagnosis of diabetes and the demands on EQA/PT organizers themselves are rising constantly. EQA organizers in Germany (INSTAND), Belgium (WIV/IPV), and the Netherlands (SKML) organized a program with commutable samples and target values assigned with the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference system. The aim of this project was to confirm the logistic feasibility of organizing synchronically in the three countries, an accuracy-based EQA program with fresh whole blood, to investigate the performance of HbA1c assays within and across countries and manufacturers, and to review the EQA acceptance limits. METHODS: Throughout 2015, ten fresh whole blood samples were supplied to the participants. Aggregated results were evaluated according to the IFCC model for quality targets at four levels: overall, per country, per manufacturer, and per country per manufacturer. RESULTS: Robust results in summer and winter demonstrated the feasibility of organizing an EQA with fresh whole blood samples in three countries. The overall performances, as well as the performance for each country were very similar: results fell within the IFCC criteria. Although substantial differences between results from different manufacturers were present, the performances of laboratories using tests of the same manufacturer were strikingly similar in the three countries, suggesting that the quality of HbA1c assays is for the most part manufacturer- related. The improved design of the EQA program also suggested that acceptance limits for performance can be reduced to approximately 8%.


Assuntos
Coleta de Amostras Sanguíneas , Diabetes Mellitus/sangue , Hemoglobinas Glicadas/análise , Garantia da Qualidade dos Cuidados de Saúde , Bélgica , Diabetes Mellitus/diagnóstico , Alemanha , Humanos , Países Baixos , Garantia da Qualidade dos Cuidados de Saúde/normas , Padrões de Referência
16.
Clin Chem Lab Med ; 54(4): 609-16, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26457777

RESUMO

BACKGROUND: The aim of this study was to compare different analytical methods that are currently in use in the Netherlands for the measurement of whole blood vitamin B6. METHODS: This method comparison study consisted of two separate parts. (1) Four laboratories participated in a pilot study in which the commercial Chromsystems and INstruchemie method, and a laboratory developed liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and HPLC method were compared. Sixty-nine frozen whole blood samples and six lyophilized whole blood samples were used for comparison. (2) In the nationwide part of the study, 49 laboratories participated in the analysis of three identical sets of two whole blood samples of which one set was freshly analyzed, one set was analyzed after storage at -20 °C and one set was analyzed after lyophilization. RESULTS: In both parts of the study, the HPLC and LC-MS/MS methods showed equivalent results for all sample types tested. The Chromsystems method showed a positive bias of 45% (pilot study) and 30% (nationwide study) towards the LC-MS/MS method when fresh or frozen samples were used. The measurement of lyophilized samples showed no differences between the methods. The results of the INstruchemie method were inconclusive due to the low number of participants. CONCLUSIONS: The different analytical methods for measuring vitamin B6 produce different results when whole blood patient samples are measured. The recognition of a reference method or the development of suitable reference materials and quality control materials might serve as a first step towards improved standardization or harmonization of the whole blood vitamin B6 assay.


Assuntos
Análise Química do Sangue , Técnicas de Laboratório Clínico , Vitamina B 6/sangue , Cromatografia Líquida , Humanos , Estudos Multicêntricos como Assunto , Projetos Piloto , Espectrometria de Massas em Tandem
17.
Clin Chem ; 61(5): 752-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25737535

RESUMO

BACKGROUND: A major objective of the IFCC Task Force on Implementation of HbA1c Standardization is to develop a model to define quality targets for glycated hemoglobin (Hb A1c). METHODS: Two generic models, biological variation and sigma-metrics, are investigated. We selected variables in the models for Hb A1c and used data of external quality assurance/proficiency testing programs to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. RESULTS: In the biological variation model, 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the sigma-metrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP), 77% of the individual laboratories and 12 of 26 instrument groups met the 2σ criterion. CONCLUSIONS: The biological variation and sigma-metrics models were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The sigma-metrics model is more flexible, as both the TAE and the risk of failure can be adjusted to the situation-for example, requirements related to diagnosis/monitoring or international authorities. With the aim of reaching (inter)national consensus on advice regarding quality targets for Hb A1c, the Task Force suggests the sigma-metrics model as the model of choice, with default values of 5 mmol/mol (0.46%) for TAE and risk levels of 2σ and 4σ for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes.


Assuntos
Hemoglobinas Glicadas/metabolismo , Modelos Biológicos , Hemoglobinas Glicadas/normas , Humanos , Laboratórios
18.
Clin Chem Lab Med ; 53(2): 319-27, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25274956

RESUMO

BACKGROUND: The accurate and precise quantification of HbA1c is essential for the diagnosis and routine monitoring of patients with diabetes. We report an evaluation of the Trinity Biotech Premier Hb9210 analyser (Bray, Ireland/Kansas City, MO, USA), a boronate affinity chromatography-based high performance liquid chromatography (HPLC) system for the measurement of glycated haemoglobin. METHODS: We evaluated the analytical performance of the Hb9210 as part of a multicentre evaluation. The effect of haemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) reference systems, was assessed. Most of the centres participating also act as reference laboratories for both the IFCC standardisation network for HbA1c and the NGSP. RESULTS: The combined data from all centres showed total coefficients of variation (CV) of 2.71%, 2.32% and 2.14% at low, medium and high values, respectively, for mmol/mol (SI units) and 1.62%, 1.59% and 1.68% for % (NGSP units), which are well below the recommended upper limits of 3% CV for mmol/mol (SI units) and 2% CV for % (NGSP). The analyser showed a good correlation to HbA1c methods currently used in clinical practice and the IFCC reference method procedure. Haemoglobin variants AC, AS, AE and AD do not affect the measurement of HbA1c. Overall the Hb9210 performs well across the whole analytical range. CONCLUSIONS: The Hb9210 performs well and is suitable for clinical application in the analysis of HbA1c.


Assuntos
Hemoglobinas Glicadas/análise , Cromatografia Líquida de Alta Pressão , Humanos , Estudos Multicêntricos como Assunto , Sensibilidade e Especificidade
19.
Clin Chem Lab Med ; 53(9): 1465-71, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26035110

RESUMO

BACKGROUND: Haemoglobin (Hb) variants are well-known factors interfering with accurate HbA1c testing. This report describes two novel Hb variants leading to inappropriate quantification of HbA1c by ion-exchange chromatography. METHODS: Glycated forms of novel Hb variants were recognised in the blood of two patients with diabetes mellitus screened by HbA1c ion-exchange chromatography. Dedicated high-resolution cation-exchange chromatography and subsequent DNA sequencing revealed the exact nature of the variants. Other common techniques for quantifying HbA1c were applied on both samples and haematological parameters were determined to judge possible pathology associated with the novel Hb variants. RESULTS: A fraction of 15% of abnormal Hb was observed in a 37-year-old female. DNA sequencing revealed a heterozygous mutation in the α1-globin gene, resulting in a leucine-to-phenylalanine amino-acid substitution (HBA1: c.301C>T, p.Leu101Phe). We named this variant Hb Weesp. The other novel variant, Hb Haelen, presented as a 40% fraction in a 63-year-old male and resulted from a heterozygous amino acid substitution in the ß-globin gene (HBB: c.335T>C, p.Val112Gly). The presence of both Hb variants resulted in aberrant separation of the Hb components, leading to an inadequate quantification of HbA1c. CONCLUSIONS: Close examination of HbA1c chromatograms revealed two novel, clinically silent Hb variants that interfere with HbA1c quantification. Healthcare providers need to be aware of the potential of such Hb variants when interpreting HbA1c results.


Assuntos
Análise Química do Sangue/métodos , Cromatografia por Troca Iônica/métodos , Hemoglobinas Glicadas/análise , Hemoglobinas Anormais/genética , Adulto , Cromatografia Líquida de Alta Pressão , Feminino , Hemoglobinas Glicadas/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Mutação
20.
Clin Chem ; 60(7): 945-53, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24691685

RESUMO

BACKGROUND: The need for equivalent results of routine measurement procedures for the alcohol biomarker carbohydrate-deficient transferrin (CDT) has been recognized by the IFCC. This article describes a project to harmonize CDT as conducted by an IFCC working group initiated for this purpose. METHODS: We used procedures for achieving harmonization as developed by the Consortium for Harmonization of Clinical Laboratory Results to assess the suitability of a candidate reference measurement procedure (cRMP), candidate reference materials (cRMs), and the success of efforts to achieve harmonization. RESULTS: CDT measurement procedures in routine use showed good reproducibility (CV 1.1%-2.8%) and linearity (r > 0.990) with variable slopes (0.766-1.065) and intercepts (-0.34 to 0.92) compared to the cRMP. Heterogeneity after simulated harmonization was 4.7%. cRMs of frozen human native sera demonstrated commutability and 3-year stability for routine measurement procedures. The cRMP provided reproducible value assignment to cRMs with an expanded uncertainty (k = 2) of 0.03% at the 1.2% CDT level and 0.06% at the 4.4% CDT level. Harmonization efforts reduced the intermeasurement CV from 8.8% to 3.4%, allowed 99% recovery of the values assigned with the cRMP, and demonstrated 99% of results within the desirable allowable total error. Harmonization was less successful in samples with low CDT and high trisialotransferrin concentrations. CONCLUSIONS: Harmonization of CDT is possible with frozen human native sera as cRMs with values assigned by use of the cRMP. We propose the cRMP as a candidate international conventional reference measurement procedure and cRMs as candidate international calibrators.


Assuntos
Consumo de Bebidas Alcoólicas/sangue , Transferrina/análogos & derivados , Biomarcadores/sangue , Cromatografia Líquida de Alta Pressão , Eletroforese Capilar , Humanos , Imunoensaio , Nefelometria e Turbidimetria , Padrões de Referência , Valores de Referência , Transferrina/análise , Transferrina/normas