Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Exp Physiol ; 109(2): 255-270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37975151

RESUMO

Women continue to be under-represented in thermoregulatory research despite their undergoing unique physiological changes across the lifespan. This study investigated the biophysical, thermo-physiological, and perceptual determinants of cool-seeking behaviour during exercise in younger and older women. Eleven younger (25 ± 5 years; 1.7 ± 0.1 m; 63.1 ± 5.2 kg) and 11 older women (53 ± 6 years; 1.7 ± 0.1 m; 65.4 ± 13.9 kg) performed a 40-min incremental cycling test in a thermoneutral environment (22 ± 1.7°C; 36 ± 4% relative humidity). Throughout the test, participants freely adjusted the temperature of a cooling probe applied to their wrists to offset their thermal discomfort. We continuously recorded the probe-wrist interface temperature to quantify participants' cool-seeking behaviour. We also measured changes in participants' rate of metabolic heat production, core and mean skin temperatures, and skin wetness. Finally, we body-mapped participants' skin heat, cold and wetness sensitivity. Our results indicated that: (1) older and younger women exhibited similar onset and magnitude of cool-seeking behaviour, despite older women presented reduced autonomic heat-dissipation responses (i.e., whole-body sweat losses); (2) older women's thermal behaviour was less determined by changes in core temperature (this being a key driver in younger women), and more by changes in multiple thermo-physiological and biophysical parameters (i.e., physical skin wetness, temperature and heat production); (3) older women did not present lower regional skin thermal and wetness sensitivity than younger women. We conclude that predictions of female cool-seeking behaviours based on thermo-physiological variables should consider the effects of ageing. These findings are relevant for the design of wearable cooling systems and sports garments that meet the thermal needs of women across the lifespan.


Assuntos
Regulação da Temperatura Corporal , Exercício Físico , Humanos , Feminino , Idoso , Regulação da Temperatura Corporal/fisiologia , Exercício Físico/fisiologia , Temperatura Cutânea , Sudorese , Pele , Temperatura Alta
2.
Exp Physiol ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847458

RESUMO

Female development includes significant morphological changes across the breast. Yet, whether differences in breast surface area (BrSA) modify sweat gland density and output remains unclear. The present study investigated the relationship between BrSA and sweat gland density and output in 22 young to middle-aged women (28 ± $\ \pm \ $ 10 years) of varying breast sizes (BrSA range: 147-561 cm2) during a submaximal run in a warm environment (32  ± $ \pm \ $ 0.6°C; 53  ± $ \pm \ $ 1.7% relative humidity). Local sweat gland density and local sweat rate (LSR) above and below the nipple and at the bra triangle were measured. Expired gases were monitored for the estimation of evaporative requirements for heat balance (Ereq, in W/m2). Associations between BrSA and (i) sweat gland density; (ii) LSR; and (iii) sweat output per gland for the breast sites were determined via correlation and regression analyses. Our results indicated that breast sweat gland density decreased linearly as BrSA increased (r = -0.76, P < 0.001), whereas sweat output per gland remained constant irrespective of BrSA (r = 0.29, P = 0.28). This resulted in LSR decreasing linearly as BrSA increased (r = -0.62, P = 0.01). Compared to the bra triangle, the breast had a 64% lower sweat gland density (P < 0.001), 83% lower LSR (P < 0.001) and 53% lower output per gland (P < 0.001). BrSA (R2 = 0.33, P = 0.015) explained a greater proportion of variance in LSR than Ereq (in W/m2) (R2 = 0.07, P = 0.538). These novel findings extend the known relationship between body morphology and sweat gland density and LSR, to the female breast. This knowledge could innovate user-centred design of sports bras by accommodating breast size-specific needs for sweat management, skin wetness perception and comfort.

3.
Skin Res Technol ; 29(2): e13292, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36823505

RESUMO

BACKGROUND: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non-invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. MATERIALS AND METHODS: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well-established CE-marked non-invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans-epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra-rater reliability between days were evaluated by the same operator. RESULTS: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter-subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra-class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90-017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74-0.4) among sites. CONCLUSION: The study revealed that using non-invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease.


Assuntos
Fenômenos Fisiológicos da Pele , Pele , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Pele/metabolismo , Epiderme , Eritema , Água/metabolismo , Perda Insensível de Água/fisiologia
4.
Skin Res Technol ; 29(1): e13239, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36382670

RESUMO

BACKGROUND: Personal protective equipment, including respirator devices, has been used to protect healthcare workers (HCWs) during the COVID-19 pandemic. These are fitted to skin sites on the face to prevent airborne transmission but have resulted in reports of discomfort and adverse skin reactions from their continued usage. The present study addresses the objective changes in both the structural integrity and biological response of the skin following prolonged and consecutive use of respirators. MATERIALS AND METHODS: A longitudinal cohort study, involving 17 HCWs who wear respirators daily, was designed. Changes in the barrier properties and biological response of the skin were assessed at three facial anatomical sites, namely, the nasal bridge, left cheek and at a location outside the perimeter of respirator. Assessments were made on three different sessions corresponding to the first, second and third consecutive days of mask usage. Skin parameters included transepidermal water loss (TEWL), stratum corneum (SC) hydration and erythema, as well as cytokine biomarkers sampled from sebum using a commercial tape. RESULTS: The cheek and the site outside the perimeter covered by the respirator presented minimal changes in skin parameters. By contrast, significant increases in both the TEWL (up to 4.8 fold) and SC hydration (up to 2.7 fold) were detected at the nasal bridge on the second consecutive day of respirator-wearing. There was a high degree of variation in the individual expression of pro-and anti-inflammatory cytokines. Increasing trends in nasal bridge TEWL values were associated with the body mass index (p < 0.05). CONCLUSIONS: The most sensitive objective parameter in detecting changes in the skin barrier proved to be the increase in TEWL at the nasal bridge, particularly on the second day of consecutive respirator usage. By contrast, other measures of skin were less able to detect remarkable variations in the barrier integrity. Consideration for protecting skin health is required for frontline workers, who continue to wear respirators for prolonged periods over consecutive days during the pandemic.


Assuntos
COVID-19 , Humanos , COVID-19/prevenção & controle , Pandemias/prevenção & controle , Estudos Longitudinais , Água , Ventiladores Mecânicos , Pessoal de Saúde , Atenção à Saúde
5.
Spinal Cord ; 61(2): 111-118, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35978113

RESUMO

STUDY DESIGN: Cohort observational study. OBJECTIVES: To examine the movement profiles of individuals with spinal cord injury (SCI) during their inpatient rehabilitative phase using continuous pressure monitoring (CPM), evaluating the trends in those with skin damage. SETTING: SCI specialist rehabilitation centre in the United Kingdom. METHODS: Individuals with SCI (n = 12) were assessed using CPM in the bed and chair over a 24-72 h. Pressure data was used as a surrogate for movement using both nursing interpretation and an intelligent algorithm. Clinical features were obtained including participants age, injury level, ASIA score, co-morbidities and prescribed support surfaces. Trends between movement profiles (frequency and intervals), SCI demographics and observed skin damage were assessed using cross-tabulation and histograms. RESULTS: The data revealed significant correlations (p < 0.05) between the nursing observation and algorithm for predicting movement, although the algorithm was more sensitive. Individuals with high level injuries (C1-T6) were observed to have a lower frequency of movement and larger intervals between movements when compared to low level injuries (T7-L5) during both lying and sitting periods. The individuals observed to have skin damage were predominantly those who had both a low frequency of movement and extended gaps between movements. CONCLUSIONS: Movements for pressure relief in both the bed and chair environments were dependent on the level of injury in individuals with SCI during their inpatient rehabilitation. Distinct movement patterns corresponded with those who acquired skin damage, revealing the potential clinical applications for technologies to monitor PU risk and inform personalised care.


Assuntos
Úlcera por Pressão , Traumatismos da Medula Espinal , Humanos , Úlcera por Pressão/etiologia , Pacientes Internados , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação , Estudos de Coortes
6.
Skin Pharmacol Physiol ; 36(1): 38-50, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36572004

RESUMO

INTRODUCTION: Proteins, such as cytokines and chemokines, are present in varying concentrations in a range of biofluids, with an important signalling role in maintaining homeostasis. Commercial tapes have been employed to non-invasively collect these potential biomarkers in sebum from the skin surface to examine their concentrations in conditions including acne, atopic dermatitis, and pressure ulcers. However, the identification of robust biomarker candidates is limited by the low abundance of specific proteins extracted by current methodologies. Therefore, this study was designed to develop an optimized extraction method for potential inflammatory biomarkers in sebum collected with Sebutapes. METHODS: Commercial tapes (Sebutapes) coated with synthetic sebum were used to systematically evaluate the effects of chemical and mechanical stimuli on extraction efficiency. Varying concentrations of high- and low-abundance biomarkers (IL-1α, IL-6, IL-8, INF-γ, TNF-α, and IL-1RA) were used to spike the synthetic sebum samples. Methodological variables included different surfactants, mechanical stimuli, and buffer volume. Extraction efficiency was estimated using immunoassay kits from the extracted buffer. RESULTS: The results revealed that the use of a surfactant, i.e., ß-dodecyl maltoside, in addition to the mechanical stimuli, namely, sonication and centrifugation, resulted in an increased recovery of cytokines, ranging from 80% for high-abundant cytokines, such as IL-1α and IL-1RA, and up to 50% for low-abundance cytokines, including TNF-α, IL-6 and IL-8. Compared to previous methods, the new extraction protocol resulted in between a 1.5-2.0-fold increase in extraction efficiency. CONCLUSION: The study revealed that there was a high degree of variability in the extraction efficiency of different cytokines. However, improved efficiency was achieved across all cytokines with selective surfactants and mechanical stimuli. The optimised protocol will provide means to detect low levels of potential biomarkers from skin surface, enabling the evaluation of local changes in pro- and anti-inflammatory cytokines present in different skin conditions.


Assuntos
Biomarcadores , Extração Líquido-Líquido , Sebo , Biomarcadores/química , Biomarcadores/metabolismo , Citocinas/metabolismo , Proteína Antagonista do Receptor de Interleucina 1/metabolismo , Interleucina-6/metabolismo , Interleucina-8/metabolismo , Sebo/química , Sebo/metabolismo , Tensoativos , Fator de Necrose Tumoral alfa , Extração Líquido-Líquido/métodos
7.
J Adv Nurs ; 79(9): 3312-3323, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36919007

RESUMO

AIMS: To explore patient perceptions and understanding of their pressure ulcer risk and how information is communicated between a nurse and patient in the home setting. DESIGN: A pragmatic qualitative research design including community-dwelling patients, who were deemed at risk of developing a pressure ulcer. METHODS: Observation of routine interactions between nurse and patient regarding their pressure ulcer risk and semi-structured interviews with 15 community patients following the nursing interaction. RESULTS: Four key overarching themes emerged from the data analysis that were related to patient perceptions and understanding of pressure ulcer risk. These included Pressure Ulcer Awareness, Importance of Repositioning, Healthy Eating and Risk Interpretation. CONCLUSION: Patient perception and understanding of pressure ulcer risk is different from the scientific, professional view. Patient risk perception was based on heuristics and wider personal factors and social influences. IMPACT: The study provides important new insights into clinical practice in relation to how pressure ulcer advice and information are provided and interpreted in the community setting. REPORTING METHOD: Adhered to the Standards for Reporting Qualitative Research (SRQR) PATIENT OR PUBLIC CONTRIBUTION: A small selection of patients within the NHS Trust in which the research was conducted contributed to the design of the study, in particular some of the interview questions and timing.


Assuntos
Úlcera por Pressão , Humanos , Úlcera por Pressão/etiologia , Pacientes , Pesquisa Qualitativa
8.
Sensors (Basel) ; 23(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37571655

RESUMO

Commercial pressure monitoring systems have been developed to assess conditions at the interface between mattress/cushions of individuals at risk of developing pressure ulcers. Recently, they have been used as a surrogate for prolonged posture and mobility monitoring. However, these systems typically consist of high-resolution sensing arrays, sampling data at more than 1 Hz. This inevitably results in large volumes of data, much of which may be redundant. Our study aimed at evaluating the optimal number of sensors and acquisition frequency that accurately predict posture and mobility during lying. A continuous pressure monitor (ForeSitePT, Xsensor, Calgary, Canada), with 5664 sensors sampling at 1 Hz, was used to assess the interface pressures of healthy volunteers who performed lying postures on two different mattresses (foam and air designs). These data were down sampled in the spatial and temporal domains. For each configuration, pressure parameters were estimated and the area under the Receiver Operating Characteristic curve (AUC) was used to determine their ability in discriminating postural change events. Convolutional Neural Network (CNN) was employed to predict static postures. There was a non-linear decline in AUC values for both spatial and temporal down sampling. Results showed a reduction of the AUC for acquisition frequencies lower than 0.3 Hz. For some parameters, e.g., pressure gradient, the lower the sensors number the higher the AUC. Posture prediction showed a similar accuracy of 63-71% and 84-87% when compared to the commercial configuration, on the foam and air mattress, respectively. This study revealed that accurate detection of posture and mobility events can be achieved with a relatively low number of sensors and sampling frequency.


Assuntos
Postura , Úlcera por Pressão , Humanos , Redes Neurais de Computação , Leitos , Voluntários Saudáveis
9.
J Tissue Viability ; 32(2): 305-313, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36813598

RESUMO

INTRODUCTION: During the COVID-19 pandemic healthcare workers (HCWs) have used respiratory protective equipment for prolonged periods, which has been associated with detrimental effects on the underlying skin. The present study aims to evaluate changes in the main cells (corneocytes) of the stratum corneum (SC) following prolonged and consecutive use of respirators. METHODS: 17 HCWs who wore respirators daily during routine hospital practice were recruited to a longitudinal cohort study. Corneocytes were collected via tape stripping from a negative control site (area outside the respirator) and from the cheek which was in contact with the device. Corneocytes were sampled on three occasions and analysed for the level of positive-involucrin cornified envelopes (CEs) and the amount of desmoglein-1 (Dsg1), as indirect measurements of immature CEs and corneodesmosomes (CDs), respectively. These were compared to biophysical measurements (Transepidermal water loss, TEWL, and SC hydration) at the same investigation sites. RESULTS: A large degree of inter-subject variability was observed, with maximum coefficients of variation of 43% and 30% for the level of immature CEs and Dsg1, respectively. Although it was observed that there was not an effect of prolonged respirator usage on the properties of corneocytes, the level of CDs was greater at the cheek than the negative control site (p < 0.05). Furthermore, low levels of immature CEs correlated with greater TEWL values after prolonged respirator application (p < 0.01). It was also noted that a smaller proportion of immature CEs and CDs was associated with a reduced incidence of self-reported skin adverse reactions (p < 0.001). CONCLUSIONS: This is the first study that investigated changes in corneocyte properties in the context of prolonged mechanical loading following respirator application. Although differences were not recorded over time, the levels of CDs and immature CEs were consistently higher in the loaded cheek compared to the negative control site and were positively correlated with a greater number of self-reported skin adverse reactions. Further studies are required to evaluate the role of corneocyte characteristics in the evaluation of both healthy and damaged skin sites.


Assuntos
COVID-19 , Pandemias , Humanos , Estudos Longitudinais , COVID-19/prevenção & controle , Ventiladores Mecânicos , Atenção à Saúde
10.
J Wound Ostomy Continence Nurs ; 50(6): 512-520, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37966081

RESUMO

PURPOSE: The purpose of this study was to evaluate temporal changes in skin responses following exposure to moisture alone or moisture in combination with mechanical loading. DESIGN: Comparison cohort with a repeated-measures design. SUBJECTS AND SETTINGS: The sample comprised 12 healthy volunteers. Participants were purposely sampled from 2 different age groups; half were 32 to 39 years old and half were 50 to 62 years old. Participants identified as White, Black, or mixed; 83% (n = 10) identified as White; 8 (67%) were female. METHODS: Four sites at the sacrum were challenged with the application of specimens taken from 2 absorbent products; the pad specimens were applied dry or saturated with synthetic urine (SU; pH = 8); a further site from the sacral skin was also selected and used as a control. Skin assessments were performed at different points in time: (1) 60 minutes after exposure to dry or SU-saturated pad specimens; (2) 60 minutes after exposure to pads and mechanical loading (application of pressure in the form of 45°C high sitting); and (3) 30 minutes after removal of all pads (recovery period). Outcome measures were transepidermal water loss (TEWL), stratum corneum (SC) hydration, erythema, pH, and skin inflammatory biomarkers measured at each of the time points described earlier. RESULTS: The control site and those exposed to dry pads showed minimal time-dependent changes irrespective of the parameter investigated. In contrast, significant increases in TEWL (P = .0000007) and SC hydration responses (P = .0000007) were detected at the sites under absorbent pad specimens after saturation with SU (exposure to moisture). In some participants, TEWL and SC hydration parameters were significantly higher during pressure application. Skin pH remained in the mildly acidic range throughout the test session, and no consistent trends were observed with erythema. Skin inflammatory biomarkers also exhibited considerable variability across participants; none changed significantly over time. Significant differences (P = .02) were also detected following the exposure of moisture in combination with pressure. CONCLUSION: We evaluated an array of parameters to identify changes following skin exposure to 2 absorbent pads in the presence and absence of SU and mechanical loading. Analysis revealed changes in skin barrier properties in the presence of moisture and/or pressure. This observation suggests a need for frequent pad changing as well as periods of skin off-loading to protect the skin health of individuals with incontinence.


Assuntos
Tampões Absorventes para a Incontinência Urinária , Pele , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Estudos de Coortes , Eritema , Biomarcadores
11.
Int Wound J ; 20(7): 2594-2607, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36872612

RESUMO

Pressure Ulcers (PU) are a major burden for affected patients and healthcare providers. Current detection methods involve visual assessments of the skin by healthcare professionals. This has been shown to be subjective and unreliable, with challenges associated with identifying erythema in darker colour skin. Although there exists a number of promising non-invasive biophysical techniques such as ultrasound, capacitance measurements, and thermography, the present study focuses on directly measuring the changes in the inflammatory status of the skin and underlying tissues. Therefore, in this study, we aim to analyse inflammatory cytokines collected through non-invasive sampling techniques to detect early signs of skin damage. Thirty hospitalised patients presenting with Stage I PU were recruited to evaluate the inflammatory response of skin at the site of damage and an adjacent healthy control site. Sebutapes were collected over three sessions to investigate the temporal changes in the inflammatory response. The panel of cytokines investigated included high-abundance cytokines, namely, IL-1α and IL-1RA, and low abundance cytokines; IL-6, IL-8, TNF-α, INF-γ, IL-33, IL-1ß and G-CSF. Spatial and temporal differences between sites were assessed and thresholds were used to determine the sensitivity and specificity of each biomarker. The results suggest significant (P < .05) spatial changes in the inflammatory response, with upregulation of IL-1α, IL-8, and G-CSF as well as down-regulation of IL-1RA over the Stage I PU compared with the adjacent control site. There were no significant temporal differences between the three sessions. Selected cytokines, namely, IL-1α, IL-1RA, IL-8, G-CSF, and the ratio IL-1α/IL-1RA offered clear delineation in the classification of healthy and Stage-I PU skin sites, with receiver operating characteristic curves demonstrating high sensitivity and specificity. There were limited influences of intrinsic and extrinsic factors on the biomarker response. Inflammatory markers provided a high level of discrimination between the sites presenting with Stage I PU and an adjacent healthy skin site, in a cohort of elderly inpatients. Indeed, the ratio of IL-1α to IL-1RA provided the highest sensitivity and specificity, indicative that inflammatory homeostasis is affected at the PU site. There was a marginal influence of intrinsic and extrinsic factors, demonstrating the localised effects of the inflammation. Further studies are required to investigate the potential of inflammatory cytokines incorporated within Point of Care technologies, to support routine clinical use.


Assuntos
Úlcera por Pressão , Humanos , Idoso , Úlcera por Pressão/diagnóstico , Proteína Antagonista do Receptor de Interleucina 1 , Interleucina-8 , Estudos Longitudinais , Sebo , Citocinas , Estudos de Coortes , Biomarcadores , Pelve , Fator Estimulador de Colônias de Granulócitos
12.
Int Wound J ; 20(8): 3164-3176, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37060199

RESUMO

In acute care facilities, the detection of pressure ulcers (PUs) relies on visual and manual examination of the patient's skin, which has been reported to be inconsistent and may lead to misdiagnosis. In skin and wound research, various biophysical parameters have been extensively employed to monitor changes in skin health. Nonetheless, the transition of these measures into care settings as part of a routine clinical assessment has been limited. This study was designed to examine the spatial and temporal changes in skin biophysical parameters over the site of a category I PU, in a cohort of hospitalised patients. Thirty patients, each presenting with a category I PU, were enrolled in the study. Skin integrity was assessed at the PU-compromised site and two adjacent areas (5 and 10 cm away). Data was collected over three sessions to examine both temporal differences and longitudinal changes. Skin integrity was assessed using two biophysical parameters, namely, transepidermal water loss (TEWL) and stratum corneum (SC) hydration. In addition, the influence of intrinsic factors, namely, incontinence and mobility status, on the parameters was evaluated. TEWL values at the sites compromised by PU were statistically significantly greater (P < .001) than corresponding values at the adjacent control sites at 5 and 10 cm, which were consistent with a normative range (<20 g/h/m2 ). By contrast, SC hydration values did not reveal clear distinctions between the three sites, with high inter-patient variation detected at the sites. Nevertheless, individual profiles were consistent across the three sessions, and the PU site was observed to be either abnormally dry or overhydrated in different individuals. No consistent temporal trend in either parameter was evident. However, intrinsic factors were shown to influence the parameters, with females, bedridden and incontinent patients presenting significantly higher TEWL and SC hydration values (P < .05). TEWL was able to identify differences in skin responses at skin sites compromised with a category I PU when compared to healthy adjacent skin sites. Accordingly, this parameter could be included in the clinical assessment for the identification of PU risk. Further studies are required to elucidate the role of hydration and skin barrier function in the development of PUs and their ability to monitor temporal changes in skin integrity.


Assuntos
Úlcera por Pressão , Feminino , Humanos , Úlcera por Pressão/diagnóstico , Pele , Epiderme , Água , Supuração
13.
Int Wound J ; 20(2): 579-608, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35906857

RESUMO

The present study sought to explore the impact of movement monitoring devices on risk prediction and prevention of pressure ulcers (PU) among adults. Using systematic review methodology, we included original research studies using a prospective design, written in English, assessing adult patients' movement in bed, using a movement monitoring device. The search was conducted in March 2021, using PubMed, CINAHL, Scopus, Cochrane, and EMBASE databases, and returned 1537 records, of which 25 met the inclusion criteria. Data were extracted using a pre-designed extraction tool and quality appraisal was undertaken using the evidence-based librarianship (EBL). In total, 19 different movement monitoring devices were used in the studies, using a range of physical sensing principles. The studies focused on quantifying the number and types of movements. In four studies the authors compared the monitoring system with PU risk assessment tools, with a variety of high and low correlations observed. Four studies compared the relationship between movement magnitude and frequency and the development of PUs, with variability in results also identified. Two of these studies showed, as expected, that those who made less movements developed more PU; however, the two studies also unexpectedly found that PUs occurred in both low movers and high movers. In the final two studies, the authors focused on the concordance with recommended repositioning based on the results of the monitoring device. Overall, concordance with repositioning increased with the use of a monitoring device. The synthesis of the literature surrounding bed monitoring technologies for PU risk prediction showed that a range of physical sensors can be used to detect the frequency of movement. Clinical studies showed some correlation between parameters of movement and PU risk/incidence, although the heterogeneity of approaches limits generalisable recommendations.


Assuntos
Úlcera por Pressão , Humanos , Adulto , Úlcera por Pressão/diagnóstico , Úlcera por Pressão/prevenção & controle , Movimento , Monitorização Fisiológica , Supuração
14.
J Sep Sci ; 45(2): 542-550, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34796639

RESUMO

Liquid chromatography-mass spectrometry methods were required to afford the rapid separation and detection of purines and small organic acids. These compounds are found in sweat and sebum and are potential biomarkers for the early detection of pressures sores. Two ultra-high-performance supercritical fluid chromatography-mass spectrometry assays have been successfully developed for both classes of compounds. Separation for purines was achieved using a gradient of supercritical carbon dioxide and methanol with a 1-aminoanthracene sub 2 µm particle size column followed by positive ion electrospray ionization. Separation for organic acids was achieved using a gradient of supercritical carbon dioxide and methanol (50 mM ammonium acetate 2% water) with a Diol sub 2 µm particle size column followed by negative ion electrospray ionization. Calibration curves were created in the absence of internal standards and R2 values > 0.96 were achieved using single ion monitoring methods for the protonated purines and the deprotonated acids. The two new assays afford rapid analytical methods for the separation and detection of potential biomarkers in human sweat leading to the early detection and prevention of pressure sores.


Assuntos
Cromatografia com Fluido Supercrítico , Biomarcadores , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia com Fluido Supercrítico/métodos , Humanos , Espectrometria de Massas , Suor
15.
Skin Res Technol ; 28(1): 187-199, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34708455

RESUMO

BACKGROUND: Skin sensitivity (SS) is a commonly occurring response to a range of stimuli, including environmental conditions (e.g., sun exposure), chemical irritants (e.g., soaps and cosmetics), and mechanical forces (e.g., while shaving). From both industry and academia, many efforts have been taken to quantify the characteristics of SS in a standardised manner, but the study is hindered by the lack of an objective definition. METHODS: A review of the scientific literature regarding different parameters attributed to the loss of skin integrity and linked with exhibition of SS was conducted. Articles included were screened for mechanical stimulation of the skin, with objective quantification of tissue responses using biophysical or imaging techniques. Additionally, studies where cohorts of SS and non-SS individuals were reported have been critiqued. RESULTS: The findings identified that the structure and function of the stratum corneum and its effective barrier properties are closely associated with SS. Thus, an array of skin tissue responses has been selected for characterization of SS due to mechanical stimuli, including: transepidermal water loss, hydration, redness, temperature, and sebum index. Additionally, certain imaging tools allow quantification of the superficial skin layers, providing structural characteristics underlying SS. CONCLUSION: This review proposes a multimodal approach for identification of SS, providing a means to characterise skin tissue responses objectively. Optical coherence tomography (OCT) has been suggested as a suitable tool for dermatological research with clinical applications. Such an approach would enhance the knowledge underlying the multifactorial nature of SS and aid the development of personalised solutions in medical and consumer devices.


Assuntos
Fenômenos Fisiológicos da Pele , Pele , Epiderme , Eritema , Humanos , Sebo
16.
J Neuroeng Rehabil ; 19(1): 42, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35501879

RESUMO

BACKGROUND: After amputation, many people become less active, feel lonely and lose independence. Understanding the factors associated with low physical activity levels and participation could contribute to defining key interventions which can support prosthesis users so they can live a more active and socially included lifestyle. This longitudinal observational study aims to assess relationships between physical activity, community participation, prosthetic fit, comfort and user satisfaction using actimetry, 3D scans and questionnaires in a Cambodian cohort of established lower limb prosthesis users. METHODS: Twenty participants (5F:15M, nine transfemoral, eleven transtibial, 24-60 years old and 3-43 years since amputation) were recruited. They completed a questionnaire which included their demographics, community participation, prosthesis satisfaction and comfort at the start of the study, and between three and six months later. Their prosthetic sockets and residual limbs were 3D scanned at the start and end of the study. Accelerometers were embedded under the cosmesis on the shank of the prosthesis, to collect ten weeks of activity data. RESULTS: Participants averaged 4470 steps/day (743-7315 steps/day), and wore their prosthesis for most waking hours, averaging 13.4 h/day (4.5-17.6 h/day). Self-reported measures of activity and hours of wear correlated with these accelerometer data (Spearman's rho rs = 0.59, and rs = 0.71, respectively). Participants who were more active wore their prosthesis for more hours/day (Pearson r = 0.73) and were more satisfied with socket fit (rs = 0.49). A longer residual limb correlated with better community participation (rs = 0.56) and comfort (rs = 0.56). Self-reported community participation did not correlate with a person's activity level (rs = 0.13), or their prosthesis comfort (rs = 0.19), and there was only weak correlation between how important the activity was to an individual, and how often they participated in it (rs = 0.37). A simple 0-10 scale of overall comfort did not provide enough detail to understand the types and severity of discomfort experienced. CONCLUSION: Associations between perceived and measured activity levels correlated with socket satisfaction in this cohort of people with established lower limb amputations. The small sample size means these correlations should be interpreted with caution, but they indicate variables worthy of further study to understand barriers to community engagement and physical activity for prosthesis users in Cambodia, and potentially in other settings.


Assuntos
Membros Artificiais , Adulto , Cotos de Amputação , Povo Asiático , Estudos de Coortes , Participação da Comunidade , Humanos , Pessoa de Meia-Idade , Adulto Jovem
17.
J Tissue Viability ; 31(1): 119-129, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34949521

RESUMO

Pressure ulcers (PUs) occur in a range of care settings, resulting in reduced quality of life for the individual. There has been a growing awareness that medical devices can cause PUs, although reporting has been limited. There is a need to evaluate PU reporting practice and identify whether standards exist for medical device-related pressure ulcers (MDRPUs). AIM: To synthesize academic and grey literature relevant to reporting of PUs and MDRPUs in healthcare settings. METHODS: A systematic search of multiple scientific and grey literature databases was undertaken. Key search terms and Boolean operators were used to identify relevant literature. All sources of evidence discussing reporting practices were included in a synthesis. Primary topics are discussed in the corresponding analysis. RESULTS: Thirty-one evidence sources met the inclusion criteria, including 16 journal articles and 15 policy and guidance documents. The results revealed a variation in reporting practices. MDRPUs were often not identified as a separate category in local and national systems. Policies for related patient safety reporting varied across all organisational levels, with more serious categories of PUs reported more consistently. Reporting to medical device regulatory bodies was not mandatory. CONCLUSION: This narrative review identified inconsistencies in local and national reporting of PUs and MDRPUs, prohibiting meaningful comparisons and improvements in patient safety. Lack of specific medical device data and low levels of voluntary reporting to regulatory bodies is likely to result in an under-reporting, with little evidence of specific devices which may be a patient safety concern.


Assuntos
Úlcera por Pressão , Humanos , Políticas , Úlcera por Pressão/etiologia , Úlcera por Pressão/prevenção & controle , Qualidade de Vida
18.
J Tissue Viability ; 30(3): 434-438, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33893014

RESUMO

BACKGROUND: Technologies have been developed to monitor changes in dermal oedema, indicative of the early signs of pressure ulcers. However, there is limited information on the effects of regional differences in tissue morphology on these sub-epidermal moisture (SEM) parameters. This study was designed to investigate the absolute SEM readings across different anatomical sites using a commercial device. METHODS: Twenty-four healthy participants were recruited to evaluate basal SEM values at different bony prominences, sampled by an experienced operator. RESULTS: Distinct differences were observed in unloaded SEM values across different anatomical sites, notably between the upper and lower extremities. A high degree of variability was observed in particular sites, such as the heels. Moreover, SEM values at certain locations revealed significant relationships with age, BMI and gender (p < 0.05). CONCLUSION: The study revealed a high level of variability between and within anatomical sites in a healthy cohort of participants. Determining the changes in local skin and sub-dermal tissue status using SEM may require consideration of both site specific and individual demographic factors, with further research needed in cohorts at risk of pressure ulcers.


Assuntos
Bioacumulação/fisiologia , Edema/diagnóstico , Umidade/efeitos adversos , Tela Subcutânea/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Edema/fisiopatologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Tela Subcutânea/anormalidades
19.
Int Wound J ; 18(3): 312-322, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33507634

RESUMO

Since the outbreak of COVID-19 pandemic, clinicians have had to use personal protective equipment (PPE) for prolonged periods. This has been associated with detrimental effects, especially in relation to the skin health. The present study describes a comprehensive survey of healthcare workers (HCWs) to describe their experiences using PPE in managing COVID-19 patients, with a particular focus on adverse skin reactions. A 24-hour prevalence study and multi-centre prospective survey were designed to capture the impact of PPE on skin health of hospital staff. Questionnaires incorporated demographics of participants, PPE type, usage time, and removal frequency. Participants reported the nature and location of any corresponding adverse skin reactions. The prevalence study included all staff in intensive care from a single centre, while the prospective study used a convenience sample of staff from three acute care providers in the United Kingdom. A total of 108 staff were recruited into the prevalence study, while 307 HCWs from a variety of professional backgrounds and demographics participated in the prospective study. Various skin adverse reactions were reported for the prevalence study, with the bridge of the nose (69%) and ears (30%) being the most affected. Of the six adverse skin reactions recorded for the prospective study, the most common were redness blanching (33%), itchiness (22%), and pressure damage (12%). These occurred predominantly at the bridge of the nose and the ears. There were significant associations (P < .05) between the adverse skin reactions with both the average daily time of PPE usage and the frequency of PPE relief. The comprehensive study revealed that the use of PPE leads to an array of skin reactions at various facial locations of HCWs. Improvements in guidelines are required for PPE usage to protect skin health. In addition, modifications to PPE designs are required to accommodate a range of face shapes and appropriate materials to improve device safety.


Assuntos
COVID-19/epidemiologia , Transmissão de Doença Infecciosa/prevenção & controle , Pessoal de Saúde , Hipersensibilidade/etiologia , Equipamento de Proteção Individual/efeitos adversos , Pele , Feminino , Humanos , Hipersensibilidade/epidemiologia , Masculino , Pandemias , Prevalência , Estudos Prospectivos , SARS-CoV-2 , Inquéritos e Questionários , Reino Unido/epidemiologia
20.
Microcirculation ; 27(7): e12645, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32603524

RESUMO

OBJECTIVE: Pressure ulcers are caused by prolonged mechanical loads deforming the underlying soft tissues. However, the mechanical loads for microcirculatory occlusion are unknown. The present study was designed to characterize the simultaneous response of microvascular and lymphatic structures under repeated mechanical loading. METHODS: The effects of two distinct loading/unloading cycles involving (a) incremental pressures 30, 60, and 90 mmHg and (b) three repeated cycles of 30 mmHg were evaluated on a cohort of able-bodied volunteers. Microvascular response involved the monitoring of transcutaneous gas tensions, while dermal lymphatic activity was estimated from near-infrared imaging. Responses were compared during each load and recovery cycle. RESULTS: Changes in microvascular response were dependent on the load magnitudes, with 30 mmHg resulting in a reduction in oxygen tension only, while 90 mmHg affected both oxygen and carbon dioxide values in most cases (54%). By contrast, lymphatics revealed near total occlusion at 30 mmHg. Although there were intersubject differences, temporal trends consistently revealed partial or full impairment under load, with recovery during off-loading. CONCLUSIONS: The pressure required to cause microcirculatory occlusion differed between individuals, with lymphatic impairment occurring at a lower pressure to that of microvascular vessels. This highlights the need for personalized care strategies and regular off-loading of vulnerable tissues.


Assuntos
Vasos Linfáticos/fisiopatologia , Úlcera por Pressão/etiologia , Úlcera por Pressão/fisiopatologia , Pele/irrigação sanguínea , Pele/fisiopatologia , Adulto , Fenômenos Biomecânicos , Monitorização Transcutânea dos Gases Sanguíneos , Feminino , Humanos , Vasos Linfáticos/diagnóstico por imagem , Masculino , Testes Mecânicos/instrumentação , Testes Mecânicos/métodos , Microcirculação/fisiologia , Pressão , Úlcera por Pressão/diagnóstico por imagem , Pele/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho , Estresse Mecânico , Vasoconstrição/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA