1.
Radiother Oncol ; 200: 110522, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39243863

RESUMO

BACKGROUND AND PURPOSE: This study aimed to evaluate the plan quality of our deep learning-based automated treatment planning method for robustly optimized intensity-modulated proton therapy (IMPT) plans in patients with oropharyngeal carcinoma (OPC). The assessment was conducted through a retrospective and prospective study, blindly comparing manual plans with deep learning plans. MATERIALS AND METHODS: A set of 95 OPC patients was split into training (n = 60), configuration (n = 10), test retrospective study (n = 10), and test prospective study (n = 15). Our deep learning optimization (DLO) method combines IMPT dose prediction using a deep learning model with a robust mimicking optimization algorithm. Dosimetrists manually adjusted the DLO plan for individual patients. In both studies, manual plans and manually adjusted deep learning (mDLO) plans were blindly assessed by a radiation oncologist, a dosimetrist, and a physicist, through visual inspection, clinical goal evaluation, and comparison of normal tissue complication probability values. mDLO plans were completed within an average time of 2.5 h. In comparison, the manual planning process typically took around 2 days. RESULTS: In the retrospective study, in 10/10 (100%) patients, the mDLO plans were preferred, while in the prospective study, 9 out of 15 (60%) mDLO plans were preferred. In 4 out of the remaining 6 cases, the manual and mDLO plans were considered comparable in quality. Differences between manual and mDLO plans were limited. CONCLUSION: This study showed a high preference for mDLO plans over manual IMPT plans, with 92% of cases considering mDLO plans comparable or superior in quality for OPC patients.


Assuntos
Aprendizado Profundo , Neoplasias Orofaríngeas , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Orofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Estudos Prospectivos , Terapia com Prótons/métodos , Masculino , Dosagem Radioterapêutica , Feminino , Pessoa de Meia-Idade , Idoso
2.
Int J Radiat Oncol Biol Phys ; 115(5): 1283-1290, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36535432

RESUMO

PURPOSE: The aim of this study was to evaluate an automated treatment planning method for robustly optimized intensity modulated proton therapy (IMPT) plans for oropharyngeal carcinoma patients and to compare the results with manually optimized robust IMPT plans. METHODS AND MATERIALS: An atlas regression forest-based machine learning (ML) model for dose prediction was trained on CT scans, contours, and dose distributions of robust IMPT plans of 88 oropharyngeal cancer (OPC) patients. The ML model was combined with a robust voxel and dose volume histogram-based dose mimicking optimization algorithm for 21 perturbed scenarios to generate a machine-deliverable plan from the predicted dose distribution. Machine learning optimization (MLO) configuration was performed using a cross-validation approach with 3 × 8 tuning patients and comprised of adjustments to the mimicking optimization, to generate higher-quality MLO plans. Independent testing of the MLO algorithm was performed with another 25 patients. Plan quality of clinical and MLO plans was evaluated by the clinical target volume (D98% voxel-wise minimum dose >94%), organ at risk (OAR) doses, and the normal tissue complication probability (NTCP) (sum (Σ) of grade-2 and grade-3 dysphagia and xerostomia). RESULTS: Adequate robust target coverage was achieved in 24/25 clinical plans and in 23/25 MLO plans in the primary clinical target volume (CTV). In the elective CTV, 22/25 clinical plans and 24/25 MLO plans passed the robust target coverage evaluation threshold. The MLO average Σgrade 2 and Σgrade 3 NTCPs were comparable to the clinical plans (Σgrade 2 NTCPs: clinical 47.5% vs MLO 48.4%, Σgrade 3 NTCPs: clinical 11.9% vs MLO 12.3%). Significant increases in OAR average doses in MLO plans were found in the pharynx constrictor muscles (163 cGy, P = .002) and cervical esophagus (265 cGy, P = .002). The MLO plans were created within 45 minutes. CONCLUSION: This study showed that automated MLO planning can generate robustly optimized MLO plans with quality comparable to clinical plans in OPC patients.


Assuntos
Neoplasias Orofaríngeas , Terapia com Prótons , Radioterapia de Intensidade Modulada , Xerostomia , Humanos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/radioterapia , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Órgãos em Risco/diagnóstico por imagem