Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.239
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(11): e2213302120, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-36897980

RESUMO

Spinal injuries in many vertebrates can result in partial or complete loss of locomotor ability. While mammals often experience permanent loss, some nonmammals, such as lampreys, can regain swimming function, though the exact mechanism is not well understood. One hypothesis is that amplified proprioceptive (body-sensing) feedback can allow an injured lamprey to regain functional swimming even if the descending signal is lost. This study employs a multiscale, integrative, computational model of an anguilliform swimmer fully coupled to a viscous, incompressible fluid and examines the effects of amplified feedback on swimming behavior. This represents a model that analyzes spinal injury recovery by combining a closed-loop neuromechanical model with sensory feedback coupled to a full Navier-Stokes model. Our results show that in some cases, feedback amplification below a spinal lesion is sufficient to partially or entirely restore effective swimming behavior.


Assuntos
Retroalimentação Sensorial , Traumatismos da Coluna Vertebral , Animais , Lampreias , Locomoção , Natação , Medula Espinal , Mamíferos
2.
Proc Natl Acad Sci U S A ; 119(46): e2214164119, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36343234

RESUMO

A quantitative understanding of the coupled dynamics of flow and particles in aerosol and droplet transmission associated with speech remains elusive. Here, we summarize an effort that integrates insights into flow-particle dynamics induced by the production plosive sounds during speech with skin-integrated electronic systems for monitoring the production of these sounds. In particular, we uncover diffusive and ballistic regimes separated by a threshold particle size and characterize the Lagrangian acceleration and pair dispersion. Lagrangian dynamics of the particles in the diffusive regime exhibit features of isotropic turbulence. These fundamental findings highlight the value in skin-interfaced wireless sensors for continuously measuring critical speech patterns in clinical settings, work environments, and the home, based on unique neck biomechanics associated with the generation of plosive sounds. We introduce a wireless, soft device that captures these motions to enable detection of plosive sounds in multiple languages through a convolutional neural network approach. This work spans fundamental flow-particle physics to soft electronic technology, with implications in monitoring and studying critical speech patterns associated with aerosol and droplet transmissions relevant to the spread of infectious diseases.


Assuntos
Eletrônica , Fala , Aerossóis , Tamanho da Partícula , Movimento (Física)
3.
Artigo em Inglês | MEDLINE | ID: mdl-39320092

RESUMO

The intricate lung structure is crucial for gas exchange within the alveolar region. Despite extensive research, questions remain about the connection between capillaries and the vascular tree. We propose a computational approach combining three-dimensional morphological modeling with computational fluid dynamics simulations to explore alveolar capillary network connectivity based on blood flow dynamics.We developed three-dimensional sheet-flow models to accurately represent alveolar capillary morphology and conducted simulations to predict flow velocities and pressure distributions. Our approach leverages functional features to identify plausible system architectures. Given capillary flow velocities and arteriole-to-venule pressure drops, we deduced arteriole connectivity details. Preliminary analyses for non-human species indicate a single alveolus connects to at least two 20 µm arterioles or one 30 µm arteriole. Hence, our approach narrows down potential connectivity scenarios, but a unique solution may not always be expected.Integrating our blood flow model results into our previously published gas exchange application, Alvin, we linked these scenarios to gas exchange efficiency. We found that increased blood flow velocity correlates with higher gas exchange efficiency.Our study provides insights into pulmonary microvasculature structure by evaluating blood flow dynamics, offering a new strategy to explore the morphology-physiology relationship that is applicable to other tissues and organs. Future availability of experimental data will be crucial in validating and refining our computational models and hypotheses.

4.
Small ; 20(20): e2307956, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38143295

RESUMO

A cross-comparison of three stop-flow configurations-such as low-pressure (LSF), high-pressure open-circuit (OC-HSF), and high-pressure short-circuit (SC-HSF) stop-flow-is presented to rapidly bring a high velocity flow O(m s-1) within a microchannel to a standstill O(µm s-1). The performance of three stop-flow configurations is assessed by measuring residual flow velocities within microchannels having three orders of magnitude different flow resistances. The LSF configuration outperforms the OC-HSF and SC-HSF configurations within a high flow resistance microchannel and results in a residual velocity of <10 µm s-1. The OC-HSF configuration results in a residual velocity of <150 µm s-1 within a low flow resistance microchannel. The SC-HSF configuration results in a residual velocity of <200 µm s-1 across the three orders-of-magnitude different flow resistance microchannels, and <100 µm s-1 for the low flow resistance channel. It is hypothesized that residual velocity results from compliance in fluidic circuits, which is further investigated by varying the elasticity of microchannel walls and connecting tubing. A numerical model is developed to estimate the expanded volumes of the compliant microchannel and connecting tubings under a pressure gradient and to calculate the distance traveled by the sample fluid. A comparison of the numerically and experimentally obtained traveling distances confirms the hypothesis that the residual velocities are an outcome of the compliance in the fluidic circuit.

5.
Biotechnol Bioeng ; 121(9): 2952-2973, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38853778

RESUMO

The fifth modeling workshop (5MW) was held in June 2023 at Favrholm, Denmark and sponsored by Recovery of Biological Products Conference Series. The goal of the workshop was to assemble modeling practitioners to review and discuss the current state, progress since the last fourth mini modeling workshop (4MMW), gaps and opportunities for development, deployment and maintenance of models in bioprocess applications. Areas of focus were four categories: biophysics and molecular modeling, mechanistic modeling, computational fluid dynamics (CFD) and plant modeling. Highlights of the workshop included significant advancements in biophysical/molecular modeling to novel protein constructs, mechanistic models for filtration and initial forays into modeling of multiphase systems using CFD for a bioreactor and mapped strategically to cell line selection/facility fit. A significant impediment to more fully quantitative and calibrated models for biophysics is the lack of large, anonymized datasets. A potential solution would be the use of specific descriptors in a database that would allow for detailed analyzes without sharing proprietary information. Another gap identified was the lack of a consistent framework for use of models that are included or support a regulatory filing beyond the high-level guidance in ICH Q8-Q11. One perspective is that modeling can be viewed as a component or precursor of machine learning (ML) and artificial intelligence (AI). Another outcome was alignment on a key definition for "mechanistic modeling." Feedback from participants was that there was progression in all of the fields of modeling within scope of the conference. Some areas (e.g., biophysics and molecular modeling) have opportunities for significant research investment to realize full impact. However, the need for ongoing research and development for all model types does not preclude the application to support process development, manufacturing and use in regulatory filings. Analogous to ML and AI, given the current state of the four modeling types, a prospective investment in educating inter-disciplinary subject matter experts (e.g., data science, chromatography) is essential to advancing the modeling community.


Assuntos
Simulação por Computador , Modelos Biológicos , Indústria Farmacêutica
6.
Biotechnol Bioeng ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38993032

RESUMO

Scale-down models (SDM) are pivotal tools for process understanding and improvement to accelerate the development of vaccines from laboratory research to global commercialization. In this study, a 3 L SDM representing a 50 L scale Vero cell culture process of a live-attenuated virus vaccine using microcarriers was developed and qualified based on the constant impeller power per volume principle. Both multivariate data analysis (MVDA) and the traditional univariate data analysis showed comparable and equivalent cell growth, metabolic activity, and product quality results across scales. Computational fluid dynamics simulation further confirmed similar hydrodynamic stress between the two scales.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39189066

RESUMO

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) is a promising treatment for transcatheter aortic valve degeneration, becoming increasingly relevant with an aging population. In redo-TAVR, the leaflets of the initial (index) transcatheter aortic valve (TAV) are displaced vertically when the second TAV is implanted, creating a cylindrical cage that can impair coronary cannulation and flow. Preventing coronary obstruction and maintaining coronary access is essential, especially in young and low-risk patients undergoing TAVR. This study aimed to develop a new leaflet modification strategy using laser ablation to prevent coronary obstruction and facilitate coronary access after repeat TAVR. METHODS: To evaluate the feasibility of the leaflet modification technique using laser ablation, the initial phase of this study involved applying a medical-grade ultraviolet laser for ablation through pericardial tissue. Following this intervention, computational fluid dynamics simulations were utilized to assess the efficacy of the resulting perforations in promoting coronary flow. These simulations played a crucial role in understanding the impact of the modifications on blood flow patterns, ensuring these changes would facilitate the restoration of coronary circulation. RESULTS: Laser ablation of pericardium leaflets was successful, demonstrating the feasibility of creating openings in the TAV leaflets. Flow simulation results show that ablation of index valve leaflets can effectively mitigate the flow obstruction caused by sinus sequestration in redo-TAVR, with the extent of restoration dependent on the number and location of the ablated openings. CONCLUSIONS: Laser ablation could be a viable method for leaflet modification in redo-TAVR, serving as a new tool in interventional procedures.

8.
Mol Pharm ; 21(5): 2406-2414, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38639477

RESUMO

The dissolution testing method described in the United States Pharmacopeia (USP) Chapter ⟨711⟩ is widely used for assessing the release of active pharmaceutical ingredients from solid dosage forms. However, extensive use over the years has revealed certain issues, including high experimental intervariability observed in specific formulations and the settling of particles in the dead zone of the vessel. To address these concerns and gain a comprehensive understanding of the hydrodynamic conditions within the USP 2 apparatus, computational fluid dynamic simulations have been employed in this study. The base design employed in this study is the 900 mL USP 2 vessel along with a paddle stirrer at a 50 rpm rotational speed. Additionally, alternative stirrer designs, including the hydrofoil, pitched blade, and Rushton impeller, are investigated. A comparison is also made between a flat-bottom tank and the USP round-bottom vessel of the same volume and diameter. Furthermore, this work examines the impact of various parameters, such as clearance distance (distance between the bottom of the impeller and bottom of the vessel), number of impeller blades, impeller diameter, and impeller attachment angle. The volume-average shear rate (Stv), fluid velocity (Utv), and energy dissipation rates (ϵtv) represent the key properties evaluated in this study. Comparing the USP2 design and systems with the same stirrer but flat-bottom vessel reveals more homogeneous mixing compared to the USP2 design. Analyzing fluid flow streamlines in different designs demonstrates that hydrofoil stirrers generate more suspension or upward movement of fluid compared to paddle stirrers. Therefore, when impellers are of a similar size, hydrofoil designs generate higher fluid velocities in the coning area. Furthermore, the angle of blade attachment to the hub influences the fluid velocity in the coning area in a way that the 60° angle design generates more suspension than the 45° angle design. The findings indicate that the paddle stirrer design leads to a heterogeneous shear rate and velocity distributions within the vessel compared with the other designs, suggesting suboptimal performance. These insights provide valuable guidance for the development of improved in vitro dissolution testing devices, emphasizing the importance of optimized design considerations to minimize hydrodynamic variability, enhance dissolution characterization, and reduce variability in dissolution test results. Ultimately, such advancements hold potential for improving in vitro-in vivo correlations in drug development.


Assuntos
Hidrodinâmica , Solubilidade , Liberação Controlada de Fármacos , Química Farmacêutica/métodos , Farmacopeias como Assunto , Simulação por Computador , Desenho de Equipamento , Composição de Medicamentos/métodos , Estados Unidos
9.
J Theor Biol ; 595: 111933, 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39260737

RESUMO

We report the effects of varying physiological and other properties on the heat and water exchange in the maxilloturbinate structure (MT) of the bearded seal (Erignathus barbatus or Eb) in realistic environments, using a computational fluid dynamics (CFD) model. We find that the water retention in percent is very high (about 90 %) and relatively unaffected by either cold (-30 °C) or warm (10 °C) conditions. The retention of heat is also high, around 80 % . Based on a consideration of entropy production by the maxilloturbinate system, we show that anatomical and physiological properties of the seal provide good conditions for heat and water exchange at the mucus lining in the seal's nasal cavity. At normal values of tidal volume and maxilloturbinate (MT) length, the air temperature in the MT reaches the body temperature before the air has left the MT channels. This confers a safety factor which is expected to be helpful in exercise, when ventilation increases.

10.
J Endovasc Ther ; : 15266028241241494, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561992

RESUMO

OBJECTIVE: To identify risk factors for in-stent restenosis (ISR) in patients undergoing stent placement for superior mesenteric artery dissection (SMAD) and to determine the hemodynamic mechanism underlying ISR. METHODS: For this retrospective study, patients with SMAD who had ISR after stent placement were included in the ISR group, and age- and sex-matched patients with SMAD who did not experience ISR after stent placement were included in the control group. Clinical, imaging, and hemodynamic data were assessed. Multivariable regression was used to identify independent ISR risk factors. Structural and fluid dynamics simulations were applied to determine the hemodynamic mechanism underlying the occurrence of ISR. RESULTS: The study population included 26 patients with ISR and 26 control patients. Multivariate analysis demonstrated that stent-to-vascular (S/V) ratio (odds ratio [OR], 1.14; 95% confidence interval [CI]: 1.00-1.29; p=0.045), stent proximal position >10 mm away from the SMA root (OR, 108.67; 95% CI: 3.09-3816.42; p=0.010), and high oscillatory shear index (OSI) area (OR, 1.25; 95% CI: 1.02-1.52; p=0.029) were predictors of ISR. In structural and fluid dynamics simulations, a stent proximal position near the abdominal aorta (AA) or entering into the AA reduced the contact area between the proximal struts of the stent and the vascular wall, and alleviated the distal lumen overdilation. CONCLUSION: The S/V ratio, stent proximal position away from the SMA root (>10 mm), and high OSI area are independent risk factors for ISR in patients with SMAD undergoing stent placement. Deploying the proximal end of the stent near the AA or entering into the AA appears to improve the hemodynamic environment in the SMA lumen and ultimately reduce the risk of ISR. CLINICAL IMPACT: In-stent restenosis is an uncommon but potentially catastrophic complication after stent placement for the management of superior mesenteric artery dissection. This study identified risk factors for in-stent restenosis and demonstrated that, as long as the stent can fully cover the dissection range, deploying the proximal end of the stent near the abdominal aorta or less entering into the abdominal aorta may reduce the risk of in-stent restenosis in this patient population.

11.
Vasc Med ; 29(3): 274-285, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38334057

RESUMO

BACKGROUND: False lumen changes (FLCs) are the main reference for the prognosis judgment and treatment plan selection for type IIa superior mesenteric artery dissection (SMAD). METHODS: For this retrospective study, 55 patients with symptomatic type IIa SMAD were included. Computational fluid dynamics (CFD) analysis was used to explore the hemodynamic basis of FLCs. Correlation and multiple linear regression analyses were performed to identify clinical, morphological and hemodynamic factors associated with FLCs. RESULTS: The FLCs of patients with successful conservative treatment (n = 29) are significantly higher than those with failed conservative treatment (n = 26) (58.5 ± 21.1% vs 10.9 ± 17.4%, p < 0.0001). Positive correlations were seen between FLCs and the morphological parameters false lumen length (FLL)/dissection entrance length (DEL) and FLL. In terms of hemodynamic parameters, negative correlations were seen between FLCs and time-averaged wall shear stress (TAWSS), vorticity, and high areas of TAWSS and vorticity, whereas positive correlations were seen between FLCs and oscillatory shear index (OSI), relative residence time (RRT), and high areas of OSI and RRT. Multiple linear regression analysis identified symptom duration (odds ratio [OR], 0.93; 95% CI, 0.91-0.96; p < 0.0001), FLL/DEL (OR, 1.30; 95% CI, 1.01-1.67; p = 0.044), and high RRT area (OR, 2.03; 95% CI, 1.48-2.78; p < 0.0001) as predictors of FLCs. CONCLUSION: The clinical predictor symptom duration, morphological factor FLL/DEL, and the hemodynamic factor high RRT area can serve as predictors of FLCs in patients with symptomatic type IIa SMAD.


Assuntos
Dissecção Aórtica , Hemodinâmica , Artéria Mesentérica Superior , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/fisiopatologia , Dissecção Aórtica/fisiopatologia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/terapia , Adulto , Fatores de Risco , Resultado do Tratamento , Idoso , Tratamento Conservador , Modelos Cardiovasculares , Angiografia por Tomografia Computadorizada , Modelagem Computacional Específica para o Paciente , Valor Preditivo dos Testes , Circulação Esplâncnica
12.
Vasc Med ; : 1358863X241252370, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860436

RESUMO

BACKGROUND: To date, PCSK9 inhibitors are well known for eliminating cardiac and cerebral artery ischemia events by lowering the serum lipid level. However, the pathophysiological value of in-plaque PCSK9 expression is still unclear. METHODS: Advanced plaques removed by carotid endarterectomy were sectioned and stained to identify the PCSK9 expression pattern and its co-expression with rupture-relevant markers. To investigate the correlation of PCSK9 expression with regional blood shear flow, hemodynamic characteristics were analyzed using computational fluid dynamics, and representative parameters were compared between PCSK9 positive and negative staining plaques. To explore this phenomenon in vitro, human aortic vascular smooth muscle cells were used to overexpress and knock down PCSK9. The impacts of PCSK9 modulations on mechanical sensor activity were testified by western blot and immunofluorescence. Real-time polymerase chain reaction was used to evaluate the transcription levels of downstream rupture-prone effectors. RESULTS: PCSK9 distribution in plaque preferred cap and shoulder regions, residing predominantly in smooth muscle actin-positive cells. Cap PCSK9 expression correlated with fibrous cap thickness negatively and co-expressed with MMP-9, both pointing to the direction of plaque rupture. A hemodynamic profile indicated a rupture-prone feature of cap PCSK9 expression. In vitro, overexpression and knockdown of PCSK9 in human aortic vascular smooth muscle cells has positive modulation on mechanical sensor Yes-associated protein 1 (YAP) activity and transcription levels of its downstream rupture-prone effectors. Serial section staining verified in situ colocalization among PCSK9, YAP, and downstream effectors. CONCLUSIONS: Cap PCSK9 possesses a biomarker for rupture risk, and its modulation may lead to a novel biomechanical angle for plaque interventions.

13.
Biomed Eng Online ; 23(1): 71, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39054524

RESUMO

BACKGROUND: Personalized modeling is a promising tool to improve abdominal aortic aneurysm (AAA) rupture risk assessment. Computed tomography (CT) and quantitative flow (Q-flow) magnetic resonance imaging (MRI) are widely regarded as the gold standard for acquiring patient-specific geometry and velocity profiles, respectively. However, their frequent utilization is hindered by various drawbacks. Ultrasound is used extensively in current clinical practice and offers a safe, rapid and cost-effective method to acquire patient-specific geometries and velocity profiles. This study aims to extract and validate patient-specific velocity profiles from Doppler ultrasound and to examine the impact of the velocity profiles on computed hemodynamics. METHODS: Pulsed-wave Doppler (PWD) and color Doppler (CD) data were successfully obtained for six volunteers and seven patients and employed to extract the flow pulse and velocity profile over the cross-section, respectively. The US flow pulses and velocity profiles as well as generic Womersley profiles were compared to the MRI velocities and flows. Additionally, CFD simulations were performed to examine the combined impact of the velocity profile and flow pulse. RESULTS: Large discrepancies were found between the US and MRI velocity profiles over the cross-sections, with differences for US in the same range as for the Womersley profile. Differences in flow pulses revealed that US generally performs best in terms of maximum flow, forward flow and ratios between forward and backward flow, whereas it often overestimates the backward flow. Both spatial patterns and magnitude of the computed hemodynamics were considerably affected by the prescribed velocity boundary conditions. Larger errors and smaller differences between the US and generic CFD cases were observed for patients compared to volunteers. CONCLUSION: These results show that it is feasible to acquire the patient-specific flow pulse from PWD data, provided that the PWD acquisition could be performed proximal to the aneurysm region, and resulted in a triphasic flow pattern. However, obtaining the patient-specific velocity profile over the cross-section using CD data is not reliable. For the volunteers, utilizing the US flow profile instead of the generic flow profile generally resulted in improved performance, whereas this was the case in more than half of the cases for the patients.


Assuntos
Aorta Abdominal , Estudos de Viabilidade , Hemodinâmica , Ultrassonografia Doppler , Humanos , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Masculino , Idoso , Feminino , Adulto , Modelos Cardiovasculares , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Velocidade do Fluxo Sanguíneo
14.
Biomed Eng Online ; 23(1): 69, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39039565

RESUMO

BACKGROUND: Properly understanding the origin and progression of the thoracic aortic aneurysm (TAA) can help prevent its growth and rupture. For a better understanding of this pathogenesis, the aortic blood flow has to be studied and interpreted in great detail. We can obtain detailed aortic blood flow information using magnetic resonance imaging (MRI) based computational fluid dynamics (CFD) with a prescribed motion of the aortic wall. METHODS: We performed two different types of simulations-static (rigid wall) and dynamic (moving wall) for healthy control and a patient with a TAA. For the latter, we have developed a novel morphing approach based on the radial basis function (RBF) interpolation of the segmented 4D-flow MRI geometries at different time instants. Additionally, we have applied reconstructed 4D-flow MRI velocity profiles at the inlet with an automatic registration protocol. RESULTS: The simulated RBF-based movement of the aorta matched well with the original 4D-flow MRI geometries. The wall movement was most dominant in the ascending aorta, accompanied by the highest variation of the blood flow patterns. The resulting data indicated significant differences between the dynamic and static simulations, with a relative difference for the patient of 7.47±14.18% in time-averaged wall shear stress and 15.97±43.32% in the oscillatory shear index (for the whole domain). CONCLUSIONS: In conclusion, the RBF-based morphing approach proved to be numerically accurate and computationally efficient in capturing complex kinematics of the aorta, as validated by 4D-flow MRI. We recommend this approach for future use in MRI-based CFD simulations in broad population studies. Performing these would bring a better understanding of the onset and growth of TAA.


Assuntos
Aorta , Simulação por Computador , Hidrodinâmica , Imageamento por Ressonância Magnética , Humanos , Aorta/diagnóstico por imagem , Aorta/fisiologia , Modelos Cardiovasculares , Hemodinâmica , Velocidade do Fluxo Sanguíneo , Processamento de Imagem Assistida por Computador/métodos , Estresse Mecânico , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia
15.
Environ Res ; 263(Pt 1): 119982, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39270960

RESUMO

Oxy-fuel circulating fluidized bed combustion is known as one of the most potent fuel combustion technologies that capture ultra-low greenhouse gases and pollutant emissions. While many investigations have been conducted for carbon capturing, the associated in-situ desulfurization process using calcium-based sorbents should also be underlined. This paper critically reviews the effects of changes in the operating environment on in-situ desulfurization processes compared to conventional air combustion. A comprehensive understanding of the process, encompassing hydrodynamic, physical and chemical aspects can be a guideline for designing the oxy-fuel combustion process with effective sulfur removal, potentially eliminating the need of a flue gas desulfurization unit. Results from thermogravimetric analyzers and morphological changes of calcium-based materials were presented to offer an insight into the sulfation mechanisms involved in the oxy-fuel circulating fluidized beds. Recently findings suggested that in-situ direct desulfurization is influenced not only by the desulfurization kinetics but also by the fluidization characteristics of calcium-based materials. Therefore, a complex reaction analysis that incorporated oxy-combustion reactions, computational fluid dynamics modeling, in-situ desulfurization reaction models and particle behavior can provide a thorough understanding of desulfurization processes across the reactor. Meanwhile, machine learning as a robust tool to predict desulfurization efficiency and improve operational flexibility should be applied with consideration of environmental improvement and economic feasibility.

16.
Int J Med Sci ; 21(9): 1604-1611, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006846

RESUMO

Purpose: To investigate morphological and hemodynamic characteristics of the ophthalmic artery (OA) in patients with white matter hyperintensity (WMH), and the association of the presence and severity of WMH with OA characteristics. Methods: This cross-sectional study included 44 eyes of 25 patients with WMH and 38 eyes of 19 controls. The Fazekas scale was adopted as criteria for evaluating the severity of white matter hyperintensities. The morphological characteristics of the OA were measured on the basis of three-dimensional reconstruction. The hemodynamic parameters of the OA were calculated using computational fluid dynamics simulations. Results: Compared with the control group, the diameter (16.0±0.27 mm vs. 1.71±0.18 mm, P=0.029), median blood flow velocity (0.12 m/s vs. 0.22 m/s, P<0.001), mass flow ratio (2.16% vs. 3.94%, P=0.012) and wall shear stress (2.65 Pa vs. 9.31 Pa, P<0.001) of the OA in patients with WMH were significantly decreased. After adjusting for confounding factors, the diameter, blood flow velocity, wall shear stress, and mass flow ratio of the OA were significantly associated with the presence of WMH. Male sex and high low-density protein level were associated with moderate-to-severe total WMH, and smoking was associated with the moderate-to-severe periventricular WMH. Conclusions: The diameter, blood flow velocity, mass flow ratio, and wall shear stress of the OA were independently associated with the presence of WMH. Atherosclerosis might be involved in the common mechanism of the occurrence of WMH and the OA changes.


Assuntos
Hemodinâmica , Artéria Oftálmica , Substância Branca , Humanos , Masculino , Feminino , Artéria Oftálmica/diagnóstico por imagem , Artéria Oftálmica/fisiopatologia , Substância Branca/diagnóstico por imagem , Substância Branca/fisiopatologia , Substância Branca/irrigação sanguínea , Substância Branca/patologia , Estudos Transversais , Hemodinâmica/fisiologia , Pessoa de Meia-Idade , Idoso , Velocidade do Fluxo Sanguíneo , Imageamento por Ressonância Magnética , Adulto
17.
Heart Vessels ; 39(3): 195-205, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37897523

RESUMO

Fractional flow reserve (FFR) has been established as a gold standard for functional coronary ischemia. At present, the FFR can be calculated from coronary computed tomography angiography (CCTA) images (CT-FFR). Previous studies have suggested that CT-FFR outperforms CCTA and invasive coronary angiography (ICA) in determining hemodynamic significance of stenoses. Recently, a novel automatical algorithm of CT-FFR called RuiXin-FFR has been developed. The present study is designed to investigate the predictive value of this algorithm and its value in therapeutic decision making. The present study retrospectively included 166 patients with stable coronary artery disease (CAD) who underwent CCTA screening and diagnostic ICA examination at Peking University People's Hospital, in 73 of whom wire-derived FFR was also measured. CT-FFR analyses were performed with a dedicated software. All patients were followed up for at least 1 year. We validated the accuracy of RuiXin-FFR with invasive FFR as the standard of reference, and investigated the role of RuiXin-FFR in predicting treatment strategy and long-term prognosis. The mean age of the patients was 63.3 years with 63.9% male. The CT-FFR showed a moderate correlation with wire-derived FFR (r = 0.542, p < 0.0001) and diagnostic accuracy of 87.6% to predict myocardial ischemia (AUC: 0.839, 95% CI 0.728-0.950), which was significantly higher than CCTA and ICA. In the multivariate logistic regression analysis, CT-FFR ≤ 0.80 was an independent predictor of undergoing coronary revascularization (OR: 45.54, 95% CI 12.03-172.38, p < 0.0001), whereas CT-FFR > 0.80 was an independent predictor of non-obstructive CAD (OR: 14.67, 95% CI 5.42-39.72, p < 0.0001). Reserving ICA and revascularization for vessels with positive CT-FFR could have reduced the rate of ICA by 29.6%, lowered the rate of ICA in vessels without stenosis > 50% by 11.7%, and increased the rate of revascularization in patients receiving ICA by 21.2%. The average follow-up was 23.7 months, and major adverse cardiovascular events (MACE) occurred in 11 patients. The rate of MACE was significantly lower in patients with CT-FFR > 0.80. The new algorithm of CT-FFR can be used to predict the invasive FFR. The RuiXin-FFR can also provide useful information for the screening of patients in whom further ICA is indeed needed and prognosis evaluation.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Algoritmos , Valor Preditivo dos Testes
18.
Bioessays ; 44(3): e2100263, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34984707

RESUMO

Herein, I discuss the enduring mystery of the receptor layout in the vertebrate olfactory system. Since the awarding of the 2004 Nobel Prize to Axel and Buck for their discovery of the gene family that encodes olfactory receptors, our field has enjoyed a golden era. Despite this Renaissance, an answer to one of the most fundamental questions for any sensory system-what is the anatomical logic of its receptor array?-eludes us, still, for olfaction! Indeed, the only widely debated hypothesis, finding its origins in the musing of another Nobel laureate Sir Edgar Adrian, has it that the vertebrate nose organizes its receptors according to the "sorptive" properties of their ligands. This idea, known as the "sorption" or "chromatography" hypothesis, enjoys considerable support despite being controversial. Here, I review the history of the hypothesis-its rises and falls-and discuss the latest data and future prospects for this perennial idea whose history I liken to the mythical Phoenix.


Assuntos
Neurônios Receptores Olfatórios , Receptores Odorantes , Animais , Cromatografia , Prêmio Nobel , Odorantes , Receptores Odorantes/genética , Olfato , Vertebrados
19.
Ann Vasc Surg ; 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39341556

RESUMO

OBJECTIVES: During the past decade simulation has become standard in most surgical training programs, but objective evaluation of the performance has been a challenge. The optimal components of open surgery's simulation have also been questioned. The goal of this study was to evaluate the benefit of adding a hands-on exercise prior to a formal vascular training course. The participants' performance was objectively evaluated using Computional Fluid Dynamics (CFD) assessment of vascular anastomoses. METHODS: In this study 51 residents participated in an on-line surgical hands-on training course, performing six end-to-side anastomoses. The residents were randomly divided into two groups. Group 1. also underwent basic surgical skill training (BSST) before starting the vascular course. The groups were compared based on CFD assessment of vascular anastomoses, combined with on-line personalized feedback. RESULTS: Among measured parameters of functional assessment, the mean of six anastomoses showed significantly better results in Group 1. when compared with control Group 2 (Oscillatory Shear Index: 0,022 vs. 0,025 p=0,002; Maximum pressure: 7939 vs. 7971 p=0,00037; Velocity: 0,12 vs. 0,12 p=0,0000; Helicity: 297 vs. 393 p=0,0065; Vorticity: 5258 vs. 6628 p=0,0019; Wall Shear Stress: 1,83 vs. 1,97 p= 0,000047). These results showed no significant correlation between participants' experience level, specialization, and workplace. CONCLUSIONS: BSST before a formal vascular simulation course positively affects the anastomosis quality, independent of experience level, specialization, and workplace. BSST is suggested before a vascular course to improve performance and progress. Further studies are needed to analyse the impact of this combined simulation training on performing anastomoses.

20.
Artif Organs ; 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39361246

RESUMO

BACKGROUND: ShuttlePump is a novel total artificial heart (TAH) recently introduced to potentially overcome the limitations associated with the current state-of-the-art mechanical circulatory support devices intended for adults. In this study, we adapted the outflow cannulation of the previously established ShuttlePump TAH and evaluated the anatomical compatibility using the virtual implantation technique. METHODS: We retrospectively assessed the anatomical compatibility of the ShuttlePump using virtual implantation techniques within 3D-reconstructed anatomies of adult heart failure patients. Additionally, we examined the impact of outflow cannula modification on the hemocompatibility of the ShuttlePump through computational fluid dynamic simulations. RESULTS: A successful virtual implantation in 9/11 patients was achieved. However, in 2 patients, pump interaction with the thoracic cage was observed and considered unsuccessful virtual implantation. A strong correlation (r <-0.78) observed between the measured anatomical parameters and the ShuttlePump volume exceeding pericardium highlights the importance of these measurements apart from body surface area. The numerical simulation revealed that the angled outflow cannulation resulted in a maximum pressure drop of 1.8 mmHg higher than that of the straight outflow cannulation. With comparable hemolysis index, the shear stress thresholds of angled outflow differ marginally (<5%) from the established pump model. Similar washout behavior between the pump models indicate that the curvature did not introduce stagnation zone. CONCLUSION: This study demonstrates the anatomic compatibility of the ShuttlePump in patients with biventricular failure, which was achieved by optimizing the outflow cannulation without compromising hemocompatibility. Nevertheless, clinical validation is critical to ensure the clinical applicability of these findings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA