Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-31995682

RESUMO

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Nível de Saúde , Humanos , Incidência , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
2.
Curr Cardiol Rep ; 25(3): 97-107, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36680732

RESUMO

PURPOSE OF REVIEW: Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS: A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Imagem Multimodal
3.
N Engl J Med ; 380(18): 1695-1705, 2019 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-30883058

RESUMO

BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/etiologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
4.
Echocardiography ; 39(10): 1348-1358, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36198094

RESUMO

INTRODUCTION: Gram-negative organisms of the AACEK group, formerly known as HACEK, rarely cause endocarditis. CASE SERIES: We present three cases of bacterial endocarditis, involving native and prosthetic valves, caused by AACEK organisms. In two patients, Cardiobacterium hominis was the responsible organism, and in a third, Aggregatibacter aphrophilus was implicated. A dental source of infection was identified in two patients, and in all three patients, the presentation of endocarditis was subacute. DISCUSSION: This case series highlights the indolent nature of infection with the AACEK organisms. It also demonstrates the crucial role of multimodality imaging, especially transesophageal echocardiography, in the diagnosis of AACEk endocarditis of both native and prosthetic valves, and in delineating the extent of abscess in those with prosthetic valve infection.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/diagnóstico por imagem , Ecocardiografia Transesofagiana
5.
Circulation ; 141(19): 1527-1537, 2020 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-32272848

RESUMO

BACKGROUND: This study aimed to compare echocardiographic findings in low-risk patients with severe aortic stenosis after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHODS: The PARTNER 3 trial (Placement of Aortic Transcatheter Valves) randomized 1000 patients with severe aortic stenosis and low surgical risk to undergo either transfemoral TAVR with the balloon-expandable SAPIEN 3 valve or SAVR. Transthoracic echocardiograms obtained at baseline and at 30 days and 1 year after the procedure were analyzed by a consortium of 2 echocardiography core laboratories. RESULTS: The percentage of moderate or severe aortic regurgitation (AR) was low and not statistically different between the TAVR and SAVR groups at 30 days (0.8% versus 0.2%; P=0.38). Mild AR was more frequent after TAVR than SAVR at 30 days (28.8% versus 4.2%; P<0.001). At 1 year, mean transvalvular gradient (13.7±5.6 versus 11.6±5.0 mm Hg; P=0.12) and aortic valve area (1.72±0.37 versus 1.76±0.42 cm2; P=0.12) were similar in TAVR and SAVR. The percentage of severe prosthesis-patient mismatch at 30 days was low and similar between TAVR and SAVR (4.6 versus 6.3%; P=0.30). Valvulo-arterial impedance (Zva), which reflects total left ventricular hemodynamic burden, was lower with TAVR than SAVR at 1 year (3.7±0.8 versus 3.9±0.9 mm Hg/mL/m2; P<0.001). Tricuspid annulus plane systolic excursion decreased and the percentage of moderate or severe tricuspid regurgitation increased from baseline to 1 year in SAVR but remained unchanged in TAVR. Irrespective of treatment arm, high Zva and low tricuspid annulus plane systolic excursion, but not moderate to severe AR or severe prosthesis-patient mismatch, were associated with increased risk of the composite end point of mortality, stroke, and rehospitalization at 1 year. CONCLUSIONS: In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Zva and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , América do Norte , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Circulation ; 140(16): 1296-1305, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31476897

RESUMO

BACKGROUND: For patients with severe aortic stenosis and coronary artery disease, the completely percutaneous approach to aortic valve replacement and revascularization has not been compared with the standard surgical approach. METHODS: The prospective SURTAVI trial (Safety and Efficiency Study of the Medtronic CoreValve System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement) enrolled intermediate-risk patients with severe aortic stenosis from 87 centers in the United States, Canada, and Europe between June 2012 and June 2016. Complex coronary artery disease with SYNTAX score (Synergy Between PCI with Taxus and Cardiac Surgery Trial) >22 was an exclusion criterion. Patients were stratified according to the need for revascularization and then randomly assigned to treatment with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). Patients assigned to revascularization in the TAVR group underwent percutaneous coronary intervention, whereas those in the SAVR group had coronary artery bypass grafting. The primary end point was the rate of all-cause mortality or disabling stroke at 2 years. RESULTS: Of 1660 subjects with attempted aortic valve implants, 332 (20%) were assigned to revascularization. They had a higher Society of Thoracic Surgeons risk score for mortality (4.8±1.7% versus 4.4±1.5%; P<0.01) and were more likely to be male (65.1% versus 54.2%; P<0.01) than the 1328 patients not assigned to revascularization. After randomization to treatment, there were 169 patients undergoing TAVR and percutaneous coronary intervention, 163 patients undergoing SAVR and coronary artery bypass grafting, 695 patients undergoing TAVR, and 633 patients undergoing SAVR. No significant difference in the rate of the primary end point was found between TAVR and percutaneous coronary intervention and SAVR and coronary artery bypass grafting (16.0%; 95% CI, 11.1-22.9 versus 14.0%; 95% CI, 9.2-21.1; P=0.62), or between TAVR and SAVR (11.9%; 95% CI, 9.5-14.7 versus 12.3%; 95% CI, 9.8-15.4; P=0.76). CONCLUSIONS: For patients at intermediate surgical risk with severe aortic stenosis and noncomplex coronary artery disease (SYNTAX score ≤22), a complete percutaneous approach of TAVR and percutaneous coronary intervention is a reasonable alternative to SAVR and coronary artery bypass grafting. CLINICAL TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov. Unique identifier: NCT01586910.

7.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-27040324

RESUMO

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Ultrassonografia
8.
Catheter Cardiovasc Interv ; 94(6): 812-817, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31062487

RESUMO

BACKGROUND: Thrombocytopenia after transcatheter aortic valve replacement (TAVR) is associated with adverse clinical outcomes. Whether preprocedural P2Y12 inhibition prevents postprocedural thrombocytopenia is uncertain. METHODS: This retrospective analysis identified consecutive patients (n = 266) undergoing TAVR between November 2016 and July 2017. Preprocedure clopidogrel load ≥300 mg or maintenance P2Y12 inhibitor therapy defined preprocedural P2Y12 inhibition. Patients who did not consent for the registry (n = 8), with baseline severe thrombocytopenia (<90 × 103 platelets/µL; n = 14), or without baseline platelet count (n = 4) were excluded. The primary outcome was proportion of patients who developed >20% decrease in platelet count from baseline to day 1 post-TAVR. RESULTS: Patients with (n = 134) versus without (n = 106) preprocedural P2Y12 inhibition had no differences in platelet count at baseline. Patients with preprocedural P2Y12 inhibition had a significantly lower proportion of the primary outcome (34.3% vs. 57.5%, p = .001) and a lower absolute decrease in platelet count (32.8 × 103 vs. 45.8 × 103 platelet/µL, p = .01). Of patients without baseline thrombocytopenia (n = 198), a numerically lower rate of patients with versus without preprocedural P2Y12 inhibition developed thrombocytopenia on day 1 post-TAVR (25.5% vs. 36.4%, p = .1). CONCLUSION: Patients who received preprocedural P2Y12 inhibition prior to TAVR were less likely to demonstrate a decrease in platelet count after TAVR. Prospective studies to further understand the clinical implication of these findings are warranted.


Assuntos
Plaquetas/efeitos dos fármacos , Clopidogrel/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Receptores Purinérgicos P2Y12/efeitos dos fármacos , Trombocitopenia/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Plaquetas/metabolismo , Clopidogrel/efeitos adversos , Feminino , Humanos , Masculino , Contagem de Plaquetas , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Receptores Purinérgicos P2Y12/sangue , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Trombocitopenia/etiologia , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 42(10): 1347-1354, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31429947

RESUMO

INTRODUCTION: A common complication of transcatheter aortic valve repair (TAVR) is development of conduction defects requiring pacemaker (PPM) implantation. These defects are not universally permanent. OBJECTIVE: To determine the incidence and predictors of persistent device dependency in patients with PPM implantation following TAVR with a self-expanding prosthesis. METHODS: Records of patients who underwent post-TAVR PPM implantation were reviewed. Patients with persistent complete AV block (AVBIII) one month post-TAVR were compared to those regaining conduction. RESULTS: Between September 2014 and March 2017, 485 patients underwent TAVR with a self-expanding prosthesis; 77 (15.9%) underwent PPM implantation for AVBIII. Device interrogation at one month was available for 61 patients (79%): 22 (36.1%) had resolution of AVBIII while 39 (63.9%) remained pacemaker-dependent. Pre-TAVR right bundle branch block was more frequent in device-dependent patients (19 of 38, 50% vs 4 of 22, 18%; RR 2.75; P = .01). Device-dependence was associated with AVBIII as the first postprocedural rhythm (37 of 39, 95% vs 12 of 22, 55%; RR 1.74; P < .0001), earlier implantation (median 1d, IQR: 0-1.5d vs 2d, IQR: 1.0-4.0d, P = .0004), and a shorter duration of hospitalization (median 3d, IQR: 2-3.5d vs 4d, IQR: 2-5.75d, P = .03). Pacemaker dependence was also associated with a higher prosthesis-to left ventricular outflow tract (LVOT) diameter (1.45 ± 0.11 vs 1.39 ± 0.07; P = .02) and the lack of prior aortic valvuloplasty (5 of 39, 13% vs 8 of 22, 36%; RR 0.35; P = .03). CONCLUSIONS: In patients receiving a PPM following self-expanding TAVR, a long-term pacing requirement can be predicted from the timing of AV block, existing conduction-system disease, larger prosthesis-to-LVOT diameter, and the lack of aortic valvuloplasty.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Prótese Vascular , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de Risco
10.
Echocardiography ; 36(8): 1586-1589, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31246314

RESUMO

A 51-year-old man with Klippel-Feil syndrome (KFS) and immunodeficiency syndrome, status postintravenous immunoglobulin therapy, presented with shortness of breath. He was found to have severe aortic regurgitation in the setting of a trileaflet aortic valve with thickened leaflets and mild prolapse of the right coronary cusp with left ventricular dilation and borderline left ventricular ejection fraction. Although various cardiac anomalies have been described in KPS, otherwise unexplained severe aortic regurgitation has not been previously reported to the best of our knowledge. The patient underwent an uncomplicated surgical aortic valve replacement with a 25-mm Medtronic Avalus pericardial tissue valve resulting in symptomatic improvement. Intra-operative management and transesophageal echocardiography can be particularly challenging in KFS patients. We describe the first reported case of severe aortic regurgitation in KPS, review the cardiac anomalies associated with the syndrome, and highlight the clinical challenges in intra-operative management of these patients.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Ecocardiografia Transesofagiana/métodos , Imageamento Tridimensional/métodos , Síndrome de Klippel-Feil/complicações , Imagem Multimodal , Tomografia Computadorizada por Raios X/métodos , Valva Aórtica , Insuficiência da Valva Aórtica/diagnóstico , Diagnóstico Diferencial , Humanos , Síndrome de Klippel-Feil/diagnóstico , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA