Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artif Organs ; 46(11): 2179-2190, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35730930

RESUMO

BACKGROUND: Ex vivo lung perfusion (EVLP), is a platform that allows simultaneous testing and treatment of the lungs. However, use of EVLP is costly and requires access to lab animals and accompanying facilities. To increase the use of EVLP for research, we developed a method to perform EVLP using abattoir procured lungs. Furthermore, we were also able to significantly decrease costs. METHODS: Six pair of lungs were procured from abattoir sheep. The lungs were then flushed and stored in ice for 3 h. A low-flow (20% of cardiac output) approach, a tidal volume of 6 ml/kg bodyweight and total perfusion time of 3 h were chosen. Perfusion fluids and circuits were self-made. Lung biopsies, perfusate collection, respiratory values, circulatory pressures were recorded and hourly blood gas analyses were performed. RESULTS: Mean pO2 remained stable from 60 min (49.3 ± 7.1 kPa) to 180 min (51.5 kPa ± 8.0), p = 0.66. Pulmonary artery pressure remained ≤15 mm Hg and the left atrial pressure remained between 3 and 5 mm Hg and peak respiratory pressures ≤20 cmH2 O. Lactate dehydrogenase increased from start (96.3 ± 56.4 U/L) to the end of perfusion (315.8 ± 85.0 U/L), p < 0.05. No difference was observed in ATP between procurement and post-EVLP, 129.7 ± 37.4 µmol/g protein to 132.0 ± 23.4 µmol/g, p = 0.92. CONCLUSIONS: Sheep lungs, acquired from an abattoir, can be ex vivo perfused under similar conditions as lab animal lungs with similar results regarding e.g., oxygenation and ATP restoration. Furthermore, costs can be significantly reduced by making use of this abattoir model. By increasing accessibility and lowering costs for experiments using lung perfusion, more results may be achieved in the field of lung diseases.


Assuntos
Transplante de Pulmão , Ovinos , Animais , Transplante de Pulmão/métodos , Matadouros , Pulmão/irrigação sanguínea , Perfusão/métodos , Modelos Animais de Doenças , Trifosfato de Adenosina
2.
Transplantation ; 107(1): e3-e10, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36042552

RESUMO

BACKGROUND: The hemodynamic effects of aortic arch vessel (AAV) clamping during normothermic regional perfusion (NRP) in donation after circulatory death is unknown. We investigated effects of AAV clamping during NRP compared with no clamping in a porcine model. METHODS: In 16 pigs, hemodynamic parameters were recorded including biventricular pressure-volume measurements and invasive blood pressure. Additionally, blood gas parameters and inflammatory cytokines were used to assess the effect of AAV clamping. The animals were centrally cannulated for NRP, and baseline measurements were obtained before hypoxic circulatory arrest was induced by halting mechanical ventilation. During an 8-min asystole period, the animals were randomized to clamp (n = 8) or no-clamp (n = 8) of the AAV before commencement of NRP. During NRP, circulation was supported with norepinephrine (NE) and dobutamine. After 30 min of NRP, animals were weaned and observed for 180 min post-NRP. RESULTS: All hearts were successfully reanimated and weaned from NRP. The nonclamp groups received significantly more NE to maintain a mean arterial pressure >60 mm Hg during and after NRP compared with the clamp group. There were no between group differences in blood pressure or cardiac output. Pressure-volume measurements demonstrated preserved cardiac function' including ejection fraction and diastolic and systolic function. No between group differences in inflammatory markers were observed. CONCLUSIONS: AAV clamping did not negatively affect donor cardiac function or inflammation after circulatory death and NRP. Significantly less NE was used to support in the clamp group than in the nonclamp group.


Assuntos
Parada Cardíaca , Preservação de Órgãos , Animais , Aorta Torácica , Morte , Perfusão/efeitos adversos , Suínos , Coleta de Tecidos e Órgãos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA