Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 19(12): 11106-13, 2011 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-21716339

RESUMO

Periodically poled crystal (PPC) is a key component for nonlinear optical applications. Its poling quality relies largely on successful domain inversion and the alignment of spontaneous polarization (SP) vectors in each domain. Here we report the unexpected observation of bulk second harmonic generation (SHG) in PPC when excitation propagating along its optical axis. Based on its tensorial nature, SHG is highly sensitive to the orientation of SP, and therefore the misalignment of SP in each domain of PPC can be revealed noninvasively by SHG microscopy. This nonlinear imaging modality provides optical sectioning capability with 3D sub-micrometer resolution, so it will be useful for in situ investigation of poling quality in PPC.

2.
J Struct Biol ; 171(1): 88-94, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20206272

RESUMO

We present a new method, second harmonic generation (SHG) imaging for the study of starch structure. SHG imaging can provide the structural organization and molecular orientation information of bio-tissues without centrosymmetry. In recent years, SHG has proven its capability in the study of crystallized bio-molecules such as collagen and myosin. Starch, the most important food source and a promising future energy candidate, has, for a decade, been shown to exhibit strong SHG response. By comparing SHG intensity from different starch species, we first identified that the SHG-active molecule is amylopectin, which accounts for the crystallinity in starch granules. With the aid of SHG polarization anisotropy, we extracted the complete χ((2)) tensor of amylopectin, which reflects the underlying molecular details. Through χ((2)) tensor analysis, three-dimensional orientation and packing symmetry of amylopectin are determined. The helical angle of the double-helix in amylopectin is also deduced from the tensor, and the value corresponds well to previous X-ray studies, further verifying amylopectin as SHG source. It is noteworthy that the nm-sized structure of amylopectin inside a starch granule can be determined by this far-field optical method with 1-µm excitation wavelength. Since SHG is a relatively new tool for plant research, a detailed understanding of SHG in starch structure will be useful for future high-resolution imaging and quantitative analyses for food/energy applications.


Assuntos
Amilopectina/química , Imageamento Tridimensional/métodos , Amilose/química , Anisotropia , Microscopia Confocal/métodos , Óptica e Fotônica , Oryza/química , Amido/química
3.
Rev Sci Instrum ; 80(11): 113704, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19947734

RESUMO

Diversified research interests in scanning laser microscopy nowadays require broadband capability of the optical system. Although an all-mirror-based optical design with a suitable metallic coating is appropriate for broad-spectrum applications from ultraviolet to terahertz, most researchers prefer lens-based scanning systems despite the drawbacks of a limited spectral range, ghost reflection, and chromatic aberration. One of the main concerns is that the geometrical aberration induced by off-axis incidence on spherical mirrors significantly deteriorates image resolution. Here, we demonstrate a novel geometrical design of a spherical-mirror-based scanning system in which off-axis aberrations, both astigmatism and coma, are compensated to reach diffraction-limited performance. We have numerically simulated and experimentally verified that this scanning system meets the Marechal condition and provides high Strehl ratio within a 3 degrees x 3 degrees scanning area. Moreover, we demonstrate second-harmonic-generation imaging from starch with our new design. A greatly improved resolution compared to the conventional mirror-based system is confirmed. This scanning system will be ideal for high-resolution linear/nonlinear laser scanning microscopy, ophthalmoscopic applications, and precision fabrications.


Assuntos
Microscopia Confocal/instrumentação , Espalhamento de Radiação , Fenômenos Ópticos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA