Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Arthroplasty ; 33(8): 2652-2659.e3, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29615377

RESUMO

BACKGROUND: Correct positioning of the cup is an important factor in total hip arthroplasty. Assessing its position from a plain anteroposterior pelvic radiograph is known to be hampered by systemic errors. This study focuses on developing a correction method to adjust for these potential sources of error and to eliminate them based on a 3D geometric analysis. METHODS: Computed tomography scans of 113 (66 male, 47 female) pelvices were reconstructed and virtually projected onto a plain radiograph with varying rotational and translational positions. Thus cup inclination and anteversion as measured on a 2D-radiograph and in the 3D environment were correlated. Projected offset of the symphysis from the mid-sacrum served as a mean to measure pelvic right/left-rotation. Pelvic tilt was determined from the projected height of the contour of the small pelvis. Correction formulas were verified by projecting a gimbal-mounted artificial pelvis with a cup implanted in a known position. RESULTS: We found gender-specific formulas that correct for malrotated and off-centered radiographs. Applying these formulas cup inclination was assessed as close as 1.3° (±1.90°) to the true 3D value and cup anteversion as close as 1° (±1.91°) although deviations between directly measured plain values and corrected values rose up to 18°. CONCLUSION: Inherent effects of central projection and malrotations due to pelvic tilt, pelvic rotation, and noncentered radiographs are corrected. Evaluation of radiographic inclination and anteversion of acetabular cups from plain 2D-radiographs show improved precision. Real values are approached better than 1.3° when applying our correction formulas.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Pelve/diagnóstico por imagem , Pelve/cirurgia , Radiografia , Rotação , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA