Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Neth Heart J ; 32(10): 356-362, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39158682

RESUMO

INTRODUCTION: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. OBJECTIVE: To assess real-world nationwide trends in EVD adoption in the Netherlands. METHODS: Using the Netherlands Heart Registration, all consecutive patients with a de novo S­ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics. RESULT: From 2012-2020, 2190 S­ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S­ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S­ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S­ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001). CONCLUSION: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S­ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S­ICD use is expanding beyond those centres.

2.
Neth Heart J ; 31(5): 181-184, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36862338

RESUMO

Cardiac implantable electronic device (CIED) therapy is an essential element in treating cardiac arrhythmias. Despite their benefits, conventional transvenous CIEDs are associated with a significant risk of mainly pocket- and lead-related complications. To overcome these complications, extravascular devices (EVDs), such as the subcutaneous implantable cardioverter-defibrillator and intracardiac leadless pacemaker, have been developed. In the near future, several other innovative EVDs will become available. However, it is difficult to evaluate EVDs in large studies because of high costs, lack of long-term follow-up, imprecise data or selected patient populations. To improve evaluation of these technologies, real-world, large-scale, long-term data are of utmost importance. A Dutch registry-based study seems to be a unique possibility for this goal due to early involvement of Dutch hospitals in novel CIEDs and an existing quality control infrastructure, the Netherlands Heart Registration (NHR). Therefore, we will soon start the Netherlands-ExtraVascular Device Registry (NL-EVDR), a Dutch nationwide registry with long-term follow-up of EVDs. The NL-EVDR will be incorporated in NHR's device registry. Additional EVD-specific variables will be collected both retrospectively and prospectively. Hence, combining Dutch EVD data will provide highly relevant information on safety and efficacy. As a first step, a pilot project has started in selected centres in October 2022 to optimise data collection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA