Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Anaesth ; 130(1): e169-e178, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34895719

RESUMO

BACKGROUND: Patient-ventilator asynchrony during mechanical ventilation may exacerbate lung and diaphragm injury in spontaneously breathing subjects. We investigated whether subject-ventilator asynchrony increases lung or diaphragmatic injury in a porcine model of acute respiratory distress syndrome (ARDS). METHODS: ARDS was induced in adult female pigs by lung lavage and injurious ventilation before mechanical ventilation by pressure assist-control for 12 h. Mechanically ventilated pigs were randomised to breathe spontaneously with or without induced subject-ventilator asynchrony or neuromuscular block (n=7 per group). Subject-ventilator asynchrony was produced by ineffective, auto-, or double-triggering of spontaneous breaths. The primary outcome was mean alveolar septal thickness (where thickening of the alveolar wall indicates worse lung injury). Secondary outcomes included distribution of ventilation (electrical impedance tomography), lung morphometric analysis, inflammatory biomarkers (gene expression), lung wet-to-dry weight ratio, and diaphragmatic muscle fibre thickness. RESULTS: Subject-ventilator asynchrony (median [interquartile range] 28.8% [10.4] asynchronous breaths of total breaths; n=7) did not increase mean alveolar septal thickness compared with synchronous spontaneous breathing (asynchronous breaths 1.0% [1.6] of total breaths; n=7). There was no difference in mean alveolar septal thickness throughout upper and lower lung lobes between pigs randomised to subject-ventilator asynchrony vs synchronous spontaneous breathing (87.3-92.2 µm after subject-ventilator asynchrony, compared with 84.1-95.0 µm in synchronised spontaneous breathing;). There were also no differences between groups in wet-to-dry weight ratio, diaphragmatic muscle fibre thickness, atelectasis, lung aeration, or mRNA expression levels for inflammatory cytokines pivotal in ARDS pathogenesis. CONCLUSIONS: Subject-ventilator asynchrony during spontaneous breathing did not exacerbate lung injury and dysfunction in experimental porcine ARDS.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Traumatismos Torácicos , Animais , Feminino , Alvéolos Pulmonares , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/terapia , Suínos , Ventiladores Mecânicos
2.
Front Pediatr ; 10: 866111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35692973

RESUMO

Reliable testing methods for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in children are essential to allow normal activities. Diagnosis of SARS-CoV-2 infection is currently based on real-time reverse transcriptase-polymerase chain reaction (RT-PCR) performed on nasopharyngeal (NP) swabs; concerns have been raised regarding NP swab accuracy in children to detect the virus because of potential lack of cooperation of the patients or due to general uncertainties about concordance between high and low respiratory tract specimens in children. The aim of the study (IRB approval: ST/2020/405) is to prospectively compare RT-PCR results on NP and tracheo-bronchial aspirate (TA) in children admitted to the hospital for surgery or admitted to the Pediatric Intensive Care Unit (PICU) of a tertiary children hospital in Milano, Italy, during a peak of COVID-19 infections in the city. A total of 385 patients were enrolled in the study: 364 from surgical theater and 21 from PICU. Two patients (0.5%) tested positive on TA and were negative on NP; both cases occurred in November 2020, during a peak of infection in the city. Specificity of NP swab was.995 (95% CI: 0.980-0.999). Two patients with positive NP swabs tested negative on TA. Conclusion: Our study shows that the specificity of SARS-CoV-2 RT-PCR on TA swab, compared to results of SARS-CoV-2 RT-PCR on NP, was very high for negative cases in our pediatric cohort during a period of high epidemiological pressure.

3.
Children (Basel) ; 9(4)2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35455535

RESUMO

The aim of this study was to understand the epidemiology, disease severity, and microbiology of bronchiolitis in Italy during the 2021-2022 cold season, outside of lockdowns. Before COVID-19, the usual bronchiolitis season in Italy would begin in November and end in April, peaking in February. We performed a prospective observational study in four referral pediatric centers located in different geographical areas in Italy (two in the north, one in the center and one in the south). From 1 July 2021 to 31 January 2022, we collected all new clinical diagnoses of bronchiolitis in children younger than two years of age recording demographic, clinical and microbiological data. A total of 657 children with a clinical diagnosis of bronchiolitis were enrolled; 56% children were admitted and 5.9% required PICU admission. The first cases were detected during the summer, peaking in November 2021 and declining into December 2021 with only a few cases detected in January 2022. RSV was the commonest etiological agent, while SARS-CoV-2 was rarely detected and only since the end of December 2021. Disease severity was similar in children with RSV vs. non-RSV bronchiolitis, and in those with a single infectious agent detected compared with children with co-infections. The 2021-2022 bronchiolitis season in Italy started and peaked earlier than the usual pre-pandemic seasons, but had a shorter duration. Importantly, the current bronchiolitis season was not more severe when data were compared with Italian published data, and SARS-CoV-2 was rarely a cause of bronchiolitis in children younger than 24 months of age.

4.
Respir Care ; 60(12): 1777-85, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26420898

RESUMO

BACKGROUND: CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. METHODS: A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. RESULTS: The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. CONCLUSIONS: Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Serviços Médicos de Emergência/métodos , Máscaras , Oxigenoterapia/instrumentação , Pressão do Ar , Fluxo Expiratório Forçado , Humanos , Modelos Teóricos , Consumo de Oxigênio , Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA