Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 814
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Allergy ; 79(1): 128-141, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37766519

RESUMO

BACKGROUND: Epithelial barrier impairment is associated with many skin and mucosal inflammatory disorders. Laundry detergents have been demonstrated to affect epithelial barrier function in vitro using air-liquid interface cultures of human epithelial cells. METHODS: Back skin of C57BL/6 mice was treated with two household laundry detergents at several dilutions. Barrier function was assessed by electric impedance spectroscopy (EIS) and transepidermal water loss (TEWL) measurements after the 4 h of treatments with detergents. RNA sequencing (RNA-seq) and targeted multiplex proteomics analyses in skin biopsy samples were performed. The 6-h treatment effect of laundry detergent and sodium dodecyl sulfate (SDS) was investigated on ex vivo human skin. RESULTS: Detergent-treated skin showed a significant EIS reduction and TEWL increase compared to untreated skin, with a relatively higher sensitivity and dose-response in EIS. The RNA-seq showed the reduction of the expression of several genes essential for skin barrier integrity, such as tight junctions and adherens junction proteins. In contrast, keratinization, lipid metabolic processes, and epidermal cell differentiation were upregulated. Proteomics analysis showed that the detergents treatment generally downregulated cell adhesion-related proteins, such as epithelial cell adhesion molecule and contactin-1, and upregulated proinflammatory proteins, such as interleukin 6 and interleukin 1 beta. Both detergent and SDS led to a significant decrease in EIS values in the ex vivo human skin model. CONCLUSION: The present study demonstrated that laundry detergents and its main component, SDS impaired the epidermal barrier in vivo and ex vivo human skin. Daily detergent exposure may cause skin barrier disruption and may contribute to the development of atopic diseases.


Assuntos
Detergentes , Pele , Humanos , Camundongos , Animais , Detergentes/efeitos adversos , Detergentes/química , Detergentes/metabolismo , Camundongos Endogâmicos C57BL , Pele/metabolismo , Epiderme/metabolismo , Inflamação/metabolismo
2.
Dermatology ; 240(2): 233-242, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37939682

RESUMO

BACKGROUND: Detergent is a chemical product commonly used in people's daily life. Contact with detergent solutions can damage the human skin barrier and cause skin diseases. Skin surface lipids (SSLs) play a decisive role in skin barrier function. This study aimed to observe the changes of SSLs in young adults after exposure to detergent solutions to explore the underlying mechanism of skin barrier function damage. METHODS: A self-controlled study on youth adults was conducted in Zhengzhou, China, in November 2020. The study lasted for a total of 1 week, and skin barrier function was assessed by trans-epidermal water loss (TEWL) values. The changes of SSLs before and after exposure to the detergent with subjects were measured using ultra-performance liquid chromatography quadrupole time of flight mass spectrometry. RESULTS: The skin barrier function of subjects' hands was impaired after exposure to detergent (TEWL value increased, p < 0.001). A total of 520 SSLs were detected, divided into 6 main categories. The average relative abundance of these 6 major lipids decreased after exposure. Sphingolipids (mainly ceramides), free fatty acids (mainly long-chain fatty acids), cholesterol lipids, and glycerophospholipids are the most severely damaged lipids. CONCLUSION: Detergent solutions can damage the skin barrier function and SSLs of young hands; interventions targeting SSLs to eliminate detergent damage to human skin may be of value.


Assuntos
Detergentes , Lipidômica , Humanos , Adulto Jovem , Adolescente , Detergentes/efeitos adversos , Detergentes/análise , Pele , Epiderme/química , Água , Lipídeos/análise , Lipídeos/química , Lipídeos/farmacologia
3.
Pediatr Dermatol ; 41(3): 468-471, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38413219

RESUMO

Many baby cleansers are promoted as hypoallergic products; however, these claims are not typically validated. This study assessed the 50 best-selling baby cleansers from online retailer Amazon for potential allergens. We found that the presence of most marketing claims, including "hypoallergenic" or "allergy-tested," did not correlate with the number of potential allergens in a cleanser. Furthermore, the total number of marketing claims of a cleanser was positively correlated with the number of allergens, highlighting the discordance between marketing claims and allergen content in baby cleansers.


Assuntos
Alérgenos , Humanos , Alérgenos/efeitos adversos , Lactente , Prevalência , Dermatite Alérgica de Contato/etiologia , Detergentes/efeitos adversos , Cuidado do Lactente/métodos
4.
Dermatol Online J ; 30(3)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-39090047

RESUMO

are that the contents of this article are their own original unpublished findings. Title: Comparison of potential contact allergens in best-selling adult and baby cleansers Authors: Jayden Galamgam1 MD, Sasan D Noveir2 BA, Carol E Cheng1 MD Affiliations: 1Division of Dermatology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA, 2 David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA Corresponding Author: Jayden Galamgam MD, Division of Dermatology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, 10833 Le Conte Avenue, Los Angeles, CA 90095, Email: jgalamgam@mednet.ucla.edu.


Assuntos
Alérgenos , Humanos , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Adulto , Lactente , Detergentes/efeitos adversos
5.
Allergy ; 78(7): 1878-1892, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37163231

RESUMO

INTRODUCTION: Epidemiological studies demonstrated that cleaning work and frequent use of cleaning products are risk factors for asthma. Laundry detergents have been reported to have epithelial barrier-opening effects. However, whether laundry detergents directly induce airway inflammation and its mechanisms in vivo remain to be elucidated. METHODS: Two commercial laundry detergents and two commonly used surfactants for cleaning and cosmetics (sodium lauryl sulfate and sodium dodecyl benzene sulfonate) were intranasally administered to mice. Lungs were analyzed using flow cytometry, histology, ELISA, and quantitative PCR. Human bronchial epithelial cells were stimulated with laundry detergents and analyzed using quantitative PCR and western blotting. Involvement of oxidative stress was assessed using an antioxidant. Dust samples from homes were analyzed to determine their detergent content by measuring their critical micelle concentration (CMC). RESULTS: The administered laundry detergents and surfactants-induced eosinophilic airway inflammation accompanied by increased IL-33 expression and activation of group 2 innate lymphoid cells (ILC2s). Detergent-induced eosinophilic airway inflammation was significantly attenuated in Rag2-/- Il2rg-/- , Il33-/- mice, and also in wild-type mice treated with NAC. Detergent-induced IL-33 expression in airways was attenuated by NAC treatment, both in vivo and in vitro. CMCs were found in all of the tested dust extracts, and they differed significantly among the homes. CONCLUSION: The laundry detergents and surfactants-induced eosinophilic airway inflammation in vivo through epithelial cell and ILC2 activation. They induced IL-33 expression in airway epithelial cells through oxidative stress. Furthermore, detergent residues were present in house dust and are presumably inhaled into the airway in daily life.


Assuntos
Detergentes , Imunidade Inata , Humanos , Camundongos , Animais , Detergentes/efeitos adversos , Tensoativos/efeitos adversos , Linfócitos , Interleucina-33/farmacologia , Poeira , Inflamação
6.
Allergy ; 78(1): 192-201, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35899466

RESUMO

BACKGROUND: Eosinophilic esophagitis (EoE) is a chronic allergic disease associated with type 2 inflammation and epithelial barrier dysfunction. The etiology is unknown, however, genetic heritability studies suggest environmental factors play a key role in pathogenesis. Detergents, such as sodium dodecyl sulfate (SDS), are common ingredients in household products such as dish soap and toothpaste. We hypothesized detergent exposure decreases epithelial barrier function and induces esophageal inflammation. METHODS: Immortalized esophageal epithelial cells (EPC2) were cultured in air-liquid interface (ALI) and exposed to SDS. Barrier function/activity was assessed by transepithelial electrical resistance (TEER), FITC-dextran flux, and RT-PCR. Additionally, SDS-treated mouse esophageal organoids were evaluated for morphology. To investigate the effects of SDS in vivo, mice were treated with 0.5% SDS in drinking water for 14 days. Esophagi were assessed by gross morphology, histopathology, protein expression, and bulk RNA sequencing. RESULTS: When EPC2 cells were exposed to SDS (5 µg/ml) for 96 h, TEER decreased (p = 0.03), and FITC-dextran flux increased (p = 0.0002). mRNA expression of IL-33 increased 4.5-fold (p = 0.02) at 6 h and DSG1 decreased (p < 0.0001) by 72 h. Disrupted epithelial integrity was noted in SDS-treated esophageal organoids. When mice were exposed to SDS, they showed increased esophageal width, chemokine, and metalloprotease levels. Mice treated with SDS also showed increased IL-33 protein expression, basal zone hyperplasia, CD4+ cell infiltration, and esophageal eosinophilia. RNA sequencing revealed upregulation of immune response pathway genes. CONCLUSION: Exposure to SDS decreases esophageal barrier integrity, stimulates IL-33 production, and promotes epithelial hyperplasia and tissue eosinophilia. Detergents may be a key environmental trigger in EoE pathogenesis.


Assuntos
Detergentes , Esofagite Eosinofílica , Animais , Camundongos , Detergentes/efeitos adversos , Células Epiteliais/metabolismo , Hiperplasia/patologia , Inflamação/metabolismo , Interleucina-33/metabolismo
7.
Curr Allergy Asthma Rep ; 23(8): 443-451, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37233851

RESUMO

PURPOSE OF REVIEW: The prevalence and incidence of allergic disease have been rising in Westernized countries since the twentieth century. Increasingly, evidence suggests that damage to the epithelium initiates and shapes innate and adaptive immune responses to external antigens. The objective of this review is to examine the role of detergents as a potential risk factor for developing allergic disease. RECENT FINDINGS: Herein, we identify key sources of human detergent exposure. We summarize the evidence suggesting a possible role for detergents and related chemicals in initiating epithelial barrier dysfunction and allergic inflammation. We primarily focus on experimental models of atopic dermatitis, asthma, and eosinophilic esophagitis, which show compelling associations between allergic disease and detergent exposure. Mechanistic studies suggest that detergents disrupt epithelial barrier integrity through their effects on tight junction or adhesion molecules and promote inflammation through epithelial alarmin release. Environmental exposures that disrupt or damage the epithelium may account for the increasing rates of allergic disease in genetically susceptible individuals. Detergents and related chemical compounds represent possible modifiable risk factors for the development or exacerbation of atopy.


Assuntos
Asma , Dermatite Atópica , Esofagite Eosinofílica , Humanos , Detergentes/efeitos adversos , Inflamação
8.
Occup Environ Med ; 80(7): 361-371, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37137692

RESUMO

OBJECTIVES: This study investigated occupational risk factors and exposure-response relationships for airway disease among health workers (HWs) exposed to cleaning agents in two tertiary hospitals in South Africa and Tanzania. METHODS: In this cross-sectional study, 697 participants completed questionnaire interviews while 654 underwent fractional exhaled nitric oxide (FeNO) testing. Asthma Symptom Score (ASS) was computed based on the sum of answers to five questions on asthma-related symptoms in the past 12 months. For exposure-response analyses, cleaning agent-related self-reported exposure variables were categorised into three levels (cleaning product not used; use of a cleaning product for up to 99 min per week and use of a cleaning product for ≥100 min per week). RESULTS: Asthma-related outcomes (ASS and FeNO) demonstrated positive associations with medical instrument cleaning agents (orthophthalaldehyde and enzymatic cleaners) and tasks (instruments precleaning and changing sterilisation solutions) as well as patient care activities (disinfection prior to procedures and disinfecting wounds). A particularly pronounced dose-response relationship was observed between work-related ocular-nasal symptoms and medical instrument cleaning agents (orthophthalaldehyde, glutaraldehyde, enzymatic cleaners, alcohols and bleach) (OR range: 2.37-4.56) and tasks (OR range: 2.92-4.44). A strong association was also observed between ASS and use of sprays for fixed surface cleaning (mean ratio 2.81; 95% CI 1.41 to 5.59). CONCLUSIONS: Specific agents for medical instrument disinfection for example, orthophthalaldehyde and enzymatic cleaners, patient care activities and use of sprays are important occupational risk factors for airway disease among HWs.


Assuntos
Asma , Doenças Profissionais , Exposição Ocupacional , Transtornos Respiratórios , Humanos , Asma/diagnóstico , Estudos Transversais , Detergentes/efeitos adversos , Doenças Profissionais/induzido quimicamente , Doenças Profissionais/complicações , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Fatores de Risco , Centros de Atenção Terciária
9.
Contact Dermatitis ; 88(5): 372-382, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36727715

RESUMO

BACKGROUND: Glove occlusion might enhance skin sensitivity to a subsequent detergent challenge (occlusion effect). Thus, some skin protection creams (PC) claim to protect against this effect of occlusion, and are recommended to be used before wearing liquid-proof gloves. OBJECTIVES: To evaluate the effect of PC applied prior to glove occlusion on the 'occlusion effect'-refers to increased susceptibility of the skin to a model detergent. METHODS: One hundred and eleven volunteers were enrolled in a single-blind, randomized study. Seven PCs were applied before glove occlusion over 7 days (D1-D7). After sodium lauryl sulphate (SLS) challenge, we compared the irritation between the areas treated with PC and occlusion alone. Clinical scoring and bioengineering methods (capacitance, transepidermal water loss [TEWL], and colourimetry [erythema]) were used to quantify the irritant reactions. RESULTS: After 1 week of occlusion and PC application, we did not observe significant changes in TEWL, nor in erythema, whereas skin hydration raised in three cream-treated areas. On day 10, after a challenge with SLS, some products significantly aggravated the skin irritation as compared to occlusion alone. CONCLUSIONS: The 'occlusion effect'-shown as higher skin susceptibility to a model detergent-was not mitigated by PCs when applied prior to glove occlusion. On the contrary, some PCs might have negative effects on skin barrier function and augment such sensitivity.


Assuntos
Dermatite Alérgica de Contato , Dermatite Irritante , Humanos , Dermatite Irritante/etiologia , Dermatite Irritante/prevenção & controle , Método Simples-Cego , Detergentes/efeitos adversos , Pele , Dodecilsulfato de Sódio/efeitos adversos , Eritema/induzido quimicamente , Eritema/prevenção & controle , Emolientes , Água , Perda Insensível de Água
10.
Transfusion ; 62(9): 1752-1762, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35919958

RESUMO

BACKGROUND: Transfusion-related acute lung injury (TRALI) is a severe complication of plasma transfusion, though the use of solvent/detergent pooled plasma (SDP) has nearly eliminated reported TRALI cases. The goal of this study was to investigate the incidence of TRALI in intensive care units (ICU) following the replacement of quarantined fresh frozen plasma (qFFP) by SDP. STUDY DESIGN AND METHODS: A retrospective multicenter observational before-after cohort study was performed during two 6-month periods, before (April-October 2014) and after the introduction of SDP (April-October 2015), accounting for a washout period. A full chart review was performed for patients who received ≥1 plasma units and developed hypoxemia within 24 h. RESULTS: During the study period, 8944 patients were admitted to the ICU. Exactly 1171 quarantine fresh frozen plasma (qFFP) units were transfused in 376 patients, and respectively, 2008 SDP units to 396 patients after implementation. Ten TRALI cases occurred during the qFFP and nine cases occurred during the SDP period, in which plasma was transfused. The incidence was 0.85% (CI95%: 0.33%-1.4%) per unit qFFP and 0.45% (CI95%: 0.21%-0.79%, p = 0.221) per SDP unit. One instance of TRALI occurred after a single SDP unit. Mortality was 70% for patients developing TRALI in the ICU compared with 22% in patients receiving at least one plasma transfusion. CONCLUSION: Implementation of SDP lowered the incidence of TRALI in which plasma products were implicated, though not significantly. Clinically diagnosed TRALI can still occur following SDP transfusion. Developing TRALI in the ICU was associated with high mortality rates, therefore, clinicians should remain vigilant.


Assuntos
Lesão Pulmonar Aguda Relacionada à Transfusão , Transfusão de Componentes Sanguíneos/efeitos adversos , Estudos de Coortes , Detergentes/efeitos adversos , Humanos , Incidência , Unidades de Terapia Intensiva , Plasma , Estudos Retrospectivos , Solventes , Lesão Pulmonar Aguda Relacionada à Transfusão/epidemiologia
11.
J Asthma ; 59(4): 673-681, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33402006

RESUMO

BACKGROUND AND OBJECTIVES: Healthcare workers have an increased risk of respiratory symptoms and dermatitis, likely related to cleaning/disinfecting agents. The aim of this study was to identify work tasks and cleaning/disinfecting agents associated with respiratory symptoms and hand dermatitis among healthcare workers in a tertiary hospital. METHODS: Cleaning agent usage, respiratory symptoms and skin symptoms were recorded by participants using a questionnaire in a cross-sectional study. Age and sex adjusted odds ratios (OR) were used to examine associations between job tasks, exposures, respiratory, and skin outcomes. RESULTS: Two hundred and thirty healthcare workers who were exposed to cleaning agents were compared with 77 who had no, or minimal, exposure. Exposed workers had an increased risk of respiratory symptoms (adjusted OR = 2.17; 95% CI: 1.18-4.14) and skin symptoms (adjusted OR = 1.77; 95% CI: 1.00 - 3.17). Washing instruments manually, using aerosol products, cleaning operating rooms, cleaning sanitary rooms, preparing disinfectants, and filling devices with cleaning products were cleaning tasks associated with various respiratory symptoms. Bleach was the only cleaning agent associated with a respiratory symptom: tightness in the chest (unadjusted OR = 2.46; 95% CI: 1.01-6.89) but statistical significance did not persist after adjustment for age and sex. Hand dermatitis was associated with actual disinfecting tasks (adjusted OR = 2.19; 95% CI: 1.10-4.66). Bleach was the only cleaning agent significantly associated with hand dermatitis (adjusted OR = 2.54; 95% CI: 1.32-5.13). CONCLUSIONS: This study provides insight into possible work tasks that need interventions to reduce or prevent respiratory and skin symptoms in healthcare workers.


Assuntos
Asma , Dermatite , Doenças Profissionais , Exposição Ocupacional , Asma/etiologia , Estudos Transversais , Atenção à Saúde , Dermatite/complicações , Detergentes/efeitos adversos , Pessoal de Saúde , Humanos , Pulmão , Doenças Profissionais/epidemiologia , Doenças Profissionais/etiologia , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/efeitos adversos
12.
Contact Dermatitis ; 87(3): 241-246, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35357722

RESUMO

BACKGROUND: Increased hand hygiene measures during the COVID-19 pandemic have led to an increased quantum of hand eczema (HE). OBJECTIVES: To examine the effects of varying washing frequencies using current mild cleansing agents-alongside with the effect of a rehydrating cream-on the epidermal barrier function and inflammatory processes of the stratum corneum(SC). METHODS: Standardized skin washings on the volar aspects of the lower arms of skin-healthy volunteers were performed using the automated cleansing device either 5 or 11 times within 4 h for 60 s each with a standard cleanser, a lipid-containing syndet, or a lipid-containing syndet followed by one-time application of a rehydrating cream. Skin bioengineering parameters (transepidermal water loss, SC hydration, erythema, and SC pH) and biochemical/immunological parameters (interleukin-1α, interleukin-1α receptor antagonist and natural moisturizing factor) of SCsamples collected by tape stripping were assessed. RESULTS: All applied washing procedures provided comparable, mild effects on the epidermal barrier function and skin inflammation. CONCLUSION: Occupational skin cleansers seem to have improved regarding skin barrier damaging effects. To further corroborate this, a study design, modified on the basis of our findings, applying longer washing periods for consecutive days seems desirable.


Assuntos
COVID-19 , Dermatite Alérgica de Contato , Dermatite Alérgica de Contato/metabolismo , Detergentes/efeitos adversos , Emolientes , Epiderme/metabolismo , Desinfecção das Mãos , Humanos , Interleucina-1alfa/metabolismo , Interleucina-1alfa/farmacologia , Lipídeos/farmacologia , Pandemias , Pele , Perda Insensível de Água
13.
Arerugi ; 71(9): 1136-1142, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-36372425

RESUMO

Cocamidopropyl betaine (CAPB) is an amphoteric surfactant. It has several functions, including producing effervescence and washing effects, and thus, it is used in many cleansing products, such as shampoo and liquid body cleansers. Recently, it has become clear that some impurities that arise during the manufacturing process can have sensitizing effects. Herein, we report a case of allergic contact dermatitis caused by detergents containing CAPB, in which an impurity was determined to be the possible causative agent by patch testing and chemical analysis.A 64-year-old Japanese female developed a skin rash on the hairlines of her forehead and nuchal region one month before her first visit to our clinic. Later, the rashes, which were composed of desquamative erythema, expanded to her face, neck, upper back, and chest. Patch tests produced positive results for a shampoo and liquid body cleanser (1% aq.) that she had used as well as for CAPB (1% aq.); lauramidopropyl betaine (LAPB) (1% aq.); and lauramidopropyl dimethylamine (LAPDMA) (0.05% aq.), which is an impurity of CAPB. The rashes resolved completely after we instructed her to use products without CAPB and LAPB. When issuing such instructions, clinicians should have correct knowledge about surfactants, such as the differences between cosmetic ingredient names and quasi-drug ingredient names.


Assuntos
Betaína , Dermatite Alérgica de Contato , Humanos , Feminino , Pessoa de Meia-Idade , Betaína/efeitos adversos , Detergentes/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro/efeitos adversos , Testes do Emplastro/métodos , Tensoativos
14.
Occup Environ Med ; 78(4): 293-295, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33563606

RESUMO

BACKGROUND: Exposure to cleaning and disinfection products has been associated with respiratory disorders such as asthma in cleaning and healthcare workers. Safety data sheets (SDSs) provide information on hazardous chemicals that are present in products to help users with risk assessment and implement appropriate control measures. However, they have potential limitations in identifying respiratory hazards due to a lack of regulatory test methods for respiratory sensitisation and irritation of chemicals. METHODS: SDSs were first used to identify chemicals on the database as respiratory sensitisers and irritants. A quantitative structure-activity relationship (QSAR) model and an asthmagen list established by the Association of Occupational and Environmental Clinics (AOEC) were used to identify potential respiratory sensitisers and irritants (by the AOEC list only) in the cleaning and disinfection products. RESULTS: From a total of 459 cleaning and disinfection products used in healthcare organisations across England and Wales, 35 respiratory sensitisers not labelled as such on the SDS were identified by QSAR or AOEC. Only 2% of cleaning and disinfection products contained at least one respiratory sensitiser as identified by their SDSs; this was increased to 37.7% of products when the QSAR or the AOEC list was used. CONCLUSIONS: A significantly higher proportion of cleaning products contain respiratory hazardous chemicals, particularly respiratory sensitisers than would be expected from the information provided by SDSs alone. Cleaners and healthcare workers may, therefore, be insufficiently protected.


Assuntos
Asma/induzido quimicamente , Detergentes/efeitos adversos , Desinfetantes/efeitos adversos , Substâncias Perigosas/efeitos adversos , Instalações de Saúde , Irritantes/efeitos adversos , Exposição Ocupacional/efeitos adversos , Inglaterra , Humanos , Fichas de Dados de Segurança de Materiais , Relação Estrutura-Atividade , País de Gales
15.
Regul Toxicol Pharmacol ; 126: 105044, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34506879

RESUMO

The inter-laboratory performance of Isolated Chicken Eye (ICE) histopathology scoring was assessed for predicting EU CLP/UN GHS Cat. 1 surfactants. Furthermore, the predictive capacity of ICE histopathology was evaluated for the combined dataset of surfactants and existing data for non-extreme pH (2 < pH < 11.5) detergents. Use of ICE histopathology led to increased sensitivity compared to the ICE test method alone for surfactants. When combined with the existing dataset of detergents, use of histopathology in addition to the standard ICE test method decreased the false negative rates from 64% (14/22) to 27% (6/22); increased accuracy from 53% (16/30) to 77% (23/30); and led to acceptable level of false positives (from 0/8 to 1/8 (12.5%). Moreover, good reproducibility of ICE histopathology predictions conducted on the same slides was found between pathologists and peer-reviewers from three independent laboratories (10/12 or 83%) and over time. Use of ICE histopathology was therefore found suitable to predict EU CLP/UN GHS Cat. 1 surfactants and non-extreme pH detergents. In addition, appropriate reproducibility of ICE histopathology was found, provided that i) an internal peer-review system was in place; ii) original slides were assessed to enable evaluation of three dimensional effects; and iii) appropriate training and proficiency appraisal were conducted.


Assuntos
Detergentes/efeitos adversos , Traumatismos Oculares/induzido quimicamente , Patologia/métodos , Tensoativos/efeitos adversos , Animais , Galinhas , Reações Falso-Negativas , Reações Falso-Positivas , Concentração de Íons de Hidrogênio , Patologia/normas , Reprodutibilidade dos Testes , Nações Unidas
16.
J Paediatr Child Health ; 57(12): 1912-1916, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34129255

RESUMO

AIM: We aimed to evaluate the epidemiological characteristic and clinical features of laundry detergent capsule (LDC) exposure in children. METHODS: Retrospective review of medical records of patients hospitalised due to the exposure to LDC at the Department of Paediatrics and Gastroenterology, Medical University of Lublin, Poland, from 2014 to 2019 was conducted. RESULTS: During the study period, 38 children including 19 (50%) boys and 19 (50%) girls were admitted to our department due to exposure to LDC. The age of patients ranged from 11 months to 9 years, with a mean 48.61 ± 28.85 months of age. About 66% of patients were younger than 5 years. The major route of exposure was ingestion (n = 37; 97%). Most patients (n = 27; 71%) exhibited symptoms of exposure to the LDC. The most common symptoms were vomiting (n = 23; 60%), cough (n = 7; 18%) and salivation (n = 5; 13%). Seven patients required gastroscopy. Abnormalities were subsequently identified in three children. CONCLUSIONS: Accidental exposure to LDC usually occurs in children younger than 5 years. Although the majority of cases had mild or moderate clinical outcomes, ingestion of LDC may lead to some severe consequences. Improvements in parental education regarding the risks of LDC, and in the packaging of LDC may prevent serious injury.


Assuntos
Detergentes , Vômito , Cápsulas , Criança , Detergentes/efeitos adversos , Feminino , Humanos , Lactente , Masculino , Embalagem de Produtos , Estudos Retrospectivos , Vômito/induzido quimicamente
17.
Contact Dermatitis ; 85(6): 643-649, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34387868

RESUMO

BACKGROUND: In the 2010s an epidemic of allergic contact dermatitis to methylisothiazolinone (MI) occurred in Europe. European authorities banned the use of methylisothiazolinone in leave-on cosmetics in 2017 and limited its use in rinse-off products in 2018. OBJECTIVES: To investigate the sensitization rate to MI in Belgium between January 2014 and December 2019, and to assess cosensitizations to octylisothiazolinone (OIT) and benzisothiazolinone (BIT) in MI-sensitized patients. METHODS: A retrospective study of patch test results with MI, OIT, and BIT observed in patients attending five Belgian hospitals. RESULTS: Overall, 560 of 10 029 patients (5.58%) had a positive patch test reaction to MI, and its sensitization rate decreased from 7.9% in 2014 to 3.1% in 2019. Rinse-off cosmetics, paints, and detergents were the most prevalent sensitization sources in recent years. Simultaneous reactions readily occurred to OIT, and, surprisingly, and increasingly, also to BIT. CONCLUSIONS: Contact allergy to MI in Belgium has reached a pre-epidemic level, reflecting the impact of recent regulatory measures. Leave-on cosmetics, in contrast to rinse-off products, have almost disappeared as sensitization sources in Europe. Paints and detergents also remain problematic. The remarkably high number of patients (co)sensitized to BIT should be a focus of future research.


Assuntos
Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Tiazóis/efeitos adversos , Adolescente , Adulto , Idoso , Bélgica/epidemiologia , Criança , Pré-Escolar , Cosméticos/efeitos adversos , Detergentes/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pintura/efeitos adversos , Testes do Emplastro , Estudos Retrospectivos , Adulto Jovem
18.
Adv Skin Wound Care ; 34(9): 488-492, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34415253

RESUMO

ABSTRACT: Acute traumatic wound cleansing is currently a controversial issue demonstrated by the variability in solutions and techniques used to clean wounds in clinical practice. Although there is evidence of improved infection outcomes in wounds cleansed with antiseptics, these observations are often undermined by concurrent use of antibiotics in addition to poor study design. Cleansing techniques including pressurized irrigation have also been investigated indicating potential harms such as edema and inconsistencies in irrigation pressures. The purpose of this article is to provide a narrative review on the contemporary evidence indicating the potential harms and benefits of wound cleansing in the context of acute traumatic wounds.This literature review reveals that acute wound cleansing in clinical practice remains heavily dependent on tradition rather than robust clinical evidence. The evidence base remains limited because of methodological and pragmatic issues in obtaining definitive data on the efficacy of specific agents and techniques. Future studies should focus on establishing the relative benefits of different cleansing solutions and techniques. Establishing the most effective use of antiseptic cleansing solutions may also help reduce further antimicrobial resistance as observed in recent studies. Clinicians responsible for cleansing wounds must consider patient preference when deciding which solution and techniques are used. In addition, a risk assessment considering the potential harms and benefits of different solutions and techniques must be performed.


Assuntos
Detergentes/efeitos adversos , Detergentes/farmacologia , Cicatrização/efeitos dos fármacos , Ferimentos e Lesões/tratamento farmacológico , Humanos
19.
Occup Environ Med ; 77(10): 728-731, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32699009

RESUMO

Specific inhalation challenge (SIC) is the reference standard for the diagnosis of occupational asthma. Current guidelines for identifying late asthmatic reactions are not evidence based. OBJECTIVES: To identify the fall in forced expiratory volume in 1 s (FEV1) required following SIC to exceed the 95% CI for control days, factors which influence this and to show how this can be applied in routine practice using a statistical method based on the pooled SD for FEV1 from three control days. METHODS: Fifty consecutive workers being investigated for occupational asthma were asked to self-record FEV1 hourly for 2 days before admission for SIC. These 2 days were added to the in-hospital control day to calculate the pooled SD and 95% CI. RESULTS: 45/50 kept adequate measurements. The pooled 95% CI was 385 mL (SD 126), or 14.2% (SD 6.2) of the baseline FEV1, but was unrelated to the baseline FEV1 (r=0.06, p=0.68), or gender, atopy, smoking, non-specific reactivity or treatment before or during SIC. Thirteen workers had a late asthmatic reaction with ≥2 consecutive FEV1 measurements below the 95% CI for pooled control days, 4/13 had <15% and 9/13 >15% late fall from baseline. The four workers with ≥2 values below the 95% CI all had independent evidence of occupational asthma. CONCLUSION: The pooled SD method for defining late asthmatic reactions has scientific validity, accounts for interpatient spirometric variability and diurnal variation and can identify clinically relevant late asthmatic reactions from smaller exposures. For baseline FEV1 <2.5 L, a 15% fall is within the 95% CI.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica/métodos , Fatores de Tempo , Acrilatos/efeitos adversos , Adulto , Aldeídos/efeitos adversos , Aminas/efeitos adversos , Análise de Variância , Asma/fisiopatologia , Testes de Provocação Brônquica/estatística & dados numéricos , Detergentes/efeitos adversos , Desinfetantes/efeitos adversos , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Isocianatos/efeitos adversos , Masculino , Plásticos/efeitos adversos
20.
Am J Respir Crit Care Med ; 197(9): 1157-1163, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29451393

RESUMO

RATIONALE: Cleaning tasks may imply exposure to chemical agents with potential harmful effects to the respiratory system, and increased risk of asthma and respiratory symptoms among professional cleaners and in persons cleaning at home has been reported. Long-term consequences of cleaning agents on respiratory health are, however, not well described. OBJECTIVES: This study aimed to investigate long-term effects of occupational cleaning and cleaning at home on lung function decline and airway obstruction. METHODS: The European Community Respiratory Health Survey (ECRHS) investigated a multicenter population-based cohort at three time points over 20 years. A total of 6,235 participants with at least one lung function measurement from 22 study centers, who in ECRHS II responded to questionnaire modules concerning cleaning activities between ECRHS I and ECRHS II, were included. The data were analyzed with mixed linear models adjusting for potential confounders. MEASUREMENTS AND MAIN RESULTS: As compared with women not engaged in cleaning (ΔFEV1 = -18.5 ml/yr), FEV1 declined more rapidly in women responsible for cleaning at home (-22.1; P = 0.01) and occupational cleaners (-22.4; P = 0.03). The same was found for decline in FVC (ΔFVC = -8.8 ml/yr; -13.1, P = 0.02; and -15.9, P = 0.002; respectively). Both cleaning sprays and other cleaning agents were associated with accelerated FEV1 decline (-22.0, P = 0.04; and -22.9, P = 0.004; respectively). Cleaning was not significantly associated with lung function decline in men or with FEV1/FVC decline or airway obstruction. CONCLUSIONS: Women cleaning at home or working as occupational cleaners had accelerated decline in lung function, suggesting that exposures related to cleaning activities may constitute a risk to long-term respiratory health.


Assuntos
Obstrução das Vias Respiratórias/fisiopatologia , Asma/fisiopatologia , Detergentes/efeitos adversos , Volume Expiratório Forçado/fisiologia , Pulmão/fisiopatologia , Exposição Ocupacional/efeitos adversos , Adulto , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA