Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int J Cardiol ; 174(2): 313-7, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24768390

RESUMO

BACKGROUND: Although combined supine and prone acquisitions improve the detection of inferolateral obstructive coronary artery disease (CAD), the predictors of inaccurate detection of inferolateral ischemia have not been reported by using cadmium zinc telluride (CZT) myocardial perfusion imaging (MPI). METHODS AND RESULTS: Vasodilator stress (99m)Tc tetrofosmin MPI using CZT camera and coronary angiography was performed in 322 patients within an interval of 2 months. Prone MPI was performed immediately after supine MPI. Narrowing of the luminal diameter ≥ 75% was considered significant. The presence of an abnormality on both supine and prone images was considered significant. Combined supine and prone imaging, compared with supine-only quantification, was more specific (93% vs. 72%, respectively, p<0.0001) and accurate (88% vs. 74%, p<0.0001) without compromising sensitivity (82% vs. 68%, p=0.10). The area under the curve for detecting inferolateral ischemia was 0.769 (95% CI 0.705-0.833) for supine imaging and 0.802 (95% CI 0.730-0.875) for combined supine and prone imaging (p<0.05). Multivariable analysis revealed that previous inferolateral myocardial infarction was an independent predictor of a false diagnosis (odds ratio=3.45, 95% confidence interval [CI] 1.62-7.37, p<0.001). CONCLUSIONS: Combined supine and prone quantitative CZT MPI enhances the detection of inferolateral CAD without adversely affecting its sensitivity. However, we recommend inferolateral ischemia be monitored in patients with a history of previous inferolateral MI because previous inferolateral MI is a predictor of inaccurate diagnosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Posicionamento do Paciente , Idoso , Cádmio , Feminino , Câmaras gama , Humanos , Masculino , Decúbito Ventral , Reprodutibilidade dos Testes , Estudos Retrospectivos , Decúbito Dorsal , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco
2.
Cardiovasc Revasc Med ; 15(2): 80-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24684758

RESUMO

OBJECTIVES: The aim of this study was to identify predictors of significant LCx-ostium compromise after distal unprotected left main coronary artery (ULMCA) stenting on the basis of baseline intravascular ultrasound (IVUS). BACKGROUND: Provisional single-stenting is considered as the default strategy for non-true bifurcation lesions in ULMCA. However, in certain cases, left circumflex artery (LCx)-ostium stenting is necessary. METHODS: A total of 77 patients underwent percutaneous coronary intervention with drug-eluting stents for non-true bifurcation lesions in ULMCA and had IVUS evaluation. Pre-procedural IVUS was performed to measure cross-sectional areas at the following segments: left main trunk, left anterior descending artery (LAD)-ostium. Post-stenting-narrowing at the circumflex ostium (PSN-LCx) was defined as the presence of more than 50% diameter stenosis at the LCx-ostium as determined by quantitative coronary angiography analysis. RESULTS: PSN-LCx occurred in 27 (35%) patients. The presence of calcified plaque at the culprit lesion as identified by IVUS was more frequently observed in the PSN-LCx group as compared to the non-PSN-LCx group (81.5% vs. 22.0%, p<0.001). Calcium arc in the PSN-LCx group was significantly greater than that in the non-PSN-LCx group (118.1°±69.9° vs. 36.9°±63.0°, p<0.001). On multivariable analysis, a calcium arc>60° was an independent predictor of PSN-LCx (odds ratio: 5.12, 95% confidence interval: 1.21-25.01, p=0.03). CONCLUSIONS: The presence of calcified plaque at the culprit lesion appears to be one of the factors involved in LCx-ostial compromise in non-true bifurcation ULMCA lesions, especially when the calcium arc is >60°.


Assuntos
Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Ultrassonografia de Intervenção , Calcificação Vascular/terapia , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Humanos , Itália , Japão , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
3.
J Cardiol ; 64(6): 488-95, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24794757

RESUMO

BACKGROUND: To evaluate the role of integrated backscatter intravascular ultrasound (IB-IVUS) in assessing the morphology of neointima in bare-metal stent (BMS) and drug-eluting stent (DES) restenosis as compared to the gold-standard, optical coherence tomography (OCT). METHODS: A total of 120 cross-sections were evaluated by IB-IVUS and OCT at five cross-sections from 24 patients (24 lesions): at the minimal lumen area (MLA) and at 1 and 2mm proximal and distal to the MLA site in 24 lesions (9 treated with DES and 15 treated with BMS). IB-IVUS and OCT findings were analyzed according to the time at which restenosis was identified (early <12 months and late ≥12 months) and the stent type. RESULTS: IB-IVUS was found to correctly characterize the neointima of both BMS and DES in-stent restenosis (ISR) as compared to OCT. The overall agreement between the pattern of ISR neointima by IB-IVUS and that by OCT was excellent (kappa=0.85, 95% CI 0.76-0.94). Late DES ISR was characterized by more non-homogeneous, low backscatter and lipid-laden neointima, as compared to the BMS equivalent (BMS vs. DES, 45.0% vs. 80.0%, p<0.01; 51.7% vs. 85.0%, p=0.008; 33.3% vs. 65.0%, p<0.01, respectively). CONCLUSIONS: IB-IVUS assessment of the ISR neointima pattern appears to provide similar information as the gold-standard OCT in patients with stable angina. Both modalities suggested that late DES restenosis is characterized by a non-homogeneous lipid-laden neointima.


Assuntos
Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Neointima/diagnóstico por imagem , Stents , Idoso , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Stents Farmacológicos , Feminino , Humanos , Masculino , Desenho de Prótese , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
6.
J Am Chem Soc ; 128(32): 10413-22, 2006 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-16895406

RESUMO

Because sugar and its derivatives play important roles in various biological phenomena, the rapid and high-throughput analysis of various glycoconjugates is keenly desirable. We describe herein the construction of a novel fluorescent lectin array for saccharide detection using a supramolecular hydrogel matrix. In this array, the fluorescent lectins were noncovalently fixed under semi-wet conditions to suppress the protein denaturation. It is demonstrated by fluorescence titration and fluorescence lifetime experiments that the immobilized lectins act as a molecular recognition scaffold in the hydrogel matrix, similar to that in aqueous solution. That is, a bimolecular fluorescence quenching and recovery (BFQR) method can successfully operate under both conditions. This enables one to fluorescently read-out a series of saccharides on the basis of the recognition selectivity and affinity of the immobilized lectins without tedious washing processes and without labeling the target saccharides. Simple and high-throughput sensing and profiling were carried out using the present lectin array for diverse glycoconjugates, which not only included a simple glucose, but also oligosaccharides, and glycoproteins, and, furthermore, the pattern recognition and profiling of several types of cell lysates were also accomplished.


Assuntos
Corantes Fluorescentes/química , Glicoconjugados/análise , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Lectinas/química , Análise Serial de Proteínas , Estrutura Molecular
7.
Chemistry ; 11(4): 1130-6, 2005 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-15619729

RESUMO

A pH-responsive volume-change function was successfully introduced into a supramolecular hydrogel that contained GalNAc-appended (GalNAc=N-acetylgalactosamine) glutamate ester 1 by the simple mixing of it with an appropriate amount of 2 a or 2 b amphiphilic carboxylic acid. In the 1:1 mixture (1:2), the hydrogel swelled under neutral pH conditions, but shrank to almost half of its original volume under acidic pH conditions. The structure and pH response of the mixed hydrogel were characterized by using X-ray diffraction (XRD), confocal laser scanning microscopy (CLSM), transmission or scanning electron microscopy (TEM, SEM), and Fourier transform IR (FTIR) spectroscopy. Well-developed fibers formed a stable hydrogel by self-assembly, and under acidic conditions the charge of the carboxylic acid terminal (from the carboxylate anion) was neutralized and then these fibers became densely packed. This macroscopic pH response was also applied to the pH-triggered release of bioactive substances. In this mixed supramolecular hydrogel, the hydrogelator 1 provides a stable hydrogel structure and the additive 2 acts as a commander that is sensitive to an environmental pH signal. The present supramolecular copolymerization strategy should be useful for the construction of novel, stimuli-responsive, soft materials.

8.
J Am Chem Soc ; 126(39): 12204-5, 2004 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-15453719

RESUMO

This communication describes a new molecular recognition chip using a semi-wet microenvironment provided by a self-assembled hydrogel. On the basis of the evidence that the molecular recognition capability of artificial chemosensors are practically retained even in the hydrogel compared to those in aqueous solution, we miniaturized the functionalized hydrogel to produce an unprecedented molecular recognition chip. We believe that the present noncovalent immobilization method is generally applicable to many chemosensors, which leads to a unique semi-wet sensor chip suitable to convenient and high-throughput assay to plural analytes.


Assuntos
Técnicas Biossensoriais/métodos , Hidrogéis/química , Aminoácidos/química , Cátions/química , Glicosilação , Metais/química , Microscopia de Força Atômica , Análise Serial de Proteínas/métodos , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA