Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
BMC Infect Dis ; 20(1): 301, 2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32321418

RESUMO

BACKGROUND: In Ghana, pre-school-aged children (PSAC) are at risk of intestinal schistosomiasis and are living in need of praziquantel treatment. To better assess the infection burden within this vulnerable demographic group, we have provided a comparative assessment of the prevalence of Schistosoma mansoni in pre-school-aged children by urine circulating cathodic antigen (CCA) dipsticks, real-time PCR Taqman® faecal assays and Kato-Katz coproscopy. METHODS: In all, 190 pre-school-aged children were sampled from three endemic communities (viz. Tomefa, Torgahkope/Adakope, and Manheam) around Weija dam, Southern Ghana. Fresh stool and urine samples were collected from all participants for diagnosis. RESULTS: Among all the three communities, the urine-CCA assay recorded the highest prevalence values of 90.5% (95% CI 80.4-96.4), 87.9% (95% CI 76.7-95), and 81.2% (95% CI 69.9-89.6) in Tomefa, Torgahkope/Adakope, and Manheam respectively. Prevalence by real-time PCR was 50% (95% CI 35.5-64.5), 8% (95% CI 2.2-19.2) and 16.7% (95% CI 8.3-28.5), while by Kato-Katz was 55.6% (95% CI 42.5-68.1), 8.6% (95% CI 2.9-19) and 11.6% (95% CI 5.1-21.6) respectively. Children aged 1 year and over were found to be positive with the urine-CCA assay; by the ages of 3-4, over 50% were urine-CCA patent. The sensitivity and specificity of the POC-CCA dipsticks, when compared against the combined results of Kato-Katz/TaqMan results was found to be 84.1% (95% CI = 72.7-92.1) and 12.9% (95% CI = 6.6-22) respectively. CONCLUSIONS: We propose that the urine-CCA dipstick may be a useful rapid diagnostic tool to estimate the prevalence of intestinal schistosomiasis in PSAC, particularly in rapid identification of at-risk areas. However, our assessment has shown that it possible to record false positives when compared to combined Kato-Katz and qPCR results. To guide PSAC praziquantel treatment needs, we propose the urine CCA assay should be included in routine surveillance of intestinal schistosomiasis alongside other diagnostics such as Kato-Katz and urine filtration.


Assuntos
Antígenos de Helmintos/urina , Testes Diagnósticos de Rotina/métodos , Fezes/parasitologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Esquistossomose mansoni/diagnóstico , Urinálise/métodos , Animais , Antígenos de Helmintos/análise , Bioensaio/métodos , Líquidos Corporais/química , Líquidos Corporais/imunologia , Líquidos Corporais/parasitologia , Pré-Escolar , Fezes/química , Feminino , Gana/epidemiologia , Humanos , Lactente , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Praziquantel/uso terapêutico , Prevalência , Schistosoma mansoni/genética , Schistosoma mansoni/imunologia , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/parasitologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
2.
Trop Med Int Health ; 24(3): 371-378, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30549391

RESUMO

OBJECTIVE: To evaluate three non-invasive assays for the diagnosis of schistosomiasis mansoni in an Egyptian village. METHODS: Urine was collected for the detection of circulating cathodic antigen (CCA) and cell-free parasite DNA (cfpd) by Point-of-contact (POC)-cassette assay and PCR, respectively. These tests were compared to Kato-Katz (KK) faecal thick smear for detection of Schistosoma mansoni eggs. RESULTS: Disease prevalence by POC-CCA assay was 86%; by PCR it was 39% vs. 27% by KK. Compared to KK, the sensitivity of POC-CCA reached 100%, but its specificity was only 19.2% with 41% accuracy. Sensitivity of the PCR assay for cfpd was 55.56%, and specificity was 67.12% with 64% accuracy. A new end point was calculated for combined analysis of KK, POC-CCA assay and PCR. Sensitivity for the three tests was 52.94%, 90.2% and 76.47%; specificity was 100% for KK and PCR and 18.37% for POC-CCA. The accuracy calculated for the three tests at the end point was 76% for KK, 55% for POC-CCA assay and 88% for PCR. CONCLUSION: Conventional PCR assay for detection of cfpd provides a potential screening tool for intestinal schistosomiasis with reliable specificity, reasonable accuracy and affordable financial and technical cost.


OBJECTIF: Evaluer trois tests non invasifs pour le diagnostic de la schistosomiase mansoni dans un village égyptien. MÉTHODES: L'urine a été collectée pour la détection de l'antigène cathodique circulant (ACC) et de l'ADN du parasite libéré des cellules (cfpd) par le test en cassette POC (point-of-contact) et par PCR, respectivement. Ces tests ont été comparés au test de Kato Katz (KK) sur frottis fécal épais pour la détection des œufs de Schistosoma mansoni. RÉSULTATS: La prévalence de la maladie par dosage POC-ACC était de 86%; elle était de 39% par PCR contre 27% par KK. Par rapport à KK, la sensibilité du POC-ACC atteignait 100%, mais sa spécificité n'était que de 19,2% avec une précision de 41%. La sensibilité du PCR pour la cfpd était de 55,56% et sa spécificité de 67,12% avec une précision de 64%. Un nouveau seuil a été calculé pour l'analyse combinée des tests KK, POC-ACC et PCR. La sensibilité pour les trois tests était de 52,94%, 90,2% et 76,47%; la spécificité était de 100% pour KK et PCR et de 18,37% pour POC-ACC. La précision calculée pour les trois tests au point seuil était de 76% pour KK, 55% pour le POC-ACC et 88% pour la PCR. CONCLUSION: Le test PCR conventionnel pour la détection de la cfpd constitue un outil de dépistage potentiel de la schistosomiase intestinale avec une spécificité fiable, une précision raisonnable et un coût financier et technique abordable.


Assuntos
Antígenos de Helmintos/urina , Bioensaio/métodos , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/urina , Adolescente , Adulto , Animais , Ácidos Nucleicos Livres , Criança , Feminino , Humanos , Masculino , Prevalência , Sensibilidade e Especificidade , Adulto Jovem
3.
Analyst ; 144(1): 212-219, 2018 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-30328427

RESUMO

Accurate and sensitive point-of-care diagnostic tools are critical for schistosomiasis control and elimination. The existing ultrasensitive lateral flow assay for the detection of Schistosoma circulating anodic antigen (CAA) has demonstrated excellent sensitivity but is time-consuming and requires significant laboratory infrastructure that limits its applicability at the point of care. To address this challenge, we sought to develop an alternative sample preparation method to concentrate CAA from large-volume urine samples requiring little-to-no laboratory equipment. The developed method relies on electrostatic interactions between the negatively-charged CAA biomarker and positively-charged poly(amidoamine) (PAMAM) dendrimers functionalized to the surface of magnetic particles. After CAA capture on the surface of the PAMAM-functionalized magnetic beads, the supernatant was removed, and CAA was eluted into a small-volume, high-salt elution buffer. This concentrated eluate was subsequently applied to the existing lateral flow assay. The PAMAM-functionalized magnetic bead-based CAA concentration method was extensively characterized for its robustness, evaluated on a set of endemic urine samples, and compared to spin filter-based concentration methods. The novel bead-based sample preparation method used only disposable laboratory materials, resulted in a 200-fold improvement in CAA limits of detection, and performed just as well as infrastructure-intensive and high-cost spin filter methods. Additionally, the functionalized beads were robust to variations in sample pH and storage conditions. The PAMAM-functionalized magnetic bead-based CAA concentration method represents a promising step toward ultrasensitive schistosomiasis diagnosis at the point of care.


Assuntos
Antígenos de Helmintos/urina , Dendrímeros/química , Glicoproteínas/urina , Proteínas de Helminto/urina , Imunoensaio/métodos , Compostos de Ferro/química , Adolescente , Adulto , Animais , Antígenos de Helmintos/imunologia , Glicoproteínas/imunologia , Proteínas de Helminto/imunologia , Humanos , Limite de Detecção , Fenômenos Magnéticos , Masculino , Pessoa de Meia-Idade , Schistosoma mansoni/química , Adulto Jovem
4.
Parasitology ; 145(11): 1355-1366, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29506583

RESUMO

The inadequacy of current diagnostics for the detection of low worm burdens in humans means that schistosomiasis mansoni is more widespread than previously acknowledged. With the inception of mass drug treatment programmes aimed at disease elimination and the advent of human vaccine trials, the need for more sensitive diagnostics is evident. In this review, we evaluate the merits and limitations of the principal diagnostic methods, namely detection of eggs in faeces; anti-schistosome antibodies in serum; parasite-derived proteins and glycans in serum or urine; parasite DNA in blood, faeces or urine. Only in the baboon model, where actual worm burden is determined by portal perfusion, have faecal smear and circulating antigen methods been calibrated, and shown to have thresholds of detection of 10-19 worm pairs. There is scope for improvement in all the four methods of detection, e.g. the identification of single targets for host antibodies to improve the specificity of enzyme linked immunosorbent assay. Despite recent advances in the definition of the schistosome secretome, there have been no comprehensive biomarker investigations of parasite products in the urine of infected patients. Certainly, the admirable goal of eliminating schistosomiasis will not be achieved unless individuals with low worm burdens can be diagnosed.


Assuntos
Parasitologia/métodos , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Animais , Anticorpos Anti-Helmínticos/sangue , Antígenos de Helmintos/sangue , Antígenos de Helmintos/urina , Cricetinae , DNA de Helmintos/sangue , DNA de Helmintos/urina , Ensaio de Imunoadsorção Enzimática , Fezes/parasitologia , Humanos , Camundongos , Modelos Animais , Papio , Contagem de Ovos de Parasitas , Schistosoma mansoni/genética , Sensibilidade e Especificidade
5.
BMC Public Health ; 18(1): 478, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29642875

RESUMO

BACKGROUND: Kato-Katz technique has been the mainstay test in Schistosoma mansoni diagnosis in endemic areas. However, recent studies have documented its poor sensitivity in evaluating Schistosoma mansoni infection especially in areas with lower rates of transmission. It's the primary diagnostic tool in monitoring impact of the Kenya national school based deworming program on infection transmission, but there is need to consider a more sensitive technique as the prevalence reduces. Therefore, this study explored the relationship between results of the stool-based Kato-Katz technique with urine-based point-of-care circulating cathodic antigen (POC-CCA) test in view to inform decision-making by the program in changing from Kato-Katz to POC-CCA test. METHODS: We used two cross-sectional surveys conducted pre- and post- mass drug administration (MDA) using praziquantel in a representative random sample of children from 18 schools across 11 counties. A total of 1944 children were randomly sampled for the study. Stool and urine samples were tested for S. mansoni infection using Kato-Katz and POC-CCA methods, respectively. S. mansoni prevalence using each technique was calculated and 95% confidence intervals obtained using binomial regression model. Specificity (Sp) and sensitivity (Sn) were determined using 2 × 2 contingency tables and compared using the McNemar's chi-square test. RESULTS: A total of 1899 and 1878 children were surveyed at pre- and post-treatment respectively. S. mansoni infection prevalence was 26.5 and 21.4% during pre- and post-treatment respectively using POC-CCA test, and 4.9 and 1.5% for pre- and post-treatment respectively using Kato-Katz technique. Taking POC-CCA as the gold standard, Kato-Katz was found to have significantly lower sensitivity both at pre- and post-treatment, Sn = 12.5% and Sn = 5.2% respectively, McNemar test χ2m = 782.0, p < 0.001. In overall, the results showed a slight/poor agreement between the two methods, kappa index (k) = 0.11, p < 0.001, inter-rater agreement = 77.1%. CONCLUSIONS: Results showed POC-CCA technique as an effective, sensitive and accurate screening tool for Schistosoma mansoni infection in areas of low prevalence. It was up to 14-fold accurate than Kato-Katz which had extremely inadequate sensitivity. We recommend usage of POC-CCA alongside Kato-Katz examinations by Schistosomiasis control programs in low prevalence areas.


Assuntos
Antígenos de Helmintos/urina , Técnicas e Procedimentos Diagnósticos , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Adolescente , Animais , Criança , Pré-Escolar , Estudos Transversais , Fezes/parasitologia , Feminino , Humanos , Quênia/epidemiologia , Masculino , Administração Massiva de Medicamentos , Modelos Estatísticos , Praziquantel/uso terapêutico , Prevalência , Schistosoma mansoni/imunologia , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/epidemiologia , Instituições Acadêmicas , Sensibilidade e Especificidade
6.
Clin Infect Dis ; 65(4): 568-574, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28430889

RESUMO

Background: The unprecedented increase in number of African refugees arriving in Europe is confronting clinicians and general practitioners with the question of whether or not and how to screen migrants from endemic regions for Schistosoma mansoni infection. Methods: We assessed the accuracy of 3 different diagnostic tests for S. mansoni infection (stool microscopy [samples prepared by sedimentation technique], serology, and point-of-care circulating cathodic antigen [POC-CCA] urine cassette test) in 107 newly arrived asymptomatic Eritrean refugees in Switzerland. Result: Sixty-three study participants (59%) tested positive by at least 1 of the 3 methods. Thirty-seven participants (35%) were considered to have active schistosomiasis, either due to the detection of parasite eggs in stool and/or the presence of a concordant positive serology and urine POC-CCA test, which we consider to be a suitable surrogate marker of active infection. Of 23 microscopy-positive participants, 22 were positive by serology (95.7% sensitivity) and 21 were positive by the urine POC-CCA test (91.3% sensitivity). The combination of serology and urine POC-CCA testing detected all 23 microscopy-positive study participants (100% sensitivity). Conclusions: With a sensitivity of 100% (95% confidence interval, 82.2%-100%), the combination of serology plus urine POC-CCA testing appears to be the most sensitive screening option for asymptomatic S. mansoni infection in Eritrean refugees, compared with stool sedimentation microscopy.


Assuntos
Antígenos de Helmintos/urina , Parasitologia/métodos , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/parasitologia , Adulto , Animais , Anticorpos Anti-Helmínticos/sangue , Infecções Assintomáticas , Estudos Transversais , Eosinofilia , Eritreia , Fezes/parasitologia , Feminino , Humanos , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Refugiados , Schistosoma mansoni , Esquistossomose mansoni/imunologia , Sensibilidade e Especificidade , Adulto Jovem
7.
Bull World Health Organ ; 94(7): 522-533A, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27429491

RESUMO

OBJECTIVE: To assess the accuracy of point-of-care testing for circulatory cathodic antigen in the diagnosis of schistosome infection. METHODS: We searched MEDLINE, EMBASE, LILACS and other bibliographic databases for studies published until 30 September 2015 that described circulatory cathodic antigen testing compared against one to three Kato-Katz tests per subject - for Schistosoma mansoni - or the filtration of one 10-ml urine sample per subject - for S. haematobium. We extracted the numbers of true positives, false positives, true negatives and false negatives for the antigen testing and performed meta-analyses using a bivariate hierarchical regression model. FINDINGS: Twenty-six studies published between 1994 and 2014 met the inclusion criteria. In the detection of S. mansoni, a single antigen test gave a pooled sensitivity of 0.90 (95% confidence interval, CI: 0.84-0.94) and a pooled specificity of 0.56 (95% CI: 0.39-0.71; n = 7) when compared against a single Kato-Katz test. The corresponding values from comparisons with two to three Kato-Katz tests per subject were 0.85 (95% CI: 0.80-0.88) and 0.66 (95% CI: 0.53-0.76; n = 14), respectively. There appeared to be no advantage in using three antigen tests per subject instead of one. When compared against the results of urine filtration, antigen testing for S. haematobium showed poor sensitivity and poor specificity. The performance of antigen testing was better in areas of high endemicity than in settings with low endemicity. CONCLUSION: Antigen testing may represent an effective tool for monitoring programmes for the control of S. mansoni.


Assuntos
Antígenos de Helmintos/imunologia , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Esquistossomose/imunologia , Antígenos de Helmintos/urina , Fezes/parasitologia , Humanos , Esquistossomose/urina , Sensibilidade e Especificidade
8.
Exp Parasitol ; 166: 37-43, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27018063

RESUMO

Neurocysticercosis (NCC), an infection of the brain by Taenia solium (Ts) cysts, is the most common cause of adult-onset epilepsy in developing countries. Serological testing consists primarily of varying methods to detect antibodies in body fluids and more recently antigen (Ag) detection assays to identify individuals or animals with viable parasites. Antigen assays currently in use employ monoclonal antibodies (mAbs) raised against T. saginata, which have known cross reactivity to animal cestodes but are highly specific in human samples. We produced, characterized and tested 21 mAbs raised against T. solium whole cyst antigens, vesicular fluid or excretory secretory products. Reactivity of the TsmAbs against specific cyst structures was determined using immunofluorescence and immunohistochemistry on histological sections of Ts muscle cysts. Four TsmAbs reacted to vesicular space alone, 9 to the neck and cyst wall, one to the neck and vesicular space and 7 to the neck, cyst wall and vesicular space. An in-house ELISA assay to detect circulating Ts antigen, using the TsmAbs as capture antibodies and a rabbit polyclonal anti-Ts whole cyst antibody as a detector antibody demonstrated that eight of the 21 TsmAbs detected antigens in known NCC-positive human sera and three of these also in urine samples. Reactivity was expressed as normalized ratios of optical densities (OD positive control/OD negative control). Three TsmAbs had ratios >10 and five between 2 and 10. The TsmAbs have potential utility for the diagnosis and post-treatment monitoring of patients with viable NCC infections.


Assuntos
Anticorpos Monoclonais/imunologia , Antígenos de Helmintos/análise , Neurocisticercose/diagnóstico , Taenia solium/imunologia , Animais , Anticorpos Anti-Helmínticos/imunologia , Anticorpos Monoclonais/metabolismo , Especificidade de Anticorpos , Antígenos de Helmintos/sangue , Antígenos de Helmintos/urina , Bile/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Imunofluorescência , Hibridomas/imunologia , Camundongos , Camundongos Endogâmicos BALB C , Neurocisticercose/imunologia , Coelhos , Especificidade da Espécie , Suínos
9.
Euro Surveill ; 20(23)2015 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-26084315

RESUMO

In February 2015, a male patient from Eritrea with persistent abdominal pain and rectal bleeding was diagnosed with Schistosoma mansoni infection upon examination of a rectal biopsy. In May 2015, repeated stool microscopy identified S. mansoni infection in another Eritrean patient with abdominal pain and considerable eosinophilia (34%). Use of point-of-care circulating cathodic antigen (POC-CCA) tests on urine confirmed S. mansoni infection in both patients. Wider application of non-invasive POC-CCA urine tests will improve schistosomiasis diagnosis and clinical management in migrants.


Assuntos
Antígenos de Helmintos/urina , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma mansoni/imunologia , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/urina , Viagem , Adolescente , Animais , Anti-Helmínticos/uso terapêutico , Biópsia , Técnicas de Laboratório Clínico , Eritreia , Fezes/parasitologia , Alemanha , Glicoproteínas , Proteínas de Helminto , Humanos , Masculino , Praziquantel/uso terapêutico , Doenças Retais , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/tratamento farmacológico , Sensibilidade e Especificidade , Migrantes , Resultado do Tratamento , Adulto Jovem
10.
Parasite Immunol ; 36(10): 509-21, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24965663

RESUMO

Traditionally serum and/or CSF specimens have been used for detection of either specific antibodies or antigens as a supportive diagnosis of NCC. However, in recent days, much interest has been shown employing noninvasive specimens such as urine. In our study, we identified and compared a profile of circulating antigenic peptides of parasite origin in three different body fluids (CSF, serum and urine) obtained from confirmed NCC cases and control subjects. The circulating antigenic peptides were resolved by SDS-PAGE and subjected to immunoblotting. For confirmation of their origin as parasite somatic or excretory secretory (ES) material, immunoreactivity was tested employing affinity purified polyclonal Taenia solium metacestode anti-somatic or ES antibodies, respectively. Only lower molecular weight antigenic peptides were found circulating in urine in contrast to serum and CSF specimens. Few somatic peptides were identified to be 100% specific for NCC (19·5 kDa in all three specimens; 131, 70 kDa in CSF and serum only; 128 kDa in CSF only). Similarly, the specific ES peptides detected were 32 kDa (in all three specimens), 16·5 kDa (in serum and CSF only), and 15 kDa (urine only). A test format detecting either one or more of these specific peptides would enhance the sensitivity in diagnosis of NCC.


Assuntos
Antígenos de Helmintos/análise , Neurocisticercose/diagnóstico , Peptídeos/análise , Animais , Anticorpos Anti-Helmínticos/sangue , Antígenos de Helmintos/sangue , Antígenos de Helmintos/líquido cefalorraquidiano , Antígenos de Helmintos/imunologia , Antígenos de Helmintos/urina , Eletroforese em Gel de Poliacrilamida , Humanos , Immunoblotting , Peso Molecular , Doenças Parasitárias/imunologia , Peptídeos/imunologia , Sensibilidade e Especificidade
11.
BMC Infect Dis ; 14: 210, 2014 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-24742192

RESUMO

BACKGROUND: Determining the variation of circulating cathodic antigen (CCA) in urine and egg counts variation in stool between days in Schistosoma mansoni (S. mansoni) infected individuals is vital to decide whether or not to rely on a single-sample test for diagnosis of Schistosomiasis. In this study, the magnitude of day-to-day variation in urine-CCA test scores and in faecal egg counts was evaluated in school children in Ethiopia. METHODS: A total of 620 school children (age 8 to 12 years) were examined for S. mansoni infection using double Kato-Katz and single urine-CCA cassette methods (batch 32727) on three consecutive days. RESULTS: The prevalence of S. mansoni infection was 81.1% based on triple urine-CCA-cassette test and 53.1% based on six Kato-Katz thick smears. Among the study participants, 26.3% showed fluctuation in urine CCA and 32.4% showed fluctuation in egg output. Mean egg count as well as number of cases in each class of intensity and intensity of cassette band color varied over the three days of examination. Over 85% of the children that showed day-to-day variations in status of S. mansoni infection from negative to positive or vice versa by the Kato-Katz and the CCA methods had light intensity of infection. The fluctuation in both the CCA test scores and faecal egg count was not associated with age and sex. CONCLUSIONS: The current study showed day-to-day variation in CCA and Kato-Katz test results of children infected with S. mansoni. This indicates the necessity of more than one urine or stool samples to be collected on different days for more reliable diagnosis of S. mansoni infection in low endemic areas.


Assuntos
Antígenos de Helmintos/urina , Fezes/parasitologia , Contagem de Ovos de Parasitas , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma mansoni/imunologia , Esquistossomose mansoni/diagnóstico , Animais , Biomarcadores/urina , Criança , Estudos Transversais , Etiópia/epidemiologia , Feminino , Humanos , Masculino , Prevalência , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/parasitologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
12.
Parasitology ; 141(14): 1841-55, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24932595

RESUMO

The potential of various quantitative lateral flow (LF) based assays utilizing up-converting phosphor (UCP) reporters for the diagnosis of schistosomiasis is reviewed including recent developments. Active infections are demonstrated by screening for the presence of regurgitated worm antigens (genus specific polysaccharides), whereas anti-Schistosoma antibodies may indicate ongoing as well as past infections. The circulating anodic antigen (CAA) in serum or urine (and potentially also saliva) is identified as the marker that may allow detection of single-worm infections. Quantitation of antigen levels is a reliable method to study effects of drug administration, worm burden and anti-fecundity mechanisms. Moreover, the ratio of CAA and circulating cathodic antigen (CCA) is postulated to facilitate identification of either Schistosoma mansoni or Schistosoma haematobium infections. The UCP-LF assays allow simultaneous detection of multiple targets on a single strip, a valuable feature for antibody detection assays. Although antibody detection in endemic regions is not a useful tool to diagnose active infections, it gains potential when the ratio of different classes of antibody specific for the parasite/disease can be determined. The UCP-LF antibody assay format allows this type of multiplexing, including testing a linear array of up to 20 different targets. Multiple test spots would allow detection of specific antibodies, e.g. against different Schistosoma species or other pathogens as soil-transmitted helminths. Concluding, the different UCP-LF based assays for diagnosis of schistosomiasis provide a collection of tests with relatively low complexity and high sensitivity, covering the full range of diagnostics needed in control programmes for mapping, screening and monitoring.


Assuntos
Anticorpos Anti-Helmínticos/análise , Antígenos de Helmintos/análise , Interações Hospedeiro-Parasita , Schistosoma/imunologia , Esquistossomose/diagnóstico , Animais , Anticorpos Anti-Helmínticos/sangue , Anticorpos Anti-Helmínticos/urina , Antígenos de Helmintos/sangue , Antígenos de Helmintos/urina , Ensaio de Imunoadsorção Enzimática , Fezes/parasitologia , Glicoproteínas/análise , Proteínas de Helminto/análise , Humanos , Contagem de Ovos de Parasitas , Sistemas Automatizados de Assistência Junto ao Leito , Polissacarídeos/imunologia , Schistosoma/isolamento & purificação , Esquistossomose/parasitologia , Sensibilidade e Especificidade , Especificidade da Espécie
13.
Lancet Microbe ; 5(4): e366-e378, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38467130

RESUMO

BACKGROUND: Accurate diagnosis is pivotal for implementing strategies for surveillance, control, and elimination of schistosomiasis. Despite their low sensitivity in low-endemicity areas, microscopy-based urine filtration and the Kato-Katz technique are considered as reference diagnostic tests for Schistosoma haematobium and Schistosoma mansoni infections, respectively. We aimed to collate all available evidence on the accuracy of other proposed diagnostic techniques. METHODS: In this systematic review and meta-analysis, we searched PubMed, Embase, the Cochrane Library, and LILACS for studies published from database inception to Dec 31, 2022, investigating the sensitivity and specificity of diagnostic tests for S haematobium and S mansoni infections against Kato-Katz thick smears or urine microscopy (reference tests) involving adults (aged ≥18 years), school-aged children (aged 7 to 18 years), or preschool-aged children (aged 1 month to 7 years). We extracted raw data on true positives, true negatives, false positives, and false negatives for the diagnostic tests and data on the number of participants, study authors, publication year, journal, study design, participants' age and sex, prevalence of Schistosoma infection, and treatment status. To account for imperfect reference tests, we used a hierarchical Bayesian latent class meta-analysis to model test accuracy. FINDINGS: Overall, we included 121 studies, assessing 28 different diagnostic techniques. Most studies (103 [85%] of 121) were done in Africa, 14 (12%) in South America, one (1%) in Asia, and one (1%) in an unknown country. Compared with the reference test, Kato-Katz thick smears, circulating cathodic antigen urine cassette assay version 1 (CCA1, 36 test comparisons) had excellent sensitivity (95% [95% credible interval 88-99]) and reasonable specificity (74% [63-83]) for S mansoni. ELISA-based tests had a performance comparable to circulating cathodic antigen, but there were few available test comparisons. For S haematobium, proteinuria (42 test comparisons, sensitivity 73% [62-82]; specificity 94% [89-98]) and haematuria (75 test comparisons, sensitivity 85% [80-90]; specificity 96% [92-99]) reagent strips showed high specificity, with haematuria reagent strips having better sensitivity. Despite limited data, nucleic acid amplification tests (NAATs; eg, PCR or loop-mediated isothermal amplification [LAMP]) showed promising results with sensitivity estimates above 90%. We found an unclear risk of bias of about 70% in the use of the reference or index tests and of 50% in patient selection. All analyses showed substantial heterogeneity (I2>80%). INTERPRETATION: Although NAATs and immunological diagnostics show promise, the limited information available precludes drawing definitive conclusions. Additional research on diagnostic accuracy and cost-effectiveness is needed before the replacement of conventional tests can be considered. FUNDING: WHO and Luxembourg Institute of Health.


Assuntos
Schistosoma mansoni , Esquistossomose Urinária , Criança , Pré-Escolar , Adulto , Animais , Humanos , Adolescente , Schistosoma haematobium , Hematúria/diagnóstico , Fitas Reagentes , Microscopia , Teorema de Bayes , Fezes , Antígenos de Helmintos/urina , Urinálise , Esquistossomose Urinária/diagnóstico , Testes Diagnósticos de Rotina/métodos
14.
Trop Med Int Health ; 18(8): 1029-35, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23590255

RESUMO

OBJECTIVE: To evaluate the diagnostic performance of antigen detecting urine-CCA cassette test for the detection of Schistosoma mansoni infection in areas of moderate prevalence in Ethiopia. METHODS: Stool specimens were collected from 620 schoolchildren on three consecutive days. The samples were microscopically examined using double Kato slides; midstream urine specimens were also collected for three consecutive days and tested for S. mansoni. The sensitivity of the urine-CCA cassette test was determined using combined results of six Kato-Katz thick smears and three urine-CCA cassette tests as gold standard. The specificity of the urine-CCA cassette test was evaluated in an area where schistosomiasis is not endemic. RESULTS: Prevalence of S. mansoni infection as determined by single urine-CCA cassette test was 65.9%, by single Kato-Katz smear 37.3% and by six Kato-Katz thick smears 53.1% (P < 0.001). A single urine-CCA cassette test was significantly (P < 0.001) more sensitive (89.1%), had a lower negative predictive value (78.2%), was more accurate (92.6%) and agreed better with the gold standard (k = 0.83) than one or six Kato-Katz thick smears. However, both the Kato-Katz and urine-CCA cassette test showed 100% specificity in endemic settings. CONCLUSIONS: In moderate and high prevalence areas, urine-CCA cassette test is more sensitive than the Kato-Katz method and can be used for screening and mapping of S. mansoni infection.


Assuntos
Antígenos de Helmintos/urina , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma mansoni/imunologia , Esquistossomose mansoni/diagnóstico , Animais , Anti-Helmínticos/uso terapêutico , Criança , Pré-Escolar , Técnicas de Laboratório Clínico , Estudos Transversais , Etiópia/epidemiologia , Fezes/parasitologia , Feminino , Glicoproteínas , Proteínas de Helminto , Humanos , Masculino , Contagem de Ovos de Parasitas , Praziquantel/uso terapêutico , Prevalência , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
15.
Korean J Parasitol ; 51(1): 93-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23467705

RESUMO

A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.


Assuntos
Antígenos de Helmintos/sangue , Antígenos de Helmintos/urina , Testes Diagnósticos de Rotina/métodos , Parasitologia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Animais , Anticorpos Anti-Helmínticos/isolamento & purificação , Anticorpos Monoclonais/isolamento & purificação , Humanos , Imunoensaio/métodos , Schistosoma mansoni/imunologia , Sensibilidade e Especificidade
16.
Artigo em Inglês | MEDLINE | ID: mdl-36700600

RESUMO

BACKGROUND: The World Health Organization recommends a market-ready, urine-based point-of-care diagnostic test for circulating cathodic antigens (CCA) to determine the prevalence of S. mansoni. This study evaluated the performance of the URINE CCA (SCHISTO) ECO TESTE® (POC-ECO), which is currently available in Brazil. METHODS: Residents from eight sites with different prevalence estimates provided one urine sample for POC-ECO and one stool sample for Kato-Katz (KK) and Helmintex® (HTX) testing as an egg-detecting reference for infection status. RESULTS: None of the study sites had significantly higher POC-ECO accuracy than KK. CONCLUSIONS: POC-ECO is not currently recommended in Brazilian schistosomiasis elimination programs.


Assuntos
Esquistossomose mansoni , Animais , Humanos , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/epidemiologia , Schistosoma mansoni , Brasil/epidemiologia , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Antígenos de Helmintos/urina , Prevalência , Fezes
17.
Rev Soc Bras Med Trop ; 56: e0341, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36820657

RESUMO

BACKGROUND: The long-term effects of schistosomiasis on the glomerulus may contribute to the development of chronic kidney disease. This study aimed to investigate baseline Schistosoma mansoni-Circulating Anodic Antigen (CAA) levels and their association with kidney biomarkers related to podocyte injury and inflammation in long-term follow-up after praziquantel (PZQ) treatment. METHODS: Schistosoma infection was diagnosed by detecting CAA in urine using a quantitative assay based on lateral flow using luminescent up-converting phosphor reporter particles. A cutoff threshold of 0.1 pg/mL CAA was used to diagnose Schistosoma infection (baseline) in a low-prevalence area in Ceará, Northeast, Brazil. Two groups were included: CAA-positive and CAA-negative individuals, both of which received a single dose of PZQ at baseline. Urinary samples from 55 individuals were evaluated before (baseline) and at 1, 2, and 3 years after PZQ treatment. At all time points, kidney biomarkers were quantified in urine and adjusted for urinary creatinine levels. RESULTS: CAA-positive patients had increased baseline albuminuria and proteinuria and showed greater associations between kidney biomarkers. CAA levels correlated only with Vascular Endothelial Growth Factor (VEGF) (podocyte injury) levels. Increasing trends were observed for malondialdehyde (oxidative stress), monocyte chemoattractant protein-1 (inflammation marker), and VEGF. In the follow-up analysis, no relevant differences were observed in kidney biomarkers between the groups and different periods. CONCLUSIONS: S. mansoni-infected individuals presented subclinical signs of glomerular damage that may reflect podocyte injury. However, no causal effect on long-term renal function was observed after PZQ treatment.


Assuntos
Podócitos , Esquistossomose mansoni , Animais , Humanos , Schistosoma mansoni , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Podócitos/química , Brasil/epidemiologia , Antígenos de Helmintos/urina , Praziquantel/uso terapêutico , Inflamação/tratamento farmacológico , Prevalência , Esquistossomose mansoni/complicações , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/tratamento farmacológico
18.
Front Immunol ; 13: 899311, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774791

RESUMO

Schistosomiasis remains to ha/ve a significant public health impact in the Philippines. The Kato-Katz (K-K) technique is the reference standard and most used technique for definitive diagnosis of intestinal schistosomiasis for control programs in endemic regions. However, this has a very low sensitivity when applied in areas of low endemicity and patients with light infection. Hence, this study determined the diagnostic performance of immunological, molecular, parasitological, and ultrasonographic tests in diagnosing intestinal schistosomiasis in endemic municipalities in the Philippines. We performed a community-based cross-sectional study to determine the positivity of schistosomiasis in Leyte, Philippines. The diagnostic performance of five different detection techniques: (1) three stool K-K with duplicate smears; (2) soluble egg antigen IgG ELISA; (3) urine point-of-care circulating cathodic antigen (POC-CCA) test; (4) detection of Schistosoma japonicum circulating DNA (SjcDNA) in serum and urine samples; (5) focused abdominal ultrasound (US), were also obtained in this study. Multiple stool examinations enhanced the sensitivity of K-K from 26.2% (95% CI [16.4, 38.8]) with single stool to 53.8% (95% CI [41.1, 66.1]) and 69.2% (95% CI [56.4, 80.0]) with two and three stools from consecutive days, respectively. Among the SjcDNA nucleic acid amplification test (NAAT)-based detection assays, loop-mediated isothermal amplification (LAMP) PCR using sera had the highest sensitivity at 92.3% (95% CI [82.2, 97.1]) with LAMP consistently identifying more positive cases in both serum and urine samples. This study showed that single stool K-K, which remains the only diagnostic test available in most endemic areas in the Philippines, had low sensitivity and failed to identify most patients with light infection. SjcDNA detection assay and POC-CCA urine test were more sensitive than stool microscopy in detecting schistosomiasis. On the other hand, US was less sensitive than the widely utilized K-K technique in diagnosing schistosomiasis. This study emphasizes the need to revisit the use of single stool K-K in the surveillance and case detection of schistosomiasis in endemic areas of the Philippines. The availability of advanced and more sensitive diagnostic tests will help better control, prevent, and eliminate schistosomiasis in the country.


Assuntos
Esquistossomose mansoni , Esquistossomose , Animais , Antígenos de Helmintos/urina , Cidades , Estudos Transversais , Humanos , Filipinas/epidemiologia , Sistemas Automatizados de Assistência Junto ao Leito , Prevalência , Schistosoma mansoni , Esquistossomose/diagnóstico , Esquistossomose/epidemiologia , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/epidemiologia , Sensibilidade e Especificidade
19.
Rev Soc Bras Med Trop ; 55: e0389, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35239906

RESUMO

BACKGROUND: The World Health Organization recommends reliable point-of-care (POC) diagnostic testing to eliminate schistosomiasis. Lateral flow immunoassay that detects schistosome circulating cathodic antigen (CCA) in urine to establish prevalence thresholds for intervention in endemic areas is recommended. Stored urine may be useful if surveying at-risk populations is delayed or interrupted by unforeseen circumstances, such as the current COVID-19 pandemic. This study evaluated the manufacturer's claim that Schistosoma mansoni infection can be reliably diagnosed in urine samples stored at -20°C for one year. METHODS: Two-hundred-forty-two subjects from an endemic site in Brazil provided one urine sample each for testing with URINE CCA (SCHISTO) ECO TESTE® (POC-ECO) and one stool sample each for testing with Kato-Katz (KK) and Helmintex® (HTX) as a robust reference standard for infection status. At least 2 ml of urine from each participant was stored at -20°C; after one year, 76 samples were randomly selected for POC-ECO retesting. RESULTS: The POC-ECO agreement between freshly collected and stored urine was inadequate considering trace results as positive (Cohen's kappa coefficient κ = 0.08) and negative (κ = 0.36). POC-ECO accuracy was not significantly greater than that of routine KK (54%; 95% confidence interval: 42.1%-65.5%). CONCLUSIONS: The precision and accuracy of POC-ECO have to be optimized in both freshly collected and stored urine before it can be recommended for use in control programs in Brazil.


Assuntos
COVID-19 , Esquistossomose mansoni , Animais , Antígenos de Helmintos/urina , Brasil/epidemiologia , Fezes , Humanos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Prevalência , Reprodutibilidade dos Testes , SARS-CoV-2 , Schistosoma mansoni , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/epidemiologia , Sensibilidade e Especificidade
20.
Trop Med Int Health ; 16(9): 1099-103, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21692957

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy of a circulating cathodic antigen (CCA) urine dipstick test for detecting Schistosoma mansoni and S. haematobium alongside an integrated rapid mapping survey in Southern Sudan. METHODS AND RESULTS: A total of 373 children aged 5-16 years were included in the study. Of these 26.0% were infected with S. haematobium and 24.5% were infected with S. mansoni, as identified by urine filtration or single Kato-Katz thick smear, respectively. The CCA performed moderately in detecting S. mansoni, with sensitivity of 89.1% and specificity of 74.2%, and poorly in detecting S. haematobium infections, with a sensitivity of 36.8% and specificity of 78.9%. This may be a slight underestimate of true CCA accuracy, since only single stool and urine samples were examined by microscopy. The true 'gold standard' for comparison would have been the collection of multiple stool samples over consecutive days. CONCLUSION: The poor CCA accuracy for diagnosis of urinary schistosomiasis means that this test is currently not suitable for rapid mapping of schistosomiasis in areas where both S. mansoni and S. haematobium may be endemic.


Assuntos
Antígenos de Helmintos/urina , Glicoproteínas/urina , Proteínas de Helminto/urina , Fitas Reagentes/normas , Esquistossomose Urinária/urina , Esquistossomose mansoni/urina , Adolescente , Animais , Criança , Pré-Escolar , Fezes/parasitologia , Feminino , Humanos , Masculino , Doenças Negligenciadas/epidemiologia , Contagem de Ovos de Parasitas , Schistosoma haematobium/imunologia , Schistosoma mansoni/imunologia , Esquistossomose Urinária/epidemiologia , Esquistossomose Urinária/imunologia , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/imunologia , Sensibilidade e Especificidade , Sudão/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA