2.
Circ Res ; 105(11): 1128-40, 2009 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-19815820

RESUMO

RATIONALE: Chronic rejection, accelerated coronary atherosclerosis, myocardial infarction, and ischemic heart failure determine the unfavorable evolution of the transplanted heart in humans. OBJECTIVE: Here we tested whether the pathological manifestations of the transplanted heart can be corrected partly by a strategy that implements the use of cardiac progenitor cells from the recipient to repopulate the donor heart with immunocompatible cardiomyocytes and coronary vessels. METHODS AND RESULTS: A large number of cardiomyocytes and coronary vessels were created in a rather short period of time from the delivery, engraftment, and differentiation of cardiac progenitor cells from the recipient. A proportion of newly formed cardiomyocytes acquired adult characteristics and was integrated structurally and functionally within the transplant. Similarly, the regenerated arteries, arterioles, and capillaries were operative and contributed to the oxygenation of the chimeric myocardium. Attenuation in the extent of acute damage by repopulating cardiomyocytes and vessels decreased significantly the magnitude of myocardial scarring preserving partly the integrity of the donor heart. CONCLUSIONS: Our data suggest that tissue regeneration by differentiation of recipient cardiac progenitor cells restored a significant portion of the rejected donor myocardium. Ultimately, immunosuppressive therapy may be only partially required improving quality of life and lifespan of patients with cardiac transplantation.


Assuntos
Rejeição de Enxerto/patologia , Transplante de Coração , Histocompatibilidade , Miócitos Cardíacos/citologia , Regeneração/imunologia , Células-Tronco/citologia , Animais , Sequência de Bases , Diferenciação Celular/fisiologia , Fusão Celular , Vasos Coronários/citologia , Cães , Feminino , Genótipo , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/imunologia , Proteínas de Fluorescência Verde/genética , Insuficiência Cardíaca/imunologia , Insuficiência Cardíaca/patologia , Imunossupressores/uso terapêutico , Masculino , Dados de Sequência Molecular , Miocárdio/patologia , Células-Tronco/fisiologia
3.
Eur J Cardiothorac Surg ; 60(3): 579-587, 2021 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-33871594

RESUMO

OBJECTIVES: The HeartWare HVAD (HW) and the HeartMate3 (HM3) are presently the most commonly used continuous-flow left ventricular assist devices worldwide. We compared the outcomes of patients supported with either of these 2 devices based on data from the EUROMACS (European Registry for Patients with Mechanical Circulatory Support). METHODS: A retrospective analysis of the survival and complications profile in propensity score-matched adult patients enrolled in the EUROMACS between 01 January 2016 and 01 September 2020 and supported with either an HW or HM3. Matching included demographic parameters, severity of cardiogenic shock and risk-modifying end-organ parameters that impact long-term survival. Survival on device and major postoperative adverse events were analysed. RESULTS: Following 1:1 propensity score matching, each group consisted of 361 patients. Patients were well balanced (<0.1 standardized mean difference). The median follow-up was similar in both groups [396 (interquartile range (IQR) 112-771) days for HW and 376 (IQR 100-816) days for HM3]. The 2-year survival was similar in both groups [HW: 61% 95% confidence interval (CI) (56-67%) vs HM3: 68% 95% CI (63-73%) (stratified hazard ratio for mortality: 1.13 95% CI (0.83-1.54), P = 0.435].The cumulative incidence for combined major adverse events and unexpected readmissions was similar in both groups [subdistribution hazard ratio (SHR) 1.0 (0.84-1.21), P = 0.96]. Patients in the HW group demonstrated a higher risk of device malfunction [SHR 2.44 (1.45-3.71), P < 0.001], neurological dysfunction [SHR 1.29 (1.02-1.61), P = 0.032] and intracranial bleeding [SHR 1.76 (1.13-2.70), P = 0.012]. CONCLUSIONS: Mid-term survival in both groups was similar in a propensity-matched analysis. The risk of device malfunction, neurological dysfunction and intracranial bleeding was significantly higher in HW patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Seguimentos , Coração Auxiliar/efeitos adversos , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
4.
Heart Rhythm ; 18(2): 303-312, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33045430

RESUMO

The absence of strategies to consistently and effectively address nonparoxysmal atrial fibrillation by nonpharmacological interventions has represented a long-standing treatment gap. A combined epicardial/endocardial ablation strategy, the hybrid Convergent procedure, was developed in response to this clinical need. A subxiphoid incision is used to access the pericardial space facilitating an epicardial ablation directed at isolation of the posterior wall of the left atrium. This is followed by an endocardial ablation to complete isolation of the pulmonary veins and for additional ablation as needed. Experience gained with the hybrid Convergent procedure during the last decade has led to the development and adoption of strategies to optimize the technique and mitigate risks. Additionally, a surgical and electrophysiology "team" approach including comprehensive training is believed critical to successfully develop the hybrid Convergent program. A recently completed randomized clinical trial indicated that this ablation strategy is superior to an endocardial-only approach for patients with persistent atrial fibrillation. In this review, we propose and describe best practice guidelines for hybrid Convergent ablation on the basis of a combination of published data, author consensus, and expert opinion. A summary of clinical outcomes, emerging evidence, and future perspectives is also given.


Assuntos
Fibrilação Atrial/cirurgia , Endocárdio/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Pericárdio/cirurgia , Guias de Prática Clínica como Assunto , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Humanos , Recidiva
5.
Interact Cardiovasc Thorac Surg ; 28(3): 478-480, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30239891

RESUMO

Less-invasive left ventricular assist device implantation is becoming the technique of choice for implementation of new-generation heart pumps. The less-invasive technique is particularly useful for patients with a history of cardiac surgical procedures, such as coronary artery bypass grafting. Yet, in redo cases, severe pericardial adhesions may force experienced operators to opt for alternative outflow graft placement, such as in the descending aorta. We propose a surgical technique in which the left ventricular device is implanted through a limited thoracic incision, with the outflow graft anastomosed to the ascending aorta, avoiding collision with coronary bypass grafts. The key element of the proposed technique is a tunnel connecting 2 pleural cavities, in which the outflow graft is placed, entirely bypassing the pericardium.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Toracotomia/métodos , Aorta Torácica/cirurgia , Doença da Artéria Coronariana/complicações , Insuficiência Cardíaca/complicações , Ventrículos do Coração , Humanos
6.
JACC Cardiovasc Interv ; 11(14): 1368-1374, 2018 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-30025731

RESUMO

OBJECTIVES: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions. BACKGROUND: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far. METHODS: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure. RESULTS: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients. CONCLUSIONS: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Estimulação Cardíaca Artificial , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
EuroIntervention ; 13(15): e1764-e1770, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-29131801

RESUMO

AIMS: The aim of the SAVI TF registry was to assess the safety and performance of the self-expanding ACURATE neo transfemoral transcatheter heart valve in a large patient population with severe aortic stenosis and to investigate whether the outcomes obtained in the CE-mark cohort can be replicated in an unselected all-comers population. METHODS AND RESULTS: From October 2014 until April 2016, 1,000 patients were enrolled in this prospective, European multicentre registry. Patients were 81.1±5.2 years and had a logistic EuroSCORE II and STS score of 6.6±7.5% and 6.0±5.6%, respectively. Predilatation was performed in 96.1% of patients and postdilatation in 44.8%. Procedural and device success were both obtained in 98.7%; failure comprised nine valve-in-valve procedures, three conversions to surgery, and one aborted procedure. The primary endpoint was 30-day mortality, which was observed in 14 patients (1.4% [95% CI: 0.7-2.1]). Disabling stroke was seen in 1.2% (95% CI: 0.5-1.9) and new pacemaker implantation in 8.3% (95% CI: 6.6-10.0). At discharge, mean effective orifice area was 1.77±0.46 cm² and mean gradient 8.4±4.0 mmHg; 4.1% of patients had a more than mild paravalvular leak. CONCLUSIONS: In this initial experience, treatment with the ACURATE neo prosthesis resulted in good clinical outcomes with very low complication rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Valvuloplastia com Balão , Estimulação Cardíaca Artificial , Cateterismo Periférico/métodos , Avaliação da Deficiência , Europa (Continente)/epidemiologia , Feminino , Artéria Femoral , Humanos , Masculino , Marca-Passo Artificial , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
J Thorac Cardiovasc Surg ; 147(4): 1411-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23988287

RESUMO

BACKGROUND: The objective of this collaborative, multicenter, European effort was to evaluate the outcomes of the convergent procedure for the treatment of persistent and long-standing persistent atrial fibrillation (AF) in consecutive patients at 4 European centers. METHODS: Outcomes of consecutive patients, undergoing the convergent procedure at 4 European centers, were evaluated in this study. Epicardial ablation was performed before endocardial ablation. Convergent procedure outcomes were recorded by interrogation of implanted loop recorders or Holter monitors. Rhythm status and required interventions (antiarrhythmic drugs, cardioversions, and repeat ablations) were quantified 6 and 12 months after the procedure. Outcomes, monitoring type, and patient baseline characteristics were analyzed and reported. RESULTS: Seventy-three consecutive patients presenting with persistent AF (30.1%) or long-standing persistent AF (69.9%) underwent the convergent procedure between January 2010 and December 2011. At 6 months, 82% (56/68) were in sinus rhythm. At 12 months, 80% (53/66) were in sinus rhythm; single-procedure maintenance of sinus rhythm without postblanking period interventions was 76% (50/66); 52% (34/66) were in sinus rhythm and not receiving antiarrhythmic drugs. CONCLUSIONS: This multicenter European collaborative effort demonstrated that the convergent procedure is a safe and efficacious treatment option for persistent and long-standing persistent AF.


Assuntos
Fibrilação Atrial/cirurgia , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
J Thorac Dis ; 5 Suppl 6: S704-12, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24251031

RESUMO

Atrial fibrillation (AF) remains the most common cardiac arrhythmia, affecting nearly 2% of the general population worldwide. Minimally invasive surgical ablation remains one of the most dynamically evolving fields of modern cardiac surgery. While there are more than a dozen issues driving this development, two seem to play the most important role: first, there is lack of evidence supporting percutaneous catheter based approach to treat patients with persistent and long-standing persistent AF. Paucity of this data offers surgical community unparalleled opportunity to challenge guidelines and change indications for surgical intervention. Large, multicenter prospective clinical studies are therefore of utmost importance, as well as honest, clear data reporting. Second, a collaborative methodology started a long-awaited debate on a Heart Team approach to AF, similar to the debate on coronary artery disease and transcatheter valves. Appropriate patient selection and tailored treatment options will most certainly result in better outcomes and patient satisfaction, coupled with appropriate use of always-limited institutional resources. The aim of this review, unlike other reviews of minimally invasive surgical ablation, is to present medical professionals with two distinctly different, approaches. The first one is purely surgical, Standalone surgical isolation of the pulmonary veins using bipolar energy source with concomitant amputation of the left atrial appendage-a method of choice in one of the most important clinical trials on AF-The Atrial Fibrillation Catheter Ablation Versus Surgical Ablation Treatment (FAST) Trial. The second one represents the most complex approach to this problem: a multidisciplinary, combined effort of a cardiac surgeon and electrophysiologist. The Convergent Procedure, which includes both endocardial and epicardial unipolar ablation bonds together minimally invasive endoscopic surgery with electroanatomical mapping, to deliver best of the two worlds. One goal remains: to help those in urgent need for everlasting relief.

13.
Eur J Cardiothorac Surg ; 43(3): 541-8; discussion 548, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22619318

RESUMO

OBJECTIVES: Left main disease (LMD), combined with carotid artery stenosis (CAS), constitutes a high-risk patient population. Priority is often given to coronary revascularization, due to the severity of the angina. However, the choice of revascularization strategy [off-pump coronary artery bypass (OPCAB) vs coronary artery bypass grafting (CABG)] remains elusive. METHODS: A total of 1340 patients with LMD were non-randomly assigned to either on-pump (CABG group, n = 680) or off-pump (OPCAB group, n = 634) revascularization between 1 January 2006 and 21 September 2010. Multivariable regression was used to determine the risk-adjusted impact of a revascularization strategy on a composite in-hospital outcome (MACCE), and proportional hazards regression was used to define the variables affecting long-term survival. RESULTS: Significant CAS was found in 130 patients: 84 (13.1%) patients underwent OPCAB, while 46 patients (6.8%) underwent CABG (P < 0.05). Patients with a history of stroke/transient ischaemic attack were also more likely to receive OPCAB (7.1 vs 4.7%; P = 0.08). OPCAB patients were older, in a higher New York Heart Association (NYHA) class, with a lower LVEF and higher EuroSCORE. A calcified aorta was found in 79 patients [OPCAB-CABG: 49 (7.73%) vs 30 (4.41%); P = 0.016] and resulted in a less complex revascularization (OPCAB-CABG: 2.3 ± 0.71 vs 3.19 ± 0.82; P < 0.05), and 30-day mortality was insignificantly higher in the CABG (2.7 vs 2.8%) as well as MACCE (11.2 vs 12.2%; P = NS). This trend reversed when late mortality was evaluated; however, it did not reach significance at 60 months. Preoperative renal impairment requiring dialysis was found to be a technique-independent predictor of MACCE. The number of arterial conduits also influenced MACCE. CONCLUSIONS: Off-pump coronary revascularization may offer risk reduction of neurological complications in patients with a significant carotid artery disease and a history of previous stroke, but a larger study population is needed to support this thesis. The growing discrepancy in long-term survival should draw attention to a more complete revascularization in OPCAB patients.


Assuntos
Estenose das Carótidas/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Idoso , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/normas , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/normas , Feminino , Humanos , Ataque Isquêmico Transitório/fisiopatologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Estatísticas não Paramétricas , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA