Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Surg ; 71(3): 774-779, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31327610

RESUMO

BACKGROUND: Evidence to guide management of postdissection abdominal aortic aneurysms (PDAAA) is lacking. This study describes the outcomes of open repair of PDAAA. METHODS: A retrospective cohort study was conducted of all consecutive patients treated with open repair for PDAAA after a Stanford type A or type B thoracic aortic dissection between January 2006 and December 2017 in two vascular referral centers. Preceding type B dissection treatment could include conservative or surgical management. Primary outcomes were 30-day mortality, complication rates, survival, and reintervention-free survival. Survival and reintervention-free survival were analyzed using the Kaplan-Meier method. Reintervention was defined as any endovascular or surgical intervention after the index procedure. RESULTS: Included were 36 patients (27 men [75%]) with a median age of 64 years (range, 35-81 years). The 30-day mortality was 2.7%. The median follow-up was 16 months (range, 0-88 months). The postoperative course was uneventful in 21 patients (58%). The most frequent complications were postoperative bleeding requiring repeat laparotomy (n = 4), pneumonia (n = 3), congestive heart failure (n = 2), new-onset atrial fibrillation (n = 2), mesenteric ischemia requiring left hemicolectomy (n=1), and ischemic cerebrovascular accident (n = 1). Renal failure requiring hemodialysis developed in one patient. The overall survival at 1 year was 88.8%. Reintervention-free survival was 95.5% after 1 year and 88.6% after 2 years. CONCLUSIONS: Open repair of PDAAA can be performed with a low mortality rate and an acceptable complication rate, comparable with elective open repair of abdominal aortic aneurysms without dissection.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Vasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Abdominal/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida
2.
J Endovasc Ther ; 26(1): 90-100, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30514134

RESUMO

PURPOSE: To review midterm clinical outcomes of EndoAnchor placement during or after endovascular aneurysm repair (EVAR) or chimney EVAR (ch-EVAR). MATERIALS AND METHODS: A retrospective analysis was conducted of 51 consecutive patients [median age 75 years; 38 men] who underwent EVAR/ch-EVAR with EndoAnchor placement between June 2010 and December 2016 to prevent seal failures (31, 61%) or to treat type Ia endoleak and/or migration (20, 39%). Median aortic neck diameter was 27.7 mm and median neck length was 9.0 mm. Thirty-three (65%) had a conical neck; 48 (94%) had at least 1 hostile neck characteristic. Thirty-two (63%) patients had severe comorbidities (ASA score ⩾III). Eight patients had a single ch-EVAR procedure. Baseline patient characteristics, anatomic variables, procedure details, early and late complications, reinterventions, and aneurysm-related and all-cause mortality rates were recorded. Follow-up imaging was performed with computed tomography angiography (CTA) or duplex ultrasonography. RESULTS: Median procedure time was 100 minutes; a median of 6 EndoAnchors were implanted. There were 10 (10%) residual type Ia endoleaks at the end of the procedure; 9 had resolved by the first postoperative CTA. One residual and 2 new type Ia endoleaks were identified at the first postoperative imaging. Median follow-up for the entire cohort was 24.0 months, during which 3 new type Ia endoleaks were identified. Five of the 6 type Ia endoleaks were treated, 1 resolved spontaneously. There was 1 endograft limb occlusion without clinical consequences, 1 chimney graft occlusion without possibilities for a reintervention, 1 rupture after type IV endoleak (a Nellix device was successfully deployed within the main device), and 1 complete graft explantation for infection. There was no new-onset hemodialysis. Kaplan-Meier estimates of freedom from type Ia endoleak, proximal neck-related reinterventions, and aneurysm-related mortality at 2 years were 87.3%, 92.2%, and 94.0%, respectively. CONCLUSION: EndoAnchors are helpful in the endovascular treatment of unfavorable proximal aortic necks, with fair midterm results.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervalo Livre de Progressão , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
3.
J Endovasc Ther ; 25(1): 52-61, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29219029

RESUMO

PURPOSE: To describe and validate a new methodology for visualizing and quantifying 3-dimensional (3D) displacement of the stent frames of the Nellix endosystem after endovascular aneurysm sealing (EVAS). METHODS: The 3D positions of the stent frames were registered to 5 fixed anatomical landmarks on the post-EVAS computed tomography (CT) scans, facilitating comparison of the position and shape of the stent frames between consecutive follow-up scans. Displacement of the proximal and distal ends of the stent frames, the entire stent frame trajectories, as well as changes in distance between the stent frames were determined for 6 patients with >5-mm displacement and 6 patients with <5-mm displacement at 1-year follow-up. The measurements were performed by 2 independent observers; the intraclass correlation coefficient (ICC) was used to determine interobserver variability. RESULTS: Three types of displacement were identified: displacement of the proximal and/or distal end of the stent frames, lateral displacement of one or both stent frames, and stent frame buckling. The ICC ranged from good (0.750) to excellent (0.958). No endoleak or migration was detected in the 12 patients on conventional CT angiography at 1 year. However, of the 6 patients with >5-mm displacement on the 1-year CT as determined by the new methodology, 2 went on to develop a type Ia endoleak in longer follow-up, and displacement progressed to >15 mm for 2 other patients. No endoleak or progressive displacement was appreciated for the patients with <5-mm displacement. CONCLUSION: The sac anchoring principle of the Nellix endosystem may result in several types of displacement that have not been observed during surveillance of regular endovascular aneurysm repairs. The presented methodology allows precise 3D determination of the Nellix endosystems and can detect subtle displacement better than standard CT angiography. Displacement >5 mm on the 1-year CT scans reconstructed with the new methodology may forecast impaired sealing and anchoring of the Nellix endosystem.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/etiologia , Humanos , Imageamento Tridimensional , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
4.
J Antimicrob Chemother ; 72(3): 923-932, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-27999033

RESUMO

Objectives: To define appropriate antibiotic use in hospitalized adults treated for a bacterial infection, we previously developed and validated a set of six generic quality indicators (QIs) covering all steps in the process of antibiotic use. We assessed the association between appropriate antibiotic use, defined by these QIs, and length of hospital stay (LOS). Methods: An observational multicentre study in 22 hospitals in the Netherlands included 1890 adult, non-ICU patients using antibiotics for a suspected bacterial infection. Performance scores were calculated for all QIs separately (appropriate or not), and a sum score described performance on the total set of QIs. We divided the sum scores into two groups: low (0%-49%) versus high (50%-100%). Multilevel analyses, correcting for confounders, were used to correlate QI performance (single and combined) with (log-transformed) LOS and in-hospital mortality. Results: The only single QI associated with shorter LOS was appropriate intravenous-oral switch (geometric means 6.5 versus 11.2 days; P < 0.001). A high sum score was associated with a shorter LOS in the total group (10.1 versus 11.2 days; P = 0.002) and in the subgroup of community-acquired infections (9.7 versus 10.9 days; P = 0.007), but not in the subgroup of hospital-acquired infections. We found no association between performance on QIs and in-hospital mortality or readmission rate. Conclusions: Appropriate antibiotic use, defined by validated process QIs, in hospitalized adult patients with a suspected bacterial infection appears to be associated with a shorter LOS and therefore positively contributes to patient outcome and healthcare costs.


Assuntos
Antibacterianos/uso terapêutico , Infecções Bacterianas/tratamento farmacológico , Tempo de Internação , Adulto , Idoso , Antibacterianos/efeitos adversos , Infecções Bacterianas/microbiologia , Infecções Comunitárias Adquiridas/tratamento farmacológico , Feminino , Custos de Cuidados de Saúde , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Indicadores de Qualidade em Assistência à Saúde
5.
Vascular ; 25(3): 234-241, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27565511

RESUMO

Objectives Endovascular treatment of pararenal abdominal aortic aneurysm has gained terrain over the past decade, despite the substantial need for reinterventions during follow-up. However, open repair is still a well-established treatment option. With the current study we report the results of a consecutive series of elective primary open pararenal abdominal aortic aneurysm repair in a tertiary vascular referral centre, combined with an overview of current literature and pooled data analysis of perioperative mortality of open and endovascular pararenal abdominal aortic aneurysm repair. Methods A retrospective analysis of a prospective database of all elective open pararenal abdominal aortic aneurysm repairs in the St. Antonius Hospital between 2005 and 2014 was performed. Primary endpoint was 30-day mortality. Secondary endpoints were 30-day morbidity, new onset dialysis, reintervention free survival, and overall survival during follow-up. Results Between 2005 and 2014, 214 consecutive patients underwent elective open pararenal abdominal aortic aneurysm repair. Mean age was 69.8 (±7.1) years, 82.7% (177/214) were men, and mean abdominal aortic aneurysm diameter was 62 (±11) mm. Thirty-day mortality was 3.4%. Thirty-day morbidity was 27.1%, which predominantly consisted of pneumonia (18.7% (40/214)), cardiac events (3.3% (7/214)), and new onset dialysis (2.8% (6/214)). Estimated five-year overall survival rate was 74.2%. 0.9% (2/214) of patients required abdominal aortic aneurysm-related reintervention, and an additional 2.3% (5/214) required surgical repair of an incisional hernia. Pooled analysis of literature revealed a 30-day mortality of 3.0% for open pararenal repair and 1.9% for fenestrated endovascular repair. Conclusion Open pararenal abdominal aortic aneurysm repair in the era of increasing endovascular options results in acceptable perioperative morbidity and mortality rates. Mid-term reintervention rate is low compared to fenestrated endovascular aneurysm repair. Expertise with open repair still remains essential for treatment of pararenal abdominal aortic aneurysms in the near future, especially for those patients that are declined for endovascular treatment.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Intervalo Livre de Doença , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
7.
Vascular ; 24(5): 492-500, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26503733

RESUMO

This study examines the application of near-infrared spectroscopy to noninvasively detect critical limb ischemia using regional hemoglobin oxygen saturation in percentage values and regional hemoglobin oxygen saturation limb-to-arm ratios. The regional hemoglobin oxygen saturation values and regional hemoglobin oxygen saturation limb-to-arm ratios were calculated in 61 patients with critical limb ischemia (group A). Measurements were performed in rest at four fixed spots at the most affected lower limb and at a reference spot at both upper arms. Similar measurements were performed in the left lower limb of 30 age-matched control patients without peripheral arterial disease (group B). The regional hemoglobin oxygen saturation values and regional hemoglobin oxygen saturation limb-to-arm ratios were significantly different at all measured spots between the groups (all p < 0.001), except for the regional hemoglobin oxygen saturation limb-to-arm ratios of the distal vastus lateralis (p = 0.056). However, a broad overlap of individual regional hemoglobin oxygen saturation values and regional hemoglobin oxygen saturation limb-to-arm ratios was found in both groups, which resulted in poor discriminative predictive value of single measurements. Single measurements of regional hemoglobin oxygen saturation values and regional hemoglobin oxygen saturation limb-to-arm ratios at all measured spots have poor discriminative predictive value in detection of critical limb ischemia. Measurement of regional hemoglobin oxygen saturation values and regional hemoglobin oxygen saturation limb-to-arm ratios at any of the measurement spots has no added value in detecting lower limb ischemia in individuals compared with current diagnostic modalities.


Assuntos
Isquemia/diagnóstico , Extremidade Inferior/irrigação sanguínea , Oxiemoglobinas/análise , Doença Arterial Periférica/diagnóstico , Espectroscopia de Luz Próxima ao Infravermelho , Extremidade Superior/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Área Sob a Curva , Biomarcadores/sangue , Estudos de Casos e Controles , Estado Terminal , Feminino , Humanos , Isquemia/sangue , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/sangue , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Fluxo Sanguíneo Regional
8.
Vascular ; 24(4): 425-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27235389

RESUMO

PURPOSE: To describe an off-the-shelf method for the treatment of abdominal aortic aneurysms with hostile (large, >30 mm) neck and/or small (<20 mm) aortic bifurcation. CASE REPORT: We describe five patients with large aortic necks and/or small aortic bifurcations, which were treated by combining an AFX endoprosthesis with a Valiant Captiva endograft, and additional proximal endoanchors when deemed necessary. Initial technical success was 100%. Follow-up ranged from 228 to 875 days. One patient suffered a type 1A and 1B endoleak at 446 days follow-up, which were successfully treated by endovascular means. CONCLUSION: Combining the AFX and Valiant Captiva endografts is an off-the-shelf solution for treatment of large diameter aortic necks and small aortic bifurcations in patients deemed unfit for open repair or declined for fenestrated endografts. Longer follow-up is required to assess the long-term safety with special focus on aortic neck dilation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
9.
Vascular ; 23(2): 179-82, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24821681

RESUMO

Intravenous thrombolysis with recombinant tissue plasminogen activator is currently the standard therapy for acute ischaemic stroke when started within 4.5 h of symptom onset. Systemic thrombolytic therapy can, however, lead to potentially lethal bleeding complications and is contra-indicated in several circumstances. Intra-arterial thrombolysis and/or intra-arterial thrombectomy can overcome these drawbacks and even increase the rate of recanalization. While intravenous thrombolysis is a relatively non-complex treatment, intra-arterial therapy in acute ischaemic stroke patients requires a dedicated intervention team which has to be available at all times. In this case report, we describe the multidisciplinary approach of a rare complication of a trapped mechanical thrombectomy device.


Assuntos
Acidente Vascular Cerebral/terapia , Trombectomia/instrumentação , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/uso terapêutico , Idoso , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/cirurgia , Fibrinolíticos/uso terapêutico , Humanos , Masculino , Terapia Trombolítica/instrumentação , Terapia Trombolítica/métodos
10.
J Cardiovasc Surg (Torino) ; 64(2): 159-166, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36897206

RESUMO

BACKGROUND: Literature is scarce on the course of iliac endograft limb apposition after endovascular aortic aneurysm repair (EVAR), which is why this study was conducted. METHODS: A retrospective observational imaging study was performed to measure iliac apposition of endograft limbs on the first post-EVAR computed tomography angiography (CTA) scan and on the latest available follow-up CTA scan. With center lumen line reconstructions and CT-applied dedicated software, the shortest apposition length (SAL) of the endograft limbs was assessed as well as the distance between the end of the fabric and the proximal border of the internal iliac artery or the endograft-internal artery distance (EID). RESULTS: Ninety-two iliac endograft limbs were eligible for measurements, with a median follow-up of 3.3 years. At the first post-EVAR CTA, the mean SAL was 31.9±15.6 mm, and the mean EID was 19.5±11.8. At the last follow-up CTA, there was a significant decrease in apposition of 10.5±14.1 mm (P<0.001) and a significant increase in EID of 5.3±9.5 mm (P<0.001). A type Ib endoleak developed in three patients due to a reduced SAL. The apposition was <10 mm in 24% of limbs at the last follow-up vs. 3% at the first post-EVAR CTA. CONCLUSIONS: This retrospective study documented a significant decrease in post-EVAR iliac apposition over time, partly due to retraction of iliac endograft limbs at mid-term CTA follow-up. Further research is required to identify whether regular determination of iliac apposition may predict and prevent type IB endoleaks.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
11.
BMC Urol ; 12: 25, 2012 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-22954383

RESUMO

BACKGROUND: Although indwelling urethra catheterization is a medical intervention with well-defined risks, studies show that approximately 14-38% of the indwelling urethra catheters (IUCs) are placed without a specific medical indication. In this paper we describe the prevalence of IUCs, including their inappropriate use in the Netherlands. We also determine factors associated with inappropriate use of IUCs in hospitalized patients. METHODS: In 28 Dutch hospitals, prevalence surveys were performed biannually in 2009 and 2010 within the PREZIES-network. All patients admitted to a participating hospital and who had an IUC in place at the day of the survey were included. Pre-determined criteria were used to categorize the indication for catheterization as appropriate or inappropriate. RESULTS: A total of 14,252 patients was included and 3020 (21.2%) of them had an IUC (range hospitals 13.4-27.3). Initial catheter placement was inappropriate in 5.2% of patients and 7.5% patients had an inappropriate indication at the day of the survey. In multivariate analyses inappropriate catheter use at the time of placement was associated with female sex, older age, admission on a non-intensive care ward, and not having had surgery. Inappropriate catheter use at the time of survey showed comparable associated factors. CONCLUSIONS: Although lower than in many other countries, inappropriate use of IUC is present in Dutch hospitals. To reduce the inappropriate use of IUCs, recommended components of care (bundle for UTI), including daily revision and registration of the indication for catheterization, should be introduced for all patients with an IUC. Additionally, an education and awareness campaign about appropriate indications for IUC should be available.


Assuntos
Cateteres de Demora/estatística & dados numéricos , Hospitalização , Cateterismo Urinário/estatística & dados numéricos , Idoso , Cateteres de Demora/efeitos adversos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prevalência , Cateterismo Urinário/efeitos adversos , Infecções Urinárias/epidemiologia , Infecções Urinárias/prevenção & controle
12.
J Vasc Surg ; 53(2): 293-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21055897

RESUMO

BACKGROUND: Since the introduction of endovascular aneurysm repair (EVAR), long-term follow-up studies reporting single-device results are scarce. In this study, we focus on EVAR repair with the Talent stent graft (Medtronic, Santa Rosa, Calif). METHODS: Between July 2000 and December 2007, 365 patients underwent elective EVAR with a Talent device. Patient data were gathered prospectively and evaluated retrospectively. By American Society of Anesthesiologists category, 74% were categories III and IV. Postoperative computed tomography (CT) scanning was performed before discharge, at 3, 12 months, and yearly thereafter. Data are presented according to reporting standards for EVAR. RESULTS: The mean proximal aortic neck diameter was 27 mm (range, 16-36 mm), with a neck length <15 mm in 31% (data available for 193 patients). Deployment of endografts was successful in 361 of 365 patients (99%). Initially, conversion to laparotomy was necessary in four patients. Primary technical success determined by results from computed tomography (CT) scans before discharge was achieved in 333 patients (91%). Proximal type I endoleaks were present in 28 patients (8%) during follow-up, and 14 of these patients needed additional treatment for type I endoleak. The 30-day mortality for the whole Talent group was 1.1% (4 of 365). Follow-up to 84 months is reported for 24 patients. During follow-up, 122 (33%) patients died; in nine, death was abdominal aortic aneurysm (AAA)-related (including 30-day mortality). Kaplan-Meier estimates revealed primary clinical success rates of 98% at 1 year, 93% at 2 years, 88% at 3 years, 79% at 4 years, 64% at 5 years, 51% at 6 years, and 48% at 7 years. Secondary interventions were performed in 73 of 365 patients (20%). Ten conversions for failed endografts were performed. Life-table yearly risk for AAA-related reintervention was 6%, yearly risk for conversion to open repair was 1.1%, yearly risk for total mortality was 8.9%, and yearly risk for AAA-related mortality was 0.8%. CONCLUSION: Initially, technical success of endovascular aneurysm repair (EVAR) using the Talent endograft is high, with acceptable yearly risk for AAA-related mortality and conversion. However, a substantial amount of mainly endovascular reinterventions is necessary during long-term follow-up to achieve these results.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , California , Distribuição de Qui-Quadrado , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Humanos , Estimativa de Kaplan-Meier , Tábuas de Vida , Modelos Logísticos , Pessoa de Meia-Idade , Países Baixos , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Crit Care ; 15(2): R111, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21481251

RESUMO

INTRODUCTION: A semi-upright position in ventilated patients is recommended to prevent ventilator-associated pneumonia (VAP) and is one of the components in the Ventilator Bundle of the Institute for Health Care Improvement. This recommendation, however, is not an evidence-based one. METHODS: A systematic review on the benefits and disadvantages of semi-upright position in ventilated patients was done according to PRISMA guidelines. Then a European expert panel developed a recommendation based on the results of the systematic review and considerations beyond the scientific evidence in a three-round electronic Delphi procedure. RESULTS: Three trials (337 patients) were included in the review. The results showed that it was uncertain whether a 45° bed head elevation was effective or harmful with regard to the occurrence of clinically suspected VAP, microbiologically confirmed VAP, decubitus and mortality, and that it was unknown whether 45° elevation for 24 hours a day increased the risk for thromboembolism or hemodynamic instability. A group of 22 experts recommended elevating the head of the bed of mechanically ventilated patients to a 20 to 45° position and preferably to a ≥ 30° position as long as it does not pose risks or conflicts with other nursing tasks, medical interventions or patients' wishes. CONCLUSIONS: Although the review failed to prove clinical benefits of bed head elevation, experts prefer this position in ventilated patients. They made clear that the position of a ventilated patient in bed depended on many determinants. Therefore, given the scientific uncertainty about the benefits and harms of a semi-upright position, this position could only be recommended as the preferred position with the necessary restrictions.


Assuntos
Leitos , Posicionamento do Paciente , Respiração Artificial , Medicina Baseada em Evidências , Humanos , Posicionamento do Paciente/métodos , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
BMC Urol ; 11: 10, 2011 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-21605403

RESUMO

BACKGROUND: Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. METHODS: The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. RESULTS: Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13) and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13), decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96), but increased significantly in intensive care (IC) and coronary care (CC) units (OR 1.48; 95% CI 1.01 - 2.17). The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16) and neurology (ratio 0.97; 95% CI 0.80 - 1.18) and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96) and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90). The percentage of correct indications on the day of inclusion increased from 50 to 67% (p < 0.0001). The prevalence of urinary tract infections in catheterized patients did not change. The mean cost saved per 100 patients was € 537. CONCLUSION: Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or where catheterization is prolonged, can expect important improvements.


Assuntos
Fidelidade a Diretrizes/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Cateterismo Urinário/estatística & dados numéricos , Cateterismo Urinário/normas , Infecções Urinárias/epidemiologia , Infecções Urinárias/prevenção & controle , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Medição de Risco , Fatores de Risco , Revisão da Utilização de Recursos de Saúde , Adulto Jovem
15.
J Cardiovasc Surg (Torino) ; 62(6): 600-608, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34520136

RESUMO

BACKGROUND: Sufficient apposition and oversizing of the endograft in the aortic neck are both essential for durable endovascular aneurysm repair (EVAR). These measures are however not regularly stated on post-EVAR computed tomography angiography (CTA) scan reports. In this study endograft apposition and neck enlargement (NE) after EVAR with an Endurant II(s) endograft were analyzed and associated with supra- and infrarenal aortic neck morphology. METHODS: In 97 consecutive elective patients, the aortic neck morphology was measured on the pre-EVAR CTA scan on a 3mensio vascular workstation. The distance between the lowest renal artery and the proximal edge of the fabric (shortest fabric distance, SFD), and the shortest length of circumferential apposition between endograft and aortic wall (shortest apposition length, SAL) were determined on the early post-EVAR CTA scan. NE, defined as the aortic diameter change between pre- and post-EVAR CTA scan, was determined at eight levels: +40, +30, +20, +15, +10, 0, -5 and -10 mm relative to the lowest renal artery baseline. The aortic neck diameter and preoperative oversizing were correlated to NE with the Pearson correlation coefficient. The effective post-EVAR endograft oversizing is calculated from the nominal endograft diameter and the post-EVAR neck diameter where the endograft is circumferentially apposed. RESULTS: The median time (interquartile range, IQR) between the EVAR procedure and the pre- and post-EVAR CTA scan was 40 (25, 71) days and 36 (30, 46) days, respectively. The Endurant II(s) endograft was deployed with a median (IQR) SFD of 1.0 (0.0, 3.0) mm. The SAL was <10 mm in 9% of patients and significantly influenced by the pre-EVAR aortic neck length (P=0.001), hostile neck shape (P=0.017), and maximum curvature at the suprarenal aorta (P=0.039). The median (interquartile range) SAL was 21.0 (15.0, 27.0) mm with a median (IQR) pre-EVAR infrarenal neck length of 23.5 (13.0, 34.8) mm. The median (IQR) difference between the SAL and neck length was -5.0 (-12.0, 2.8) mm. Significant (P<0.001) NE of 1.7 (0.9, 2.5) mm was observed 5 mm below the renal artery baseline, which resulted in an effective post-EVAR endograft oversizing <10% in 43% of the patients. No correlation was found between NE and aortic neck diameter or preoperative oversizing. CONCLUSIONS: Circumferential apposition between an endograft and the infrarenal aortic neck, SAL, and NE can be derived from standard postoperative CT scans. These variables provide essential information about the post-procedural endograft and aortic neck morphology regardless of the preoperative measurements. Patients with SAL<10 mm or effective oversizing <10% due to NE may benefit from intensified follow-up, but clinical consequences of SAL and NE should be evaluated in future longitudinal studies with longer term follow-up.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Humanos , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
J Vasc Surg Cases Innov Tech ; 6(3): 454-459, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32835150

RESUMO

The coronavirus disease 2019 (COVID-19), a viral respiratory illness caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been described to predispose to thrombotic disease in both the venous and arterial circulations. We report four cases of an acute arterial occlusion in COVID-19 patients and literature review on the occurrence of arterial thrombosis in patients with COVID-19. Our findings demonstrate that physicians should be vigilant for signs of thrombotic complications in both hospitalized and new COVID-19 patients.

17.
J Vasc Surg ; 49(1): 214-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19174257

RESUMO

We report the case of a 71-year-old man with acute back and left flank pain caused by a large pseudoaneurysm of the left renal artery. The pseudoaneurysm resulted from a complete fracture of a stent that had been placed at the origin of this vessel 10 months earlier. Because the left kidney had no residual function, the patient was treated by percutaneous occlusion of the left renal artery with a vascular plug. The symptoms rapidly subsided, and he remained symptom free at the 6-month follow-up. Stent fractures, their complications, and management are discussed.


Assuntos
Falso Aneurisma/etiologia , Angioplastia com Balão/efeitos adversos , Falha de Prótese , Obstrução da Artéria Renal/terapia , Artéria Renal , Stents , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Angiografia Digital , Angioplastia com Balão/instrumentação , Cateterismo/instrumentação , Desenho de Equipamento , Humanos , Masculino , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Ned Tijdschr Geneeskd ; 1632019 02 01.
Artigo em Holandês | MEDLINE | ID: mdl-30730689

RESUMO

BACKGROUND: Peripheral arterial disease is a common condition in elderly patients. Cases of severe peripheral vascular disease can be treated with endovascular revascularization or bypass surgery. An amputation may be necessary if revascularization treatments fail. CASE DESCRIPTION: A 94-year-old woman with dementia, living in a nursing home, was referred to the vascular surgery team for a painful ulcer on the left foot. Revascularization fails and due to the infectious status, an above-the-knee amputation seems necessary. Family and physicians, however, opt for a conservative, palliative policy and in the next few weeks the infectious ulcer develops into mummification. The patient nonetheless experiences a good quality of life until she becomes bedridden because of pneumonia. She dies 11 months after she was diagnosed with critical limb ischaemia. CONCLUSION: Adopting a conservative approach in elderly patients with severe peripheral arterial disease and dementia is a worthwhile alternative to amputation, and can achieve a reasonably good quality of life. Diaries maintained by family members can provide insight into the patient's quality of life.


Assuntos
Tratamento Conservador , Úlcera do Pé/fisiopatologia , Isquemia/fisiopatologia , Doença Arterial Periférica/fisiopatologia , Fatores Etários , Idoso de 80 Anos ou mais , Evolução Fatal , Feminino , Úlcera do Pé/terapia , Humanos , Isquemia/diagnóstico , Isquemia/terapia , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Qualidade de Vida
19.
Trauma Surg Acute Care Open ; 4(1): e000272, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30899798

RESUMO

BACKGROUND: Necrotizing fasciitis is a potentially lethal condition for which early and adequate treatment with surgical debridement and broad-spectrum intravenous antibiotics are essential for survival. It is hypothesized that Group A Streptococcus (GAS) necrotizing fasciitis causes exhaustion of the immune system, making these patients more susceptible for late secondary infections. METHODS: A retrospective study was conducted of all patients with necrotizing fasciitis between 2002 and 2016. Patients with necrotizing fasciitis based on macroscopic findings, positive Gram staining, culture or fresh frozen section of fascia biopsies were included. Patients with necrotizing fasciitis were divided into two groups based on the presence of GAS. Of both groups, clinical course, outcome and occurrence of late secondary infections were analyzed. For the occurrence of secondary infections, pneumonia was chosen as reference for late secondary infections. RESULTS: Eighty-one patients with necrotizing fasciitis were included of which 38 (47%) had GAS necrotizing fasciitis and 43 (53%) had non-GAS necrotizing fasciitis. Patients with GAS necrotizing fasciitis were younger (50 vs. 61 years, p=0.023) and more often classified as ASA I (45% vs. 14%, p=0.002) compared with patients with non-GAS necrotizing fasciitis. In-hospital mortality rate for necrotizing fasciitis was 32%. Patients with comorbidities were more likely to die of necrotizing fasciitis compared with patients without comorbidities (OR 7.41, 95% CI 1.58 to 34.63). Twelve patients (39%) with GAS necrotizing fasciitis developed pneumonia compared with four patients (13%) with non-GAS necrotizing fasciitis (p=0.017; OR 4.42, 95% CI 1.124 to 15.79). Median time from diagnosis to development of pneumonia in patients with GAS necrotizing fasciitis was 10 days (IQR 9). CONCLUSION: Patients with GAS necrotizing fasciitis have an increased risk to develop late secondary infections during initial treatment for necrotizing fasciitis compared with patients with necrotizing fasciitis without involvement of GAS. This suggests exhaustion of the immune system after severe GAS infection. LEVEL OF EVIDENCE: III.

20.
PLoS One ; 14(6): e0218372, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31220122

RESUMO

Seven hospitals participated in the Dutch national surveillance for ventilator-associated pneumonia (VAP) and its risk factors. We analysed time-independent and time-dependent risk factors for VAP using the standard Cox regression and the flexible Weighted Cumulative Effects method (WCE) that evaluates both current and past exposures. The prospective surveillance of intensive care patients aged ≥16 years and ventilated ≥48 hours resulted in the inclusion of 940 primary ventilation periods, comprising 7872 ventilation days. The average VAP incidence density was 10.3/1000 ventilation days. Independent risk factors were age (16-40 years at increased risk: HR 2.42 95% confidence interval 1.07-5.50), COPD (HR 0.19 [0.04-0.78]), current sedation score (higher scores at increased risk), current selective oropharyngeal decontamination (HR 0.19 [0.04-0.91]), jet nebulizer (WCE, decreased risk), intravenous antibiotics for selective decontamination of the digestive tract (ivSDD, WCE, decreased risk), and intravenous antibiotics not for SDD (WCE, decreased risk). The protective effect of ivSDD was afforded for 24 days with a delay of 3 days. For some time-dependent variables, the WCE model was preferable over standard Cox proportional hazard regression. The WCE method can furthermore increase insight into the active time frame and possible delay herein of a time-dependent risk factor.


Assuntos
Antibacterianos/uso terapêutico , Infecção Hospitalar/epidemiologia , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Adolescente , Idoso , Infecção Hospitalar/etiologia , Feminino , Trato Gastrointestinal/efeitos dos fármacos , Trato Gastrointestinal/patologia , Humanos , Inalação , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Pneumonia Associada à Ventilação Mecânica/tratamento farmacológico , Pneumonia Associada à Ventilação Mecânica/patologia , Modelos de Riscos Proporcionais , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/patologia , Respiração Artificial/efeitos adversos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA