Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 226
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786511

RESUMO

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial
2.
Europace ; 25(2): 561-570, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36358001

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) has been shown to be effective and safe. Limited data are available on LBBAP in the congenital heart disease (CHD) population. This study aims to describe the feasibility and safety of LBBAP in CHD patients compared with non-CHD patients. METHODS AND RESULTS: This is a single-centre, non-randomized observational study recruiting consecutive patients with bradycardia indication. Demographic data, ECGs, imaging, and procedural data including lead parameters were recorded. A total of 39 patients were included: CHD group (n = 13) and non-CHD group (n = 26). Congenital heart disease patients were younger (55 ± 14.5 years vs. 73.2 ± 13.1, P < 0.001). Acute success was achieved in all CHD patients and 96% (25/26) of non-CHD patients. No complications were encountered in either group. The procedural time for CHD patients was comparable (96.4 ± 54 vs. 82.1 ± 37.9 min, P = 0.356). Sheath reshaping was required in 7 of 13 CHD patients but only in 1 of 26 non-CHD patients, reflecting the complex and distorted anatomy of the patients in this group. Lead parameters were similar in both groups; R wave (11 ± 7 mV vs. 11.5 ± 7.5, P = 0.881) and pacing threshold (0.6 ± 0.3 V vs. 0.7 ± 0.3, P = 0.392). Baseline QRS duration was longer in the CHD group (150 ± 28.2 vs. 118.6 ± 26.6 ms, P = 0.002). Despite a numerically greater reduction in QRS and a similar left ventricular activation time (65.9 ± 6.2 vs. 67 ± 16.8 ms, P = 0.840), the QRS remained longer in the CHD group (135.5 ± 22.4 vs. 106.9 ± 24.7 ms, P = 0.005). CONCLUSION: Left bundle branch area pacing is feasible and safe in CHD patients as compared to that in non-CHD patients. Procedural and fluoroscopy times did not differ between both groups. Lead parameters were satisfactory and stable over a short-term follow-up.


Assuntos
Fascículo Atrioventricular , Cardiopatias Congênitas , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/etiologia , Eletrocardiografia/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Resultado do Tratamento
3.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37523771

RESUMO

BACKGROUND: Leadless pacemakers (LPs) may mitigate the risk of lead failure and pocket infection related to conventional transvenous pacemakers. Atrial LPs are currently being investigated. However, the optimal and safest implant site is not known. OBJECTIVES: We aimed to evaluate the right atrial (RA) anatomy and the adjacent structures using complementary analytic models [gross anatomy, cardiac magnetic resonance imaging (MRI), and computer simulation], to identify the optimal safest location to implant an atrial LP human. METHODS AND RESULTS: Wall thickness and anatomic relationships of the RA were studied in 45 formalin-preserved human hearts. In vivo RA anatomy was assessed in 100 cardiac MRI scans. Finally, 3D collision modelling was undertaken assessing for mechanical device interaction. Three potential locations for an atrial LP were identified; the right atrial appendage (RAA) base, apex, and RA lateral wall. The RAA base had a wall thickness of 2.7 ± 1.6 mm, with a low incidence of collision in virtual implants. The anteromedial recess of the RAA apex had a wall thickness of only 1.3 ± 0.4 mm and minimal interaction in the collision modelling. The RA lateral wall thickness was 2.6 ± 0.9 mm but is in close proximity to the phrenic nerve and sinoatrial artery. CONCLUSIONS: Based on anatomical review and 3D modelling, the best compromise for an atrial LP implantation may be the RAA base (low incidence of collision, relatively thick myocardial tissue, and without proximity to relevant epicardial structures); the anteromedial recess of the RAA apex and lateral wall are alternate sites. The mid-RAA, RA/superior vena cava junction, and septum appear to be sub-optimal fixation locations.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Veia Cava Superior , Simulação por Computador , Lipopolissacarídeos , Estimulação Cardíaca Artificial/métodos , Átrios do Coração
4.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
5.
Eur Heart J ; 43(28): 2685-2694, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35673927

RESUMO

AIMS: To investigate the incidence of major adverse ventricular arrhythmias and related events (MAREs) and to develop a stratification tool predicting MAREs in adults with a systemic right ventricle (sRV). METHODS AND RESULTS: In a multicentre approach, all adults (≥16 years old) with a sRV undergoing follow-up between 2000 and 2018 were identified. The incidence of MAREs, defined as sudden cardiac death, sustained ventricular tachycardia, and appropriate implantable cardioverter-defibrillator (ICD) therapy, was analysed. The association of MAREs with clinical, electrical, and echocardiographic parameters was evaluated. A total of 1184 patients (median age 27.1 years; interquartile range 19.9-34.9 years; 59% male; 70% with atrial switch repair for D-transposition of the great arteries) were included. The incidence of MAREs was 6.3 per 1000 patient-years. On multivariate analysis, age, history of heart failure, syncope, QRS duration, severe sRV dysfunction and at least moderate left ventricular outflow tract obstruction were retained in the final model with a C-index of 0.78 [95% confidence interval (CI) 0.72-0.83] and a calibration slope of 0.93 (95% CI 0.64-1.21). For every five ICDs implanted in patients with a 5-year MARE risk >10%, one patient may potentially be spared from a MARE. CONCLUSION: Sudden cardiac death remains a devastating cause of death in a contemporary adult cohort with a sRV. A prediction model based on clinical, electrocardiographic, and echocardiographic parameters was devised to estimate MARE risk and to identify high-risk patients who may benefit from primary prevention ICD implantation.


Assuntos
Ventrículos do Coração , Transposição dos Grandes Vasos , Adolescente , Adulto , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Artérias , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Adulto Jovem
6.
Sex Transm Dis ; 49(5): 377-382, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35067598

RESUMO

BACKGROUND: The aims of this study was to describe molecular surveillance of Neisseria gonorrhoeae in the North Zone of Alberta (NZ) and to determine its value in predicting antimicrobial resistance. METHODS: Sequence types (STs) and single-nucleotide polymorphism (SNP) assays were performed on nucleic acid amplification testing (NAAT) samples. Sequence types of NAATs were matched to ST of cultures from across Alberta. Antimicrobial resistance prediction of NAATs for cephalosporins, azithromycin, and ciprofloxacin using SNP was compared with matching ST culture results using agar dilution and whole-genome sequencing. RESULTS: Of 2755 eligible specimens (2492 cases), 61.9% (1646 specimens) were sent for sequence typing, identifying 196 unique ST. Antimicrobial resistance data for 1307 additional cases were available using matching cultures. Decreased susceptibility (DS) to antimicrobials used for gonorrhea treatment was rare in the NZ; according to the SNP assay, none of the specimens had predicted DS to cephalosporins or azithromycin resistance. However, of the NZ NAAT samples tested in this study, 10.7% (131 of 1220) were predicted to have intermediate cephalosporin minimum inhibitory concentrations and 9.6% (115 of 1204) were resistant to ciprofloxacin. Based on cultures, the proportions of resistance in all of Alberta were as follows: DS to cephalosporins, 0.6% (20 of 3373); DS to intermediate cephalosporin, 16.9% (570 of 3373); azithromycin resistance, 1.2% (41 of 3373); and ciprofloxacin resistance, 32.2% (1087 of 3373). CONCLUSIONS: Our results highlight our ability to use culture-independent methods to predict antimicrobial resistance in N. gonorrhoeae.


Assuntos
Gonorreia , Neisseria gonorrhoeae , Alberta/epidemiologia , Antibacterianos/farmacologia , Azitromicina/farmacologia , Cefalosporinas/farmacologia , Ciprofloxacina/farmacologia , Farmacorresistência Bacteriana/genética , Gonorreia/tratamento farmacológico , Gonorreia/epidemiologia , Humanos , Testes de Sensibilidade Microbiana , Neisseria gonorrhoeae/genética
7.
Pacing Clin Electrophysiol ; 45(4): 481-490, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35043404

RESUMO

BACKGROUND: Conventional superior access for cardiac implantable electronic devices (CIEDs) is not always possible and femoral CIEDs (F-CIED) are an alternative option when leadless systems are not suitable. The long-term outcomes and extraction experiences with F-CIEDs, in particular complex F-CIED (ICD/CRT devices), remain poorly understood. METHODS: Patients referred for F-CIEDs implantation between 2002 and 2019 at two tertiary centers were included. Early complications were defined as ≤30 days following implant and late complications >30 days. RESULTS: Thirty-one patients (66% male; age 56 ± 20 years; 35% [11] patients with congenital heart disease) were implanted with F-CIEDs (10 ICD/CRT and 21 pacemakers). Early complications were observed in 6.5% of patients: two lead displacements. Late complications at 6.8 ± 4.4 years occurred in 29.0% of patients. This was higher with complex F-CIED compared to simple F-CIED (60.0% vs. 14.3%, p = .02). Late complications were predominantly generator site related (n = 8, 25.8%) including seven infections/erosions and one generator migration. Eight femoral generators and 14 leads (median duration in situ seven [range 6-11] years) were extracted without complication. CONCLUSIONS: Procedural success with F-CIEDs is high with clinically acceptable early complication rates. There is a notable risk of late complications, particularly involving the generator site of complex devices following repeat femoral procedures. Extraction of chronic F-CIED in experienced centers is feasible and safe.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Idoso , Eletrônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Emerg Infect Dis ; 27(6): 1718-1722, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34013864

RESUMO

We assessed antimicrobial resistance (AMR) in Neisseria gonorrhoeae in Nunavut, Canada, using remnant gonorrhea nucleic acid amplification test-positive urine specimens. This study confirms the feasibility of conducting N. gonorrhoeae AMR surveillance and highlights the diversity of gonococcal sequence types and geographic variation of AMR patterns in the territory.


Assuntos
Gonorreia , Neisseria gonorrhoeae , Antibacterianos/farmacologia , Canadá , Farmacorresistência Bacteriana , Gonorreia/tratamento farmacológico , Humanos , Inuíte , Testes de Sensibilidade Microbiana , Nunavut
9.
J Cardiovasc Electrophysiol ; 32(2): 376-388, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33368769

RESUMO

INTRODUCTION: Substrate-based catheter ablation approaches to ventricular tachycardia (VT) focus on low-voltage areas and abnormal electrograms. However, specific electrogram characteristics in sinus rhythm are not clearly defined and can be subject to variable interpretation. We analyzed the potential ablation target size using automatic abnormal electrogram detection and studied findings during substrate mapping in the VT isthmus area. METHODS AND RESULTS: Electrogram characteristics in 61 patients undergoing scar-related VT ablation using ultrahigh-density 3D-mapping with a 64-electrode mini-basket catheter were analyzed retrospectively. Forty-four complete substrate maps with a mean number of 10319 ± 889 points were acquired. Fractionated potentials detected by automated annotation and manual review were present in 43 ± 21% of the entire low-voltage area (<1.0 mV), highly fractionated potentials in 7 ± 8%, late potentials in 13 ± 15%, fractionated late potentials in 7 ± 9% and isolated late potentials in 2 ± 4%, respectively. Highly fractionated potentials (>10 ± 1 fractionations) were found in all isthmus areas of identified VT during substrate mapping, while isolated late potentials were distant from the critical isthmus area in 29%. CONCLUSION: The ablation target area varies enormously in size, depending on the definition of abnormal electrograms. Clear linking of abnormal electrograms with critical VT isthmus areas during substrate mapping remains difficult due to a lack of specificity rather than sensitivity. However, highly fractionated, low-voltage electrograms were found to be present in all critical VT isthmus sites.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Cicatriz/diagnóstico , Cicatriz/etiologia , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
10.
Europace ; 23(9): 1428-1436, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34427302

RESUMO

AIMS: The roles of implantable cardioverter-defibrillators (ICDs) and radiofrequency catheter ablation (RCA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and well-tolerated monomorphic ventricular tachycardia (MVT) are debated. In this multicentre retrospective study, we aimed at reporting the outcome of selected patients with ARVC after RCA without a back-up ICD. METHODS AND RESULTS: Patients with ARVC who underwent RCA of well-tolerated MVT at 10 tertiary centres across 5 countries, without an ICD before and 3 months after RCA, without syncope or electrical storm, and with left ventricular ejection fraction ≥50% were included. In total, 65 ARVC patients [mean age 44.5 ± 13.2 years, 78% males] underwent RCA of MVT between 2003 and 2016. Clinical presentation was palpitations in 51 (80%) patients. One (2%) patient had >1 clinical MVT. At the ablative procedure, clinical MVTs (mean rate 185 ± 32 b.p.m.) were inducible in 50 (81%) patients. Epicardial ablation was performed in 19 (29%) patients. Complete acute success was achieved in 47 (72%) patients. After a median follow-up of 52.4 months (range 12.3-171.4), there was no death or aborted cardiac arrest, and VT recurred in 19 (29%) patients. Survival without VT recurrence was estimated at 88%, 80%, and 68%, 12, 36, and 60 months after RCA, respectively, and was significantly associated with the approach and the procedural outcome. CONCLUSION: In patients with ARVC, well-tolerated MVT without a back-up ICD did not lead to fatal arrhythmic event after RCA despite VT recurrences in some. Our data suggest that RCA may be an alternative to ICD in selected ARVC patients.


Assuntos
Displasia Arritmogênica Ventricular Direita , Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/terapia , Resultado do Tratamento , Função Ventricular Esquerda
11.
Pacing Clin Electrophysiol ; 44(4): 740-743, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33386765

RESUMO

We report a case of inappropriate implantable cardioverter defibrillator (ICD) therapy due to single ventricular fibrillation (VF) zone programming leading to patient death. A remote transmission was received from a patient with a cardiac resynchronization therapy-defibrillator showing sinus tachycardia in the VF detection zone initiating inappropriate shocks and resulting in shock refractory VF. This case report highlights the importance of manufacturer specific ICD programming. In devices without discrimination in the VF zone, a higher rate single VF detection zone and/or addition of a ventricular tachycardia zone with supraventricular tachycardia discrimination should be considered.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Fibrilação Ventricular/prevenção & controle , Alcoolismo/complicações , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária
12.
Pacing Clin Electrophysiol ; 44(2): 318-326, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33377500

RESUMO

OBJECTIVES: To study how left atrial appendage electrical isolation (LAAEI) impacts atrial dominant frequency (DF) in patients with long-standing persistent atrial fibrillation (LSPAF). BACKGROUND: LAAEI is associated with a high probability of freedom from atrial fibrillation (AF) and spectral analysis may identify high-frequency sources. How LAAEI impacts the AF dynamics and the subgroup of LSPAF patients in whom LAAEI would be most beneficial, is unclear. METHODS: Twenty patients with LSPAF were included in the study. Fast Fourier transforms (FFT) were performed on atrial electrograms recorded from 13 sites in the LA and RA. The highest peak frequency was defined as DF. RESULTS: There was no significant difference in DF between atrial sites except for at the superior vena cava which had the lowest DF at baseline. Stepwise ablation consisting of circumferential pulmonary vein isolation and a linear ablation set of mitral isthmus and roof significantly reduced the DF within the coronary sinus (CS) (5.93 ± 0.98 Hz vs. 5.09 ± 0.72 Hz, p < .05) and the LA posterior wall (LApos) (6.26 ± 0.92 Hz vs. 5.43 ± 0.98 Hz, p < .01). LAAEI preferentially further decreased the DF at the LApos (p < .01), but not at the CS. In cases where there was < 13.6% reduction in the DF of the LApos following the stepwise ablation, the addition of LAAEI was associated with an increased restoration of sinus rhythm (55%, p < .05). CONCLUSION: LAAEI in addition to stepwise ablation results in further reduction of the DF in the LApos, which is associated with acute termination of AF and favorable ablation outcome.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/métodos , Protocolos Clínicos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33782987

RESUMO

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino
14.
Eur Heart J ; 41(47): 4471-4480, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-32860414

RESUMO

AIMS: Long-standing persistent atrial fibrillation (LSPAF) is challenging to treat with suboptimal catheter ablation (CA) outcomes. Thoracoscopic surgical ablation (SA) has shown promising efficacy in atrial fibrillation (AF). This multicentre randomized controlled trial tested whether SA was superior to CA as the first interventional strategy in de novo LSPAF. METHODS AND RESULTS: We randomized 120 LSPAF patients to SA or CA. All patients underwent predetermined lesion sets and implantable loop recorder insertion. Primary outcome was single procedure freedom from AF/atrial tachycardia (AT) ≥30 s without anti-arrhythmic drugs at 12 months. Secondary outcomes included clinical success (≥75% reduction in AF/AT burden); procedure-related serious adverse events; changes in patients' symptoms and quality-of-life scores; and cost-effectiveness. At 12 months, freedom from AF/AT was recorded in 26% (14/54) of patients in SA vs. 28% (17/60) in the CA group [OR 1.128, 95% CI (0.46-2.83), P = 0.83]. Reduction in AF/AT burden ≥75% was recorded in 67% (36/54) vs. 77% (46/60) [OR 1.13, 95% CI (0.67-4.08), P = 0.3] in SA and CA groups, respectively. Procedure-related serious adverse events within 30 days of intervention were reported in 15% (8/55) of patients in SA vs. 10% (6/60) in CA, P = 0.46. One death was reported after SA. Improvements in AF symptoms were greater following CA. Over 12 months, SA was more expensive and provided fewer quality-adjusted life-years (QALYs) compared with CA (0.78 vs. 0.85, P = 0.02). CONCLUSION: Single procedure thoracoscopic SA is not superior to CA in treating LSPAF. Catheter ablation provided greater improvements in symptoms and accrued significantly more QALYs during follow-up than SA. CLINICAL TRIAL REGISTRATION: ISRCTN18250790 and ClinicalTrials.gov: NCT02755688.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Humanos , Anos de Vida Ajustados por Qualidade de Vida , Recidiva , Resultado do Tratamento
15.
Europace ; 22(1): 5-18, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31578542

RESUMO

For many years, the left atrial appendage (LAA) was considered a dormant embryological remnant; however, it is a structurally complex and functional organ that contributes to cardiac haemodynamic changes and volume homeostasis through both its contractile properties and neurohormonal peptide secretion. When dysfunctional, the LAA contributes to thrombogenesis and subsequent increased predisposition to cardioembolic events. Consequently, the LAA has gained much attention as a therapeutic target to lower this risk. In addition, attention has focused on the LAA in its role as an electrical trigger for atrial tachycardia and atrial fibrillation with ablation of the LAA to achieve electrical isolation showing promising results in the maintenance of sinus rhythm. This in-depth review explores the structure, physiology and pathophysiology of the LAA, as well as LAA intervention and their sequelae.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Causalidade , Humanos
16.
Europace ; 22(6): 924-931, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32044994

RESUMO

AIMS: We report the collective European experience of percutaneous left atrial appendage (LAA) suture ligation using the recent generation LARIAT+ suture delivery device. METHODS AND RESULTS: A total of 141 patients with non-valvular atrial fibrillation and contraindication to oral anticoagulation (OAC), thrombo-embolic events despite OAC or electrical LAA isolation were enrolled at seven European hospitals to undergo LAA ligation. Patients were followed up by clinical visits and transoesophageal echocardiography (TOE) following LAA closure. Left atrial appendage ligation was completed in 138/141 patients (97.8%). Three patients did not undergo attempted deployment of the LARIAT device due to pericardial adhesion after previous epicardial ventricular tachycardia ablation (n = 1), a pericardial access-related complication (n = 1), and multiple posterior LAA lobes (n = 1). Serious 30-day procedural adverse events occurred in 4/141 patients (2.8%). There were two device-related LAA perforations (1.4%) not resulting in any corrective intervention as the LAA was completely sealed with the LARIAT. Minor adverse events occurred in 19 patients (13.5%), including two pericardial effusions due to procedure-related pericarditis requiring pericardiocentesis. Transoesophageal echocardiography was performed after LAA ligation in 103/138 patients (74.6%) after a mean of 181 ± 72 days. Complete LAA closure was documented in 100 patients (97.1%). Two patients (1.8% of patients with follow-up) experienced a transient ischaemic attack at 4 and 7 months follow-up, although there was no leak observed with TOE. There were two deaths during long-term follow-up which were both not device related. CONCLUSION: Initial experience with the LARIAT+ device demonstrates feasibility of LAA exclusion. Further larger prospective studies with longer follow-up are warranted.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Ligadura , Estudos Prospectivos , Suturas , Resultado do Tratamento
17.
BMC Med Educ ; 20(1): 442, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33203404

RESUMO

BACKGROUND: Vaccination is the most cost-effective medical intervention known to prevent morbidity and mortality. However, data are limited on the effectiveness of residency programs in delivering immunization knowledge and skills to trainees. The authors sought to describe the immunization competency needs of medical residents at the University of Toronto (UT), and to develop and evaluate a pilot immunization curriculum. METHODS: Residents at the University of Toronto across nine specialties were recruited to attend a pilot immunization workshop in November 2018. Participants completed a questionnaire before and after the workshop to assess immunization knowledge and compare baseline change. Feedback was also surveyed on the workshop content and process. Descriptive statistics were performed on the knowledge questionnaire and feedback survey. A paired sample T-test compared questionnaire answers before and after the workshop. Descriptive coding was used to identify themes from the feedback survey. RESULTS: Twenty residents from at least six residencies completed the pre-workshop knowledge questionnaire, seventeen attended the workshop, and thirteen completed the post-workshop questionnaire. Ninety-five percent (19/20) strongly agreed that vaccine knowledge was important to their career, and they preferred case-based teaching. The proportion of the thirty-four knowledge questions answered correctly increased from 49% before the workshop to 67% afterwards, with a mean of 2.24 (CI: 1.43, 3.04) more correct answers (P < 0.001). Sixteen residents completed the post-workshop feedback survey. Three themes emerged: first, they found the content specific and practical; second, they wanted more case-based learning and for the workshop to be longer; and third, they felt the content and presenters were of high quality. CONCLUSIONS: Findings from this study suggest current immunization training of UT residents does not meet their training competency requirements. The study's workshop improved participants' immunization knowledge. The information from this study could be used to develop residency immunization curriculum at UT and beyond.


Assuntos
Internato e Residência , Currículo , Educação de Pós-Graduação em Medicina , Retroalimentação , Humanos , Imunização , Vacinação
18.
Future Gener Comput Syst ; 107: 215-228, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32494091

RESUMO

Three-dimensional late gadolinium enhanced (LGE) cardiac MR (CMR) of left atrial scar in patients with atrial fibrillation (AF) has recently emerged as a promising technique to stratify patients, to guide ablation therapy and to predict treatment success. This requires a segmentation of the high intensity scar tissue and also a segmentation of the left atrium (LA) anatomy, the latter usually being derived from a separate bright-blood acquisition. Performing both segmentations automatically from a single 3D LGE CMR acquisition would eliminate the need for an additional acquisition and avoid subsequent registration issues. In this paper, we propose a joint segmentation method based on multiview two-task (MVTT) recursive attention model working directly on 3D LGE CMR images to segment the LA (and proximal pulmonary veins) and to delineate the scar on the same dataset. Using our MVTT recursive attention model, both the LA anatomy and scar can be segmented accurately (mean Dice score of 93% for the LA anatomy and 87% for the scar segmentations) and efficiently ( ∼ 0.27 s to simultaneously segment the LA anatomy and scars directly from the 3D LGE CMR dataset with 60-68 2D slices). Compared to conventional unsupervised learning and other state-of-the-art deep learning based methods, the proposed MVTT model achieved excellent results, leading to an automatic generation of a patient-specific anatomical model combined with scar segmentation for patients in AF.

19.
Sex Transm Infect ; 95(2): 102-107, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30636706

RESUMO

OBJECTIVE: Internet-based HIV testing offers the potential to address privacy-related barriers to testing and increase frequency of testing but may result in missed opportunities related to sexual health education and prevention that typically occur in face-to-face encounters. In this study, we assessed the HIV test knowledge and sexual risk behaviour of clients testing for HIV through GetCheckedOnline, an internet-based sexually transmitted and bloodborne infection testing platform inclusive of HIV testing, in comparison to clients testing through a large sexual health clinic. METHODS: We concurrently recruited GetCheckedOnline clients and clinic clients from Vancouver, Canada, over the course of a 10-month period during 2015-2016. Participants completed baseline and 3-month questionnaires, anonymous and online. A six-item score was used to estimate knowledge of HIV test concepts typically conveyed during an HIV pretest encounter in a clinic. We used multiple regression to estimate associations between testing modality (online vs clinic based) and two outcomes-HIV test knowledge and change in condom use pre/post-test-with adjustment for relevant background factors. RESULTS: Among 352 participants, online testers demonstrated higher HIV post-test knowledge than clinic-based testers (mean score 4.65/6 vs 4.09/6; p<0.05); this difference was reduced in adjusted analysis (p>0.05). Men who have sex with men, clients with a university degree, those who have lived in Canada >10 years and English speakers had higher HIV post-test knowledge (p<0.05). Eighteen per cent of online testers and 10% of clinic-based testers increased condom use during the 3 months post-test (p>0.05). CONCLUSIONS: In this comparative study between online and clinic-based testers, we found no evidence of decreased HIV test knowledge or decreased condom use following HIV testing through GetCheckedOnline. Our findings suggest that with careful design and attention to educational content, online testing services may not lead to missed opportunities for HIV education and counselling.


Assuntos
Instituições de Assistência Ambulatorial , Infecções por HIV/diagnóstico , Conhecimentos, Atitudes e Prática em Saúde , Internet , Assunção de Riscos , Comportamento Sexual/estatística & dados numéricos , Adulto , Idoso , Testes Diagnósticos de Rotina , HIV , Infecções por HIV/prevenção & controle , Educação em Saúde , Homossexualidade Masculina , Humanos , Masculino , Pessoa de Meia-Idade , Testes Sorológicos , Comportamento Sexual/psicologia , Inquéritos e Questionários , Adulto Jovem
20.
Europace ; 21(4): 655-661, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30815690

RESUMO

AIMS: The objective of this study was to verify acute safety, performance, and usage of a novel ultra-high density mapping system in patients undergoing ablation procedure in a real-world clinical setting. METHODS AND RESULTS: The TRUE HD study enrolled patients undergoing catheter ablation with mapping for all arrhythmias (excluding de novo atrial fibrillation) who were followed for 1 month. Safety was determined by collecting all serious adverse events and adverse events associated with the study devices. Performance was determined as the composite of: ability to map the arrhythmia/substrate, complete the ablation applications, arrhythmia termination (where applicable), and ablation validation. Use of mapping system in the ablation validation workflow was also evaluated. Among the 519 patients who underwent a complete (504) or attempted (15) procedure, 21 (4%) serious ablation-related complications were collected, with 3 (0.57%) potentially related to the mapping catheter. Four hundred and twenty treated patients resulted in a successful procedure confirmed by arrhythmia-specific validation techniques (83.3%; 95% confidence interval: 79.8-86.5%). A total of 1419 electroanatomical maps were created with a median acquisition time of 9:23 min per map. Of these, 372 maps in 222 (44%) patients were collected for ablation validation purposes. Following validation mapping, 162/222 (73%) patients required additional ablation. CONCLUSION: In the TRUE HD study mapping was associated with rates of acute success and complications consistent with previously published reports. Importantly, a low percentage of events (0.57%) was attributed to the mapping catheter. When performed, validation mapping was useful for identifying additional targets for ablation in the majority of patients.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Tamponamento Cardíaco/epidemiologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Traumatismos Cardíacos/epidemiologia , Hematoma/epidemiologia , Humanos , Complicações Intraoperatórias/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Falha de Prótese , Resultado do Tratamento , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA