Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38544223

RESUMO

Colorimetric characterisation systems based on LEDs and RBG sensors are straightforward to implement, are highly integrable allowing for portable measurement systems and can be constructed using widespread and affordable components. They have already proved to be a satisfactory solution in several applications related to chemical analysis. In this paper, we present an RGB sensor-based prototype for colorimetric characterisation, which can accommodate cuvettes with optical paths of 10 mm and 40 mm. We assessed the impact of experimental condition parameters such as the variability of the analyte volume in the cuvette, as well as the presence of floating particles or deposits at the bottom of the cuvette. While these would not impact the result given by a spectrophotometer that generally has a directional light source, they must be considered in LED/RGB sensor analysers in which the light path is not tightly controlled. We demonstrated that there is a minimal sensor height above the bottom of the cuvette and a minimal analyte level (both depending on the prototype optical path length) above which the analyte volume and the presence of floating particles and deposits have no impact on the prototype output signal. Finally, based on these results, we proposed a test method for a quick dye-displacement assay, in which the reagent is a dye-loaded molecularly imprinted polymer that is poured directly into a cuvette.

2.
Sensors (Basel) ; 24(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38202993

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are a class of materials that have been widely used in the industrial production of a wide range of products. After decades of bioaccumulation in the environment, research has demonstrated that these compounds are toxic and potentially carcinogenic. Therefore, it is essential to map the extent of the problem to be able to remediate it properly in the next few decades. Current state-of-the-art detection platforms, however, are lab based and therefore too expensive and time-consuming for routine screening. Traditional biosensor tests based on, e.g., lateral flow assays may struggle with the low regulatory levels of PFAS (ng/mL), the complexity of environmental matrices and the presence of coexisting chemicals. Therefore, a lot of research effort has been directed towards the development of biomimetic receptors and their implementation into handheld, low-cost sensors. Numerous research groups have developed PFAS sensors based on molecularly imprinted polymers (MIPs), metal-organic frameworks (MOFs) or aptamers. In order to transform these research efforts into tangible devices and implement them into environmental applications, it is necessary to provide an overview of these research efforts. This review aims to provide this overview and critically compare several technologies to each other to provide a recommendation for the direction of future research efforts focused on the development of the next generation of biomimetic PFAS sensors.


Assuntos
Biomimética , Fluorocarbonos , Humanos , Carcinogênese , Carcinógenos , Indústrias
3.
J Chem Educ ; 98(2): 439-444, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33583951

RESUMO

The need to develop interest in STEM (science, technology, engineering, and mathematics) skills in young pupils has driven many educational systems to include STEM as a subject in primary schools. In this work, a science kit aimed at children from 8 to 14 years old is presented as a support platform for an innovative and stimulating approach to STEM learning. The peculiar design of the kit, based on modular components, is aimed to help develop a multitude of skills in the young students, dividing the learning process into two phases. During phase 1 the pupils build the experimental setup and visualize the scientific phenomena, while in phase 2, they are introduced and challenged to understand the principles on which these phenomena are based, guided by a handbook. This approach aims at making the experience more inclusive, stimulating the interest and passion of the pupils for scientific subjects.

4.
Sens Actuators B Chem ; 325: 128973, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33012991

RESUMO

Molecularly imprinted polymers (MIPs) have emerged over the past few decades as interesting synthetic alternatives due to their long-term chemical and physical stability and low-cost synthesis procedure. They have been integrated into many sensing platforms and assay formats for the detection of various targets, ranging from small molecules to macromolecular entities such as pathogens and whole cells. Despite the advantages MIPs have over natural receptors in terms of commercialization, the striking success stories of biosensor applications such as the glucose meter or the self-test for pregnancy have not been matched by MIP-based sensor or detection kits yet. In this review, we zoom in on the commercial potential of MIP technology and aim to summarize the latest developments in their commercialization and integration into sensors and assays with high commercial potential. We will also analyze which bottlenecks are inflicting with commercialization and how recent advances in commercial MIP synthesis could overcome these obstacles in order for MIPs to truly achieve their commercial potential in the near future.

5.
Molecules ; 25(22)2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33182534

RESUMO

The rapid sensing of drug compounds has traditionally relied on antibodies, enzymes and electrochemical reactions. These technologies can frequently produce false positives/negatives and require specific conditions to operate. Akin to antibodies, molecularly imprinted polymers (MIPs) are a more robust synthetic alternative with the ability to bind a target molecule with an affinity comparable to that of its natural counterparts. With this in mind, the research presented in this article introduces a facile MIP-based dye displacement assay for the detection of (±) amphetamine in urine. The selective nature of MIPs coupled with a displaceable dye enables the resulting low-cost assay to rapidly produce a clear visual confirmation of a target's presence, offering huge commercial potential. The following manuscript characterizes the proposed assay, drawing attention to various facets of the sensor design and optimization. To this end, synthesis of a MIP tailored towards amphetamine is described, scrutinizing the composition and selectivity (ibuprofen, naproxen, 2-methoxphenidine, quetiapine) of the reported synthetic receptor. Dye selection for the development of the displacement assay follows, proceeded by optimization of the displacement process by investigating the time taken and the amount of MIP powder required for optimum displacement. An optimized dose-response curve is then presented, introducing (±) amphetamine hydrochloride (0.01-1 mg mL-1) to the engineered sensor and determining the limit of detection (LoD). The research culminates in the assay being used for the analysis of spiked urine samples (amphetamine, ibuprofen, naproxen, 2-methoxphenidine, quetiapine, bupropion, pheniramine, bromopheniramine) and evaluating its potential as a low-cost, rapid and selective method of analysis.


Assuntos
Anfetaminas/urina , Corantes/química , Polímeros Molecularmente Impressos , Polímeros/química , Detecção do Abuso de Substâncias/métodos , Urina/química , Anfetamina/urina , Bromofeniramina/urina , Bupropiona/urina , Relação Dose-Resposta a Droga , Técnicas Eletroquímicas , Reações Falso-Positivas , Humanos , Ibuprofeno/urina , Limite de Detecção , Impressão Molecular , Naproxeno/urina , Feniramina/urina , Piperidinas/urina , Pós , Fumarato de Quetiapina/urina
6.
Sensors (Basel) ; 17(12)2017 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-29168733

RESUMO

Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique-the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume-between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor's potential application in clinical research and diagnosis of e.g., early stage depression.

7.
Molecules ; 21(5)2016 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-27128891

RESUMO

A novel procedure is developed for producing bulk modified Molecularly Imprinted Polymer (MIP) screen-printed electrodes (SPEs), which involves the direct mixing of the polymer particles within the screen-printed ink. This allowed reduction of the sample preparation time from 45 min to 1 min, and resulted in higher reproducibility of the electrodes. The samples are measured with a novel detection method, namely, thermal wave transport analysis (TWTA), relying on the analysis of thermal waves through a functional interface. As a first proof-of-principle, MIPs for dopamine are developed and successfully incorporated within a bulk modified MIP SPE. The detection limits of dopamine within buffer solutions for the MIP SPEs are determined via three independent techniques. With cyclic voltammetry this was determined to be 4.7 × 10(-6) M, whereas by using the heat-transfer method (HTM) 0.35 × 10(-6) M was obtained, and with the novel TWTA concept 0.26 × 10(-6) M is possible. This TWTA technique is measured simultaneously with HTM and has the benefits of reducing measurement time to less than 5 min and increasing effect size by nearly a factor of two. The two thermal methods are able to enhance dopamine detection by one order of magnitude compared to the electrochemical method. In previous research, it was not possible to measure neurotransmitters in complex samples with HTM, but with the improved signal-to-noise of TWTA for the first time, spiked dopamine concentrations were determined in a relevant food sample. In summary, novel concepts are presented for both the sensor functionalization side by employing screen-printing technology, and on the sensing side, the novel TWTA thermal technique is reported. The developed bio-sensing platform is cost-effective and suitable for mass-production due to the nature of screen-printing technology, which makes it very interesting for neurotransmitter detection in clinical diagnostic applications.


Assuntos
Dopamina/análise , Impressão Molecular/métodos , Polímeros/química , Técnicas Eletroquímicas , Eletrodos , Peso Molecular , Condutividade Térmica
8.
Langmuir ; 31(6): 2043-50, 2015 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-25654744

RESUMO

Previous work has indicated that surface imprinted polymers (SIPs) allow for highly specific cell detection through macromolecular cell imprints. The combination of SIPs with a heat-transfer-based read-out technique has led to the development of a selective, label-free, low-cost, and user-friendly cell detection assay. In this study, the breast cancer cell line ZR-75-1 is used to assess the potential of the platform for monitoring the quality of a cell culture in time. For this purpose, we show that the proposed methodology is able to discriminate between the original cell line (adherent growth, ZR-75-1a) and a descendant cell line (suspension growth, ZR-75-1s). Moreover, ZR-75-1a cells were cultured for a prolonged period of time and analyzed using the heat-transfer method (HTM) at regular time intervals. The results of these experiments demonstrate that the thermal resistance (Rth) signal decays after a certain number of cell culture passages. This can likely be attributed to a compromised quality of the cell culture due to cross-contamination with the ZR-75-1s cell line, a finding that was confirmed by classical STR DNA profiling. The cells do not express the same functional groups on their membrane, resulting in a weaker bond between cell and imprint, enabling cell removal by mechanical friction, provided by flushing the measuring chamber with buffer solution. These findings were further confirmed by HTM and illustrate that the biomimetic sensor platform can be used as an assay for monitoring the quality of cell cultures in time.


Assuntos
Biomimética/métodos , Temperatura Alta , Impressão Molecular , Sondas Moleculares/síntese química , Polímeros/síntese química , Técnicas de Cultura de Células , Linhagem Celular Tumoral , Humanos , Repetições de Microssatélites , Sondas Moleculares/metabolismo , Polímeros/metabolismo , Controle de Qualidade , Propriedades de Superfície
9.
Langmuir ; 30(12): 3631-9, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24606112

RESUMO

Surface-imprinted polymers allow for specific cell detection based on simultaneous recognition of the cell shape, cell size, and cell membrane functionalities by macromolecular cell imprints. In this study, the specificity of detection and the detection sensitivity for target cells within a pool of non-target cells were analyzed for a cell-specific surface-imprinted polymer combined with a heat-transfer-based read-out technique (HTM). A modified Chinese hamster ovarian cell line (CHO-ldlD) was used as a model system on which the transmembrane protein mucin-1 (MUC1) could be excessively expressed and for which the occurrence of MUC1 glycosylation could be controlled. In specific cancer cells, the overexpressed MUC1 protein typically shows an aberrant apical distribution and glycosylation. We show that surface-imprinted polymers discriminate between cell types that (1) only differ in the expression of a specific membrane protein (MUC1) or (2) only differ in the membrane protein being glycosylated or not. Moreover, surface-imprinted polymers of cells carrying different glycoforms of the same membrane protein do target both types of cells. These findings illustrate the high specificity of cell detection that can be reached by the structural imprinting of cells in polymer layers. Competitiveness between target and non-target cells was proven to negatively affect the detection sensitivity of target cells. Furthermore, we show that the detection sensitivity can be increased significantly by repetitively exposing the surface to the sample and eliminating non-specifically bound cells by flushing between consecutive cell exposures.


Assuntos
Temperatura Alta , Impressão Molecular , Poliuretanos/química , Animais , Células CHO , Células Cultivadas , Cricetulus , Glicosilação , Microscopia de Fluorescência , Mucina-1/biossíntese , Mucina-1/química , Mucina-1/metabolismo , Poliuretanos/metabolismo , Propriedades de Superfície
10.
Sensors (Basel) ; 14(6): 11016-30, 2014 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-24955945

RESUMO

In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM). HTM relies on the change in thermal resistance upon binding of the target molecule to the MIP-type receptor. A flow-through sensor cell was developed, which is segmented into four quadrants with a volume of 2.5 µL each, allowing four measurements to be done simultaneously on a single substrate. Verification measurements were conducted, in which all quadrants received a uniform treatment and all four channels exhibited a similar response. Subsequently, measurements were performed in quadrants, which were functionalized with different MIP particles. Each of these quadrants was exposed to the same buffer solution, spiked with different molecules, according to the MIP under analysis. With the flow cell design we could discriminate between similar small organic molecules and observed no significant cross-selectivity. Therefore, the MIP array sensor platform with HTM as a readout technique, has the potential to become a low-cost analysis tool for bioanalytical applications.


Assuntos
Dimetilpolisiloxanos/química , Análise em Microsséries/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Impressão Molecular/métodos , Compostos Orgânicos/análise , Compostos Orgânicos/química , Termografia/instrumentação , Biomimética/instrumentação , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Peso Molecular , Condutividade Térmica , Transdutores
11.
ACS Omega ; 9(22): 23155-23171, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38854523

RESUMO

Ensuring a rapid and accurate identification of harmful bacteria is crucial in various fields including environmental monitoring, food safety, and clinical diagnostics. Conventional detection methods often suffer from limitations such as long analysis time, complexity, and the need for qualified personnel. Therefore, a lot of research effort is devoted to developing technologies with the potential to revolutionize the detection of pathogenic bacteria by offering rapid, sensitive, and user-friendly platforms for point-of-care analysis. In this light, biosensors have gained significant commercial attention in recent years due to their simplicity, portability, and rapid analysis capabilities. The purpose of this review is to identify a trend by analyzing which biosensor technologies have become commercially successful in the field of bacteria detection. Moreover, we highlight the characteristics that a biosensor must possess to finally arrive in the market and therefore in the hands of the end-user, and we present critical examples of the market applications of various technologies. The aim is to investigate the reason why certain technologies have achieved commercial success and extrapolate these trends to the future economic viability of a new subfield in the world of biosensing: the development of biomimetic sensor platforms. Therefore, an overview of recent advances in the field of biomimetic bacteria detection will be presented, after which the challenges that need to be addressed in the coming years to improve market penetration will be critically evaluated. We will zoom into the current shortcomings of biomimetic sensors based on imprinting technology and aptamers and try to come up with a recommendation for further development based on the trends observed from previous commercial success stories in biosensing.

12.
Talanta ; 278: 126500, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38991407

RESUMO

Impaired expression of GABA transporters (GATs) is closely related to the pathogenesis of among others Parkinson's disease and epilepsy. As such, lipophilic nipecotic acid analogs have been extensively studied as GAT1-addressing drugs and radioligands but suffer from limited brain uptake due to the zwitterionic properties of the nipecotic acid moiety. Bioisosteric replacement of the carboxylic acid group is a promising strategy to improve the brain uptake, though it requires knowledge on the binding of these isosteres to GAT1. To screen nipecotic acid isosteres for their affinity to GAT1 in a time- and cost-effective manner, this research aims to develop a molecular imprinted polymer (MIP) that mimics the natural binding site of GAT1 and can act as an alternative screening tool to the current radiometric and mass spectrometry cellular-based assays. To this end, a nipecotic acid MIP was created using the electropolymerization of ortho-phenylenediamine (oPD) by cyclic voltammetry (CV). The optimization of the generated receptor layer was achieved by varying the scan rate (50-250 mV/s) and number of CV cycles (5-12), yielding an optimized MIP with an average imprinting factor of 2.6, a linear range of 1-1000 nm, and a theoretical LOD of 0.05 nm, as analyzed by electrical impedance spectroscopy (EIS). Selectivity studies facilitated the investigation of major binding interactions between the MIP and the substrate, building an experimental model that compares characteristics of various analogs. Results from this model indicate that the substrate carboxylic acid group plays a more important role in binding than an amine group, after comparing the binding of cyclohexanecarboxylic acid (average IF of 1.7) and piperidine (average IF of 0.46). The research culminates in a discussion regarding the feasibility of the in vitro model, comparing the synthetic system against the biological performance of GAT1. Thus, evaluating if it is possible to generate a synthetic GAT1 mimic, and if so, provide directions for follow-up research.


Assuntos
Polímeros Molecularmente Impressos , Ácidos Nipecóticos , Polímeros Molecularmente Impressos/química , Ácidos Nipecóticos/química , Ácidos Nipecóticos/metabolismo , Humanos , Proteínas da Membrana Plasmática de Transporte de GABA/metabolismo , Proteínas da Membrana Plasmática de Transporte de GABA/química , Impressão Molecular
13.
CVIR Endovasc ; 7(1): 38, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38641706

RESUMO

BACKGROUND: Endovascular techniques are advancing with the change of treatment paradigm for abdominal aortic aneurysms. Fenestrated EVAR (fEVAR) and branched EVAR (bEVAR) are used for complex aortic aneurysm repair. Both fEVAR and bEVAR have their own advantages and disadvantages. Semi-branches are a new feature that attempt to combine the advantages of both fEVAR and bEVAR. TECHNIQUE: We describe the use of a 4-vessel semi-branched EVAR in a failed EVAR case with a type 1a endoleak. CONCLUSION: The novel feature of semi-branches in custom-made EVAR devices in endovascular aortic treatment following failed EVAR appear to be a feasible option.

14.
Anal Chem ; 85(3): 1475-83, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23249279

RESUMO

Histamine is a biogenic amine that is indispensable in the efficient functioning of various physiological systems. In previous work, a molecularly imprinted polymer (MIP) based sensor platform with impedimetric read-out was presented which could rapidly and at low cost determine histamine concentrations in buffer solutions within pH 7-9. For diagnostic applications, histamine should be detectable in a wider pH range as it mostly occurs in mildly acidic environments. To understand this pH-dependent response of the MIP sensor, we propose a statistical binding analysis model. Within this model, we predict the theoretical performance of MIP based on acrylic acid in the required pH range and verify these results experimentally by UV-vis spectroscopy, microgravimetry, and impedance spectroscopy. Using impedimetric read-out, specific and selective detection of histamine in the physiologically relevant nanomolar concentration range is possible in neutral and mildly acidic phosphate buffer. Finally, this sensor platform was used to analyze the histamine concentration of mildly acidic bowel fluid samples of several test persons. We show that this sensor provides reliable data in the relevant concentration regime, which was validated independently by enzyme-linked immuno sorbent assay (ELISA) tests.


Assuntos
Líquidos Corporais/metabolismo , Espectroscopia Dielétrica/métodos , Duodeno/metabolismo , Histamina/metabolismo , Receptores Artificiais/metabolismo , Sítios de Ligação/fisiologia , Humanos , Concentração de Íons de Hidrogênio
15.
Sensors (Basel) ; 13(7): 9148-59, 2013 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-23863857

RESUMO

In previous work, the novel heat-transfer method (HTM) for the detection of small molecules with Molecularly Imprinted Polymers (MIP)-type receptors was presented. In this study we focus on optimization of this sensor performance, with as final aim to lower the detection limit by reducing the noise level. It was determined that the noise originates foremost from the power supply, which can be controlled by varying the PID parameters. Therefore, the effect of the individual parameters was evaluated by tuning P, I and D separately at a temperature of 37 °C, giving a first indication of the optimal configuration. Next, a temperature profile was programmed and the standard deviation of the heat-transfer resistance over the entire regime was studied for a set of parameters. The optimal configuration, P1-I6-D0, reduced the noise level with nearly a factor of three compared to the original parameters of P10-I5-D0. With the optimized settings, the detection of L-nicotine in buffer solutions was studied and the detection limit improved significantly from 100 nM to 35 nM. Summarizing, optimization of the PID parameters and thereby improving the detection limit is a key parameter for first applications of the HTM-method for MIP receptors in analytical research.


Assuntos
Artefatos , Biomimética/instrumentação , Imunoensaio/instrumentação , Microquímica/instrumentação , Impressão Molecular/métodos , Nanotecnologia/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura
16.
Sensors (Basel) ; 13(11): 14650-61, 2013 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-24172282

RESUMO

In this article we describe the integration of impedance spectroscopy (EIS) and surface plasmon resonance (SPR) into one surface analytic device. A polydimethylsiloxane (PDMS) flow cell is created, matching the dimensions of a commercially available sensor chip used for SPR measurements. This flow cell allowed simultaneous measurements between an EIS and a SPR setup. After a successful integration, a proof of principle study was conducted to investigate any signs of interference between the two systems during a measurement. The flow cell was rinsed with 10 mM Tris-HCl and 1× PBS buffer in an alternating manner, while impedance and shifts of the resonance angle were monitored. After achieving a successful proof of principle, a usability test was conducted. It was assessed whether simultaneous detection occurred when: (i) Protein A is adsorbed to the gold surface of the chip; (ii) The non-occupied zone is blocked with BSA molecules and (iii) IgG1 is bound to the Protein A. The results indicate a successful merge between SPR and EIS.

17.
Cardiovasc Intervent Radiol ; 46(2): 187-193, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36624291

RESUMO

PURPOSE: Iliac branch devices (IBD) are widely used to treat aortoiliac aneurysms with an unfit distal landing zone for standard endovascular aneurysm repair (EVAR). The aim of this retrospective study was to examine the treatment of aortoiliac aneurysms with the combination of the Endurant II(s) stent graft system (Medtronic®) and the E-liac stent graft (Artivion®). MATERIALS AND METHODS: Data of all patients who underwent an EVAR combined with unilateral or bilateral IBD between January 2015 and January 2020 were analyzed. Primary outcomes were technical success at implantation (successful EVAR with IBD extension placement and patency of the grafts without type 1 or type 3 endoleak), and type 1b/3 endoleak, hypogastric artery patency and IBD-related reinterventions during follow-up. Secondary outcomes were all type 1 endoleak, all reinterventions, rupture, and mortality during follow-up. RESULTS: A total of 38 patients were treated with a combination of EVAR with IBD. Technical success was 94.7% (n = 36/38). The 30-day survival was 100%. Median follow-up time was 31 months (range 8-56). During follow-up, no patients developed type 1b or type 3 endoleak and all hypogastric arteries at the side of IBD remained patent. The overall reintervention rate at 12 months follow-up was 5.3% (n = 2/38) and the IBD-related reintervention rate was 2.6% (n = 1/38). CONCLUSION: The combination of the Endurant II(s) and the E-liac stent graft system is an effective and safe procedure for patients with an aortoiliac aneurysm. We confirm the high hypogastric artery patency rate using IBD. Furthermore, these devices have a high technical success rate even when it is combined with an Endurant II(s) EVAR main body.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Humanos , Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Stents/efeitos adversos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese
18.
ACS Sens ; 8(1): 353-362, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36599088

RESUMO

Pseudomonas aeruginosa is a ubiquitous multi-drug-resistant bacterium, capable of causing serious illnesses and infections. This research focuses on the development of a thermal sensor for the indirect detection of P. aeruginosa infection using molecularly imprinted polymers (MIPs). This was achieved by developing MIPs for the detection of pyocyanin, the main toxin secreted by P. aeruginosa. To this end, phenazine was used as a dummy template, evaluating several polymeric compositions to achieve a selective MIP for pyocyanin recognition. The sensitivity of the synthesized MIPs was investigated by UV-vis analysis, with the best composition having a maximum rebinding capacity of 30 µmol g-1 and an imprinting factor (IF) of 1.59. Subsequently, the MIP particles were immobilized onto planar aluminum chips using an adhesive layer, to perform thermal resistance measurements at clinically relevant concentrations of pyocyanin (1.4-9.8 µM), achieving a limit of detection (LoD) of 0.347 ± 0.027 µM. The selectivity of the sensor was also scrutinized by subjecting the receptor to potential interferents. Furthermore, the rebinding was demonstrated in King's A medium, highlighting the potential of the sensor for the indirect detection of P. aeruginosa in complex fluids. The research culminates in the demonstration of the MIP-based sensor's applicability for clinical diagnosis. To achieve this goal, an experiment was performed in which the sensor was exposed to pyocyanin-spiked saliva samples, achieving a limit of detection of 0.569 ± 0.063 µM and demonstrating that this technology is suitable to detect the presence of the toxin even at the very first stage of its production.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Pseudomonas aeruginosa , Piocianina , Técnicas Eletroquímicas
19.
EJNMMI Res ; 13(1): 42, 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37171631

RESUMO

By clearing GABA from the synaptic cleft, GABA transporters (GATs) play an essential role in inhibitory neurotransmission. Consequently, in vivo visualization of GATs can be a valuable diagnostic tool and biomarker for various psychiatric and neurological disorders. Not surprisingly, in recent years several research attempts to develop a radioligand have been conducted, but so far none have led to suitable radioligands that allow imaging of GATs. Here, we provide an overview of the radioligands that were developed with a focus on GAT1, since this is the most abundant transporter and most of the research concerns this GAT subtype. Initially, we focus on the field of GAT1 inhibitors, after which we discuss the development of GAT1 radioligands based on these inhibitors. We hypothesize that the radioligands developed so far have been unsuccessful due to the zwitterionic nature of their nipecotic acid moiety. To overcome this problem, the use of non-classical GAT inhibitors as basis for GAT1 radioligands or the use of carboxylic acid bioisosteres may be considered. As the latter structural modification has already been used in the field of GAT1 inhibitors, this option seems particularly viable and could lead to the development of more successful GAT1 radioligands in the future.

20.
Food Chem ; 404(Pt B): 134653, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36327513

RESUMO

Accurate and fast on-site detection of harmful microorganisms in food products is a key preventive step to avoid food-borne illness and product recall. In this study, screen-printed electrodes (SPEs) were functionalized via a facile strategy with surface imprinted polymers (SIPs). The SIP-coated SPEs were used in combination with the heat transfer method (HTM) for the real-time detection of Escherichia coli. The sensor was tested in buffer, with a reproducible and sensitive response that attained a limit of detection of 180 CFU/mL. Furthermore, selectivity was assessed by analyzing the sensor's response to C. sakazakii, K. pneumoniae and S. aureus as analogue strains. Finally, the device was successfully used for the detection of E. coli in spiked milk as proof-of-application, requiring no additional sample preparation. These results suggest the proposed thermal biosensor possesses the potential of becoming a tool for routine, on-site monitoring of E. coli in food safety applications.


Assuntos
Técnicas Biossensoriais , Escherichia coli , Staphylococcus aureus , Eletrodos , Técnicas Biossensoriais/métodos , Laticínios , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA