1.
Radiat Prot Dosimetry ; 198(3): 158-166, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35165744

RESUMO

This study aims to determine the radiation doses of patients and staff during different interventional radiology and cardiology examinations. Dose measurements for interventional radiology examinations were performed in Ibn-i Sina Hospital of Ankara University using Siemens Artis-Zee medical imaging system. Patient dose measurement was carried out for interventional cardiology examinations in Cardiology Department of TOBB-ETU University, Medical Faculty Hospital using Philips Allura Centron interventional X-ray system. Patient doses were obtained in terms of kerma area product (KAP) and cumulative air kerma (CAK) from KAP meter attached to the angiography system. Performance tests of the angiography system were performed before patient dose measurements. Staff dose measurements were carried out with thermoluminescence dosimeters (TLD-100) placed in certain areas on the staff. Patient dose measurements were performed for 15 different interventional radiology examinations on a total of 431 patients and for four different cardiology examinations on a total of 299 patients. Monte Carlo based PCXMC 2.0 program was used to calculate patient effective doses. Lower extremity arteriography was the most common examination with a mean KAP value of 30 Gy cm2 and mean effective dose value of 1.2 mSv for total number of 194 patients. Mean KAP values calculated for coronary angiography, percutaneous coronary intervention, electrophysiological procedures and radiofrequency cardiac ablation examinations were 62.8, 162.8, 16.7 and 70.6 Gy cm2, respectively. Radiologist, nurse and technician effective dose normalised to the unit KAP of patient dose were 0.15, 0.11 and 0.14 µSv Gy-1 cm-2. Similarly, cardiologist, nurse and technician effective dose normalised to the unit KAP of patient dose were 0.22, 0.15 and 0.09 µSv Gy-1 cm-2. Measured KAP and CAK values vary depending on the type and complexity of the examination. The measured staff doses during cardiac examinations were higher when compared with that measured for interventional radiology as expected.


Assuntos
Cardiologia , Radiologia Intervencionista , Cardiologia/métodos , Angiografia Coronária , Humanos , Doses de Radiação , Radiografia Intervencionista/métodos
2.
Med Phys ; 47(9): 3935-3944, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32427360

RESUMO

PURPOSE: The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. METHODS: Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were used in the study. The physical image quality assessments were carried out using effective detective quantum efficiency (eDQE) metric and subjective performance of the digital radiography systems was evaluated in terms of inverse image quality figure (IQFinv ) derived from the contrast-detail (CD) diagrams using CDRAD 2.0 phantom and CDRAD phantom analyzer software. All measurements were performed for different tube voltages (70, 81, 90, 102, 110, and 125 kVp) and polymethyl methacrylate (PMMA) phantom thicknesses. An anthropomorphic chest phantom and visual grading analysis (VGA) technique based on European image quality criteria for chest radiography were used for clinical image quality evaluation. RESULTS: The Spearman correlation coefficients were calculated for the investigation of the correlation between physical image quality and clinical image quality. The results showed strong positive correlation between the physical and clinical image quality findings. The minimum correlation coefficient was 0.91 (p < 0.011) for IQFinv vs VGA scores and 0.92 (p < 0.009) for IeDQE vs VGA scores. CONCLUSIONS: Our results confirm that clinical image quality can be predicted with both physical assessments and contrast-detail detectability studies.


Assuntos
Intensificação de Imagem Radiográfica , Tórax , Imagens de Fantasmas , Radiografia , Radiografia Torácica , Software