Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 619
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur J Immunol ; 54(6): e2350891, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38509863

RESUMO

Metastatic colorectal cancer (CRC) is highly resistant to therapy and prone to recur. The tumor-induced local and systemic immunosuppression allows cancer cells to evade immunosurveillance, facilitating their proliferation and dissemination. Dendritic cells (DCs) are required for the detection, processing, and presentation of tumor antigens, and subsequently for the activation of antigen-specific T cells to orchestrate an effective antitumor response. Notably, successful tumors have evolved mechanisms to disrupt and impair DC functions, underlining the key role of tumor-induced DC dysfunction in promoting tumor growth, metastasis initiation, and treatment resistance. Conventional DC type 2 (cDC2) are highly prevalent in tumors and have been shown to present high phenotypic and functional plasticity in response to tumor-released environmental cues. This plasticity reverberates on both the development of antitumor responses and on the efficacy of immunotherapies in cancer patients. Uncovering the processes, mechanisms, and mediators by which CRC shapes and disrupts cDC2 functions is crucial to restoring their full antitumor potential. In this study, we use our recently developed 3D DC-tumor co-culture system to investigate how patient-derived primary and metastatic CRC organoids modulate cDC2 phenotype and function. We first demonstrate that our collagen-based system displays extensive interaction between cDC2 and tumor organoids. Interestingly, we show that tumor-corrupted cDC2 shift toward a CD14+ population with defective expression of maturation markers, an intermediate phenotype positioned between cDC2 and monocytes, and impaired T-cell activating abilities. This phenotype aligns with the newly defined DC3 (CD14+ CD1c+ CD163+) subset. Remarkably, a comparable population was found to be present in tumor lesions and enriched in the peripheral blood of metastatic CRC patients. Moreover, using EP2 and EP4 receptor antagonists and an anti-IL-6 neutralizing antibody, we determined that the observed phenotype shift is partially mediated by PGE2 and IL-6. Importantly, our system holds promise as a platform for testing therapies aimed at preventing or mitigating tumor-induced DC dysfunction. Overall, our study offers novel and relevant insights into cDC2 (dys)function in CRC that hold relevance for the design of therapeutic approaches.


Assuntos
Neoplasias Colorretais , Células Dendríticas , Dinoprostona , Interleucina-6 , Organoides , Neoplasias Colorretais/imunologia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/metabolismo , Humanos , Células Dendríticas/imunologia , Células Dendríticas/metabolismo , Organoides/imunologia , Organoides/metabolismo , Dinoprostona/metabolismo , Interleucina-6/metabolismo , Interleucina-6/imunologia , Técnicas de Cocultura , Fenótipo , Plasticidade Celular
2.
Nano Lett ; 24(23): 7069-7076, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38808684

RESUMO

Local cells can actively create reverse bending (evagination) in invaginated epithelia, which plays a crucial role in the formation of elaborate organisms. However, the precise physical mechanism driving the evagination remains elusive. Here, we present a three-dimensional vertex model, incorporating the intrinsic cell polarity, to explore the complex morphogenesis induced by local mechanical modulations. We find that invaginated tissues can spontaneously generate local reverse bending due to the shift of the apicobasal polarity. Their exact shapes can be analytically determined by the local apicobasal differential tension and the internal stress. Our continuum theory exhibits three regions in a phase diagram controlled by these two parameters, showing curvature transitions from ordered to disordered states. Additionally, we delve into epithelial curvature transition induced by the nucleus repositioning, revealing its active contribution to the apicobasal force generation. The uncovered mechanical principles could potentially guide more studies on epithelial folding in diverse systems.


Assuntos
Polaridade Celular , Epitélio/fisiologia , Polaridade Celular/fisiologia , Células Epiteliais/citologia , Modelos Biológicos , Morfogênese , Estresse Mecânico , Animais , Humanos
3.
J Synchrotron Radiat ; 31(Pt 1): 136-149, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38095668

RESUMO

Bone material contains a hierarchical network of micro- and nano-cavities and channels, known as the lacuna-canalicular network (LCN), that is thought to play an important role in mechanobiology and turnover. The LCN comprises micrometer-sized lacunae, voids that house osteocytes, and submicrometer-sized canaliculi that connect bone cells. Characterization of this network in three dimensions is crucial for many bone studies. To quantify X-ray Zernike phase-contrast nanotomography data, deep learning is used to isolate and assess porosity in artifact-laden tomographies of zebrafish bones. A technical solution is proposed to overcome the halo and shade-off domains in order to reliably obtain the distribution and morphology of the LCN in the tomographic data. Convolutional neural network (CNN) models are utilized with increasing numbers of images, repeatedly validated by `error loss' and `accuracy' metrics. U-Net and Sensor3D CNN models were trained on data obtained from two different synchrotron Zernike phase-contrast transmission X-ray microscopes, the ANATOMIX beamline at SOLEIL (Paris, France) and the P05 beamline at PETRA III (Hamburg, Germany). The Sensor3D CNN model with a smaller batch size of 32 and a training data size of 70 images showed the best performance (accuracy 0.983 and error loss 0.032). The analysis procedures, validated by comparison with human-identified ground-truth images, correctly identified the voids within the bone matrix. This proposed approach may have further application to classify structures in volumetric images that contain non-linear artifacts that degrade image quality and hinder feature identification.


Assuntos
Aprendizado Profundo , Animais , Humanos , Artefatos , Porosidade , Peixe-Zebra , Osso e Ossos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
4.
Cell Tissue Res ; 397(2): 147-177, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38898317

RESUMO

The marine microturbellarian Macrostomum lignano (Platyhelminthes, Rhabditophora) is an emerging laboratory model used by a growing community of researchers because it is easy to cultivate, has a fully sequenced genome, and offers multiple molecular tools for its study. M. lignano has a compartmentalized brain that receives sensory information from receptors integrated in the epidermis. Receptors of the head, as well as accompanying glands and specialized epidermal cells, form a compound sensory structure called the frontal glandular complex. In this study, we used semi-serial transmission electron microscopy (TEM) to document the types, ultrastructure, and three-dimensional architecture of the cells of the frontal glandular complex. We distinguish a ventral compartment formed by clusters of type 1 (multiciliated) sensory receptors from a central domain where type 2 (collar) sensory receptors predominate. Six different types of glands (rhammite glands, mucoid glands, glands with aster-like and perimaculate granula, vacuolated glands, and buckle glands) are closely associated with type 1 sensory receptors. Endings of a seventh type of gland (rhabdite gland) define a dorsal domain of the frontal glandular complex. A pair of ciliary photoreceptors is closely associated with the base of the frontal glandular complex. Bundles of dendrites, connecting the receptor endings with their cell bodies which are located in the brain, form the (frontal) peripheral nerves. Nerve fibers show a varicose structure, with thick segments alternating with thin segments, and are devoid of a glial layer. This distinguishes platyhelminths from larger and/or more complex invertebrates whose nerves are embedded in prominent glial sheaths.


Assuntos
Imageamento Tridimensional , Platelmintos , Animais , Platelmintos/ultraestrutura , Células Receptoras Sensoriais/ultraestrutura
5.
J Anat ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374322

RESUMO

The anatomy of the avian lower respiratory system includes a complex interaction between air-filled pulmonary tissues, pulmonary air sacs, and much of the postcranial skeleton. Hypotheses related to the function and phylogenetic provenance of these respiratory structures have been posed based on extensive interspecific descriptions for an array of taxa. By contrast, intraspecific descriptions of anatomical variation for these features are much more limited, particularly for skeletal pneumatization, and are essential to establish a baseline for evaluating interspecific variation. To address this issue, we collected micro-computed tomography (µCT) scans of live and deceased African grey parrots (Psittacus erithacus) to assess variation in the arrangement of the lungs, the air sacs, and their respective invasion of the postcranial skeleton via pneumatic foramina. Analysis reveals that the two pairs of caudalmost air sacs vary in size and arrangement, often exhibiting an asymmetric morphology. Further, locations of the pneumatic foramina are more variable for midline, non-costal skeletal elements when compared to other pneumatized bones. These findings indicate a need to better understand contributing factors to variation in avian postcranial respiratory anatomy that can inform future intraspecific and interspecific comparisons.

6.
Mol Pharm ; 21(8): 3848-3865, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38959127

RESUMO

The cholecystokinin type 2 receptor (CCK2-R) represents an ideal target for cancer therapy since it is overexpressed in several tumors and is associated with poor prognosis. Nastorazepide (Z-360), a selective CCK2-R antagonist, has been widely investigated as a CCK2-R ligand for targeted therapy; however, its high hydrophobicity may represent a limit to cell selectivity and optimal in vivo biodistribution. Here, we present three new fluorescent Z-360 derivatives (IP-002G-Rho, IP-002L-Rho, and IP-002M-Rho) in which nastorazepide was linked, through spacers bearing different saccharides (glucose (G), lactose (L), and maltotriose (M)), to sulforhodamine B. A fourth compound (IP-002H-Rho) with no pendant sugar was also synthesized as a control. Through two-dimensional (2D) and three-dimensional (3D) in vitro studies, we evaluated the compound association with and selectivity for CCK2-R-overexpressing cells (A431-CCK2-R+) vs CCK2-R-underexpressing cells (A431 WT). 2D in vitro studies highlighted a progressive increase of IP-002x-Rho association with A431-CCK2-R+ cells according to the linker hydrophilicity, that is, maltotriose > lactose > glucose > hydrogen, with IP-002M-Rho showing a 2.4- and a 1.36-fold higher uptake than IP-002G-Rho and IP-002L-Rho, respectively. Unexpectedly, IP-002H-Rho showed a similar cell association to that of IP-002L-Rho but with no difference between the two tested cell lines. On the contrary, association with A431-CCK2-R+ cells as compared to the A431 WT was found to be 1.08-, 1.14-, and 1.37-fold higher for IP-002G-Rho, IP-002L-Rho, and IP-002M-Rho, respectively, proving IP-002M-Rho to be the best-performing compound, as also confirmed by competition studies. Trafficking studies on A431-CCK2-R+ cells incubated with IP-002M-Rho suggested the coexistence of receptor-mediated endocytosis and simple diffusion. On the contrary, a high and selective uptake of IP-002M-Rho by A431-CCK2-R+ cells only was observed on 3D scaffolds embedded with cells, underlining the importance of 3D models in in vitro preliminary evaluation.


Assuntos
Receptor de Colecistocinina B , Humanos , Receptor de Colecistocinina B/antagonistas & inibidores , Receptor de Colecistocinina B/metabolismo , Linhagem Celular Tumoral , Trissacarídeos/química , Lactose/análogos & derivados , Lactose/química , Glucose/metabolismo
7.
J Sex Med ; 21(5): 494-499, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38477106

RESUMO

BACKGROUND: The acquisition of skills in penile prosthesis surgery has many limitations mainly due to the absence of simulators and models for training. Three-dimensional (3D) printed models can be utilized for surgical simulations, as they provide an opportunity to practice before entering the operating room and provide better understanding of the surgical approach. AIM: This study aimed to evaluate and validate a 3D model of human male genitalia for penile prosthesis surgery. METHODS: This study included 3 evaluation and validation stages. The first stage involved verification of the 3D prototype model for anatomic landmarks compared with a cadaveric pelvis. The second stage involved validation of the improved model for anatomic accuracy and teaching purposes with the Rochester evaluation score. The third stage comprised validation of the suitability of the 3D prototype model as a surgical simulator and for skill acquisition. The third stage was performed at 3 centers using a modified version of a pre-existing, validated questionnaire and correlated with the Rochester evaluation score. OUTCOME: We sought to determine the suitability of 3D model for training in penile prosthesis surgery in comparison with the available cadaveric model. RESULTS: The evaluation revealed a high Pearson correlation coefficient (0.86) between questions of the Rochester evaluation score and modified validated questionnaire. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding replication of the relevant human anatomy for the penile prosthesis surgery procedure. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding its ability to improve technical skills, teach and practice the procedure, and assess a surgeon's ability. Furthermore, the experts stated that compared with the cadaver, the 3D model presented greater ethical suitability, reduced costs, and easier accessibility. CLINICAL IMPLICATIONS: A validated 3D model is a suitable alternative for penile prosthesis surgery training. STRENGTHS AND LIMITATIONS: This is the first validated 3D hydrogel model for penile prosthesis surgery teaching and training that experts consider suitable for skill acquisition. Because specific validated guidelines and questionnaires for the validation and verifications of 3D simulators for penile surgery are not available, a modified questionnaire was used. CONCLUSION: The current 3D model for penile prosthesis surgery shows promising results regarding anatomic properties and suitability to train surgeons to perform penile implant surgery. The possibility of having an ethical, easy-to-use model with lower costs and limited consequences for the environment is encouraging for further development of the models.


Assuntos
Modelos Anatômicos , Implante Peniano , Prótese de Pênis , Humanos , Masculino , Implante Peniano/métodos , Implante Peniano/educação , Cadáver , Treinamento por Simulação/métodos , Impressão Tridimensional , Competência Clínica/normas
8.
Int J Legal Med ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38970679

RESUMO

Photogrammetry is a technique for studying and defining objects' shape, dimension, and position in a three-dimensional space using measurements obtained from two-dimensional photographs. It has gained popularity following the development of computer graphics technologies and has been applied to various branches of medicine. In this study, the authors present a method for low-cost photorealistic documentation of corpses during autopsy using single-camera photogrammetry with a mobile phone. Besides representing the body by demonstrating the injured and non-injured body parts as control, evidencing the body parts on a 3D reconstruction allows easy explanation to nonmedical experts such as lawyers.

9.
Int J Legal Med ; 138(4): 1447-1458, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38386034

RESUMO

Post-mortem computed tomography (PMCT) enables the creation of subject-specific 3D head models suitable for quantitative analysis such as finite element analysis (FEA). FEA of proposed traumatic events is an objective and repeatable numerical method for assessing whether an event could cause a skull fracture such as seen at autopsy. FEA of blunt force skull fracture in adults with subject-specific 3D models in forensic pathology remains uninvestigated. This study aimed to assess the feasibility of FEA for skull fracture analysis in routine forensic pathology. Five cases with blunt force skull fracture and sufficient information on the kinematics of the traumatic event to enable numerical reconstruction were chosen. Subject-specific finite element (FE) head models were constructed by mesh morphing based on PMCT 3D models and A Detailed and Personalizable Head Model with Axons for Injury Prediction (ADAPT) FE model. Morphing was successful in maintaining subject-specific 3D geometry and quality of the FE mesh in all cases. In three cases, the simulated fracture patterns were comparable in location and pattern to the fractures seen at autopsy/PMCT. In one case, the simulated fracture was in the parietal bone whereas the fracture seen at autopsy/PMCT was in the occipital bone. In another case, the simulated fracture was a spider-web fracture in the frontal bone, whereas a much smaller fracture was seen at autopsy/PMCT; however, the fracture in the early time steps of the simulation was comparable to autopsy/PMCT. FEA might be feasible in forensic pathology in cases with a single blunt force impact and well-described event circumstances.


Assuntos
Análise de Elementos Finitos , Patologia Legal , Imageamento Tridimensional , Fraturas Cranianas , Tomografia Computadorizada por Raios X , Humanos , Fraturas Cranianas/diagnóstico por imagem , Fraturas Cranianas/patologia , Masculino , Patologia Legal/métodos , Adulto , Feminino , Pessoa de Meia-Idade , Autopsia/métodos , Idoso
10.
Pediatr Blood Cancer ; : e31241, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39101518

RESUMO

Surgery is a crucial component of pediatric cancer treatment, but conventional methods may lack precision. Image-guided surgery, including fluorescent and radioguided techniques, offers promise for enhancing tumor localization and facilitating precise resection. Intraoperative molecular imaging utilizes agents like indocyanine green to direct surgeons to occult deposits of tumor and to delineate tumor margins. Next-generation agents target tumors directly to improve specificity. Radioguided surgery, employing tracers like metaiodobenzylguanidine (MIBG), complements fluorescent techniques by allowing for detection of tumors at a greater depth. Dual-labeled agents combining both modalities are under development. Three-dimensional modeling and virtual/augmented reality aid in preoperative planning and intraoperative guidance. The above techniques show great promise to benefit patients with pediatric tumors, and their continued development will almost certainly improve surgical outcomes.

11.
Int J Colorectal Dis ; 39(1): 127, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39107626

RESUMO

BACKGROUND: The utilization of three-dimensional printing has grown rapidly within the field of surgery over recent years. Within the subspecialty of colorectal surgery, the technology has been used to create personalized anatomical models for preoperative planning, models for surgical training, and occasionally customized implantable devices and surgical instruments. We aim to provide a systematic review of the current literature discussing clinical applications of three-dimensional printing in colorectal surgery. METHODS: Full-text studies published in English which described the application of 3D printing in pre-surgical planning, advanced surgical planning, and patient education within the field of colorectal surgery were included. Exclusion criteria were duplicate articles, review papers, studies exclusively dealing with surgical training and/or education, studies which used only virtual models, and studies which described colorectal cancer only as it pertained to other organs. RESULTS: Eighteen studies were included in this review. There were two randomized controlled trials, one retrospective outcomes study, five case reports/series, one animal model, and nine technical notes/feasibility studies. There were three studies on advanced surgical planning/device manufacturing, six on pre-surgical planning, two on pelvic anatomy modeling, eight on various types of anatomy modeling, and one on patient education. CONCLUSIONS: While more studies with a higher level of evidence are needed, the findings of this review suggest many promising applications of three-dimensional printing within the field of colorectal surgery with the potential to improve patient outcomes and experiences.


Assuntos
Cirurgia Colorretal , Impressão Tridimensional , Humanos , Cirurgia Colorretal/educação , Modelos Anatômicos , Animais
12.
Acta Neurochir (Wien) ; 166(1): 378, 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39316122

RESUMO

OBJECTIVES: A deep knowledge of the surgical anatomy of the target area is mandatory for a successful operative procedure. For this purpose, over the years, many teaching and learning methods have been described, from the most ancient cadaveric dissection to the most recent virtual reality, each with their respective pros and cons. Photogrammetry, an emergent technique, allows for the creation of three-dimensional (3D) models and reconstructions. Thanks to the spreading of photogrammetry nowadays it is possible to generate these models using professional software or even smartphone apps. This study aims to compare the neuroanatomical photogrammetric models generated by the two most utilized smartphone applications in this domain, Metascan and 3D-Scanner, through quantitative analysis. METHODS: Two human head specimens (four sides) were examined. Anatomical dissection was segmented into five stages to systematically expose well-defined structures. After each stage, a photogrammetric model was generated using two prominent smartphone applications. These models were then subjected to both quantitative and qualitative analysis, with a specific focus on comparing the mesh density as a measure of model resolution and accuracy. Appropriate consent was obtained for the publication of the cadaver's image. RESULTS: The quantitative analysis revealed that the models generated by Metascan app consistently demonstrated superior mesh density compared to those from 3D-Scanner, indicating a higher level of detail and potential for precise anatomical representation. CONCLUSION: Enabling depth perception, capturing high-quality images, offering flexibility in viewpoints: photogrammetry provides researchers with unprecedented opportunities to explore and understand the intricate and magnificent structure of the brain. However, it is of paramount importance to develop and apply rigorous quality control systems to ensure data integrity and reliability of findings in neurological research. This study has demonstrated the superiority of Metascan in processing photogrammetric models for neuroanatomical studies.


Assuntos
Cadáver , Imageamento Tridimensional , Modelos Anatômicos , Fotogrametria , Smartphone , Humanos , Fotogrametria/métodos , Imageamento Tridimensional/métodos , Aplicativos Móveis , Neuroanatomia/educação , Neuroanatomia/métodos , Cabeça/anatomia & histologia , Cabeça/cirurgia
13.
Am J Otolaryngol ; 45(4): 104340, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38723379

RESUMO

OBJECTIVE: Demonstrate the utility of 3D printed temporal bone models in individual patient preoperative planning and simulation. METHODS: 3D models of the temporal bone were made from 5 pediatric and adult patients at a tertiary academic hospital with challenging surgical anatomy planned for cochlear implantation or exteriorization of cholesteatoma with complex labyrinthine fistula. The 3D models were created from CT scan used for preoperative planning, simulation and intraoperative reference. The utility of models was assessed for ease of segmentation and production and impact on surgery in regard to reducing intraoperative time and costs, improving safety and efficacy. RESULTS: Three patients received cochlear implants, two exteriorization of advanced cholesteatoma with fistulas (1 internal auditory canal/cochlea, 1 all three semicircular canals). Surgical planning and intraoperative referencing to the simulations by the attending surgeon and trainees significantly altered original surgical plans. In a case of X-linked hereditary deafness, optimal angles and rotation maneuvers for cochlear implant insertion reduced operating time by 93 min compared to the previous contralateral side surgery. Two cochlear implant cases planned for subtotal petrosectomy approach due to aberrant anatomy were successfully approached through routine mastoidectomy. The cholesteatoma cases were successfully exteriorized without necessitating partial labyrinthectomy or labyrinthine injury. There were no complications. CONCLUSION: 3D printed models for simulation training, surgical planning and use intraoperatively in temporal bone surgery demonstrated significant benefits in designing approaches, development of patient-specific techniques, avoidance of potential or actual complications encountered in previous or current surgery, and reduced surgical time and costs.


Assuntos
Implante Coclear , Impressão Tridimensional , Osso Temporal , Humanos , Osso Temporal/cirurgia , Osso Temporal/diagnóstico por imagem , Implante Coclear/métodos , Masculino , Adulto , Modelos Anatômicos , Tomografia Computadorizada por Raios X , Feminino , Criança , Cuidados Pré-Operatórios/métodos , Adolescente , Pessoa de Meia-Idade , Pré-Escolar
14.
J Shoulder Elbow Surg ; 33(2): e58-e67, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37506998

RESUMO

BACKGROUND: Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS: We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS: After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION: The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Artroplastia do Ombro/efeitos adversos , Cabeça do Fêmur/transplante , Estudos Retrospectivos , Escápula/cirurgia , Complicações Pós-Operatórias/etiologia , Aloenxertos/cirurgia , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Resultado do Tratamento , Amplitude de Movimento Articular
15.
Pediatr Surg Int ; 40(1): 251, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39251414

RESUMO

BACKGROUND: The technical complexity and limited casuistry of neonatal surgical pathology limit the possibilities of developing the necessary technical competencies by specialists in training. Esophageal atresia constitutes the paradigm of this problem. The use of synthetic 3D models for training is a promising line of research, although the literature is limited. METHODS: We conceptualized, designed, and produced an anatomically realistic model for the open correction of type III oesophageal atresia. We validated it with two groups of participants (experts and non-experts) through face, construct, and content-validity questionnaires. RESULTS: The model was validated by nine experts and nine non-experts. The mean procedure time for the experts and non-experts groups was 34.0 and 38.4 min, respectively. Two non-experts did not complete the procedure at the designed time (45 min). Regarding the face validity questionnaire, the mean rating of the model was 3.2 out of 4. Regarding the construct validity, we found statistically significant differences between groups for the equidistance between sutures, 100% correct in the expert group vs. 42.9% correct in the non-expert group (p = 0.02), and for the item "Confirms that tracheoesophageal fistula closure is watertight before continuing the procedure", correctly assessed by 66.7% of the experts vs. by 11.1% of non-experts (p = 0.05). Concerning content validity, the mean score was 3.3 out of 4 for the experts and 3.4 out of 4 for the non-experts. CONCLUSIONS: The present model is a cost-effective, simple-to-produce, and validated option for training open correction of type III esophageal atresia. However, future studies with larger sample sizes and blinded validators are needed before drawing definitive conclusions.


Assuntos
Atresia Esofágica , Modelos Anatômicos , Atresia Esofágica/cirurgia , Humanos , Competência Clínica , Treinamento por Simulação/métodos , Pediatria/educação , Inquéritos e Questionários , Cirurgiões/educação
16.
Sensors (Basel) ; 24(2)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38257593

RESUMO

BACKGROUND: Anthropometric measurements play a crucial role in medico-legal practices. Actually, several scanning technologies are employed in post-mortem investigations for forensic anthropological measurements. This study aims to evaluate the precision, inter-rater reliability, and accuracy of a handheld scanner in measuring various body parts. METHODS: Three independent raters measured seven longitudinal distances using an iPad Pro equipped with a LiDAR sensor and specific software. These measurements were statistically compared to manual measurements conducted by an operator using a laser level and a meterstick (considered the gold standard). RESULTS: The Friedman test revealed minimal intra-rater variability in digital measurements. Inter-rater variability analysis yielded an ICC = 1, signifying high agreement among the three independent raters. Additionally, the accuracy of digital measurements displayed errors below 1.5%. CONCLUSIONS: Preliminary findings demonstrate that the pairing of LiDAR technology with the Polycam app (ver. 3.2.11) and subsequent digital measurements with the MeshLab software (ver. 2022.02) exhibits high precision, inter-rater agreement, and accuracy. Handheld scanners show potential in forensic anthropology due to their simplicity, affordability, and portability. However, further validation studies under real-world conditions are essential to establish the reliability and effectiveness of handheld scanners in medico-legal settings.


Assuntos
Antropologia Forense , Pesquisadores , Humanos , Reprodutibilidade dos Testes , Autopsia , Software
17.
Sensors (Basel) ; 24(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38339750

RESUMO

In order to address the challenges of small and micro-water pollution in parks and the low level of 3D visualization of water quality monitoring systems, this research paper proposes a novel wireless remote water quality monitoring system that combines the Internet of Things (IoT) and a 3D model of reality. To begin with, the construction of a comprehensive 3D model relies on various technologies, including unmanned aerial vehicle (UAV) tilt photography, 3D laser scanning, unmanned ship measurement, and close-range photogrammetry. These techniques are utilized to capture the park's geographical terrain, natural resources, and ecological environment, which are then integrated into the three-dimensional model. Secondly, GNSS positioning, multi-source water quality sensors, NB-IoT wireless communication, and video surveillance are combined with IoT technologies to enable wireless remote real-time monitoring of small and micro-water bodies. Finally, a high-precision underwater, indoor, and outdoor full-space real-scene three-dimensional visual water quality monitoring system integrated with IoT is constructed. The integrated system significantly reduces water pollution in small and micro-water bodies and optimizes the water quality monitoring system.

18.
Sensors (Basel) ; 24(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39123975

RESUMO

This paper presents computer and color vision research focusing on human color perception in VR environments. A VR art gallery with digital twins of original artworks is created for this experiment. In this research, the field of colorimetry and the application of the L*a*b* and RGB color models are applied. The inter-relationships of the two color models are applied to create a color modification of the VR art gallery environment using C# Script procedures. This color-edited VR environment works with a smooth change in color tone in a given time interval. At the same time, a sudden change in the color of the RGB environment is defined in this interval. This experiment aims to record a user's reaction embedded in a VR environment and the effect of color changes on human perception in a VR environment. This research uses lie detector sensors that record the physiological changes of the user embedded in VR. Five sensors are used to record the signal. An experiment on the influence of the user's color perception in a VR environment using lie detector sensors has never been conducted. This research defines the basic methodology for analyzing and evaluating the recorded signals from the lie detector. The presented text thus provides a basis for further research in the field of colors and human color vision in a VR environment and lays an objective basis for use in many scientific and commercial areas.

19.
Int J Mol Sci ; 25(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38256166

RESUMO

Prostate cancer (PCa) has been known as the most prevalent cancer disease and the second leading cause of cancer mortality in men almost all over the globe. There is an urgent need for establishment of PCa models that can recapitulate the progress of genomic landscapes and molecular alterations during development and progression of this disease. Notably, several organoid models have been developed for assessing the complex interaction between PCa and its surrounding microenvironment. In recent years, PCa organoids have been emerged as powerful in vitro 3D model systems that recapitulate the molecular features (such as genomic/epigenomic changes and tumor microenvironment) of PCa metastatic tumors. In addition, application of organoid technology in mechanistic studies (i.e., for understanding cellular/subcellular and molecular alterations) and translational medicine has been recognized as a promising approach for facilitating the development of potential biomarkers and novel therapeutic strategies. In this review, we summarize the application of PCa organoids in the high-throughput screening and establishment of relevant xenografts for developing novel therapeutics for metastatic, castration resistant, and neuroendocrine PCa. These organoid-based studies are expected to expand our knowledge from basic research to clinical applications for PCa diseases. Furthermore, we also highlight the optimization of PCa cultures and establishment of promising 3D organoid models for in vitro and in vivo investigations, ultimately facilitating mechanistic studies and development of novel clinical diagnosis/prognosis and therapies for PCa.


Assuntos
Medicina de Precisão , Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/genética , Próstata , Organoides , Epigenômica , Microambiente Tumoral
20.
Artigo em Inglês | MEDLINE | ID: mdl-39311942

RESUMO

BACKGROUND: Hip-preserving surgery in young patients frequently reveals lesions of the ligamentum teres (LT). Histological and clinical evidence supports that those lesions could be source of intraarticular hip pain. It has been hypothesized that LT degeneration could be linked to the abnormal positioning of the fovea outside the lunate surface during various daily motions. We introduce the "fossa-foveolar mismatch" (FFM) by determining the trajectory of the fovea in the fossa during hip motions, enabling a comparison across diverse hip-pathomorphologies. AIMS: to determine (1) intraobserver reliability and (2) interobserver reproducibility of our computer-assisted 3-dimensional (3D) model of the FFM. MATERIALS AND METHODS: All patients with joint preserving surgery for femoroacetabular impingement syndrome (FAIS) or developmental dysplasia of the hip (DDH) at our institution (11. 2015-08.2019)were initially eligible. We employed a simple random sampling technique to select 15 patients for analysis. Three-dimensional surface models based on preoperative computed tomography (CT) scans were built, the fossa virtually excised, the fovea capitis marked. Models were subjected to physiological range of motion with validated 3D collision detection software. Using a standardized medial view on the resected fossa and the transparent lunate surface, the FFM-index was calculated for 17 motions. It was obtained by dividing the surface occupied by the fovea outside of the fossa by the total foveolar tracking surface. Three observers independently performed all analyses twice. (1) Intraobserver reliability and (2) interobserver reproducibility were calculated using intraclass correlation coefficients (ICCs). RESULTS: (1) We obtained excellent intraobserver ICCs for the FFM-index averaging 0.92 with 95% CI 0.77-0.9 among the three raters for all motions. (2) Interobserver reproducibility between raters was good to excellent, ranging from 0.76 to 0.98. CONCLUSIONS: The FFM-index showed excellent intraobserver reliability and interobserver reproducibility for all motions. This innovative approach deepens our understanding of biomechanical implications, providing valuable insights for identifying patient populations at risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA