Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Anal Chem ; 89(17): 9116-9123, 2017 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-28770989

RESUMO

Quantifying the impact of environmental physicochemical changes on the microstructure of lipid delivery systems is challenging. Therefore, we have developed a methodology to quantify the coalescence of oil-in-water emulsion droplets during lipid digestion in situ on a single droplet level. This technique involves a custom-made glass microfluidic platform, in which oil droplets can be trapped as single droplets, or several droplets per trap. The physicochemical environment can be controlled, and droplet digestion, as well as coalescence, can be visualized. We show that the exchange of the physicochemical conditions in the entire reaction chamber can be reached in under 30 s. Microparticle image velocimetry allowed mapping of the flow profile and demonstrated the tuneability of the shear profile in the device. The extraction of quantitative information regarding the physical characteristics of the droplets during digestion was performed using an automated image analysis throughout the digestion process. Therefore, we were able to show that oil-in-water emulsions stabilized by proteins coalesced under human gastric conditions. This coalescence delayed the overall lipid digestion kinetics. The droplets that coalesced during digestion were hydrolyzed 1.4 times slower than individually trapped droplets. Thus, the microstructural evolution of lipid delivery systems is a crucial factor in lipid digestion kinetics. This novel technique allows the simultaneous quantification of the impact that the physicochemical environment has on both the lipid droplet microstructure and the lipid release patterns.


Assuntos
Emulsões/química , Lipídeos/química , Microfluídica/métodos , Sistemas de Liberação de Medicamentos , Cinética , Tamanho da Partícula
2.
Anal Chem ; 87(12): 6265-70, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25984969

RESUMO

The determination of pharmacokinetic properties of drugs, such as the distribution coefficient (D) is a crucial measurement in pharmaceutical research. Surprisingly, the conventional (gold standard) technique used for D measurements, the shake-flask method, is antiquated and unsuitable for the testing of valuable and scarce drug candidates. Herein, we present a simple microfluidic platform for the determination of distribution coefficients using droplet-based liquid-liquid extraction. For simplicity, this platform makes use of gravity to enable phase separation for analysis and is 48 times faster and uses 99% less reagents than performing an equivalent measurement using the shake-flask method. Furthermore, the D measurements achieved in our platform are in good agreement with literature values measured using traditional shake-flask techniques. Since D is affected by volume ratios, we use the apparent acid dissociation constant, pK', as a proxy for intersystem comparison. Our platform determines a pK' value of 7.24 ± 0.15, compared to 7.25 ± 0.58 for the shake-flask method in our hands and 7.21 for the shake-flask method in the literature. Devices are fabricated using injection molding, the batchwise fabrication time is <2 min per device (at a cost of $1 U.S. per device), and the interdevice reproducibility is high.


Assuntos
Extração Líquido-Líquido , Técnicas Analíticas Microfluídicas , Quinina/análise , Técnicas Analíticas Microfluídicas/instrumentação , Tamanho da Partícula , Propriedades de Superfície
3.
Anal Chem ; 85(18): 8866-72, 2013 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-23937555

RESUMO

We present a fully integrated droplet-based microfluidic platform for the high-throughput assessment of photodynamic therapy photosensitizer (PDT) efficacy on Escherichia coli. The described platform is able to controllably encapsulate cells and photosensitizer within pL-volume droplets, incubate the droplets over the course of several days, add predetermined concentrations of viability assay agents, expose droplets to varying doses of electromagnetic radiation, and detect both live and dead cells online to score cell viability. The viability of cells after encapsulation and incubation is assessed in a direct fashion, and the viability scoring method is compared to model live/dead systems for calibration. Final results are validated against conventional colony forming unit assays. In addition, we show that the platform can be used to perform concurrent measurements of light and dark toxicity of the PDT agents and that the platform allows simultaneous measurement of experimental parameters that include dark toxicity, photosensitizer concentration, light dose, and oxygenation levels for the development and testing of PDT agents.


Assuntos
Fenômenos Eletromagnéticos , Ensaios de Triagem em Larga Escala/métodos , Microfluídica/métodos , Fármacos Fotossensibilizantes/análise , Água/análise , Avaliação Pré-Clínica de Medicamentos/métodos , Fármacos Fotossensibilizantes/metabolismo
5.
Chimia (Aarau) ; 66(3): 88-98, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22546251

RESUMO

This account highlights some of our recent activities focused on developing microfluidic technologies for application in high-throughput and high-information content chemical and biological analysis. Specifically, we discuss the use of continuous and segmented flow microfluidics for artificial membrane formation, the analysis of single cells and organisms, nanomaterial synthesis and DNA amplification via the polymerase chain reaction. In addition, we report on recent developments in small-volume detection technology that allow access to the vast amounts of chemical and biological information afforded by microfluidic systems.


Assuntos
Química/métodos , Ensaios de Triagem em Larga Escala/métodos , Técnicas Analíticas Microfluídicas/métodos , Fluorescamina , Nanopartículas/química , Reação em Cadeia da Polimerase , Análise de Célula Única
7.
Anal Chem ; 81(1): 302-6, 2009 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19055421

RESUMO

We present a high throughput microfluidic device for continuous-flow polymerase chain reaction (PCR) in water-in-oil droplets of nanoliter volumes. The circular design of this device allows droplets to pass through alternating temperature zones and complete 34 cycles of PCR in only 17 min, avoiding temperature cycling of the entire device. The temperatures for the applied two-temperature PCR protocol can be adjusted according to requirements of template and primers. These temperatures were determined with fluorescence lifetime imaging (FLIM) inside the droplets, exploiting the temperature-dependent fluorescence lifetime of rhodamine B. The successful amplification of an 85 base-pair long template from four different start concentrations was demonstrated. Analysis of the product by gel-electrophoresis, sequencing, and real-time PCR showed that the amplification is specific and the amplification factors of up to 5 x 10(6)-fold are comparable to amplification factors obtained in a benchtop PCR machine. The high efficiency allows amplification from a single molecule of DNA per droplet. This device holds promise for convenient integration with other microfluidic devices and adds a critical missing component to the laboratory-on-a-chip toolkit.


Assuntos
DNA/química , Técnicas Analíticas Microfluídicas/métodos , Reação em Cadeia da Polimerase/métodos , DNA/genética , Eletroforese/métodos , Corantes Fluorescentes/química , Técnicas Analíticas Microfluídicas/instrumentação , Óleos/química , Reação em Cadeia da Polimerase/instrumentação , Polimetil Metacrilato/química , Rodaminas/química , Temperatura , Água/química
8.
Lab Chip ; 6(4): 471-3, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16572208

RESUMO

A simple and robust derivatisation system for glass and silica microdevices is described. The device surface is coated in a one-step treatment with a highly cross-linked polystyrene/divinylbenzene/allylsiloxane copolymer. The surface derivatisation is highly resistant to solvents, acids, bases and oxidising or reducing agents.


Assuntos
Vidro/química , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Poliestirenos/química , Dióxido de Silício/química , Siloxanas/química , Análise Espectral Raman , Propriedades de Superfície
9.
Biomicrofluidics ; 9(2): 024119, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26015831

RESUMO

The applicability of droplet-based microfluidic systems to many research fields stems from the fact that droplets are generally considered individual and self-contained reaction vessels. This study demonstrates that, more often than not, the integrity of droplets is not complete, and depends on a range of factors including surfactant type and concentration, the micro-channel surface, droplet storage conditions, and the flow rates used to form and process droplets. Herein, a model microfluidic device is used for droplet generation and storage to allow the comparative study of forty-four different oil/surfactant conditions. Assessment of droplet stability under these conditions suggests a diversity of different droplet failure modes. These failure modes have been classified into families depending on the underlying effect, with both numerical and qualitative models being used to describe the causative effect and to provide practical solutions for droplet failure amelioration in microfluidic systems.

10.
Lab Chip ; 2(1): 5-7, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15100849

RESUMO

Monolithic nanoreactors for the safe and expedient continuous synthesis of products requiring unstable intermediates were fabricated and tested by the synthesis of azo dyes under hydrodynamic pumping regimes.

11.
Lab Chip ; 4(5): 417-9, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15472723

RESUMO

Microfluidic devices for spatially localised heating of microchannel environments were designed, fabricated and tested. The devices are simple to implement, do not require complex manufacturing steps and enable intra-channel temperature control to within +/-0.2 degrees C. Ionic liquids held in co-running channels are Joule heated with an a.c. current. The nature of the devices means that the internal temperature can be directly assessed in a facile manner.


Assuntos
Íons/química , Microfluídica/instrumentação , Temperatura , Desenho de Equipamento , Imidazóis/química , Microfluídica/métodos
12.
Curr Opin Drug Discov Devel ; 7(6): 798-806, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15595440

RESUMO

Demands on modern combinatorial chemistry have necessitated massive investment in new synthetic technologies that will allow the production of highly pure drug candidates on short timescales. The advent of microfluidic reactor technologies has recently provided a new tool for the combinatorial chemist, offering the promise of ultra-high-throughput solution-phase chemistries. This review describes why such microscale systems provide unique environments for performing high-efficiency molecular synthesis, details some of the most important recent developments in the field and assesses the true applicability of micro-engineered reactors in high-throughput compound synthesis.


Assuntos
Técnicas de Química Combinatória/instrumentação , Nanotecnologia , Preparações Farmacêuticas/síntese química , Preparações Farmacêuticas/isolamento & purificação
13.
Lab Chip ; 14(21): 4178-82, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25202859

RESUMO

The design, fabrication and testing of facile microcapillary device assembly, suitable for monodisperse double emulsion production is reported. The interface is fabricated in a direct and rapid manner via 3D printing and shown to be robust in the controllable generation of both single and double emulsions at high generation frequencies.

14.
Nat Chem ; 5(11): 905-15, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24153367

RESUMO

The past two decades have seen far-reaching progress in the development of microfluidic systems for use in the chemical and biological sciences. Here we assess the utility of microfluidic reactor technology as a tool in chemical synthesis in both academic research and industrial applications. We highlight the successes and failures of past research in the field and provide a catalogue of chemistries performed in a microfluidic reactor. We then assess the current roadblocks hindering the widespread use of microfluidic reactors from the perspectives of both synthetic chemistry and industrial application. Finally, we set out seven challenges that we hope will inspire future research in this field.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/tendências , Microfluídica/métodos , Microfluídica/tendências , Animais , Pesquisa Biomédica , Indústria Química , Química Verde , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Compostos Orgânicos/síntese química
15.
Drug Test Anal ; 2(10): 496-502, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20886463

RESUMO

Naphyrone (naphthylpyrovalerone, O-2482) has been recently advertised for purchase on a number of websites. This compound has been viewed as a so-called 'legal high' and was classified as a controlled drug under the UK Misuse of Drugs Act 1971 in mid-July 2010. So far, naphyrone is commonly equated with 1-naphthalen-2-yl-2-pyrrolidin-1-yl-pentan-1-one (ß-naphyrone) but analytical characterization of two naphyrone samples revealed the existence of a novel isomer consistent with 1-naphthalen-1-yl-2-pyrrolidin-1-yl-pentan-1-one (α-naphyrone). Analyses of both α- and ß-naphyrone were carried out using gas chromatography ion trap (EI/CI) mass spectrometry and 1D/2D nuclear magnetic resonance spectroscopy. This provides the first report of α-naphyrone in the scientific literature and the ability to differentiate it from the ß-isomer should be of interest to forensic and clinical communities.


Assuntos
Drogas Ilícitas/química , Pentanonas/química , Pirrolidinas/química , Cromatografia Gasosa-Espectrometria de Massas , Isomerismo , Espectroscopia de Ressonância Magnética
16.
17.
Chem Commun (Camb) ; (41): 6225-7, 2009 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-19826676

RESUMO

Using microfluidic techniques and a novel fluorous-tagged palladium catalyst, we generated droplet reactors with catalytically active walls and used these compartments for small molecule synthesis.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Paládio/química , Bibliotecas de Moléculas Pequenas/síntese química , Catálise , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/métodos
18.
Analyst ; 130(1): 46-51, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15614352

RESUMO

An extremely rapid tool for continuous flow synthetic process optimisation is described. A microfluidic reaction system operating in continuous flow is used in conjunction with confocal Raman microscopy to afford rapid molecule synthesis and product quantitation. Accordingly, the approach allows for rapid reaction optimisation within a continuous flow system. Specifically, the catalytic oxidation of isopropyl alcohol (IPA) to acetone using tetra-N-propylammonium perruthanate (TPAP)/N-methylmorpholine N-oxide (NMO) in a radial interdigitated micromixer is studied as a model reaction system. The composition of the reaction effluent can be determined with great facility and information relating to catalyst/co-oxidant ratios, catalyst turnovers and reaction endpoints extracted. Specifically, variation of catalyst and co-oxidant volumetric flow rates between 0 and 50 microL min(-1) is used to vary reactant concentrations, define reaction residence times and control product conversions between 0 and 100%. The rapid nature of the system allows chemical information to be gathered and utilised on a sub-minute timescale.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA