Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Gastroenterol ; 57(8): 798-803, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997700

RESUMO

INTRODUCTION: Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. METHODS: We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. RESULTS: A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. CONCLUSIONS: The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Duodenoscópios/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos
2.
Endosc Int Open ; 11(5): E529-E537, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37251793

RESUMO

Background and study aims Endoscopic ultrasound-directed transgastric ERCP (EDGE) is a safe and efficacious procedure to treat pancreaticobiliary diseases in Roux-en-Y gastric bypass (RYGB). This multicenter study aimed to determine the long-term outcomes of EDGE focusing on fistula persistence rates and post-procedure weight change. Patients and methods Information about patients with Roux-en-Y gastric bypass anatomy who underwent EDGE between 2015 and 2021 from 10 institutions was captured in a registry. Patient demographics, procedural details, and clinical outcomes were analyzed. Results One hundred seventy-two patients were included in the study (mean age 60, 25 % male). Technical success of lumen-apposing metal stent (LAMS) placement was 171 of 172 (99.4 %) while clinical success of intervention was 95%. The mean procedure time was 65 minutes. The most commonly reported complication was stent dislodgement/migration (n = 29, 17). Mean length of time of LAMS duration was 69 days. Mean follow-up time was 6 months. Endoscopic fistula closure was performed in 40 % of patients (69/172) at the time of LAMS removal. Persistence of fistula was observed in 19 of 62 patients (31 %) assessed. Length of LAMS indwell time (days) was a predictor of persistent fistula. The average weight gain while the LAMS was in place was 12 lb in 63 patients (36.6 %); 59.4 % of patients gained < 5 lb. Conclusions EDGE is a safe and efficacious procedure for RYGB patients requiring ERCP. Post-procedure evaluation and management of the enteral fistula varies widely among centers currently and would benefit from further standardization. Fistula persistence appears to be uncommon and can be managed endoscopically but may be related to length of indwell times of the LAMS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA