Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 93(2): 208-215, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30298593

RESUMO

OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM). BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed. METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points. RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation. CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Stents Metálicos Autoexpansíveis , Sirolimo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Ligas , Fármacos Cardiovasculares/efeitos adversos , Pesquisa Comparativa da Efetividade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
J Invasive Cardiol ; 30(8): 283-288, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29760284

RESUMO

OBJECTIVE: To evaluate the outcome of patients undergoing PCI for unprotected left main coronary artery (ULMCA) disease with different drug-eluting stent (DES) types. BACKGROUND: Published literature suggests that second-generation DES options have differing vascular responses and outcomes, but there is a paucity of data in real-life patients in the LM setting. METHODS: This is a retrospective, multicenter study, including patients treated with a second-generation DES for ULMCA disease between 2007 and 2015. The primary endpoint was target-lesion revascularization (TLR). Secondary endpoints were major adverse cardiac events, myocardial infarction (MI), and stent thrombosis (ST). RESULTS: A total of 1209 patients were enrolled; 840 patients (69.5%) received an everolimus-eluting stent (EES), 133 patients (11.0%) received a zotarolimus-eluting stent (ZES), and 236 patients (19.5%) received a biodegradable polymer, biolimus-eluting stent (BP-BES). During a mean follow-up of 722 ± 640 days, TLR occurred in 47 patients (3.8%). At univariate analysis, EES patients had a lower TLR rate (3.6% vs 4.5% in ZES vs 4.2% in BP-BES), which was statistically significant at multivariate analysis (hazard ratio, 0.50; 95% confidence interval, 0.27-0.93; P=.03). No differences in major adverse cardiac events, death, MI, or ST were observed between groups. CONCLUSION: The safety profile of the stents used was comparable over the follow-up period. However, EES patients had lower restenosis rates, with a reduced need for repeat PCI.


Assuntos
Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Am J Cardiol ; 119(7): 978-982, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28131320

RESUMO

Incidence, predictors, and impact on prognosis of target lesion revascularization (TLR) for patients treated with second-generation drug-eluting stents (DESs) on unprotected left main (ULM) remain to be defined. The present study is a multicenter study including patients treated with a second-generation DES on ULM from June 2007 to January 2015. Rate of TLR was the primary end point. All cause death, myocardial infarction, target vessel revascularization, and stent thrombosis were the secondary end points. A total of 1,270 patients were enrolled: after a follow-up of 650 days (230 to 1,170), 47 (3.7%) of them underwent a re-percutaneous coronary intervention TLR on the left main, 22 during a planned angiographic follow-up. Extent of coronary artery disease was similar among groups (median value of Syntax of 27 ± 10 vs 26 ± 9, p = 0.45), as localization of the lesion in the ULM. Of patients reporting with TLR on ULM, 56% presented with a focal restenosis, 33% diffuse and 10% proliferative. At multivariate analysis, insulin-dependent diabetes mellitus increased risk of TLR (hazard ratio [HR] 2.0: 1.1 to 3.6, p = 0.04), whereas use of intravascular ultrasound resulted protective (HR 0.5: 0.3 to 0.9, p = 0.02). At follow-up, rates of cardiovascular death did not differ among the 2 groups (4% vs 4%, p = 0.95). At multivariate analysis, TLR on LM did not increase risk of all cause death (HR 0.4: 0.1 to 1.6, p = 0.22), whereas cardiogenic shock and III tertile of Syntax portended a worse prognosis (HR 4.5: 2.1 to 10.2, p = 0.01 and HR 1.4: 1.1 to 1.6, p = 0.03, respectively). In conclusion, repeated revascularization after implantation of second-generation DES on ULM represents an unfrequent event, being increased in insulin-dependent patients and reduced by intravascular ultrasound. Impact on prognosis remains neutral, being related to clinical presentation and extent of coronary artery disease.


Assuntos
Doença da Artéria Coronariana/terapia , Reestenose Coronária/epidemiologia , Reestenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Idoso , Causas de Morte , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/mortalidade , Feminino , Humanos , Incidência , Masculino , Prognóstico , Retratamento , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
Am J Cardiol ; 120(1): 33-39, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28487035

RESUMO

Transradial access (TRA) is often avoided in favor of the transfemoral access (TFA) during percutaneous coronary interventions of the unprotected left main coronary artery (ULM), due to technical and safety concerns. The aim of this study was to compare the performance of TRA and TFA in the treatment of ULM with second-generation drug-eluting stents. Consecutive patients who underwent percutaneous coronary intervention on ULM with second-generation drug-eluting stents were retrospectively enrolled in the multicenter Failure in Left Main Study With 2nd Generation Stents (FAILS 2) registry. Patients were stratified according to the arterial access. The choice between TRA and TFA was left to each operator's preferences. Bleedings during index hospitalization were the primary end point. Secondary end points were major adverse cardiovascular events (a composite of death, reinfarction, and target lesion revascularization), the single components of major adverse cardiovascular events at follow-up and stent thrombosis. Propensity score matching was executed to account for possible confounding. Overall, 1,247 patients were enrolled (23.2% [289] of female gender, mean age 70.2 ± 10.2 years). Diagnosis at presentation was stable angina in 603 (48.7%) cases, non-ST-segment elevation acute coronary syndrome in 465 (37.3%), ST-segment elevation myocardial infarction in 117 (9.5%). Mean follow-up was 726 ± 654 days. After propensity score with matching, 354 patients were included. The primary end point was significantly reduced in patients treated with TRA (2.0% vs 4.0%, p = 0.042), whereas no differences emerged pertaining the secondary end points, including target lesion revascularization and reinfarction. In conclusion, TRA may reduce in-hospital bleedings in patients undergoing percutaneous treatment of the ULM, without increasing the rate of adverse cardiovascular events at follow-up, and may therefore be safely used in the treatment of the ULM.


Assuntos
Cateterismo Periférico/métodos , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Idoso , Feminino , Artéria Femoral , Seguimentos , Humanos , Masculino , Desenho de Prótese , Artéria Radial , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA