Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 140(2): 145-153, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31243547

RESUMO

INTRODUCTION: Hip abductor tendinopathies are becoming increasingly recognized as clinically relevant disorders. However, knowledge about prevalence of abductor tendinopathies and associated disorders of adjacent hip articular and periarticular structures is limited. In this context, the relative diagnostic value of 1.5-T vs. 3.0-T MRI magnets has not been studied yet. MATERIALS AND METHODS: Pelvic MRI scans of 1000 hips from 500 consecutive unselected patients (341 in 3.0-T/159 in 1.5-T magnets, with standardized scanning protocols over the entire study period) were analysed for the detection of abductor tendinosis, calcifying tendinitis, partial or full-thickness tears of the M. gluteus medius (GMed) and/or -minimus (GMin) and trochanteric bursitis (TB). The occurrence of these lesions was correlated to the presence of muscle atrophy (MA) of GMed/GMin, hip joint effusion (JE) and osteoarthritis (OA). RESULTS: Peritrochanteric lesions were observed with a prevalence of 31.4% of all patients (22.3% of all hips). TB occurred almost exclusively in the presence of GMed/GMin tendinopathies. Compared to overall prevalence, patients with MA displayed lesions of GMed/GMin or TB in 70%, patients, with OA in 30% and with JE in 23%. These lesions occurred significantly more often ipsilateral to MA and OA than contralateral (MA: 76.8% vs. 23.2%, p < 0.001; OA: 64.4% vs. 35.6%, p = 0.03; JE: 62.7% vs. 37.3%, p = 0.08). Significantly more tendon lesions, in particular specific radiological diagnoses like partial/full-thickness tears, were detected by 3.0-T MRI than by 1.5 T (p = 0.019). CONCLUSIONS: Peritrochanteric lesions are a prevalent pathology that should specifically be looked for, preferably by 3.0-T MRI, independent of concomitant hip joint pathology.


Assuntos
Articulação do Quadril , Imageamento por Ressonância Magnética/métodos , Tendinopatia , Tendões , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Humanos , Interpretação de Imagem Assistida por Computador , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Tendinopatia/diagnóstico por imagem , Tendinopatia/patologia , Tendões/diagnóstico por imagem , Tendões/patologia
2.
Artigo em Japonês | MEDLINE | ID: mdl-30662032

RESUMO

Brain T1-weighted images using spin echo (SE) sequence has poor contrast at 3.0 Tesla magnetic resonance imaging (3.0 T MRI) systems from the influence of crosstalk and magnetized transfer (MT) effect, and prolongation of the T1 value. Therefore, improving of scan parameters has been reported such as excitation flip angle (FA) and interleave data acquisition. The purpose of this study was to show the effects of alterations of presaturation pulse amplitude and chemical shift selective (CHESS) pulse amplitude. Gray-to-white matter contrast increased with decreasing amplitude of presaturation pulse in whole brain imaging. Presaturation and CHESS pulse consist of radio frequency pulse. Therefore, both pulses have a similar effect on MT pulse. Manual alteration of presaturation pulse amplitude for each scan lacks versatility on clinical use. However, decreasing amplitude of presaturation pulse is equal to decreasing thickness of presaturation pulse. About CHESS pulse, it requires no manual alteration for each scan. For example, switching fat suppression mode from strong to weak increase T1 contrast. Our study demonstrated that using not only low excitation FA and interleave date acquisition but also low amplitude of presaturation and CHESS pulse increase the contrast in T1 SE brain scans at 3.0 T MRI.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Aumento da Imagem
3.
Knee Surg Sports Traumatol Arthrosc ; 25(2): 437-444, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27141867

RESUMO

PURPOSE: To assess articular cartilage changes in the knee joint as detected on 3.0T MR imaging after 2-year follow-up in patients who underwent arthroscopic anterior cruciate ligament reconstruction (ACLR) with or without concomitant meniscal surgery. METHODS: A total of twenty-nine patients (mean age 30.3 ± 10 years), who underwent arthroscopic ACLR, received clinical and imaging follow-up at an average of 27.8 ± 4.8 months after surgery. Our patients were divided into two subgroups: eighteen patients with additional meniscal injuries at the time of arthroscopic ACLR who underwent meniscal surgery and eleven patients with intact menisci. The cartilage status of all knees at the time of arthroscopic ACLR was recorded. All patients underwent an MRI scan preoperatively and at follow-up with the same imaging protocol. Cartilage status of all knee compartments was evaluated at the time of follow-up by MR imaging and the ICRS classification. RESULTS: Deterioration of the cartilage status was found at all knee compartments of our study group, with respect to the number of cartilage defects. The cartilage of the lateral femoral condyle (LFC) was most severely affected, followed by patellar and medial femoral condyle (MFC) cartilage. A statistically significant relation was found between surgery of the medial meniscus and the development of new cartilage defects in LFC (p = 0.01) and MFC (p = 0.03) after adjusting for the site of meniscal surgery. The cartilage of LFC and the status of the medial meniscus were also found to be significantly related (p = 0.04). Partial meniscectomy was found to be associated with an increased incidence of new cartilage defects when compared to either meniscal repair or absence of meniscal surgery, although it was not statistically significant. CONCLUSION: Development of new cartilage lesions was evident after 2-year follow-up in patients with arthroscopic ACLR as detected by MR imaging. There was a multicompartmental pattern of cartilage involvement, and the lateral compartment was most severely affected. Partial meniscectomy at the time of arthroscopic ACLR could be suggested as an additional risk factor for the progression of chondral lesions. LEVEL OF EVIDENCE: Prospective comparative study, Level II.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Cartilagem Articular/cirurgia , Meniscos Tibiais/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Adolescente , Adulto , Artroscopia , Epífises/cirurgia , Feminino , Humanos , Incidência , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Adulto Jovem
4.
Radiol Med ; 122(10): 731-742, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28643295

RESUMO

OBJECTIVE: To compare two fat suppression techniques used for 3D T1-weighted sequence in breast MRI (magnetic resonance imaging), namely Dixon versus spectral fat saturation (fat sat). MATERIALS AND METHODS: All breast MRI examinations performed in a Philips 3 T unit between March 2013 and October 2015 including either a Dixon or a fat sat sequence were retrospectively analyzed. The examinations were subjectively evaluated by two independent experienced readers in a scale of 5 for overall quality of fat suppression, homogeneity of fat suppression, definition of anatomic structures and focal lesions, diagnostic confidence for axillary and internal mammary regions and the presence of artifacts, 1 corresponding to excellent and 5 to non-diagnostic quality. Contrast-to-noise-ratio (CNR) measurements for muscle and focal lesions were also performed. RESULTS: Overall 161 women (mean age 51.6 ± 12.0 years) underwent 189 MR examinations, 113 with the fat saturation and 76 with the Dixon sequence. Interobserver variability was good (kappa = 0.757). In all subjectively evaluated parameters, the Dixon sequence was superior to the fat sat (p < 0.05). Mean values of CNR for muscle and focal lesions were 9.98 (±4.2), 17.9 (±7.53) for the fat sat and 18.3 (±10.4) and 29.3 (±14.1) for the Dixon sequence, respectively (p < 0.001). CONCLUSION: 3D T1 Dixon sequence is superior to fat sat for dedicated breast MRI at 3 T, in terms of efficiency of fat suppression and image quality with the added advantage of optimal exploration of the axillary areas.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Forensic Sci Med Pathol ; 13(2): 135-144, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28251480

RESUMO

In legal medicine, reliable localization and analysis of hematomas in subcutaneous fatty tissue is required for forensic reconstruction. Due to the absence of ionizing radiation, magnetic resonance imaging (MRI) is particularly suited to examining living persons with forensically relevant injuries. However, there is limited experience regarding MRI signal properties of hemorrhage in soft tissue. The aim of this study was to evaluate MR sequences with respect to their ability to show high contrast between hematomas and subcutaneous fatty tissue as well as to reliably determine the volume of artificial hematomas. Porcine tissue models were prepared by injecting blood into the subcutaneous fatty tissue to create artificial hematomas. MR images were acquired at 3T and four blinded observers conducted manual segmentation of the hematomas. To assess segmentability, the agreement of measured volume with the known volume of injected blood was statistically analyzed. A physically motivated normalization taking into account partial volume effect was applied to the data to ensure comparable results among differently sized hematomas. The inversion recovery sequence exhibited the best segmentability rate, whereas the T1T2w turbo spin echo sequence showed the most accurate results regarding volume estimation. Both sequences led to reproducible volume estimations. This study demonstrates that MRI is a promising forensic tool to assess and visualize even very small amounts of blood in soft tissue. The presented results enable the improvement of protocols for detection and volume determination of hemorrhage in forensically relevant cases and also provide fundamental knowledge for future in-vivo examinations.


Assuntos
Hematoma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tela Subcutânea/diagnóstico por imagem , Animais , Patologia Legal , Hematoma/patologia , Modelos Animais , Tela Subcutânea/patologia , Suínos
6.
J Magn Reson Imaging ; 40(1): 58-66, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24222639

RESUMO

PURPOSE: To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. MATERIALS AND METHODS: Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. RESULTS: Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. CONCLUSION: The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver.


Assuntos
Gordura Abdominal/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Gordura Intra-Abdominal/patologia , Hepatopatias/patologia , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Cureus ; 16(1): e52838, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38406138

RESUMO

Objective This study aimed to determine whether differences in the static field strength of 1.5-T and 3.0-T MRI systems affect the diagnostic results of tumor size measurement in breast cancer and to compare them with the results of tumor size in surgical pathology diagnosis. Methods We adopted a retrospective and case-control study design. We included patients with a suspected or confirmed diagnosis of breast cancer who underwent breast MRI at our hospital between January 2017 and March 2023. Diffusion-weighted imaging (DWI), gadolinium-enhanced T1-weighted (Gd-T1WI) MRI, and tumor size from surgical pathology were compared via a significance difference test and correlation analysis between the two groups. In this study, the maximum diameters of the tumor obtained by DWI and Gd-T1WI on 1.5-T and 3.0-T MRI systems were divided by the maximum diameter from surgical pathology diagnosis to arrive at the tumor ratio index. Results A total of 36 patients met the selection criteria: 15 for the 1.5-T system and 21 for the 3.0-T system; all of them were female. The mean ratio of pathological tumor length to diameter measured by MRI for each system showed no significant difference between the groups (p=0.653). For the 1.5-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 1.042 ±0.361, and the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.107 ±0.314, with no significant difference observed between ratios (p=0.345). The correlation coefficient between them was r=0.730 (p=0.002). For the 3.0-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 0.893 ±0.197, while the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.062 ±0.177, with a significant difference between the two (p<0.001). The correlation coefficient between the two groups was 0.695 (p<0.001). Conclusions While there was no significant difference in the ratios of tumor length diameter measured by 1.5-T Gd-T1WI and DWI compared to pathology, there was a significant difference in the ratios of tumor length diameter measured by 3.0-T DWI and Gd-T1WI compared to pathology. Hence, only 3.0-T DWI can lead to a potential underestimation of tumor length.

8.
Acta Radiol ; 54(6): 608-13, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23486561

RESUMO

BACKGROUND: B1 transmission-field inhomogeneity has been reported at 3.0 Tesla (T) breast imaging. Enhancement measurements of breast cancers at 3.0T may be insufficient for some patients and improvements in imaging protocols are needed. PURPOSE: To quantify B1 inhomogeneities in normal tissue and malignant masses at 3.0T breast MR imaging and to evaluate effect of an imaging protocol using an interleaved sagittal sequence in dynamic contrast-enhanced MRI (DCE-MRI). MATERIAL AND METHODS: A total of 76 patients were included who underwent DCE-MRI of the breast at 3.0T with an imaging protocol consisting of 1st, 2nd, and 4-6th bilateral axial sequences, and 3rd and 7th unilateral sagittal sequences. Signal intensity (SI) of normal breast tissue was measured at nipple level in four bilateral locations (anterior, posterior, medial, and lateral). Mean whole breast and location specific SI were calculated and compared between right and left breast using a paired t-test. All malignant masses were classified into three groups according to tumor size on MRI (≤2 cm, 2-4 cm, >4 cm). SI of malignant masses was measured independently on axial and sagittal sequences. The axial-sagittal SI gap in each mass was calculated and difference between right and left breast was compared using the t test. Size of each malignant mass was compared with pathologic findings to assess performance of the imaging protocol. RESULTS: SI of normal breast tissue were lower for the right breast (R-L difference, -91.9; P < 0.0001) and in all four locations (anterior, P < 0.01; posterior, P < 0.01; medial, P < 0.0001; lateral, P < 0.0001). SI of malignant masses were lower for the right breast among same size of the lesions (P < 0.0001), particularly < 4 cm (P < 0.0001). Decreased right to left difference in SI was produced with an interleaved sagittal sequence, as axial-sagittal gap of malignant masses was significant when tumor locates on the right side (P < 0.001). The concordance rate in predicting size of mass in this imaging protocol was 92.2%. CONCLUSION: The interleaved sagittal sequence is helpful to adjust reduced SI of malignant masses on right breast at 3.0T. This imaging protocol is clinically applicable by adding a single sequence during DCE-MRI of the breast.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Imageamento por Ressonância Magnética/métodos , Análise de Variância , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Invasividade Neoplásica
9.
Am J Transl Res ; 13(6): 6229-6235, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34306362

RESUMO

OBJECTIVE: The purpose was to evaluate the diagnostic value of 3.0T MRI in cesarean scar pregnancy (CSP). METHODS: 56 patients with suspected CSP treated in our hospital from August 2018 to July 2020 were recruited as the study cohort and diagnosed using ultrasound and 3.0T MRI. With the pathological examination results as the gold standard and the ultrasound examination results as a comparison, the diagnostic value of 3.0T MRI was evaluated according to the diagnostic accuracy, sensitivity, specificity, and positive and negative misdiagnosis rates, etc. Results: The pathological examination showed that 33 patients were positive for CSP but the other 23 were negative. The accuracy, sensitivity, and specificity of 3.0T MRI in the CSP diagnoses were significantly higher than the accuracy, sensitivity, and specificity of the ultrasound diagnoses (P<0.05), and the positive and negative misdiagnosis rates were significantly lower than the misdiagnosis rates of the ultrasound diagnosis (P<0.05). Moreover, the images from two patients showed that 3.0T MRI can provide clear images of the patients' lesion locations. CONCLUSION: Compared with ultrasound diagnoses, 3.0TMRI has significant advantages in diagnosing CSP and has a high clinical value.

10.
Am J Transl Res ; 13(4): 3806-3810, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34017569

RESUMO

OBJECTIVE: To investigate the effect of 3.0T MRI and ultrasonography in the diagnosis of uterine scar pregnancy (CSP) after caesarean section, and to compare their diagnostic value for CSP. MATERIALS AND METHODS: A retrospective analysis was conducted on 60 patients with CSP treated in our hospital over a period of July 2018 to March 2020. All patients underwent 3.0T MRI, ultrasonography, and surgical termination of pregnancy and pathological analysis. The value of 3.0T MRI and ultrasonography in the diagnosis of CSP was analyzed. RESULTS: (1) The 60 patients were pathologically analyzed. Among these patients, 2 of whom were trophoblastic diseases, 5 were pregnancy abortion, 8 were cervical pregnancy, and 45 were CSP. (2) The results of ultrasound detection were 37 cases of CSP, 7 cases of misdiagnosis, and 8 cases of missed diagnosis; 3.0T MRI results were 44 cases of CSP, 1 case of misdiagnosis, and 1 case of missed diagnosis. (3) The sensitivity (97.78%), specificity (93.33%), coincidence rate (96.67%), positive diagnosis rate (97.78%), negative diagnosis rate (93.33%), AUC (0.973), and 95% CI (0.914-0.996) of 3.0T MRI in diagnosing CSP were significantly higher than those of ultrasound diagnosis (82.22%, 53.33%, 84.09%, 84.09%, 50%, 0.681, 0.051-0.776) (P<0.05). CONCLUSION: The coincidence rate of 3.0T MRI in the diagnosis of CSP after caesarean section is significantly better than that of ultrasound diagnosis, and it can be used to provide reference for clinical diagnosis of CSP after cesarean section.

11.
Exp Ther Med ; 20(5): 43, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32952634

RESUMO

The present study aimed to investigate the anatomical microstructure, features and signals of the fetal thymus by 3.0T FS-T2 weighted turbo spin echo sequences, which could provide imaging evidence for the evaluation of early-stage development of fetal thymus. In addition, the T2-weighted three-dimensional (3D) sequences and the 3D processing may contribute to the establishment of reference ranges for the fetal thymus. A total of 64 specimens obtained from the fetuses of 16-39 weeks of gestational age (GA) were scanned by 3.0T MRI. Morphological changes and quantitative measurements of the fetal thymus were assessed, including the anteroposterior diameter, width, height, surface area and volume. The shape of fetal thymus varied and the majority were X-shaped, with a narrow top and wide bottom. Morphology measurements demonstrated gradual growth with increasing GA. There were high linear correlations between width, height, surface area and volume and GA. No significant differences were observed between the sexes. Post-mortem 3.0T MRI clearly demonstrated changes in external contours and internal structure with GA. The images and data obtained reflect normal development of the fetal thymus and enrich the imaging data of fetal morphometry.

12.
Brain Imaging Behav ; 12(6): 1814-1821, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29480438

RESUMO

To examine the amygdala volume in 2-5-year-old preschool children with autism and explore the relationship between amygdala volumes based on MRI findings and clinical features. A total of 39 cases with clinically diagnosed autism were collected. The oblique coronal T1 weighted image (T1WI) sequence was used to measure the volume of amygdala and the MRI signals were measured and analyzed. The data were compared to that of 24 age-matched healthy children and correlated to the clinical manifestations. The autism and the control groups were subject to brain scanning in 1 week after Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) review. The 39 cases, diagnosed with autism, were associated with social and behavioral deficits through clinical observation, physical and neurological examination, and assessments according to DSM IV, and the range of ABC scores in the autism group was 47-124, with an average score of 84.7 ± 24.1. Abnormal MRI signals were found in 19/78 (24.4%) amygdala in the autism group, the amygdala lesions showed punctuate or flaky low signal, slightly low signal, low to iso-signal, slightly high signal, or iso to high-signal intensity on T1 weighted three-dimendional fast low angle shot(T1FL3D) images. The right amygdala volume average was 1.088 ± 0.38 cm3, while that of the left amygdala was 1.04 ± 0.41 cm3, without any statistically significant difference (t = 0.533, p = 0.596) in the autism group. Among the 24 cases in the control group, the right amygdala volume average was 0.754 ± 0.194 cm3, while that of the left amygdala was 0.666 ± 0.252 cm3; the autism group had a significantly larger right and left amygdala volumes as compared to the age-matched typically developing group with a significant positive correlation between age and right amygdala volume (r = 0.406, p = 0.01). The preschool children with autism had significantly larger bilateral amygdala volumes as compared to age-matched typically developing children, the amygdala lesions may show abnormal signal. A relationship between age and right amygdala volume in the preschool children with autism was established.


Assuntos
Tonsila do Cerebelo/diagnóstico por imagem , Transtorno Autístico/diagnóstico por imagem , Tonsila do Cerebelo/patologia , Transtorno Autístico/patologia , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão
13.
Aging Med (Milton) ; 1(2): 125-132, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31942489

RESUMO

BACKGROUND: The Brain Atrophy and Lesion Index (BALI), which evaluates several common aging-related MRI changes in combination, has been validated as a feasible method to assess the status of structural brain health. Previous studies have been based primarily on older participants and high-field MRI. Here, we tested the generalizability of the BALI by examining its measurement properties in a wide age range at both high and conventional MRI field strengths. METHODS: Subjects (n = 229) who had T2WI at either 1.5T or 3.0T were grouped into younger (age ≤ 60 years) and older (age > 60 years) groups. Image evaluation and scoring were performed independently by two experienced neuroradiologists who have mastered the BALI method. Inter- and intrarater agreement rates were examined comparing age groups and field strengths. RESULTS: The intraclass correlation coefficient for the BALI total score was consistently high under each experimental condition (interrater ICC ≥ 0.92, 95% CI: 0.84-0.96), with no statistical difference between age groups (Fisher Z = 1.43) or field strengths (Z = 0.60). The reliability for BALI category subscores ranged between moderate and perfect (eg, 0.85 vs 0.57 for GA), similar for both age groups and typically greater at 3.0T than at 1.5T. CONCLUSION: The BALI based on T2WI can be reliably applied to the evaluation of the whole-brain health of both younger and older adults at both field strengths, even though high-field MRI is preferable.

14.
Radiol Phys Technol ; 9(2): 154-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26739299

RESUMO

This study aimed to compare the uniformity of fat suppression and image quality between liver acquisition with volume acceleration flex (LAVA-Flex) and LAVA on 60-cm conventional-bore and 70-cm wide-bore 3.0-T magnetic resonance imaging (MRI). The uniformity of fat suppression by LAVA-Flex and LAVA was assessed as the efficiency of suppression of superficial fat at the levels of the liver dome, porta, and renal hilum. Percentage standard deviation (%SD) was calculated using the following equation: %SD (%) = 100 × SD of the regions of interest (ROIs)/mean value of the signal intensity (SI) in the ROIs. Signal-to-noise ratio (SNR) and contrast ratio (CR) were calculated. In the LAVA sequence, the %SD in all slices on wide-bore 3.0-T MRI was significantly higher than that on conventional-bore 3.0-T MRI (P < 0.01). However, there was no significant difference in fat signal uniformity between the conventional and wide-bore scanners when LAVA-Flex was used. In the liver, there were no significant differences in SNR between the two sequences. However, the SNR in the pancreas was lower for the wide-bore scanner than for the conventional-bore scanner for both sequences (P < 0.05). There were no significant differences in CR for the liver and fat between LAVA-Flex and LAVA in both scanners. The CR in the LAVA-Flex images obtained by wide-bore MRI was significantly higher than that in the LAVA-Flex images recorded by conventional-bore MRI (P < 0.001). LAVA-Flex offers more homogenous fat suppression in the upper abdomen than LAVA for both conventional and wide-bore 3.0-T MRI.


Assuntos
Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tecido Adiposo/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino , Músculos/diagnóstico por imagem , Razão Sinal-Ruído , Adulto Jovem
15.
Eur J Radiol ; 84(7): 1299-305, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25956494

RESUMO

PURPOSE: To investigate the difference in T1rho profiles of the entire femoral cartilage between SPGR and b-FFE sequences at 3.0T. MATERIALS AND METHODS: 20 healthy volunteers were enrolled in this study. T1rho images of each subject were acquired with two types of pulse sequences: SPGR and b-FFE. Femoral cartilage segmentation was performed by two independent raters slice-by-slice using Matlab. Inter- and intra-observer reproducibility between the two imaging protocols was calculated. The relative signal intensity (SI) of cartilage, subchondral bone marrow, joint effusion, and the relative signal contrast between structures of the knee were quantitatively measured. The difference in T1rho values between SPGR and b-FFE sequences was statistically analyzed using the Wilcoxon signed-rank test. RESULTS: The average T1rho value of the entire femoral cartilage with b-FFE was significantly higher compared to SPGR (p<0.05). The reproducibility of the segmented area and T1rho values was superior with SPGR compared to b-FFE. The inter-class correlation coefficient was 0.846 on SPGR and 0.824 on b-FFE. The intra-class correlation coefficient of T1rho values was 0.878 on SPGR and 0.836 on b-FFE. The two imaging techniques demonstrated different signal and contrast characteristics. The relative SI of fluid was significantly higher on SPGR, while the relative SI of subchondral bone was significantly higher on b-FFE (p<0.001). There were also significant differences in the relative contrast between fluid-cartilage, fluid-subchondral bone, and cartilage-subchondral bone between the two sequences (all p<0.001). CONCLUSION: We need to pay attention to differences in T1rho values between SPGR and b-FFE in clinical applications.


Assuntos
Cartilagem Articular/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Cartilagem Articular/patologia , Feminino , Humanos , Articulação do Joelho/patologia , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA