Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 199(10): 1151-1157, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-36946136

RESUMO

Radon-222 (Rn-222) exhalation rate is vital for estimating radiation risk from many kinds of materials. AlphaGUARD measures the radon concentration based on the ionization chamber principle, which is currently recognized as a reference instrument to measure radon. In China, measurements of radon exhalation rate are performed by AlphaGUARD operated in flow-through mode on a reference device to verify measurement accuracy. These measurements are performed in both open and closed loop. AlphaGUARD can fast rapidly the variation of the radon concentration in the chamber, which is tightly pressed against the surface of the medium to accumulate the exhaled radon. When the model is used to obtain the radon exhalation rate, the radon exhalation rates obtained by nonlinear data fitting on the measured radon concentrations are similar to the reference value of the device. The difference of radon exhalation rate values of six measurements is small.


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Radônio , Radônio/análise , Expiração , Poluentes Radioativos do Ar/análise
2.
J Environ Radioact ; 266-267: 107226, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37418812

RESUMO

Radon exhalation rate from soil is a critical factor in evaluating environmental radon levels. However, AlphaGUARD PQ2000PRO may have some sensitivity towards thoron, which can have a significant impact on radon measurement. The traditional radon exhalation models generally ignore the presence of thoron, leading to an overestimation of the radon exhalation rate from soil. To handle this issue, a new model was proposed based on an analysis of several previous studies on radon exhalation theories. To prove the feasibility of the model, the radon exhalation rate measurements were performed by two different types of detectors-AlphaGUARD PQ2000PRO and RAD7. The radon exhalation rate obtained by using the new model is in good agreement with that obtained by using the theoretical model of radon exhalation of RAD7 within one standard error. This new model can be applied to accurately measure radon exhalation rate from soil by the PIC detector (PQ2000PRO).


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Radônio , Poluentes Radioativos do Solo , Radônio/análise , Solo , Poluentes Radioativos do Ar/análise , Expiração , Poluentes Radioativos do Solo/análise
3.
Appl Radiat Isot ; 199: 110894, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37302298

RESUMO

The U.S. Environmental Protection Agency established the maximum contaminant level limit for radon concentration in drinking water as 11.1 Bq L-1. A new device based on the bubbling method with a 290 mL sample bottle was designed for intermittent continuous measurement of water radon concentration. A STM32 is used to control the switch of the water pump and the valves. The Water-Radon-Measurement software written in C# is to connect RAD7 and calculate the water radon concentration automatically.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA