Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 136(5): 1144-1156, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420676

RESUMO

Smaller mean airway tree caliber is associated with airflow obstruction and chronic obstructive pulmonary disease (COPD). We investigated whether airway tree caliber heterogeneity was associated with airflow obstruction and COPD. Two community-based cohorts (MESA Lung, CanCOLD) and a longitudinal case-control study of COPD (SPIROMICS) performed spirometry and computed tomography measurements of airway lumen diameters at standard anatomical locations (trachea-to-subsegments) and total lung volume. Percent-predicted airway lumen diameters were calculated using sex-specific reference equations accounting for age, height, and lung volume. The association of airway tree caliber heterogeneity, quantified as the standard deviation (SD) of percent-predicted airway lumen diameters, with baseline forced expired volume in 1-second (FEV1), FEV1/forced vital capacity (FEV1/FVC) and COPD, as well as longitudinal spirometry, were assessed using regression models adjusted for age, sex, height, race-ethnicity, and mean airway tree caliber. Among 2,505 MESA Lung participants (means ± SD age: 69 ± 9 yr; 53% female, mean airway tree caliber: 99 ± 10% predicted, airway tree caliber heterogeneity: 14 ± 5%; median follow-up: 6.1 yr), participants in the highest quartile of airway tree caliber heterogeneity exhibited lower FEV1 (adjusted mean difference: -125 mL, 95%CI: -171,-79), lower FEV1/FVC (adjusted mean difference: -0.01, 95%CI: -0.02,-0.01), and higher odds of COPD (adjusted odds ratio: 1.42, 95%CI: 1.01-2.02) when compared with the lowest quartile, whereas longitudinal changes in FEV1 and FEV1/FVC did not differ significantly. Observations in CanCOLD and SPIROMICS were consistent. Among older adults, airway tree caliber heterogeneity was associated with airflow obstruction and COPD at baseline but was not associated with longitudinal changes in spirometry.NEW & NOTEWORTHY In this study, by leveraging two community-based samples and a case-control study of heavy smokers, we show that among older adults, airway tree caliber heterogeneity quantified by CT is associated with airflow obstruction and COPD independent of age, sex, height, race-ethnicity, and dysanapsis. These observations suggest that airway tree caliber heterogeneity is a structural trait associated with low baseline lung function and normal decline trajectory that is relevant to COPD.


Assuntos
Pulmão , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Feminino , Masculino , Idoso , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria/métodos , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Volume Expiratório Forçado/fisiologia , Estudos de Casos e Controles , Capacidade Vital/fisiologia , Pessoa de Meia-Idade , Estudos Longitudinais , Tomografia Computadorizada por Raios X/métodos , Obstrução das Vias Respiratórias/fisiopatologia , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA