Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1312: 342780, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38834272

RESUMO

BACKGROUND: The convenient preparation and application of functionalized organic-inorganic hybrid monolithic materials have obtained substantial interest in the pretreatment of complex samples by solid-phase extraction (SPE). Compared to the in-tube solid-phase microextraction in fused-silica capillaries, micro SPE in plastic pipette tips have fascinating merits for the easily operated enrichment of trace target analytes from biological samples. However, the poor compatibility of organic-inorganic hybrid monoliths with plastics leads to the rare appearance of commercial hybrid monolithic pipette tips (HMPTs). Therefore, how to synthesize the organic-inorganic hybrid monolithic materials with better extraction performance in plastic pipette tips becomes a challenge. RESULTS: We develop a facile and cheap strategy to immobilize organic-inorganic hybrid monoliths in pipette tips. Melamine sponge was employed as the supporting skeleton to in situ assemble amine- and thiol-bifunctionalized hybrid monolithic material via "one pot" in a pipette tip, and gold nanoparticles (GNPs) and thiol-modified aptamer against human α-thrombin were sequentially attached to the hybrid monolith within the HMPTs. The average coverage density of the aptamer with GNPs as an intermediary reached as high as 818.5 pmol µL-1. The enriched thrombin concentration was determined by a sensitive enzymatic chromogenic assay with the limit of detection of 2 nM. The extraction recovery of thrombin at 10 nM in human serum was 86.1 % with a relative standard deviation of 6.1 %. This proposed protocol has been applied to the enrichment and determination of thrombin in real serum sample with strong anti-interference ability, low limit of detection and high recovery. SIGNIFICANCE: The amine- and thiol-bifunctionalized HMPTs prepared with sponge as the skeleton frame provided a novel substrate material to decorate aptamers for efficient enrichment of proteins. This enlightens us that we can take advantage of the tunability of sponge assisted HMPTs to produce and tailor a variety of micro SPE pipette tips for broader applications on the analysis of trace targets in complex biological, clinic and environmental samples.


Assuntos
Aptâmeros de Nucleotídeos , Trombina , Triazinas , Triazinas/química , Triazinas/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Humanos , Trombina/análise , Trombina/isolamento & purificação , Ouro/química , Nanopartículas Metálicas/química , Extração em Fase Sólida/métodos
2.
J Chromatogr A ; 1727: 464978, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38788401

RESUMO

A novel azo-linked porous organic polymer (AL-POP) was synthesized from caffeic acid and benzidine via an azo-coupling reaction and characterized by FTIR, SEM-EDS, BET, TGA, XRD and zeta potential analysis. AL-POPs were incorporated into melamine sponges and used for pipette tip micro solid-phase extraction (PT-MSPE) of six types of B vitamins (including thiamine, riboflavin, nicotinamide, pyridoxine, folic acid, and cyanocobalamin). After extraction, the samples were analyzed using high performance liquid chromatography-diode array detection (HPLC-DAD) system. The effect of AL-POP composition on the extraction efficiency (EE) of vitamins was investigated and benzidine to caffeic acid mol ratio of 1.5, 3.35 mmol of NaNO2, and reaction time of 8 h were selected as optimum conditions. The efficiency of the extraction process was improved by optimizing various parameters such as the amount of sorbent, pH and ionic strength of the sample, sample volume, number of sorption and desorption cycles, type of wash solvent, and type and volume of eluent solvent. Linearity (R2≥0.9987), Limit of detection (LOD) (11.88-18.97 ng/mL), limit of quantification (LOQ) (39.62-63.23 ng/mL), and enrichment factor (EF) (1.27-4.31) were obtained using calibration curves plotted under optimum conditions. Recovery values of these six B vitamins in the spiked multivitamin syrup samples varied from 80.01% to 108.35%, with a relative standard deviation (RSD) below 5.44%. Eventually, the optimized method was successfully used to extract and quantify the B vitamins in multivitamin syrup and non-alcoholic beer.


Assuntos
Limite de Detecção , Triazinas , Complexo Vitamínico B , Triazinas/análise , Triazinas/química , Triazinas/isolamento & purificação , Porosidade , Cromatografia Líquida de Alta Pressão/métodos , Complexo Vitamínico B/análise , Complexo Vitamínico B/química , Complexo Vitamínico B/isolamento & purificação , Adsorção , Polímeros/química , Compostos Azo/análise , Compostos Azo/química , Compostos Azo/isolamento & purificação , Microextração em Fase Sólida/métodos , Extração em Fase Sólida/métodos , Concentração de Íons de Hidrogênio
3.
J Chromatogr A ; 1730: 465124, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38959657

RESUMO

Polymer monoliths can be polymerised within different molds, but limited options are available for the preparation of free-standing polymer monoliths for analytical sample preparation, and in particular, solid-phase extraction (SPE). Commercial melamine-formaldehyde sponges can be used as supports for the preparation of polymer monoliths, due its flexibility, giving various shapes to monoliths. Herein, the crosslinker/porogen ratio of highly porous sponge-nested divinylbenzene (DVB) polymer monoliths has been evaluated. Monoliths prepared using different crosslinker/porogen ratios were applied to the extraction of bisphenol F, bisphenol A, bisphenol AF, and bisphenol B. Monoliths containing 50 wt % DVB and 50 wt % porogens presented the highest recovery of bisphenols. Under the optimised conditions, the developed method showed a linear range between 2.5 µg L-1 and 150 µg L-1 for BPA and BPAF, and between 5 µg L-1 and 150 µg L-1 for BPB and BPF. The limits of detection (LOD, S/N = 3) and limits of quantification (LOQ, S/N = 10) ranged from 0.36 µg L-1 to 1.09 µg L-1, and from 1.20 µg L-1 to 3.65 µg L-1, respectively. The recoveries for spiked bisphenols (10 µg L-1) in tap water and water contained in a polycarbonate containers were between 82 % and 114 %.


Assuntos
Compostos Benzidrílicos , Limite de Detecção , Fenóis , Extração em Fase Sólida , Triazinas , Extração em Fase Sólida/métodos , Compostos Benzidrílicos/análise , Compostos Benzidrílicos/isolamento & purificação , Fenóis/análise , Fenóis/isolamento & purificação , Triazinas/análise , Triazinas/isolamento & purificação , Triazinas/química , Polímeros/química , Porosidade , Reagentes de Ligações Cruzadas/química , Compostos de Vinila/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Reprodutibilidade dos Testes , Cromatografia Líquida de Alta Pressão/métodos
4.
J Chromatogr A ; 1730: 465078, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38889582

RESUMO

A novel fluorinated triazine-based covalent organic frameworks (F-CTFs) was designed and synthesized by using melamine and 2,3,5,6-tetrafluoroterephthalaldehydeas as organic ligands for selective pipette tip solid-phase extraction (PT-SPE) of amphiphilic fluoroquinolones (FQs). The competitive adsorption experiment and mechanism study were carried out and verified that this F-CTFs possesses favorable adsorption affinity for FQs. The abundant fluorine affinity sites endowed the F-CTFs high selectivity to FQs extraction through F-F interactions. The adsorption capacity of F-CTFs can reach up to 109.1 mg g-1 for enrofloxacin. The detailed characterization of the F-CTFs adsorbent involved the application of various techniques to examine its morphology and structure. Under optimized conditions, a method combining F-CTF-based PT-SPE with high-performance liquid chromatography (PT-SPE-HPLC) was established, which exhibited a broad linear range, excellent precision, and an impressively low limit of detection, and could be used for the determination of six FQs in milk, with LODs as low as 0.0010 µg mL-1. The recovery rates during extraction varied between 92.1% and 111.4%, exhibiting RSDs below 6.8% at different spiked concentrations.


Assuntos
Fluoroquinolonas , Limite de Detecção , Estruturas Metalorgânicas , Leite , Extração em Fase Sólida , Triazinas , Leite/química , Fluoroquinolonas/isolamento & purificação , Fluoroquinolonas/análise , Fluoroquinolonas/química , Triazinas/química , Triazinas/isolamento & purificação , Extração em Fase Sólida/métodos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Adsorção , Estruturas Metalorgânicas/química
5.
J Chromatogr A ; 1731: 465194, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39047443

RESUMO

Over the last decade, human activities in the industrial and agricultural sectors have significantly increased the concentration of persistent and harmful pollutants in aquatic ecosystems. The use of microorganisms is a green strategy for the bio-removal of certain contaminants. However, other pollutants in the same ecosystems can reduce their degrading activity and even affect their survival. Therefore, this study aimed to evaluate the efficiency of benzo(b)fluoranthene (BbF) and benzo(k)fluoranthene (BkF) removal by Selenastrum capricornutum in the presence of triazine herbicides, compounds mainly used in broadleaf weeds. The interest of this work focused on identifying in which of the microalgal components the degrading activity is best evidenced and affected. For this purpose, the use of solid-phase extraction (SPE) and matrix solid-phase dispersion (MSPD) extraction procedures and HPLC-UV analysis allowed the BbF and BkF trace quantification in biomass, liquid medium, and cell lysate separately from cultures exposed to these polycyclic aromatic hydrocarbons (PAHs) alone or with herbicides. The recovery percentages were between 78 and 94 %, good linearity (r2 ≈ 0.99), precision values measured as RSD < 15 %, and limits of detection (LOQs) at levels of ng mL-1 and ng mg-1 were obtained. The individual PAH amounts measured in the components of microalgae cultures show similar removal kinetics (removal percentages: 82-89 %). Likewise, the analysis demonstrated that the removal of PAHs is not affected in the presence of triazine herbicides (atrazine and cyanazine) and with similar removal percentages (79-86 %) compared to those cultures exposed to individual PAHs (74-83 %). These results support the possible real-world applications of PAH removal by extracts from S. capricornutum in aquatic environments contaminated with PAHs and near agriculture areas where triazine herbicides are used.


Assuntos
Fluorenos , Herbicidas , Microalgas , Extração em Fase Sólida , Triazinas , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Herbicidas/análise , Herbicidas/isolamento & purificação , Triazinas/análise , Triazinas/isolamento & purificação , Microalgas/química , Microalgas/metabolismo , Fluorenos/análise , Fluorenos/química , Fluorenos/isolamento & purificação , Poluentes Químicos da Água/análise , Biodegradação Ambiental
6.
J Chromatogr A ; 1726: 464977, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38735117

RESUMO

A magnetic molecularly imprinted polymer (MMIP) adsorbent incorporating amino-functionalized magnetite nanoparticles, nitrogen-doped graphene quantum dots and mesoporous carbon (MIP@MPC@N-GQDs@Fe3O4NH2) was fabricated to extract triazine herbicides from fruit juice. The embedded magnetite nanoparticles simplified the isolation of the adsorbent from the sample solution. The N-GQDs and MPC enhanced adsorption by affinity binding with triazines. The MIP layer provided highly specific recognition sites for the selective adsorption of three target triazines. The extracted triazines were determined by high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD). The developed method exhibited linearity from 1.5 to 100.0 µg L-1 with a detection limit of 0.5 µg L-1. Recoveries from spiked fruit juice samples were in the range of 80.1- 108.4 %, with a relative standard deviation of less than 6.0 %. The developed MMIP adsorbent demonstrated good selectivity, high extraction efficiency, ease of fabrication and use, and good stability.


Assuntos
Carbono , Sucos de Frutas e Vegetais , Herbicidas , Limite de Detecção , Polímeros Molecularmente Impressos , Pontos Quânticos , Triazinas , Pontos Quânticos/química , Triazinas/química , Triazinas/análise , Triazinas/isolamento & purificação , Herbicidas/análise , Herbicidas/isolamento & purificação , Herbicidas/química , Sucos de Frutas e Vegetais/análise , Adsorção , Polímeros Molecularmente Impressos/química , Carbono/química , Cromatografia Líquida de Alta Pressão/métodos , Nanopartículas de Magnetita/química , Microextração em Fase Sólida/métodos , Impressão Molecular/métodos , Porosidade , Grafite/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA