Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 18(5): 696-701, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26705559

RESUMO

AIMS: The second-generation multi-electrode-phased radiofrequency pulmonary vein ablation catheter (PVAC GOLD(®)) was redesigned with the intent to improve its safety and efficacy. METHODS AND RESULTS: Using a prospectively designed single-centre database, we retrospectively analysed 128 consecutive patients (102 paroxysmal and 43 female) who underwent their first pulmonary vein isolation with the PVAC GOLD(®). The analysis focused on procedural data as well as in-hospital complications. Baseline characteristics of the patient collective were as follows: mean age 57.9 years, mean CHA2DS2-VASC was 1.73 ± 1.30; structural heart disease was present in seven patients. The PVAC GOLD(®) exhibited procedure durations of 123.1 min ± 27.9, duration of energy delivery was 18.3 min ± 11.4, and fluoroscopy duration was 16.0 min ± 7.7. The redesigned catheter shows major complication [major bleeding, transitory ischaemic attack (TIA), and pericardial tamponade] rates of 2.3% (n = 3). The overall rate of adverse events was 5.4% (n = 7). Bleeding complications were observed in three patients (2.3%), in particular there were two cases (1.6%) of minor bleeding and one case (0.8%) of major bleeding. Two patients suffered pericardial effusion, but there was no need for pericardiocentesis. Besides one TIA, there was no other thrombo-embolic event. Furthermore, one case of post-procedural fever was observed. No deaths, stroke, or haemorrhagic shock occurred. Of the 510 pulmonary veins, 508 could be reached with the PVAC GOLD(®) device using a non-steerable long sheath. CONCLUSION: The PVAC GOLD(®) seems to have an acceptable safety profile. The handling is comparable with the previous generation PVAC(®).


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Idoso , Antitrombinas/uso terapêutico , Ablação por Cateter/efeitos adversos , Dabigatrana/uso terapêutico , Bases de Dados Factuais , Eletrodos Implantados/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Inibidores do Fator Xa/uso terapêutico , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Rivaroxabana/uso terapêutico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA