Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(18)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37762555

RESUMO

Uremic toxins exert pathophysiological effects on cells and tissues, such as the generation of a pro-calcifying subtype of exosome-like extracellular vesicles (EVs) in vascular cells. Little is known about the effects of the toxins on the surface structure of EVs. Thus, we studied the effects of uremic toxins on the abundance of sulfated glycosaminoglycans (GAGs) in EVs, and the implications for binding of ligands such as very small superparamagnetic iron oxide particles (VSOPs) which could be of relevance for radiological EV-imaging. Vascular cells were treated with the uremic toxins NaH2PO4 and a mixture of urea and indoxyl sulfate. Uremia in rats was induced by adenine feeding. EVs were isolated from culture supernatants and plasma of rats. By proton T1-relaxometry, magnetic particle spectroscopy, and analysis of genes, proteins, and GAG-contents, we analyzed the roles of GAGs in the ligand binding of EVs. By influencing GAG-associated genes in host cells, uremic toxins induced higher GAG contents in EVs, particularly of sulfated chondroitin sulfate and heparan sulfate chains. EVs with high GAG content interacted stronger with VSOPs compared to control ones. This was confirmed by experiments with GAG-depleted EVs from genetically modified CHO cells and with uremic rat-derived EVs. Mechanistically, uremic toxin-induced PI3K/AKT-signaling and expression of the sulfate transporter SLC26A2 in host cells contributed to high GAG contents in EVs. In conclusion, uremic conditions induce enhanced GAG contents in EVs, which entails a stronger interaction with VSOPs. VSOPs might be suitable for radiological imaging of EVs rich in GAGs.


Assuntos
Exossomos , Vesículas Extracelulares , Toxinas Biológicas , Animais , Ratos , Cricetinae , Toxinas Urêmicas , Cricetulus , Fosfatidilinositol 3-Quinases , Glicosaminoglicanos , Nanopartículas Magnéticas de Óxido de Ferro
2.
Sensors (Basel) ; 21(21)2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34770373

RESUMO

The use of magnetic nanoparticles (MNPs) in biomedical applications requires the quantitative knowledge of their quantitative distribution within the body. AC Biosusceptometry (ACB) is a biomagnetic technique recently employed to detect MNPs in vivo by measuring the MNPs response when exposed to an alternate magnetic field. The ACB technique presents some interesting characteristics: non-invasiveness, low operational cost, high portability, and no need for magnetic shielding. ACB conventional methods until now provided only qualitative information about the MNPs' mapping in small animals. We present a theoretical model and experimentally demonstrate the feasibility of ACB reconstructing 2D quantitative images of MNPs' distributions. We employed an ACB single-channel scanning approach, measuring at 361 sensor positions, to reconstruct MNPs' spatial distributions. For this, we established a discrete forward problem and solved the ACB system's inverse problem. Thus, we were able to determine the positions and quantities of MNPs in a field of view of 5×5×1 cm3 with good precision and accuracy. The results show the ACB system's capabilities to reconstruct the quantitative spatial distribution of MNPs with a spatial resolution better than 1 cm, and a sensitivity of 1.17 mg of MNPs fixed in gypsum. These results show the system's potential for biomedical application of MNPs in several studies, for example, electrochemical-functionalized MNPs for cancer cell targeting, quantitative sensing, and possibly in vivo imaging.


Assuntos
Nanopartículas de Magnetita , Animais , Diagnóstico por Imagem , Campos Magnéticos , Magnetismo , Cintilografia
3.
Int J Mol Sci ; 22(12)2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34207769

RESUMO

Colloidal stability of magnetic iron oxide nanoparticles (MNP) in physiological environments is crucial for their (bio)medical application. MNP are potential contrast agents for different imaging modalities such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI). Applied as a hybrid method (MRI/MPI), these are valuable tools for molecular imaging. Continuously synthesized and in-situ stabilized single-core MNP were further modified by albumin coating. Synthesizing and coating of MNP were carried out in aqueous media without using any organic solvent in a simple procedure. The additional steric stabilization with the biocompatible protein, namely bovine serum albumin (BSA), led to potential contrast agents suitable for multimodal (MRI/MPI) imaging. The colloidal stability of BSA-coated MNP was investigated in different sodium chloride concentrations (50 to 150 mM) in short- and long-term incubation (from two hours to one week) using physiochemical characterization techniques such as transmission electron microscopy (TEM) for core size and differential centrifugal sedimentation (DCS) for hydrodynamic size. Magnetic characterization such as magnetic particle spectroscopy (MPS) and nuclear magnetic resonance (NMR) measurements confirmed the successful surface modification as well as exceptional colloidal stability of the relatively large single-core MNP. For comparison, two commercially available MNP systems were investigated, MNP-clusters, the former liver contrast agent (Resovist), and single-core MNP (SHP-30) manufactured by thermal decomposition. The tailored core size, colloidal stability in a physiological environment, and magnetic performance of our MNP indicate their ability to be used as molecular magnetic contrast agents for MPI and MRI.


Assuntos
Materiais Revestidos Biocompatíveis/química , Meios de Contraste/química , Nanopartículas Magnéticas de Óxido de Ferro/química , Imageamento por Ressonância Magnética , Soroalbumina Bovina/química , Animais , Bovinos
4.
Nanotechnology ; 31(49): 495101, 2020 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-32946423

RESUMO

This paper elucidates the feasibility of magnetic drug targeting to the eye by using magnetic nanoparticles (MNPs) to which pharmaceutical drugs can be linked. Numerical simulations revealed that a magnetic field gradient of 20 T m-1 seems to be promising for dragging magnetic multicore nanoparticles of about 50 nm into the eye. Thus, a targeting magnet system made of superconducting magnets with a magnetic field gradient at the eye of about 20 T m-1 was simulated. For the proof-of-concept tissue experiments presented here the required magnetic field gradient of 20 T m-1 was realized by a permanent magnet array. MNPs with an optimized multicore structure were selected for this application by evaluating their stability against agglomeration of MNPs with different coatings in water for injections, physiological sodium chloride solution and biological media such as artificial tear fluid. From these investigations, starch turned out to be the most promising coating material because of its stability in saline fluids due to its steric stabilization mechanism. To evaluate the passage of MNPs through the sclera and cornea of the eye tissues of domestic pigs (Sus scrofa domesticus), a three-dimensionally printed setup consisting of two chambers (reservoir and target chamber) separated by the eye tissue was developed. With the permanent magnet array emulating the magnetic field gradient of the superconducting setup, experiments on magnetically driven transport of the MNPs from the reservoir chamber into the target chamber via the tissue were performed. The resulting concentration of MNPs in the target chamber was determined by means of quantitative magnetic particle spectroscopy. It was found that none of the tested particles passed the cornea, but starch-coated particles could pass the sclera at a rate of about 5 ng mm-2 within 24 h. These results open the door for future magnetic drug targeting to the eye.


Assuntos
Portadores de Fármacos/análise , Sistemas de Liberação de Medicamentos/métodos , Olho/metabolismo , Nanopartículas de Magnetita/análise , Administração Oftálmica , Animais , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/farmacocinética , Humanos , Campos Magnéticos , Magnetismo/métodos , Nanopartículas de Magnetita/administração & dosagem , Sus scrofa
5.
Sensors (Basel) ; 20(3)2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-32013245

RESUMO

For biomagnetical applications exploiting physical properties of magnetic nanoparticles (MNP), e.g., magnetic hyperthermia, knowledge about the quantitative spatial MNP distribution is crucial, which can be extracted by magnetorelaxometry (MRX) imaging. In this paper, we present quantification, quantitative 1D reconstruction, and quantitative 2D imaging of MNP by exploiting optically pumped magnetometers for MRX. While highlighting the potential of commercially available optically pumped magnetometers (OPM) for MRXI, we discuss current limitations of the used OPM. We show, that with our OPM setup, MNP can be precisely quantified with iron amounts down to ≈ 6 g , which can be improved easily. With a 1D-reconstruction setup, point-like and complex MNP phantoms can be reconstructed quantitatively with high precision and accuracy. We show that with our developed 2D MRX imaging setup, which measures 12 c m by 8 c m , point-like MNP distributions with clinically relevant iron concentrations can be reconstructed precisely and accurately. Our 2D setup has the potential to be easily extended to a tomography styled (and thus slice-selective) 3D scanner, by adding a mechanical axis to the phantom.

6.
Nanotechnology ; 30(18): 184004, 2019 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-30699387

RESUMO

The internalization kinetics resulting from magnetic nanoparticle interactions with tumor cells play an important role in nanoparticle-based cancer treatment efficiency. Here, the uptake kinetics of magnetoliposomes (ML) into human pancreatic tumor cells (MiaPaCa-2 and BxPC-3) are quantified using magnetic particle spectrometry. A comparison to the uptake kinetics for healthy L929 cells is given. The experimental results are used for the development of an uptake kinetics model describing the three relevant internalization processes: ML adsorption to the cell membrane, endo- and exocytosis. By fitting of experimental data, the rate constant of each internalization process is determined enabling the prediction of internalized ML at any incubation time. After seven hours incubation time, MiaPaCa-2 internalized three times more ML than BxPC-3 and L929 cells even though their ML adsorption rate constants were nearly the same. As the interaction of the ML with the cell membrane is non-specific, the uptake kinetics mirror the individual cell response to ML internalization. With a new mathematical term to cover the exocytosis contribution to the overall internalization process, the extended uptake kinetics model offers new possibilities to analyze the specific internalization mechanism for other nanoparticle and cell types.


Assuntos
Membrana Celular , Magnetismo , Modelos Biológicos , Nanopartículas/uso terapêutico , Neoplasias Pancreáticas , Animais , Linhagem Celular Tumoral , Membrana Celular/metabolismo , Membrana Celular/patologia , Endocitose , Exocitose , Humanos , Cinética , Lipossomos , Camundongos , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia
7.
Nanomedicine ; 14(8): 2575-2586, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30179669

RESUMO

We investigated the biotransformation of very small superparamagnetic iron oxide nanoparticles (VSOP) in atherosclerotic LDLR-/- mice. Transmission electron microscopy revealed an uptake of VSOP not only by macrophages but also by endothelial cells in liver, spleen, and atherosclerotic lesions and their accumulation in the lysosomal compartment. Using magnetic particle spectroscopy (MPS), we show that the majority of VSOP's superparamagnetic iron was degraded within 28 days. MPS spectrum shape indicated changes in the magnetic properties of VSOP during the biodegradation process. Experiments with primary murine bone marrow derived macrophages, primary murine liver sinusoidal endothelial cells, and primary human aortic endothelial cells demonstrated that loading with VSOP induced a differential response of cellular iron homeostasis mechanisms with increased levels of ferritin and iron transport proteins in macrophages and increased levels of ferritin in endothelial cells.


Assuntos
Aterosclerose/metabolismo , Compostos Férricos/química , Compostos Férricos/metabolismo , Nanopartículas de Magnetita/administração & dosagem , Receptores de LDL/fisiologia , Animais , Aorta/citologia , Aorta/metabolismo , Aterosclerose/fisiopatologia , Capilares/citologia , Capilares/metabolismo , Proliferação de Células , Células Cultivadas , Endotélio Vascular/citologia , Endotélio Vascular/metabolismo , Ferritinas/metabolismo , Humanos , Macrófagos/citologia , Macrófagos/metabolismo , Nanopartículas de Magnetita/química , Masculino , Camundongos , Camundongos Knockout
8.
Nanomedicine ; 12(8): 2353-2364, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27389150

RESUMO

Genetic modulation of angiogenesis is a powerful tool for the treatment of multiple disorders. Here, we describe a strategy to produce modified endothelial cells, which can be efficiently magnetically guided. First, we defined optimal transfection conditions with both plasmid and microRNA, using a polyethyleneimine/magnetic nanoparticle-based vector (PEI/MNP), previously designed in our group. Further, two approaches were assessed in vitro: direct vector guidance and magnetic targeting of transfected cells. Due to its higher efficiency, including simulated dynamic conditions, production of miR/PEI/MNP-modified magnetically responsive cells was selected for further detailed investigation. In particular, we have studied internalization of transfection complexes, functional capacities and intercellular communication of engineered cells and delivery of therapeutic miR. Moreover, we demonstrated that 104 miRNA/PEI/MNP-modified magnetically responsive cells loaded with 0.37pg iron/cell are detectable with MRI. Taken together, our in vitro findings show that PEI/MNP is highly promising as a multifunctional tool for magnetically guided angiogenesis regulation.


Assuntos
Magnetismo , MicroRNAs , Plasmídeos , DNA , Células Endoteliais , Nanotecnologia/métodos , Neovascularização Patológica , Polietilenoimina , Transfecção
9.
Nanomedicine ; 11(5): 1085-95, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25659644

RESUMO

To further optimize citrate-stabilized VSOPs (very small iron oxide particles, developed for MR angiography) for identification of atherosclerotic plaques, we modified their surface during synthesis using eight other acids for electrostatic stabilization. This approach preserves effective production for clinical application. Five particles were suitable to be investigated in targeting plaques of apoE(-/-) mice. Accumulation was evaluated by ex vivo MRI, TEM, and quantitatively by magnetic particle spectroscopy (MPS). Citric- (VSOP), etidronic-, tartaric-, and malic-acid-coated particles accumulated in atherosclerotic plaques with highest accumulation for VSOP (0.2‰ of injected dose). Targets were phagolysosomes of macrophages and of altered endothelial cells. In vivo MRI with VSOP allowed for definite plaque identification. Prussian blue staining revealed abundant endogenous iron in plaques, indistinguishable from particle iron. In apoE(-/-) mice, VSOPs are still the best anionic iron oxide particles for imaging atherosclerotic plaques. MPS allows for quantification of superparamagnetic nanoparticles in such small specimens. FROM THE CLINICAL EDITOR: The presence of vulnerable plaques in arteries is important for the prediction of acute coronary events. VSOP (very small iron oxide particles, developed for MR angiography) have been shown to be very sensitive in identifying atherosclerotic plaques. The authors studied here further modification to the surface of VSOP during synthesis and compared their efficacy.


Assuntos
Aorta/patologia , Compostos Férricos/química , Nanopartículas de Magnetita/química , Placa Aterosclerótica/patologia , Animais , Apolipoproteínas E/genética , Artérias Carótidas/patologia , Ácido Cítrico/química , Ácido Etidrônico/química , Compostos Férricos/farmacocinética , Ferrocianetos/análise , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita/análise , Malatos/química , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica de Transmissão , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/genética , Análise Espectral , Coloração e Rotulagem , Tartaratos/química
10.
Sci Rep ; 14(1): 4253, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-38378785

RESUMO

Magnetic Particle Imaging (MPI) is an advanced and powerful imaging modality for visualization and quantitative real-time detection of magnetic nanoparticles (MNPs). This opens the possibility of tracking cells in vivo once they have been loaded by MNPs. Imaging modalities such as optical imaging, X-ray computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI) face limitations, from depth of penetration and radiation exposure to resolution and quantification accuracy. MPI addresses these challenges, enabling radiation-free tracking of MNP-loaded cells with precise quantification. However, the real-time tracking of MNP-loaded cells with MPI has not been demonstrated yet. This study establishes real-time quantitative tracking of MNP-loaded cells. Therefore, THP-1 monocytes were loaded with three different MNP systems, including the MPI gold standard Resovist and Synomag. The real-time MPI experiments reveal different MPI resolution behaviors of the three MNP systems after cellular uptake. Real-time quantitative imaging was achieved by time-resolved cell number determination and comparison with the number of inserted cells. About 95% of the inserted cells were successfully tracked in a controlled phantom environment. These results underline the potential of MPI for real-time investigation of cell migration and interaction with tissue in vivo.


Assuntos
Imageamento por Ressonância Magnética , Nanopartículas de Magnetita , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Magnetismo , Imagens de Fantasmas
11.
Nanomaterials (Basel) ; 14(9)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38727367

RESUMO

Citrate-coated electrostatically stabilized very small superparamagnetic iron oxide particles (VSOPs) have been successfully tested as magnetic resonance angiography (MRA) contrast agents and are promising tools for molecular imaging of atherosclerosis. Their repeated use in the background of pre-existing hyperlipidemia and atherosclerosis has not yet been studied. This study aimed to investigate the effect of multiple intravenous injections of VSOPs in atherosclerotic mice. Taurine-formulated VSOPs (VSOP-T) were repeatedly intravenously injected at 100 µmol Fe/kg in apolipoprotein E-deficient (ApoE KO) mice with diet-induced atherosclerosis. Angiographic imaging was carried out by in vivo MRI. Magnetic particle spectrometry was used to detect tissue VSOP content, and tissue iron content was quantified photometrically. Pathological changes in organs, atherosclerotic plaque development, and expression of hepatic iron-related proteins were evaluated. VSOP-T enabled the angiographic imaging of heart and blood vessels with a blood half-life of one hour. Repeated intravenous injection led to VSOP deposition and iron accumulation in the liver and spleen without affecting liver and spleen pathology, expression of hepatic iron metabolism proteins, serum lipids, or atherosclerotic lesion formation. Repeated injections of VSOP-T doses sufficient for MRA analyses had no significant effects on plaque burden, steatohepatitis, and iron homeostasis in atherosclerotic mice. These findings underscore the safety of VSOP-T and support its further development as a contrast agent and molecular imaging tool.

12.
Nanomedicine ; 9(7): 961-71, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23669367

RESUMO

To treat tumours efficiently and spare normal tissues, targeted drug delivery is a promising alternative to conventional, systemic administered chemotherapy. Drug-carrying magnetic nanoparticles can be concentrated in tumours by external magnetic fields, preventing the nanomaterial from being cleared by metabolic burden before reaching the tumour. Therefore in Magnetic Drug Targeting (MDT) the favoured mode of application is believed to be intra-arterial. Here, we show that a simple yet versatile magnetic carrier-system (hydrodynamic particles diameter <200nm) accumulates the chemotherapeutic drug mitoxantrone efficiently in tumours. With MDT we observed the following drug accumulations relative to the recovery from all investigated tissues: tumour region: 57.2%, liver: 14.4%, kidneys: 15.2%. Systemic intra-venous application revealed different results: tumour region: 0.7%, liver: 14.4 % and kidneys: 77.8%. The therapeutic outcome was demonstrated by complete tumour remissions and a survival probability of 26.7% (P=0.0075). These results are confirming former pilot experiments and implying a milestone towards clinical studies. FROM THE CLINICAL EDITOR: This team of investigators studied drug carrying nanoparticles for magnetic drug targeting (MDT), demonstrating the importance of intra-arterial administration resulting in improved clinical outcomes in the studied animal model compared with intra-venous.


Assuntos
Sistemas de Liberação de Medicamentos , Nanopartículas de Magnetita/química , Mitoxantrona/uso terapêutico , Neoplasias/tratamento farmacológico , Animais , Feminino , Nanopartículas de Magnetita/ultraestrutura , Mitoxantrona/química , Mitoxantrona/farmacologia , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Neoplasias/patologia , Tamanho da Partícula , Coelhos , Radiografia , Espectrofotometria Infravermelho , Distribuição Tecidual
13.
Phys Med Biol ; 68(15)2023 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-37385264

RESUMO

Objective.Magnetorelaxomety imaging (MRXI) is a noninvasive imaging technique for quantitative detection of magnetic nanoparticles (MNPs). The qualitative and quantitative knowledge of the MNP distribution inside the body is a prerequisite for a number of arising biomedical applications, such as magnetic drug targeting and magnetic hyperthermia therapy. It was shown throughout numerous studies that MRXI is able to successfully localize and quantify MNP ensembles in volumes up to the size of a human head. However, deeper regions that lie far from the excitation coils and the magnetic sensors are harder to reconstruct due to the weaker signals from the MNPs in these areas. On the one hand, stronger magnetic fields need to be applied to produce measurable signals from such MNP distributions to further upscale MRXI, on the other hand, this invalidates the assumption of a linear relation between applied magnetic field and particle magnetization in the current MRXI forward model which is required for the imaging procedure.Approach.We tackle this problem by introducing a nonlinear MRXI forward model that is also valid for strong magnetic excitation fields.Main results.We demonstrate in our experimental feasibility study that scaling up the imaging region to the size of a human torso using nonlinear MRXI is possible. Despite the extreme simplicity of the imaging setup applied in this study, an immobilized MNP sample with 6.3 cm3and 12 mg Fe could be localized and quantified with an acceptable quality.Significance.A well-engineered MRXI setup could provide much better imaging qualities in shorter data acquisition times, making nonlinear MRXI a viable option for the supervision of MNP related therapies in all regions of the human body, specifically magnetic hyperthermia.


Assuntos
Hipertermia Induzida , Nanopartículas de Magnetita , Nanopartículas , Humanos , Diagnóstico por Imagem , Magnetismo , Campos Magnéticos
14.
RSC Adv ; 13(23): 15730-15736, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37235104

RESUMO

Magnetic particle imaging (MPI) is an imaging modality to quantitatively determine the three-dimensional distribution of magnetic nanoparticles (MNPs) administered as a tracer into a biological system. Magnetic particle spectroscopy (MPS) is the zero-dimensional MPI counterpart without spatial coding but with much higher sensitivity. Generally, MPS is employed to qualitatively evaluate the MPI capability of tracer systems from the measured specific harmonic spectra. Here, we investigated the correlation of three characteristic MPS parameters with the achievable MPI resolution from a recently introduced procedure based on a two-voxel-analysis of data taken from the system function acquisition that is mandatory in Lissajous scanning MPI. We evaluated nine different tracer systems and determined their MPI capability and resolution from MPS measurements and compared the results with MPI phantom measurements.

15.
Nanoscale Adv ; 5(8): 2341-2351, 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37056624

RESUMO

Thermal noise magnetometry (TNM) is a recently developed magnetic characterization technique where thermally induced fluctuations in magnetization are measured to gain insight into nanomagnetic structures like magnetic nanoparticles (MNPs). Due to the stochastic nature of the method, its signal amplitude scales with the square of the volume of the individual fluctuators, which makes the method therefore extra attractive to study MNP clustering and aggregation processes. Until now, TNM signals have exclusively been detected by using a superconducting quantum interference device (SQUID) sensor. In contrast, we present here a tabletop setup using optically pumped magnetometers (OPMs) in a compact magnetic shield, as a flexible alternative. The agreement between results obtained with both measurement systems is shown for different commercially available MNP samples. We argue that the OPM setup with low complexity complements the SQUID setup with high sensitivity and bandwidth. Furthermore, the OPM tabletop setup is well suited to monitor aggregation processes because of its excellent sensitivity in lower frequencies. As a proof of concept, we show the changes in the noise spectrum for three different MNP immobilization and clustering processes. From our results, we conclude that the tabletop setup offers a flexible and widely adoptable measurement unit to monitor the immobilization, aggregation, and clustering of MNPs for different applications, including interactions of the particles with biological systems and the long-term stability of magnetic samples.

16.
Phys Med Biol ; 68(17)2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37524086

RESUMO

Magnetorelaxometry imaging (MRXI) is a non-invasive, quantitative imaging technique for magnetic nanoparticles (MNPs). The image resolution of this technique significantly depends on the relaxation amplitude (ΔB). For this work, we measured the room temperature (299 K) relaxation signals of eight commercial MNP sample systems with different magnetic properties, in both fluid and immobilized states, in order to select the most suitable sample for a particular MRXI setting. Additionally, the effect of elevated temperatures (up to hyperthermia temperature, 335 K) on the relaxation signals of four different MNP systems (Synomag, Perimag, BNF and Nanomag) in both states were investigated. The ΔBvalues of fluid samples significantly decreased with increasing temperature, and the behaviour for immobilized samples depended on their blocking temperature (TB). For samples withTB< 299 K, ΔBalso decreased with increasing temperature. Whereas for samples withTB> 299 K, the opposite behaviour was observed. These results are beneficial for improving the image resolution in MRXI and show, among the investigated systems, and for our setup, Synomag is the best candidate for futurein vitroandin vivostudies. This is due to its consistently high ΔBbetween 299 and 335 K in both states. Our findings demonstrate the feasibility of temperature imaging by MRXI.


Assuntos
Nanopartículas de Magnetita , Temperatura , Diagnóstico por Imagem , Magnetismo , Fenômenos Físicos
17.
Nanoscale Adv ; 6(1): 247-255, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38125606

RESUMO

Widefield magnetometry based on nitrogen-vacancy centers enables high spatial resolution imaging of magnetic field distributions without a need for spatial scanning. In this work, we show nitrogen-vacancy center magnetic imaging of Fe3O4 nanoparticles within the gastrointestinal tract of Drosophila melanogaster larvae. Vector magnetic field imaging based on optically detected magnetic resonance is carried out on dissected larvae intestine organs containing accumulations of externally loaded magnetic nanoparticles. The distribution of the magnetic nanoparticles within the tissue can be clearly deduced from the magnetic stray field measurements. Spatially resolved magnetic imaging requires the nitrogen-vacancy centers to be very close to the sample making the technique particularly interesting for thin tissue samples. This study is a proof of principle showing the capability of nitrogen-vacancy center magnetometry as a technique to detect magnetic nanoparticle distributions in Drosophila melanogaster larvae that can be extended to other biological systems.

18.
Pharm Res ; 29(5): 1189-202, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22161287

RESUMO

Due to their biocompatibility and small size, iron oxide magnetic nanoparticles (MNP) can be guided to virtually every biological environment. MNP are susceptible to external magnetic fields and can thus be used for transport of drugs and genes, for heat generation in magnetic hyperthermia or for contrast enhancement in magnetic resonance imaging of biological tissue. At the same time, their magnetic properties allow one to develop sensitive and specific measurement methods to non-invasively detect MNP, to quantify MNP distribution in tissue and to determine their binding state. In this article, we review the application of magnetorelaxometry (MRX) for MNP detection. The underlying physical properties of MNP responsible for the generation of the MRX signal with its characteristic parameters of relaxation amplitude and relaxation time are described. Existing single and multi-channel MRX devices are reviewed. Finally, we thoroughly describe some applications of MRX to cellular MNP quantification, MNP organ distribution and MNP-based binding assays. Providing specific MNP signals, a detection limit down to a few nanogram MNP, in-vivo capability in conscious animals and measurement times of a few seconds, MRX is a valuable tool to improve the application of MNP for diagnostic and therapeutic purposes.


Assuntos
Compostos Férricos/química , Magnetismo , Nanopartículas Metálicas , Animais , Bioensaio , Sistemas de Liberação de Medicamentos , Humanos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/uso terapêutico
19.
Pharm Res ; 29(5): 1308-18, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22271050

RESUMO

PURPOSE: Targeted delivery of aerosols could not only improve efficacy of inhaled drugs but also reduce side effects resulting from their accumulation in healthy tissue. Here we investigated the impact of magnetized aerosols on model drug accumulation and transgene expression in magnetically targeted lung regions of unanesthetized mice. METHODS: Solutions containing superparamagnetic iron oxide nanoparticles (SPIONs) and model drugs (fluorescein or complexed plasmid DNA) were nebulized to unanesthetized mice under the influence of an external magnetic gradient directed to the lungs. Drug accumulation and transgene expression was subsequently measured at different time points. RESULTS: We could demonstrate 2-3 fold higher accumulation of the model drug fluorescein and specific transgene expression in lung regions of mice which had been exposed to an external magnetic gradient during nebulization compared to the control mice without any exposure to magnetic gradient. CONCLUSIONS: Magnetized aerosols present themselves as an efficient approach for targeted pulmonary delivery of drugs and gene therapeutic agents in order to treat localized diseases of the deeper airways.


Assuntos
Aerossóis/química , Sistemas de Liberação de Medicamentos , Compostos Férricos , Técnicas de Transferência de Genes , Pulmão/metabolismo , Magnetismo , Nanopartículas Metálicas , Animais , Feminino , Fluoresceína/farmacocinética , Fluoresceína/farmacologia , Regulação da Expressão Gênica , Vetores Genéticos/genética , Camundongos , Camundongos Endogâmicos BALB C , Plasmídeos/genética , Transgenes/genética
20.
Med Phys ; 49(5): 3361-3374, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35253916

RESUMO

BACKGROUND: Magnetorelaxometry imaging is an experimental imaging technique capable of reconstructing magnetic nanoparticle distributions inside a volume noninvasively and with high specificity. Thus, magnetorelaxometry imaging is a promising candidate for monitoring a number of therapeutical approaches that employ magnetic nanoparticles, such as magnetic drug targeting and magnetic hyperthermia, to guarantee their safety and efficacy. Prior to a potential clinical application of this imaging modality, it is necessary to optimize magnetorelaxometry imaging systems to produce reliable imaging results and to maximize the reconstruction accuracy of the magnetic nanoparticle distributions. Multiple optimization approaches were already applied throughout a number of simulation studies, all of which yielded increased imaging qualities compared to intuitively designed measurement setups. PURPOSE: None of these simulative approaches was conducted in practice such that it still remains unclear if the theoretical results are achievable in an experimental setting. In this study, we demonstrate the technical feasibility and the increased reconstruction accuracy of optimized coil configurations in two distinct magnetorelaxometry setups. METHODS: The electromagnetic coil positions and radii of a cuboidal as well as a cylindrical magnetorelaxometry imaging setup are optimized by minimizing the system matrix condition numbers of their corresponding linear forward models. The optimized coil configurations are manufactured alongside with two regular coil grids. Magnetorelaxometry measurements of three cuboidal and four cylindrical magnetic nanoparticle phantoms are conducted, and the resulting reconstruction qualities of the optimized and the regular coil configurations are compared. RESULTS: The computed condition numbers of the optimized coil configurations are approximately one order of magnitude lower compared to the regular coil grids. The reconstruction results show that for both setups, every phantom is recovered more accurately by the optimized coil configurations compared to the regular coil grids. Additionally, the optimized coil configurations yield better signal qualities. CONCLUSIONS: The presented experimental study provides a proof of the practicality and the efficacy of optimizing magnetorelaxometry imaging systems with respect to the condition numbers of their system matrices, previously only demonstrated in simulations. From the promising results of our study, we infer that the minimization of the system matrix condition number will also enable the practical optimization of other design parameters of magnetorelaxometry imaging setups (e.g., sensor configuration, coil currents, etc.) in order to improve the achievable reconstruction qualities even further, eventually paving the way towards clinical application of this imaging modality.


Assuntos
Diagnóstico por Imagem , Imageamento por Ressonância Magnética , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA