Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 187(2): 464-480.e10, 2024 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-38242088

RESUMO

Primary open-angle glaucoma (POAG), the leading cause of irreversible blindness worldwide, disproportionately affects individuals of African ancestry. We conducted a genome-wide association study (GWAS) for POAG in 11,275 individuals of African ancestry (6,003 cases; 5,272 controls). We detected 46 risk loci associated with POAG at genome-wide significance. Replication and post-GWAS analyses, including functionally informed fine-mapping, multiple trait co-localization, and in silico validation, implicated two previously undescribed variants (rs1666698 mapping to DBF4P2; rs34957764 mapping to ROCK1P1) and one previously associated variant (rs11824032 mapping to ARHGEF12) as likely causal. For individuals of African ancestry, a polygenic risk score (PRS) for POAG from our mega-analysis (African ancestry individuals) outperformed a PRS from summary statistics of a much larger GWAS derived from European ancestry individuals. This study quantifies the genetic architecture similarities and differences between African and non-African ancestry populations for this blinding disease.


Assuntos
Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto , Humanos , Predisposição Genética para Doença , Glaucoma de Ângulo Aberto/genética , População Negra/genética , Polimorfismo de Nucleotídeo Único/genética
2.
J Glaucoma ; 33(7): 490-498, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619387

RESUMO

PRCIS: Optic disc microvasculature dropout (MvD-D) was associated with worse disease severity in pre-perimetric glaucoma. MvD-D was not accompanied by focal lamina cribrosa defect or parapapillary deep-layer microvasculature dropout in 62.3% and 71.0% of eyes, respectively. PURPOSE: To investigate factors associated with optic disc microvasculature dropout (MvD-D) in patients with preperimetric primary open angle glaucoma (PPG). METHODS: One hundred thirty nine eyes of PPG patients were categorized according to the presence of MvD-D with optical coherence tomography angiography (OCTA). Factors including visual field (VF) mean deviation (MD), retinal nerve fiber layer (RNFL) thickness, focal lamina cribrosa (LC) defect, optic disc hemorrhage (DH), and parapapillary deep-layer microvasculature dropout (MvD-P) were compared between eyes with and without MvD-D. RESULTS: MvD-D was observed in 69 PPG eyes (49.6%). Compared with eyes without MvD-D, the ones with MvD-D had a significantly thinner RNFL in all areas except the nasal sector, worse VF MD, and a focal LC defect and MvD-P ( P <0.05): male gender also was more highly prevalent. A considerable number of eyes with MvD-D lacked focal LC defect (62.3% [43/69]) or MvD-P (71.0% [49/69]), while a few eyes without MvD-D had focal LC defect (10.0% [7/70]) or MvD-P (2.9% [2/70]). In a multivariable logistic regression analysis, male gender (odds ratio [OR], 3.96; P <0.001), worse VF MD (OR, 1.44; P =0.019), thinner global RNFL (OR, 1.13; P <0.001), higher prevalence of focal LC defect (OR, 3.71; P =0.014) and MvD-P (OR, 7.85; P <0.001) were significantly associated with MvD-D. CONCLUSIONS: MvD-D was related to worse disease severity in patients with PPG, and often was not accompanied by focal LC defect or MvD-P. This suggests that impaired optic disc circulation can be an early sign of glaucoma without noticeable changes in functional or structural features (i.e., VF, focal LC defect, MvD-P).


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Microvasos , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais , Humanos , Disco Óptico/irrigação sanguínea , Masculino , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Campos Visuais/fisiologia , Tomografia de Coerência Óptica/métodos , Pessoa de Meia-Idade , Microvasos/patologia , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Pressão Intraocular/fisiologia , Doenças do Nervo Óptico/diagnóstico , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Angiofluoresceinografia/métodos , Estudos Transversais
3.
Am J Ophthalmol ; 265: 224-235, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38703801

RESUMO

PURPOSE: To assess the relationship between the change of optic disc vessel density (ODVD) and retinal nerve fiber layer (RNFL) thinning in primary open-angle glaucoma (POAG) patients. DESIGN: Retrospective case series. METHODS: For 105 POAG patients, ≥5 consecutive optical coherence tomography (OCT) and OCT angiography images were obtained during ≥2 years of follow-up. Based on enface OCT angiography imaging, ODVD was calculated as the ratio of pixels occupied by vessels below the internal limiting membrane within the temporal area of the optic cup, and ODVD reduction was determined when there was a statistically significant negative slope (P < .05) for any of the global, superior, or inferior sectors. The association between the rates of ODVD change and RNFL thinning was assessed by a multivariable longitudinal linear mixed-effects model versus time. RESULTS: During 2.9 ± 0.3 years of follow-up on the 105 participants with visual field mean deviation at baseline of -5.7 ± 4.8 dB, 46 (43.8%) showed ODVD reduction. Faster global RNFL thinning was associated with the smaller Bruch's membrane opening area (ß = 0.381; 95% confidence interval [CI], 0.120-0.646; P = .006), optic disc hemorrhage (ß = -0.567; 95% CI, -0.909 to -0.228; P = .002), and faster rate of global ODVD change (ß = -0.090; 95% CI, -0.139 to -0.042; P = .001). CONCLUSIONS: Reduction of optic disc microvasculature was associated with rapid RNFL thinning in POAG. This suggests a role for deep optic nerve head circulation in the glaucoma pathogenesis.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Microvasos , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Vasos Retinianos , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Disco Óptico/irrigação sanguínea , Disco Óptico/patologia , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Estudos Retrospectivos , Fibras Nervosas/patologia , Feminino , Masculino , Células Ganglionares da Retina/patologia , Pessoa de Meia-Idade , Campos Visuais/fisiologia , Pressão Intraocular/fisiologia , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Seguimentos , Microvasos/patologia , Idoso , Angiofluoresceinografia/métodos , Testes de Campo Visual , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia
4.
J Glaucoma ; 33(Suppl 1): S26-S32, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38506792

RESUMO

PURPOSE: To provide an overview of novel technologies in telemedicine and artificial intelligence (AI) approaches for cost-effective glaucoma screening. METHODS/RESULTS: A narrative review was performed by summarizing research results, recent developments in glaucoma detection and care, and considerations related to telemedicine and AI in glaucoma screening. Telemedicine and AI approaches provide the opportunity for novel glaucoma screening programs in primary care, optometry, portable, and home-based settings. These approaches offer several advantages for glaucoma screening, including increasing access to care, lowering costs, identifying patients in need of urgent treatment, and enabling timely diagnosis and early intervention. However, challenges remain in implementing these systems, including integration into existing clinical workflows, ensuring equity for patients, and meeting ethical and regulatory requirements. Leveraging recent work towards standardized data acquisition as well as tools and techniques developed for automated diabetic retinopathy screening programs may provide a model for a cost-effective approach to glaucoma screening. CONCLUSION: Leveraging novel technologies and advances in telemedicine and AI-based approaches to glaucoma detection show promise for improving our ability to detect moderate and advanced glaucoma in primary care settings and target higher individuals at high risk for having the disease.


Assuntos
Inteligência Artificial , Glaucoma , Telemedicina , Humanos , Glaucoma/diagnóstico , Programas de Rastreamento/métodos
5.
Invest Ophthalmol Vis Sci ; 65(8): 18, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38980269

RESUMO

Purpose: To compare rates of retinal nerve fiber layer change over time in healthy, eyes with nonprogressing glaucoma and eyes with progressing glaucoma using single wide-field (SWF) and optic nerve head (ONH) cube scan optical coherence tomography (OCT) images. Methods: Forty-five eyes of 25 healthy individuals and 263 eyes of 161 glaucoma patients from the Diagnostic Innovations in Glaucoma Study were included. All eyes underwent 24-2 visual field testing and OCT (Spectralis SD-OCT) ONH and macular imaging. SWF images (up to 43° × 28°) were created by stitching together ONH cube scans centered on the optic disc and macular cube scans centered on the fovea. Visual field progression was defined as guided progression analysis likely progression and/or a significant (P < 0.01) mean deviation slope of less than -1.0 dB/year. Mixed effects models were used to compare rates of change. Highly myopic eyes were included. Results: Thirty glaucomatous eyes were classified as progressing. In eyes with glaucoma, mean global rate of change was -1.22 µm/year (P < 0.001) using SWF images and -0.83 µm/year (P = 0.003) using ONH cube scans. Rate of change was significantly greater in eyes with progressing glaucoma compared with eyes with nonprogressing glaucoma (-1.51 µm/year vs. -1.24 µm/year; P = 0.002) using SWF images and was similar using ONH cube scans (P = 0.27). Conclusions: In this cohort that includes eyes with and without high axial myopia, the mean rate of retinal nerve fiber layer thinning measured using SWF images was faster in eyes with progressing glaucoma than in eyes with nonprogressing glaucoma. Wide-field OCT images including the ONH and macula can be effective for monitoring glaucomatous progression in patients with and without high myopia.


Assuntos
Progressão da Doença , Glaucoma , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Pressão Intraocular/fisiologia , Idoso , Glaucoma/diagnóstico , Glaucoma/diagnóstico por imagem , Testes de Campo Visual , Adulto
6.
JAMA Ophthalmol ; 142(6): 530-537, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38696186

RESUMO

Importance: Rapid initial optic nerve head capillary density loss may be used to assess the risk of glaucoma visual field progression. Objective: To investigate the association between the rate of initial optic nerve head capillary density loss from optical coherence tomography angiography (OCTA) and visual field progression. Design, Setting, Participants: This was a retrospective study of a longitudinal cohort at a glaucoma referral center. A total of 167 eyes (96 with primary open-angle glaucoma and 71 with glaucoma suspect) of 109 patients were monitored for a mean (SD) of 5.7 (1.4) years from January 2015 to December 2022. Data analysis was undertaken in April 2023. Main Outcomes and Measures: The rates of initial capillary density and average retinal nerve fiber layer loss were calculated from the first 3 optic nerve head OCTA and OCT scans, respectively, during the initial follow-up (mean [SD], 2.0 [1.0] years). Based on the median rate, eyes were categorized into fast and slow progressor groups. The association between initial capillary density change or retinal nerve fiber layer thinning and visual field progression was evaluated using linear-mixed and time-varying Cox models. Results: A total of 167 eyes of 109 patients (mean [SD] age, 69.0 [11.1] years; 56 [51.4%] female and 53 [48.6%] male) were assessed. Eighty-three eyes were slow OCTA progressors, while 84 eyes were fast with mean capillary density loss of -0.45% per year and -1.17% per year, respectively (mean difference, -0.72%/year; 95% CI,-0.84 to -0.60; P < .001). Similarly, 83 eyes were slow OCT progressors, while 84 eyes were fast with mean retinal nerve fiber layer thinning of -0.09 µm per year and -0.60 µm per year, respectively (mean difference, -0.51 µm/year; 95% CI,-0.59 to -0.43; P < .001). The fast OCTA and OCT progressors were associated with more rapid visual field loss (mean difference, -0.18 dB/year; 95% CI,-0.30 to -0.06; P = .004 and -0.17 dB/year; 95% CI,-0.29 to -0.06; P = .002, respectively). Fast OCTA progressing eyes were more likely to have visual field progression (hazard ratio, 1.96; 95% CI, 1.04-3.69; P = .04). Seventeen of 52 eyes (32.7%; 95% CI, 32.5-32.8) with fast OCTA and OCT progression developed subsequent visual field likely progression. Conclusion and Relevance: Rapid initial optic nerve head capillary density loss from OCTA was associated with a faster rate of visual field progression and a doubling of the risk of developing event progression in this study. These findings may support clinical use of OCTA and OCT optic nerve head measurements for risk assessment of glaucoma progression.


Assuntos
Capilares , Progressão da Doença , Glaucoma de Ângulo Aberto , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Vasos Retinianos , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Campos Visuais/fisiologia , Feminino , Masculino , Disco Óptico/irrigação sanguínea , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Capilares/patologia , Capilares/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Pressão Intraocular/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Seguimentos , Testes de Campo Visual , Angiofluoresceinografia/métodos , Fatores de Risco , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/diagnóstico
7.
Am J Ophthalmol ; 266: 77-91, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754801

RESUMO

PURPOSE: To characterize structural differences and assess the diagnostic accuracy of optic nerve head (ONH) and macula optical coherence tomography (OCT) parameters to detect glaucoma in eyes with and without high axial myopia. DESIGN: Cross-sectional study. METHODS: Three hundred sixty-eight glaucoma and 411 healthy eyes with no axial myopia, 393 glaucoma and 271 healthy eyes with mild axial myopia and 124 glaucoma and 85 healthy eyes with high axial myopia were included. Global and sectoral peripapillary retinal nerve fiber layer thickness (pRNFLT), Bruch's membrane opening minimum rim width (BMO-MRW), ganglion cell inner plexiform layer thickness (GCIPLT), and macula RNFLT (mRNFLT) were compared and the diagnostic accuracy for glaucoma detection was evaluated using the adjusted area under the receiver operating characteristic curve (AUC). RESULTS: Diagnostic accuracy for ONH and macula parameters to detect glaucoma was generally high and differed by myopia group. For ONH parameters the diagnostic accuracy was highest for global (AUC = 0.95) and inferotemporal (AUC = 0.91) pRNFLT for high myopes and global BMO-MRW for nonmyopes (AUC = 1.0) and mild myopes (AUC = 0.97). For macula parameters, the diagnostic accuracy was higher in high myopes with 6 of the 11 GCIPLT global/sectors having adjusted AUCs > 0.90 compared to nonhigh myopes with no AUCs > 0.90. In all myopia groups, mRNFLT had lower AUCs than GCIPLT. CONCLUSIONS: The diagnostic accuracy for pRNFL and GCIPL was high for high axial myopic eyes and shows promise for glaucoma detection in high myopes. Further analysis is needed to determine whether the high diagnostic accuracy can be confirmed in other populations.

8.
Am J Ophthalmol ; 264: 104-119, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38579920

RESUMO

PURPOSE: To evaluate the association of mean intraocular pressure (IOP) and IOP variability (IOP fluctuation [SD of IOP] and the IOP range) with the rate of ganglion cell complex (GCC) layer thinning over time in patients with glaucoma. DESIGN: Prospective cohort study. METHODS: Participants with at least 4 visits and 2 years of follow-up of optical coherence tomography tests were included. A linear mixed-effect model was used to investigate the association of IOP parameters with the rates of GCC thinning. Subgroup analyses were conducted for eyes with early (MD ≥ -6 dB), and moderate to advanced stage (MD < -6 dB) at baseline. RESULTS: The cohort consisted of 369 eyes of 249 glaucoma patients (282 early glaucoma and 87 moderate to advanced glaucoma) with mean (standard deviation [SD]) age of 68.2 (10.7) years over 5.1 years of follow-up. The mean rate of GCC change was -0.59 (95% confidence interval [CI], -0.67 to -0.52) µm per year. In multivariable models, faster annual rate of GCC thinning was associated with a higher IOP fluctuation (-0.17 [95% CI, -0.23 to -0.11] µm per 1-mmHg higher, P < .001) or higher IOP range (-0.07 [95% CI, -0.09 to -0.05] µm per 1-mmHg higher, P < .001) after adjustment for mean IOP and other confounding factors. Similar results were found for early and moderate to advanced stages of glaucoma. CONCLUSIONS: IOP variability showed an independent association with macular change in patients with glaucoma regardless of severity at baseline, even after adjustment for mean IOP, supporting its potential value as a therapeutic target for clinical decision-making.


Assuntos
Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Tonometria Ocular , Campos Visuais , Humanos , Pressão Intraocular/fisiologia , Feminino , Masculino , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina/patologia , Idoso , Seguimentos , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Campos Visuais/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Progressão da Doença , Testes de Campo Visual
9.
Br J Ophthalmol ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839252

RESUMO

BACKGROUND/AIMS: To investigate the association between use of metformin and circumpapillary retinal nerve fibre layer (cpRNFL) thickness, as well as whole image capillary density (wiCD), in patients with glaucoma. METHODS: This cross-sectional study included patients with glaucoma suspect or primary open-angle glaucoma (POAG) underwent optical coherence tomography angiography imaging. Use and duration of antidiabetic medications were assessed at the time of imaging. Multivariable linear mixed-effect modelling was used to estimate the effect of diabetes medication on wiCD and cpRNFL while controlling for covariates including age, race, body mass index, diagnosis, 24-2 visual field mean deviation, and intraocular pressure, average signal strength index as well as any variables that showed a p <0.1 in the univariable analysis. RESULTS: A total of 577 eyes (330 POAG and 247 glaucoma suspect) of 346 patients were included. Sixty-five patients (23%) had diabetes, of whom 55 (78.5%) used metformin, and 17 (26.2%) used insulin. After adjusting for covariates, the association between metformin use and wiCD (1.56 (95% CI 0.40 to 2.71); p=0.008), duration of metformin use and wiCD (0.12 (95% CI 0.02 to 0.22) per 1 year longer; p=0.037), and metformin use and cpRNFL thickness (5.17 (95% CI 1.24 to 9.10) µm; p=0.010) had statistically significant associations in each model. CONCLUSIONS: Metformin use was associated with higher wiCD and thicker cpRNFL. These findings indicate a potential association, underscoring the need for longitudinal studies to determine if metformin plays a role in the retinal conditions of patients with glaucoma. TRIAL REGISTRATION NUMBER: NCT00221897.

10.
Am J Ophthalmol ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094992

RESUMO

PURPOSE: To examine the time to glaucoma progression detection by retinal nerve fiber layer thickness (RNFLT) and visual field (VF) among African descent (AD) individuals. DESIGN: Retrospective cohort study. METHODS: Setting: Multi-center. STUDY POPULATION: We included AD glaucoma eyes from DIGS/ADAGES with ≥2-year/5-visits of optic nerve head RNFLT and 24-2 VF examinations. Intervention or Observation Procedure: Rates of VF mean deviation (MD) and RNFLT worsening were analyzed using linear mixed-effects models, and longitudinal data was simulated using the variability estimates. MAIN OUTCOME MEASURE: The simulated time to detect trend-based glaucoma progression was assessed with assumed rates of VF MD and RNFLT change derived from the cohort (25th, 50th, 75th percentile [p25, median, p75] slopes and mean slopes). Severity-stratified analyses were also performed. RESULTS: We included 184 eyes from 128 AD subjects (mean baseline age: 63.4 years; VF MD: -4.2 dB, RNFLT: 80.2 µm). The p25, median, mean and p75 rates of change were -0.43, -1.01, -1.15 and -1.64 µm/year for RNFLT, and 0.00, -0.21, -0.30 and -0.51 dB/year for VF MD, respectively. Compared to VF MD, RNFLT showed an overall shorter mean time to progression detection (time difference: 0.4-1.7 years), with the mean rates showing the largest difference (RNFLT: 5.2 years vs. VF MD: 6.9 years). Similarly, we found an overall shorter time to detect RNFLT progression, compared to that of VF MD progression, in mild glaucoma eyes (≥1 year earlier) and in moderate-advanced glaucoma eyes (∼0.5 year earlier). CONCLUSIONS: Computer simulation showed potentially shorter time to detect RNFLT progression than VF MD progression in AD eyes. Our findings support the importance of using RNFLT to detect progressive glaucoma in AD individuals.

11.
Br J Ophthalmol ; 108(8): 1094-1100, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-38164556

RESUMO

BACKGROUND: To examine long-term retinal nerve fibre layer thickness (RNFLT) variability and associated clinical factors in African (AD) and European descent (ED) individuals with glaucoma. METHODS: This retrospective cohort study included glaucoma eyes of AD and ED from Diagnostic Innovations in Glaucoma Study/The African Descent and Glaucoma Evaluation Study with ≥4 visits/2 years of follow-up. We calculated optic nerve head RNFLT variability per-examination/visit as the absolute error of its residuals across follow-up. Full, baseline and parsimonious linear-mixed models were fit to evaluate the effects of clinical factors (demographics and ocular characteristics, prior/intervening glaucoma surgeries and cataract extraction (CE), RNFLT thinning rate, scan quality, visit/testing frequency, etc) on RNFLT variability in both races. RESULTS: There were 376 and 625 eyes (226 and 349 participants) of AD and ED, and the mean (95% CI) RNFLT variability was 1.62 (1.52, 1.71) µm and 1.42 (1.34, 1.50) µm, respectively (p=0.002). AD and ED had some shared predictors of RNFLT variability, including intraocular pressure fluctuation and scan quality, although the effects varied (p<0.05). In both races, intervening CE was most strongly correlated with higher RNFLT variability (ß: 0.24-0.92, p<0.05). After excluding eyes with intervening CE, RNFLT variability was reduced and the small racial difference was no longer significant (AD: 1.40 (1.31, 1.48) µm vs ED: 1.34 (1.27, 1.40) µm; p=0.280). CONCLUSIONS: Although some predictors were identified, long-term RNFLT variability appeared small for both AD and ED eyes. Moreover, the racial difference did not remain once intervening CE, the strongest predictor of variability, was eliminated. Our findings inform on strategies to optimise structural assessment and suggest that, when accounting for relevant factors, RNFLT is reliable across races.


Assuntos
Glaucoma , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , População Negra , Seguimentos , Glaucoma/etnologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Campos Visuais/fisiologia , População Branca/etnologia
12.
Br J Ophthalmol ; 108(8): 1101-1106, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-38164585

RESUMO

BACKGROUND/AIMS: To investigate the association between longitudinal changes of foveal avascular zone (FAZ) area and the rate of structural and functional progression in glaucoma. METHODS: A longitudinal cohort included 115 eyes (46 glaucoma suspect and 66 primary open-angle glaucoma) of 81 patients having ≥2 year follow-up, and ≥4 visits with optical coherence tomography angiography and visual field (VF). Eyes in the longitudinal cohort with a slope greater than that found in 95 percentile of separate healthy test-retest series for FAZ area were categorised into FAZ progressors; all other eyes were defined as FAZ non-progressors. A generalised linear mixed-effect model was used to investigate the association of FAZ progressors with demographic and clinical characteristics. RESULTS: Faster ganglion cell complex (GCC) thinning and faster VF mean deviation (MD) loss were found in eyes with FAZ progressors compared with FAZ non-progressors (mean difference: -0.7 (95% CI, -1.4 to -0.1) µm/y; p=0.026, -0.3 (-0.5 to -0.1) dB/y; p=0.017, respectively), while whole image vessel density was not associated with FAZ progressors (p=0.929). SD of intraocular pressure (IOP) and IOP range were also associated with FAZ progressors in separate multivariable models (OR: 1.54 (1.02 to 2.32) per 1 mm Hg higher, p=0.041; OR: 1.20 (1.01 to 1.41) per 1 mm Hg higher; p=0.035, respectively). CONCLUSIONS: Significant FAZ increase was weakly associated with moderately faster rates of both GCC thinning and VF MD loss, but not macular vessel density change in glaucoma eyes. Additional studies are needed to elucidate the pathophysiological associations between macula GCC thinning and FAZ area increases in glaucoma.


Assuntos
Progressão da Doença , Fóvea Central , Glaucoma de Ângulo Aberto , Pressão Intraocular , Células Ganglionares da Retina , Vasos Retinianos , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Campos Visuais/fisiologia , Fóvea Central/patologia , Fóvea Central/irrigação sanguínea , Fóvea Central/diagnóstico por imagem , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Idoso , Células Ganglionares da Retina/patologia , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiopatologia , Seguimentos , Angiofluoresceinografia/métodos , Fibras Nervosas/patologia , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/diagnóstico , Testes de Campo Visual
13.
Prog Retin Eye Res ; 99: 101246, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262557

RESUMO

Due to the increasing prevalence of high myopia around the world, structural and functional damages to the optic nerve in high myopia has recently attracted much attention. Evidence has shown that high myopia is related to the development of glaucomatous or glaucoma-like optic neuropathy, and that both have many common features. These similarities often pose a diagnostic challenge that will affect the future management of glaucoma suspects in high myopia. In this review, we summarize similarities and differences in optic neuropathy arising from non-pathologic high myopia and glaucoma by considering their respective structural and functional characteristics on fundus photography, optical coherence tomography scanning, and visual field tests. These features may also help to distinguish the underlying mechanisms of the optic neuropathies and to determine management strategies for patients with high myopia and glaucoma.


Assuntos
Glaucoma , Miopia , Disco Óptico , Doenças do Nervo Óptico , Humanos , Disco Óptico/patologia , Pressão Intraocular , Glaucoma/diagnóstico , Doenças do Nervo Óptico/patologia , Miopia/complicações , Miopia/diagnóstico , Tomografia de Coerência Óptica/métodos
14.
Transl Vis Sci Technol ; 13(1): 23, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38285462

RESUMO

Purpose: To develop and evaluate a deep learning (DL) model to assess fundus photograph quality, and quantitatively measure its impact on automated POAG detection in independent study populations. Methods: Image quality ground truth was determined by manual review of 2815 fundus photographs of healthy and POAG eyes from the Diagnostic Innovations in Glaucoma Study and African Descent and Glaucoma Evaluation Study (DIGS/ADAGES), as well as 11,350 from the Ocular Hypertension Treatment Study (OHTS). Human experts assessed a photograph as high quality if of sufficient quality to determine POAG status and poor quality if not. A DL quality model was trained on photographs from DIGS/ADAGES and tested on OHTS. The effect of DL quality assessment on DL POAG detection was measured using area under the receiver operating characteristic (AUROC). Results: The DL quality model yielded an AUROC of 0.97 for differentiating between high- and low-quality photographs; qualitative human review affirmed high model performance. Diagnostic accuracy of the DL POAG model was significantly greater (P < 0.001) in good (AUROC, 0.87; 95% CI, 0.80-0.92) compared with poor quality photographs (AUROC, 0.77; 95% CI, 0.67-0.88). Conclusions: The DL quality model was able to accurately assess fundus photograph quality. Using automated quality assessment to filter out low-quality photographs increased the accuracy of a DL POAG detection model. Translational Relevance: Incorporating DL quality assessment into automated review of fundus photographs can help to decrease the burden of manual review and improve accuracy for automated DL POAG detection.


Assuntos
Aprendizado Profundo , Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Fundo de Olho
15.
Am J Ophthalmol ; 266: 118-134, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38795748

RESUMO

PURPOSE: To apply retinal nerve fiber layer (RNFL) optical texture analysis (ROTA) to 1) investigate the association between papillomacular and papillofoveal bundle defects with 10-2 visual field (VF) sensitivity abnormalities, and 2) integrate the information from RNFL bundle defect and 24-2 VF central test locations to determine the likelihood of 10-2 VF sensitivity abnormalities. DESIGN: Cross-sectional. METHODS: A total of 841 eyes (144 healthy, 317 glaucoma suspect, and 380 glaucoma) of 442 participants were included. Eyes underwent 24-2, and 10-2 VF testing and OCT for ROTA. The borders of RNFL defects were delineated from ROTA, and the involvement of the arcuate, papillomacular, and papillofoveal bundles was determined for each eye. Multilevel logistic regression analysis was applied to evaluate the structure-function association. RESULTS: Papillomacular (92.1%) and papillofoveal (37.9%) RNFL bundle defects were prevalent in eyes with glaucoma. A 10-2 VF location that was projected onto a papillomacular or a papillofoveal RNFL bundle defect had a significantly increased likelihood of reduced sensitivity (ORs of 18.61 at PDP < 5%, and 20.17 at TDP < 5%, respectively, P < .001 for both). When predicting the likelihood of VF abnormality in a 10-2 test location, noticeably higher odds ratios were observed when overlapping with an RNFL bundle defect, compared to when an abnormal corresponding 24-2 central point was present. CONCLUSIONS: Papillomacular and papillofoveal RNFL bundle defects are present in a considerable proportion of eyes with glaucoma. When detected, they significantly increase the likelihood of abnormality in the corresponding central VF test locations assessed by the 10-2 test.

16.
Am J Ophthalmol ; 259: 7-14, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38708401

RESUMO

Purpose: To evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED). Design: Comparative diagnostic accuracy analysis by race. Participants: 379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Methods: Spectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other. Main Outcome Measures: Diagnostic accuracy of RNFLT measurements. Results: Diagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results. Conclusions: OCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , População Branca , Humanos , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/diagnóstico , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Campos Visuais/fisiologia , População Branca/etnologia , Reprodutibilidade dos Testes , Idoso , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etnologia , Negro ou Afro-Americano/etnologia , Área Sob a Curva , Sensibilidade e Especificidade
17.
Am J Ophthalmol ; 261: 141-164, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38311154

RESUMO

PURPOSE: To compare the prevalence, location and magnitude of optic nerve head (ONH) OCT-detected, exposed neural canal (ENC), externally oblique choroidal border tissue (EOCBT) and exposed scleral flange (ESF) regions in 122 highly myopic (Hi-Myo) versus 362 nonhighly myopic healthy (Non-Hi-Myo-Healthy) eyes. DESIGN: Cross-sectional study. METHODS: After OCT radial B-scan, ONH imaging, Bruch's membrane opening (BMO), the anterior scleral canal opening (ASCO), and the scleral flange opening (SFO) were manually segmented in each B-scan and projected to BMO reference plane. The direction and magnitude of BMO/ASCO offset and BMO/SFO offset as well as the location and magnitude of ENC, EOCBT and ESF regions, perineural canal (pNC) retinal nerve fiber layer thickness (RNFLT) and pNC choroidal thickness (CT) were calculated within 30° sectors relative to the Foveal-BMO (FoBMO) axis. Hi-ESF eyes were defined to be those with an ESF region ≥100 µms in at least 1 sector. RESULTS: Hi-Myo eyes more frequently demonstrated Hi-ESF regions (87/122) than Non-Hi-myo-Healthy eyes (73/362) and contained significantly larger ENC, EOCBT, and ESF regions (P < .001) which were greatest in magnitude and prevalence within the inferior-temporal FoBMO sectors where Hi-Myo pNC-RNFLT and pNCCT were thinnest. BMO/ASCO offset and the BMO/SFO offset were both significantly increased (P < .001) in the Hi-Myo eyes, with the latter demonstrating a greater increase. CONCLUSIONS: ENC region tissue remodeling that includes the scleral flange is enhanced in Hi-Myo compared to Non-Hi-Myo-Healthy eyes. Longitudinal studies are necessary to determine whether the presence of an ENC region influences ONH susceptibility to aging and/or glaucoma.


Assuntos
Miopia , Disco Óptico , Humanos , Disco Óptico/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Tubo Neural , Estudos Transversais , Miopia/diagnóstico , Lâmina Basilar da Corioide/anatomia & histologia , Pressão Intraocular
18.
Br J Ophthalmol ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39117359

RESUMO

BACKGROUND/AIMS: To design a deep learning (DL) model for the detection of glaucoma progression with a longitudinal series of macular optical coherence tomography angiography (OCTA) images. METHODS: 202 eyes of 134 patients with open-angle glaucoma with ≥4 OCTA visits were followed for an average of 3.5 years. Glaucoma progression was defined as having a statistically significant negative 24-2 visual field (VF) mean deviation (MD) rate. The baseline and final macular OCTA images were aligned according to centre of fovea avascular zone automatically, by checking the highest value of correlation between the two images. A customised convolutional neural network (CNN) was designed for classification. A comparison of the CNN to logistic regression model for whole image vessel density (wiVD) loss on detection of glaucoma progression was performed. The performance of the model was defined based on the confusion matrix of the validation dataset and the area under receiver operating characteristics (AUC). RESULTS: The average (95% CI) baseline VF MD was -3.4 (-4.1 to -2.7) dB. 28 (14%) eyes demonstrated glaucoma progression. The AUC (95% CI) of the DL model for the detection of glaucoma progression was 0.81 (0.59 to 0.93). The sensitivity, specificity and accuracy (95% CI) of DL model were 67% (34% to 78%), 83% (42% to 97%) and 80% (52% to 95%), respectively. The AUC (95% CI) for the detection of glaucoma progression based on the logistic regression model was lower than the DL model (0.69 (0.50 to 0.88)). CONCLUSION: The optimised DL model detected glaucoma progression based on longitudinal macular OCTA images showed good performance. With external validation, it could enhance detection of glaucoma progression. TRIAL REGISTRATION NUMBER: NCT00221897.

19.
Am J Ophthalmol ; 267: 257-270, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986858

RESUMO

PURPOSE: To evaluate the association between rates of juxtapapillary choriocapillaris microvasculature dropout (MvD) change and rates of ganglion cell inner plexiform layer (GCIPL) loss in primary open-angle glaucoma (POAG) and glaucoma suspect eyes with and without myopia. DESIGN: Cohort study from clinical trial data. METHODS: 238 eyes from 155 POAG and glaucoma suspect patients were stratified into no-myopia (axial length (AL) ≤ 24 mm; n = 78 eyes), mild myopia (24 mm < AL ≤ 26 mm; n = 114 eyes), and high myopia (AL > 26 mm; n = 46 eyes). Eyes with a minimum of 3 visits and 1.5 years of follow-up with both optical coherence tomography angiography (OCT-A) and OCT macula scans were included. Presence, area, and angular circumference of juxtapapillary MvD were evaluated on en face choroidal images and horizontal B-scans obtained from OCT-A imaging. RESULTS: Over the mean follow-up of 4.4 years, the mean MvD area rates of change (95% CI) were largest in high and mild myopia group (0.04 [0.03, 0.05] mm2/year in both groups), followed by the no-myopia group (0.03 [0.02, 0.04] mm2/year). The mean MvD angular circumference rates of change (95% CI) were highest in mild myopia group (8.7° [6.9°, 10.5°]/year) followed by the high myopia and no-myopia groups (8.1° [5.3°, 10.9°]/year, and 7.4° [5.3°, 9.6°]/year, respectively). While the mean global GCIPL thinning rates between eyes with MvD at baseline compared to eyes without were similar in all myopia groups, the rates of MvD area change were significantly faster in all myopia groups with baseline MvD (all p ≤ 0.004). Significant faster rates of MvD angular circumference change were found in the mild myopia group with baseline MvD (P < .001) only. In multivariable models, the rates of GCIPL thinning over time were significantly associated with rates of MvD angular circumference change and MvD area change (R2 = 0.33, P < .001 and R2 = 0.32, P = .006, respectively). CONCLUSIONS: Rates of GCIPL thinning were associated with rates of MvD area and angular circumference change over time in myopic POAG eyes. Utilizing OCT-A to detect MvD may provide an additional tool for monitoring macular structural changes in glaucomatous eyes with myopia.

20.
Am J Ophthalmol ; 257: 91-102, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37689330

RESUMO

PURPOSE: To investigate factors associated with the severity of prelaminar schisis (PLS) in heathy subjects and glaucoma patients. DESIGN: Prospective cross-sectional study. METHODS: A total of 217 eyes of 217 subjects (110 normal eyes and 107 open angle glaucoma eyes) were studied. Frequency and severity of PLS were compared between normal and glaucomatous eyes. Multivariate logistic models were used to assess factors associated with the severity of PLS. Factors considered were age, axial length, glaucomatous damage indices, Bruch membrane opening (BMO) and anterior scleral canal opening parameters, tractional forces (posterior vitreous staging and presence of Bergmeister papilla), circumpapillary choroidal thickness, lamina cribrosa (LC) parameters, and peripapillary scleral (PPS) angle. RESULTS: The frequency of PLS was 70.9% in normal eyes and 72.0% in glaucomatous eyes. There was no difference in frequency and severity between the groups. The presence of Bergmeister papilla was the strongest predictor of a more severe PLS in both normal and glaucomatous eyes (odds ratio [OR] + 9.78, 12.5; both P < .001). A larger PPS angle in normal eyes (OR = 1.19; P = .003) and a larger BMO area and a deeper LC depth in glaucomatous eyes (OR = 1.08, 1.05; both P = .038) were associated with severity of PLS. CONCLUSIONS: The severity of PLS was strongly associated with the presence of Bergmeister papilla, suggesting a traction-related phenomenon. Correlation of PLS severity with larger BMO area and deeper LC depth, which are optic nerve head structures associated with glaucoma, suggested its possible relationship with glaucomatous damage.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Vítreo Primário Hiperplásico Persistente , Humanos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Transversais , Estudos Prospectivos , Tomografia de Coerência Óptica , Glaucoma/complicações , Glaucoma/diagnóstico , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA