Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.530
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Ophthalmology ; 131(3): 310-321, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37839561

RESUMO

PURPOSE: To characterize focal biomechanical alterations in subclinical keratoconus (SKC) using motion-tracking (MT) Brillouin microscopy and evaluate the ability of MT Brillouin metrics to differentiate eyes with SKC from normal control eyes. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Thirty eyes from 30 patients were evaluated, including 15 eyes from 15 bilaterally normal patients and 15 eyes with SKC from 15 patients. METHODS: All patients underwent Scheimpflug tomography and MT Brillouin microscopy using a custom-built device. Mean and minimum MT Brillouin values within the anterior plateau region and anterior 150 µm were generated. Scheimpflug metrics evaluated included inferior-superior (IS) value, maximum keratometry (Kmax), thinnest corneal thickness, asymmetry indices, Belin/Ambrosio display total deviation, and Ambrosio relational thickness. Receiver operating characteristic (ROC) curves were generated for all Scheimpflug and MT Brillouin metrics evaluated to determine the area under the ROC curve (AUC), sensitivity, and specificity for each variable. MAIN OUTCOME MEASURES: Discriminative performance based on AUC, sensitivity, and specificity. RESULTS: No significant differences were found between groups for age, sex, manifest refraction spherical equivalent, corrected distance visual acuity, Kmax, or KISA% index. Among Scheimpflug metrics, significant differences were found between groups for thinnest corneal thickness (556 µm vs. 522 µm; P < 0.001), IS value (0.29 diopter [D] vs. 1.05 D; P < 0.001), index of vertical asymmetry (IVA; 0.10 vs. 0.19; P < 0.001), and keratoconus index (1.01 vs. 1.05; P < 0.001), and no significant differences were found for any other Scheimpflug metric. Among MT Brillouin metrics, clear differences were found between control eyes and eyes with SKC for mean plateau (5.71 GHz vs. 5.68 GHz; P < 0.0001), minimum plateau (5.69 GHz vs. 5.65 GHz; P < 0.0001), mean anterior 150 µm (5.72 GHz vs. 5.68 GHz; P < 0.0001), and minimum anterior 150 µm (5.70 GHz vs. 5.66 GHz; P < 0.001). All MT Brillouin plateau and anterior 150 µm mean and minimum metrics fully differentiated groups (AUC, 1.0 for each), whereas the best performing Scheimpflug metrics were keratoconus index (AUC, 0.91), IS value (AUC, 0.89), and IVA (AUC, 0.88). CONCLUSIONS: Motion-tracking Brillouin microscopy metrics effectively characterize focal corneal biomechanical alterations in eyes with SKC and clearly differentiated these eyes from control eyes, including eyes that were not differentiated accurately using Scheimpflug metrics. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Microscopia , Estudos Transversais , Estudos Prospectivos , Paquimetria Corneana
2.
Ophthalmology ; 131(1): 107-121, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855776

RESUMO

PURPOSE: To review the published literature on the diagnostic capabilities of the newest generation of corneal imaging devices for the identification of keratoconus. METHODS: Corneal imaging devices studied included tomographic platforms (Scheimpflug photography, OCT) and functional biomechanical devices (imaging an air impulse on the cornea). A literature search in the PubMed database for English language studies was last conducted in February 2023. The search yielded 469 citations, which were reviewed in abstract form. Of these, 147 were relevant to the assessment objectives and underwent full-text review. Forty-five articles met the criteria for inclusion and were assigned a level of evidence rating by the panel methodologist. Twenty-six articles were rated level II, and 19 articles were rated level III. There were no level I evidence studies of corneal imaging for the diagnosis of keratoconus found in the literature. To provide a common cross-study outcome measure, diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were extracted. (A perfect diagnostic test that identifies all cases properly has an AUC of 1.0.) RESULTS: For the detection of keratoconus, sensitivities for all devices and parameters (e.g., anterior or posterior corneal curvature, corneal thickness) ranged from 65% to 100%. The majority of studies and parameters had sensitivities greater than 90%. The AUCs ranged from 0.82 to 1.00, with the majority greater than 0.90. Combined indices that integrated multiple parameters had an AUC in the mid-0.90 range. Keratoconus suspect detection performance was lower with AUCs ranging from 0.66 to 0.99, but most devices and parameters had sensitivities less than 90%. CONCLUSIONS: Modern corneal imaging devices provide improved characterization of the cornea and are accurate in detecting keratoconus with high AUCs ranging from 0.82 to 1.00. The detection of keratoconus suspects is less accurate with AUCs ranging from 0.66 to 0.99. Parameters based on single anatomic locations had a wide range of AUCs. Studies with combined indices using more data and parameters consistently reported high AUCs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Oftalmologia , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Ceratocone/diagnóstico por imagem , Curva ROC , Tomografia
3.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1017-1039, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37418053

RESUMO

PURPOSE: This review was designed to compare different corneal imaging modalities using artificial intelligence (AI) for the diagnosis of keratoconus (KCN), subclinical KCN (SKCN), and forme fruste KCN (FFKCN). METHODS: A comprehensive systematic search was conducted in scientific databases, including Web of Science, PubMed, Scopus, and Google Scholar based on the PRISMA statement. Two independent reviewers assessed all potential publications on AI and KCN up to March 2022. The Critical Appraisal Skills Program (CASP) 11-item checklist was used to evaluate the validity of the studies. Eligible articles were categorized into three groups (KCN, SKCN, and FFKCN) and included in the meta-analysis. The pooled estimate of accuracy (PEA) was calculated for all selected articles. RESULTS: The initial search yielded 575 relevant publications, of which 36 met the CASP quality criteria and were included in the analysis. Qualitative assessment showed that Scheimpflug and Placido combined with biomechanical and wavefront evaluations improved KCN detection (PEA, 99.2, and 99.0, respectively). The Scheimpflug system (92.25 PEA, 95% CI, 94.76-97.51) and a combination of Scheimpflug and Placido (96.44 PEA, 95% CI, 93.13-98.19) had the highest diagnostic accuracy for the detection of SKCN and FFKCN, respectively. The meta-analysis outcomes showed no significant difference between the CASP score and accuracy of the publications (all P > 0.05). CONCLUSIONS: Simultaneous Scheimpflug and Placido corneal imaging methods provide high diagnostic accuracy for early detection of keratoconus. The use of AI models improves the discrimination of keratoconic eyes from normal corneas.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Inteligência Artificial , Córnea , Paquimetria Corneana , Curva ROC
4.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 143-148, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37493776

RESUMO

PURPOSE: To compare corneal tomographic parameters between Hispanic White and non-Hispanic White patients using Pentacam data. METHODS: This retrospective study evaluated preoperative Pentacam data from 641 patients 50 years or older who underwent surgery for senile cataract and self-identified as Hispanic or non-Hispanic White. Patients of non-White race or multiethnic groups, or a history of surgery, trauma, or any abnormality of the cornea or anterior segment were excluded. Cornea and anterior segment parameters, as measured with Pentacam, were then compared between Hispanics and non-Hispanics. RESULTS: There were 352 Hispanic White and 289 non-Hispanic White patients. These included 231 men and 410 women, with a mean age of 69.5 ± 8.2 years. There were no significant differences between Hispanics and non-Hispanics in front or back keratometry or amount of front astigmatism. However, Hispanics had a greater amount of back astigmatism (0.36 ± 0.19 vs 0.32 ± 0.17 diopter, P = 0.04). Moreover, there was a statistically significant difference in front steep axis of the left eyes between Hispanics and non-Hispanics (97.8 ± 47.9 vs 108.2 ± 48.9 deg, P = 0.01), and a marginally significant difference in front steep axis of the right eyes (81.0 ± 48.2 vs 73.5 ± 49.9 deg, P = 0.06). Hispanics also had a lower vertex pachymetry (548.1 ± 34.5 vs 553.4 ± 37.4 µm, P = 0.04) and a smaller anterior chamber volume (134.7 ± 39.0 vs 146.1 ± 39.9 mm3, P < 0.001). CONCLUSIONS: There are some differences in cornea and anterior segment parameters between Hispanics and non-Hispanics 50 years or older who underwent surgery for senile cataract. However, such differences may not be clinically significant.


Assuntos
Astigmatismo , Catarata , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Topografia da Córnea/métodos , Córnea , Catarata/diagnóstico , Paquimetria Corneana
5.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1567-1578, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38150029

RESUMO

PURPOSE: To assess the differences and similarities in the corneal curvature obtained by two swept-source optical coherence tomography (SS-OCT) devices, Scheimpflug imaging system and one ray tracing aberrometer in patients with cataracts. Moreover, this study aimed to compare the differences in posterior corneal (PK), total corneal (TK) and true net power (TNP) measurements among the IOLMaster 700, CASIA2, and Pentacam. METHODS: A total of 200 eyes of 200 patients (116 female, 58%) were enrolled in this study, with a mean age of 65.9 ± 9.5 years. The flattest (Kf), steepest (Ks), and mean cornal powers (Km), J0, and J45 were obtained using two SS-OCT-based biometric devices, one rotating camera system and one ray-tracing aberrometer. The PK, TK and TNP values were also measured using these devices. To evaluate the differences and similarities between the devicves, the Friedman test, Pearson correlation coefficient (r), intraclass coefficient correlation (ICC) and Bland‒Altman plots with 95% limits of agreement (LoA) were used, and boxplots and stacked histograms were generated to describe the distributions of the data. RESULTS: There were no significant differences between the IOLMaster 700 and Pentacam for any of the keratometry values. Additionally, there were no significant differences between the IOLMaster 700 and iTrace in evaluating J0 and J45. Bland‒Altman plots revealed relatively wide LoA widths, almost larger than 1 diopter for the keratometry values and almost larger than 0.5 diopter for J0 and J45 values among the four devices. In terms of PK and TK values, significant differences and low ICCs were found among the three devices. CONCLUSIONS: Although strong correlations and good agreement were found among the IOLMaster700, CASIA2, Pentacam and iTrace for Kf, Ks, Km and J0, J45, it seems that the measurements should not be used interchangeably because of the wide LoA widths and the presence of significant differences among the devices. Similarly, due to significant differences and low ICCs, the PK, TK and TNP values obtained by IOLMaster 700, CASIA2, and Pentacam should not be used interchangeably.


Assuntos
Catarata , Tomografia de Coerência Óptica , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Córnea , Catarata/diagnóstico , Biometria , Topografia da Córnea/métodos
6.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2533-2539, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38456928

RESUMO

PURPOSE: This study aimed to estimate the corneal keratometric index in the eyes of cataract surgery patients who received zero-power intraocular lenses (IOLs). METHODOLOGY: This retrospective study analyzed postoperative equivalent spherical refraction and axial length, mean anterior curvature radius and aqueous humor refractive index to calculate the theoretical corneal keratometric index value (nk). Data was collected from 2 centers located in France and Germany. RESULTS: Thirty-six eyes were analyzed. The results revealed a mean corneal keratometric index of 1.329 ± 0.005 for traditional axial length (AL) and 1.331 ± 0.005 for Cooke modified axial length (CMAL). Results ranged from minimum values of 1.318/1.320 to maximum values of 1.340/1.340. CONCLUSION: The corneal keratometric index is a crucial parameter for ophthalmic procedures and calculations, particularly for IOL power calculation. Notably, the estimated corneal keratometric index value of 1.329/1.331 in this study is lower than the commonly used 1.3375 index. These findings align with recent research demonstrating that the theoretical corneal keratometric index should be approximately 1.329 using traditional AL and 1.331 using CMAL, based on the ratio between the mean anterior and posterior corneal curvature radii (1.22).


Assuntos
Extração de Catarata , Córnea , Lentes Intraoculares , Refração Ocular , Humanos , Estudos Retrospectivos , Feminino , Masculino , Refração Ocular/fisiologia , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/patologia , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Topografia da Córnea/métodos , Implante de Lente Intraocular , Desenho de Prótese , Seguimentos , Biometria/métodos
7.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2189-2198, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38349421

RESUMO

PURPOSE: To compare corneal haze between active ulcer and healed scarring using a Scheimpflug densitometry. MATERIALS AND METHODS: A prospective longitudinal study enrolled 30 patients (30 eyes) with ulcerative keratitis (UK). Each subject's corneal optical density (COD) was measured with a Scheimpflug corneal densitometry, Pentacam® AXL (Oculus GmbH, Wetzlar, Germany), at the active ulcerative and complete scarring stage. The COD data were analyzed through distinct methods (inbuilt, sorted annular partitions, and ulcer-matching densitometric maps). We compared different CODs to select the better index for clinically monitoring the transition from corneal ulceration to healed scar. RESULTS: The CODs of the periphery (P = 0.0024) and outside of the active ulcer (P = 0.0002) significantly decreased after scarring. Partitioning the cornea into different depths and annular zones, the anterior layer, center layer, and the 2-6 mm annular zone had a more remarkable COD decrease after scar formation. The 3rd-sorted COD in the anterior layer revealed the highest area under the receiver-operating characteristic curves (0.709), in which 90% of subjects had COD reduction during the ulcer-to-scar transition. CONCLUSIONS: Aside from subjective judgment based on clinical signs, the Scheimpflug tomography-based densitometry could provide objective and efficient monitoring of the corneal opacity evolution in UK patients. Because the 3rd-sorted annular COD is a better index than the inbuilt or mapping CODs in differentiating active ulcers from healed scars, this COD could be a clinically promising parameter to monitor the progression of UK patients.


Assuntos
Córnea , Úlcera da Córnea , Densitometria , Humanos , Estudos Prospectivos , Feminino , Masculino , Densitometria/métodos , Pessoa de Meia-Idade , Úlcera da Córnea/diagnóstico , Córnea/patologia , Córnea/diagnóstico por imagem , Seguimentos , Adulto , Cicatrização , Cicatriz/diagnóstico , Cicatriz/etiologia , Idoso , Curva ROC , Acuidade Visual , Topografia da Córnea/métodos , Opacidade da Córnea/diagnóstico , Opacidade da Córnea/etiologia , Opacidade da Córnea/fisiopatologia
8.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1839-1845, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38217766

RESUMO

PURPOSE: To assess the accuracy of intraocular lens (IOL) power formulas, namely, SRK/T, Haigis, Barrett Universal II, Barrett True-K for keratoconus, Kane formula, and Kane formula for keratoconus, for cataract with keratoconus in Japanese eyes. SETTING: Five surgical sites in Japan. DESIGN: A retrospective case series. METHODS: Eyes with keratoconus undergoing cataract surgery were included. Postoperative refraction was compared with the prediction by the formulas. Visual acuity, manifest spherical equivalent, prediction error (PE), and mean absolute errors (MAEs) were determined 1 month postoperatively. The PE within 0.50 diopter (D), 1.00 D, and 2.00 D were compared between IOL formulas. Subgroup analysis based on the steepest keratometry (stage 1, ≤ 48 D; stage 2, > 48 D and ≤ 53 D; and stage 3, > 53 D) was performed. The relationship between PE and preoperative biometric data were assessed. RESULTS: Fifty eyes were included. The MAE of the Barrett True-K for keratoconus, Kane keratoconus, and Kane formulas were significantly lower than that of Haigis. A statistically significant difference in the prediction accuracy within ± 0.50 D was found between Kane keratoconus and Haigis. The prediction accuracy of the Barrett True-K for keratoconus, SRK/T, and Kane within ± 1.00 D was statistically significant compared with that of Haigis. In stage 3, the Barrett True-K for keratoconus had a significantly lower MAE than SRK/T and Haigis. CONCLUSION: Keratoconus-specific formulas were more accurate than existing formulas in Japanese eyes. The Barrett True-K formula for keratoconus had higher prediction accuracy in severe keratoconus.


Assuntos
Topografia da Córnea , Ceratocone , Lentes Intraoculares , Refração Ocular , Acuidade Visual , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/cirurgia , Estudos Retrospectivos , Feminino , Japão/epidemiologia , Refração Ocular/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Topografia da Córnea/métodos , Adulto , Biometria/métodos , Óptica e Fotônica , Idoso , Córnea/patologia , Córnea/cirurgia , Seguimentos
9.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2551-2560, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38502350

RESUMO

PURPOSE: To quantitatively evaluate the morphological parameters of meibomian glands (MGs) and lipid layer thickness (LLT) in patients with keratoconus (KC). METHODS: In this prospective, cross-sectional study, 164 eyes of 164 keratoconus patients and 64 eyes of 64 age-matched control subjects were included. An advanced automatic MG analyzer was used to quantitatively measure the morphological and functional parameters of MGs. Morphological and functional parameters of MGs, LLT, and other ocular surface parameters were compared between the control and KC groups. RESULTS: The mean meibomian gland diameter, length, square, and gland area ratio (GA) were all significantly decreased in the KC group (all P < 0.05), while no significant difference was observed in the gland tortuosity index (TI) and gland signal index (SI) between the KC and control groups (all P > 0.05). There was no significant difference in the number of total and incomplete blinking among patients with different stages of keratoconus (all P > 0.05). The gland diameter, square, and TI were all negatively associated with KC severity (all P < 0.05), while no significant difference was observed among all stages of KC in gland length, GA, and SI (all P > 0.05). Moreover, the LLTs were positively correlated with the gland diameter, square, GA, and TI and negatively correlated with anterior corneal curvature or KC severity (all P < 0.05). CONCLUSIONS: Atrophic morphological changes in the meibomian glands were closely correlated with the severity of keratoconus. Gland diameter may be a sensitive functional morphology metric of meibomian glands in patients with keratoconus.


Assuntos
Ceratocone , Glândulas Tarsais , Lágrimas , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Glândulas Tarsais/patologia , Glândulas Tarsais/metabolismo , Glândulas Tarsais/fisiopatologia , Glândulas Tarsais/diagnóstico por imagem , Masculino , Estudos Transversais , Feminino , Estudos Prospectivos , Adulto , Lágrimas/metabolismo , Adulto Jovem , Lipídeos , Córnea/patologia , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Pessoa de Meia-Idade , Adolescente , Piscadela/fisiologia
10.
BMC Ophthalmol ; 24(1): 138, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539111

RESUMO

PURPOSE: To assess the level of agreement and evaluate the reliability of measurements between two Scheimpflug imaging modalities, Scansys (MediWorks, China) and Sirius (CSO, Italy), in quantifying the anterior segment parameters in healthy eyes. METHODS: In a cross-sectional study, the right eyes of 38 healthy participants without any ocular or systemic diseases were examined. A range of anterior segment parameters including anterior and posterior flat and steep keratometry, central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), anterior chamber angle (ACA), corneal volume, anterior chamber volume, and horizontal white to white diameter, derived from the sagittal curvature maps were measured. To evaluate the reliability of the measurements, intraclass correlation coefficient (ICC) and correlation coefficient were measured. Additionally, Bland-Altman plots were employed to examine the agreement in mean (bias line) and 95% limits of agreement between the two devices. RESULTS: The mean age was 31.5 ± 6.9 (range: 19-47) years. The ICC indicated that the majority of anterior segment parameters had an excellent or good level of reliability, surpassing the threshold of 0.9. Nevertheless, CCT and ACA exhibited a moderate level of reliability, with ICC values of 0.794 and 0.728, respectively. The correlation analysis showed a strong correlation for all the variables tested. The Bland-Altman plots revealed that the bias line was near zero and the 95% limits of agreement were narrow for most variables, except for the anterior flat and steep keratometry, which were found to range from - 0.57 to 0.84 D and - 0.68 to 0.87 D, respectively. CONCLUSION: Scansys and Sirius devices can be effectively used interchangeably for the evaluation of most anterior segment parameters; however, for anterior corneal curvatures, CCT and ACA, their alternative use is not recommended.


Assuntos
Córnea , Tomografia , Humanos , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Estudos Transversais , Estudos Prospectivos , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Tomografia de Coerência Óptica
11.
BMC Ophthalmol ; 24(1): 266, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38907184

RESUMO

BACKGROUND: This study aims to investigate relative peripheral refractive (RPR) characteristics in children with non-amblyopic myopic anisometropia and explore potential associations between relative peripheral refractive errors (RPRE) and myopia. METHODS: Relative peripheral refractive errors were assessed in 64 children diagnosed with non-amblyopic myopic anisometropia utilizing multispectral refraction topography (MRT). Two eyes of each patient were divided into into the more myopia eyes group (ME) and the fellow eyes group (FE). Evaluated parameters encompassed total defocus values (TRDV), defocus values at eccentricities spanning 0 to 15 degrees (RDV-15), 0 to 30 degrees (RDV-30), 0 to 45 degrees (RDV-45), as well as superior (RDV-S), inferior (RDV-I), temporal (RDV-T), and nasal (RDV-N) positions. RESULTS: The study revealed a noteworthy contrast in TRDV values between Group ME (0.52 ± 0.36) and Group FE (0.17 ± 0.41), with a substantial significance (P < 0.0001). While no significant RDV-15 difference emerged between Group ME (0.01 ± 0.05) and Group FE (-0.01 ± 0.07) (P > 0.05), a meaningful RDV-30 difference existed between Group ME (0.11 ± 0.14) and Group FE (0.03 ± 0.19) (P = 0.0017). A significant discrepancy in RDV-45 was also observed between Group ME (0.39 ± 0.29) and Group FE (0.13 ± 0.34) (P < 0.001). Notably, RDV-I and RDV-T positions demonstrated marked differences between Group ME and Group FE (P < 0.0001), whereas no significant disparity was noted in RDV-S and RDV-N positions (P > 0.05). CONCLUSION: Eyes exhibiting greater myopia manifested more hyperopic peripheral defocus in the context of anisometropia. MRT as a novel ophthalmic evaluation technique, holds promising potential for broader clinical applications in the future.


Assuntos
Anisometropia , Miopia , Refração Ocular , Acuidade Visual , Humanos , Anisometropia/fisiopatologia , Anisometropia/complicações , Masculino , Feminino , Miopia/fisiopatologia , Miopia/complicações , Criança , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Topografia da Córnea/métodos , Adolescente , Pré-Escolar
12.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009964

RESUMO

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Assuntos
Topografia da Córnea , Ceratocone , Fotografação , Curva ROC , Humanos , Ceratocone/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Adulto , Gana , Topografia da Córnea/métodos , Fotografação/métodos , Adulto Jovem , Adolescente , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Miopia/diagnóstico , Astigmatismo/diagnóstico , Acuidade Visual
13.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
14.
BMC Ophthalmol ; 24(1): 351, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39155380

RESUMO

PURPOSE: To investigate the repeatability and reproducibility of a new method for centration analysis after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK). METHODS: This study comprised 29 eyes treated with SMILE and 24 with FS-LASIK. Decentrations were analyzed using tangential and pachymetry difference maps respectively. Both difference maps were generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Repeatability and reproducibility were evaluated by calculating the intraclass correlation coefficient (ICC), within-subject standard deviation (Sw), and coefficient of repeatability (CR). RESULTS: ICC, Sw, and CR showed good to excellent repeatability in locating the coordinates of the optical zone (OZ) center on both maps, with values ranging from 0.84 to 0.96, 0.03 to 0.13, and 0.08 to 0.36 respectively. The repeatability of the total decentration from the preoperative corneal vertex on the tangential curvature difference maps( d TC ) and the pachymetry difference maps( d PC ) were moderate and good, respectively. The ICC, Sw, and CR of d TC were 0.63, 0.09, and 0.25, respectively. The ICC, Sw, and CR of d PC were 0.77, 0.10, and 0.28, respectively. The reproducibility of the OZ center measurements was excellent for the tangential difference maps (ICC ≥ 0.97 ) and good for the pachymetry difference maps (ICC ≥ 0.86). ICC, Sw, and CR showed excellent reproducibility of d TC , with values of 0.95, 0.03, and 0.08, respectively. ICC, Sw, and CR showed good reproducibility of d PC , with values of 0.89, 0.06, and 0.17, respectively. CONCLUSION: The centration analysis method used in this study showed good to excellent repeatability and reproducibility in locating the coordinates of the center of the OZ on the tangential and pachymetry difference maps.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Refração Ocular , Humanos , Reprodutibilidade dos Testes , Feminino , Adulto , Masculino , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Adulto Jovem , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/patologia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Paquimetria Corneana/métodos , Lasers de Excimer/uso terapêutico , Acuidade Visual , Cirurgia da Córnea a Laser/métodos , Pessoa de Meia-Idade , Período Pós-Operatório
15.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38389207

RESUMO

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Assuntos
Lentes de Contato , Topografia da Córnea , Ceratocone , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Adulto , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Refração Ocular/fisiologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
16.
Ophthalmic Physiol Opt ; 44(5): 884-893, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38778634

RESUMO

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.


Assuntos
Lentes de Contato Hidrofílicas , Sensibilidades de Contraste , Topografia da Córnea , Estudos Cross-Over , Ceratocone , Acuidade Visual , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Masculino , Feminino , Estudos Prospectivos , Adulto , Acuidade Visual/fisiologia , Adulto Jovem , Sensibilidades de Contraste/fisiologia , Topografia da Córnea/métodos , Pessoa de Meia-Idade , Desenho de Equipamento , Refração Ocular/fisiologia
17.
Clin Exp Ophthalmol ; 52(1): 22-30, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37963802

RESUMO

BACKGROUND: This study investigated the prevalence, risk factors and severity of corneal tomographic features of keratoconus in Down syndrome (DS). Additionally, previous studies indicate anomalous corneal features in DS, without keratoconus, this study characterised corneal features in DS without keratoconus. METHODS: This prospective observational study included participants with DS ≥10 years old. Keratoconus diagnosis, risk factors and corneal tomographic characteristics were recorded. Participants underwent slit-lamp biomicroscopy, Scheimpflug corneal tomography, corneal topography and autorefraction. A diagnosis of keratoconus (DS-KC), suspect keratoconus (DS-SK) and non-keratoconus (DS-NK) was made based on expert review of scans by three fellowship trained anterior segment ophthalmologists. Corneal tomography parameters from one eye of each participant were analysed. RESULTS: Keratoconus affected 50 (26.3%) of 190 participants, diagnosed by corneal tomography, topography or slit-lamp signs. Corneal hydrops affected 14.0% of DS-KC participants. Eye rubbing was a significant risk factor for keratoconus (p = 0.036). 175 (92%) participants could undertake corneal tomography of which tomography assessment alone identified 47 (26.9%) DS-KC participants, 64 (36.6%) DS-SK participants and 64 (36.6%) DS-NK participants. Significant differences (p < 0.001) were identified when the DS-KC, DS-SK and DS-NK groups were compared in maximum keratometry and posterior elevation at the thinnest point respectively: median (interquartile range) 50.20 (10.30D), 47.60 (1.95D), 46.50 (2.40D); 24.0 (38.00 µm), 10.00 (13.75 µm), 8.00 (6.00 µm). The DS-SK and DS-NK cohorts had similar minimum pachymetry, however, had several significantly different parameters among which included greater maximum keratometry, posterior elevation at the thinnest point in the DS-SK group. CONCLUSIONS: Keratoconus is common in DS. Keratoconus screening with corneal tomography is recommended for early detection.


Assuntos
Síndrome de Down , Ceratocone , Criança , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos , Síndrome de Down/complicações , Síndrome de Down/diagnóstico , Síndrome de Down/epidemiologia , Ceratocone/complicações , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Prevalência , Fatores de Risco , Tomografia , Estudos Prospectivos
18.
Clin Exp Ophthalmol ; 52(6): 627-638, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38741026

RESUMO

BACKGROUND: To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism. METHODS: Retrospective single centre study involving 150 eyes treated with a toric IOL (Alcon SN6AT, DFT or TFNT). Measurements included IOLMaster 700 keratometry (IOLMK) and total keratometry (IOLMTK), Pentacam keratometry (PK) and total corneal refractive power in 3 and 4 mm zones (PTCRP3 and PTCRP4), and Aladdin keratometry (AK). Regression-based models mapping the measured C0 and C45 components (Alpin's method) to reconstructed corneal astigmatism were derived. RESULTS: Mean C0 components were 0.50/0.59/0.51 dioptres (D) for IOLMK/PK/AK; 0.2/0.26/0.31 D for IOLMTK/PTCRP3/PTCRP4; and 0.26 D for reconstructed corneal astigmatism. All corresponding C45 components ranged around 0. The prediction models had main diagonal elements lower than 1 with some crosstalk between C0 and C45 (nonzero off-diagonal elements). Root-mean-squared residuals were 0.44/0.45/0.48/0.51/0.50/0.47 D for IOLMK/IOLMTK/PK/PTCRP3/PTCRP4/AK. CONCLUSIONS: Results from the different modalities are not consistent. On average IOLMTK/PTCRP3/PTCRP4 match reconstructed corneal astigmatism, whereas IOLMK/PK/AK show systematic C0 offsets of around 0.25 D. IOLMTK/PTCRP3/PTCRP4. Prediction models can reduce but not fully eliminate residual astigmatism after toric IOL implantation.


Assuntos
Astigmatismo , Biometria , Córnea , Topografia da Córnea , Implante de Lente Intraocular , Refração Ocular , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Estudos Retrospectivos , Masculino , Biometria/métodos , Refração Ocular/fisiologia , Feminino , Córnea/diagnóstico por imagem , Córnea/patologia , Idoso , Pessoa de Meia-Idade , Topografia da Córnea/métodos , Lentes Intraoculares , Segmento Anterior do Olho/diagnóstico por imagem , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Facoemulsificação , Adulto
19.
Eye Contact Lens ; 50(3): 138-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181218

RESUMO

OBJECTIVE: To compare the outcomes of corneal tomography obtained with an anterior-to-posterior segment optical coherence tomography device (Revo, Optopol Technologies Sp. z o.o.) and a rotating Scheimpflug camera (Pentacam AXL, Oculus Optikgeräte, Wetzlar, Germany). METHODS: In healthy subjects, agreement in stereometric parameters commonly used in cataract and refractive surgery was assessed. Comparison between the devices was performed using correlation coefficients, the Bland-Altman method, and a paired t test. RESULTS: Results of right eyes of 78 patients (47 women) aged 25.24±5.56 years were analyzed. The flat and steep anterior keratometry values were significantly higher for Revo than Pentacam (43.65±1.58 D vs. 42.99±1.47 D; P = 0.000, and 44.53±1.57 D vs. 43.82±1.49 D; P =0.000, respectively) and showed excellent correlation ( r =0.978 and 0.974, respectively). The results for maximal keratometry manifested a higher difference (45.89±1.69 D vs. 44.27±1.51 D for Revo and Pentacam, P =0.000) but were also strongly correlated ( r =0.871). Revo showed significantly lower corneal thickness values than Pentacam, both for apex pachymetry (535.54±32.45 vs. 550.74±31.55 µm; P =0.000) and for thinnest pachymetry (522.58±32.16 vs. 547.25±31.95 µm; P =0.000). The correlation coefficients for anterior and posterior corneal elevation at the thinnest point showed weak positive correlation ( r =0.179 and 0.185), while the correlation for corneal asphericity was moderate ( r =0.317). CONCLUSIONS: There was a significant difference between keratometric values obtained with Revo and the Pentacam AXL, although the measurements showed excellent correlation. Similar results were found for corneal thickness measurements, but not for corneal surface elevation and corneal asphericity.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos
20.
Eye Contact Lens ; 50(3): 121-125, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345011

RESUMO

PURPOSE: Determine the pediatric prevalence of keratoconus (KC) using Scheimpflug corneal tomography. METHODS: A prospective observational study was done on subjects aged 3 to 18 years at the Princeton Vision Clinic, Chicago, IL. Scheimpflug tomography (Pentacam HR, OCULUS Optikgerate GmbH) scans (Belin/Ambrósio Enhanced Ectasia BAD3) yielded BAD Final D (Final D) and Back Elevation at the Thinnest Point (BETP) measurements. Criteria differentiating non-KC from KC suspects & KC were, Non-KC -Final D <2.00 in both eyes; KC suspect -Final D ≥2.00 and <3.00 in combination with BETP ≥18 µm for myopia and ≥28 µm for hyperopia/mixed astigmatism in at least one eye; and KC -Final D of ≥3.00 with BETP ≥18 µm for myopia or ≥28 µm for hyperopia/mixed astigmatism in at least one eye. Two thousand two hundred and six subjects were recorded, removing duplicate and poor-quality scans leaving 2007 subjects. RESULTS: Of 2007 subjects, six were classified as KC -prevalence of 1:334, three subjects were KC suspects -prevalence of 1:669, and total prevalence of KC suspects and KC was 1:223. CONCLUSION: The prevalence of KC in children is higher than previously reported, emphasizing the importance of sensitive screening for KC at its earliest manifestation as standard in pediatric comprehensive eye examinations.


Assuntos
Astigmatismo , Hiperopia , Ceratocone , Miopia , Criança , Humanos , Chicago/epidemiologia , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Miopia/diagnóstico , Miopia/epidemiologia , Prevalência , Curva ROC , Tomografia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA