Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.251
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Mol Cell Cardiol ; 193: 11-24, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38797242

RESUMO

Atrial fibrillation (AF) is the most common cardiac rhythm disorder, often occurring in the setting of atrial distension and elevated myocardialstretch. While various mechano-electrochemical signal transduction pathways have been linked to AF development and progression, the underlying molecular mechanisms remain poorly understood, hampering AF therapies. In this review, we describe different aspects of stretch-induced electro-anatomical remodeling as seen in animal models and in patients with AF. Specifically, we focus on cellular and molecular mechanisms that are responsible for mechano-electrochemical signal transduction and the development of ectopic beats triggering AF from pulmonary veins, the most common source of paroxysmal AF. Furthermore, we describe structural changes caused by stretch occurring before and shortly after the onset of AF as well as during AF progression, contributing to longstanding forms of AF. We also propose mechanical stretch as a new dimension to the concept "AF begets AF", in addition to underlying diseases. Finally, we discuss the mechanisms of these electro-anatomical alterations in a search for potential therapeutic strategies and the development of novel antiarrhythmic drugs targeted at the components of mechano-electrochemical signal transduction not only in cardiac myocytes, but also in cardiac non-myocyte cells.


Assuntos
Fibrilação Atrial , Humanos , Animais , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/metabolismo , Fibrilação Atrial/patologia , Remodelamento Atrial , Átrios do Coração/fisiopatologia , Átrios do Coração/patologia , Átrios do Coração/metabolismo , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Transdução de Sinais , Veias Pulmonares/patologia , Veias Pulmonares/metabolismo , Veias Pulmonares/fisiopatologia , Fenômenos Eletrofisiológicos
2.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38511484

RESUMO

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Assuntos
Fibrilação Atrial , Criocirurgia , Desenho de Equipamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Cateteres Cardíacos , Duração da Cirurgia , Agulhas , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Frequência Cardíaca , Potenciais de Ação
3.
J Cardiovasc Electrophysiol ; 35(6): 1165-1173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571287

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Sedação Consciente , Frequência Cardíaca , Veias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fatores de Tempo , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Cateteres Cardíacos , Intervalo Livre de Progressão , Fatores de Risco
4.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433316

RESUMO

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Veias Pulmonares , Humanos , Potenciais de Ação , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Temperatura , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
5.
J Cardiovasc Electrophysiol ; 35(7): 1412-1421, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38750671

RESUMO

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.


Assuntos
Fibrilação Atrial , Índice de Massa Corporal , Criocirurgia , Estudos de Viabilidade , Obesidade , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/efeitos adversos , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Fatores de Tempo , Obesidade/diagnóstico , Obesidade/complicações , Obesidade/fisiopatologia , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Frequência Cardíaca , Índice de Gravidade de Doença , Potenciais de Ação , Estudos Retrospectivos , Recidiva
6.
J Cardiovasc Electrophysiol ; 35(7): 1429-1439, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38757241

RESUMO

INTRODUCTION: Cryoballoon ablation is a safe and efficient rhythm control strategy in atrial fibrillation (AF) patients. The impact of time from diagnosis to ablation is unclear. The aim of this study was to examine the impact of timing of first-time cryoballoon ablation on AF recurrence in a nationwide cohort of AF patients. METHODS AND RESULTS: From nationwide registers, all AF patients ≥18 years of age who underwent first-time AF cryoballoon ablation in Denmark from 2012 to 2018 were included. The AF patients were stratified by ablation timing: Early group (≤1 year after AF diagnosis), intermediate group (1-3 years after AF diagnosis), and late group (≥3 years after AF diagnosis). By adjusted Cox regression models, the effect of timing on AF recurrence was examined. This study included 1064 AF patients with a median age of 63 years. Most patients were male (66%) and had paroxysmal AF (67%). The 1-year risk of AF recurrence increased from 31% in the early group to 41% and 44% in the intermediate and late group. The hazard ratios (95% confidence intervals) were 1.28 (0.95, 1.74) in the intermediate group and 1.42 (1.09, 1.86) in the late group when compared to the early group. Continuous diagnosis-to-ablation time seemed to have the greatest impact on AF recurrence within the first 2 years. CONCLUSION: In AF patients undergoing cryoballoon ablation, late timing of ablation was associated with a significantly higher AF recurrence rate when compared to early timing of ablation. These findings support early cryoballoon ablation to improve the outcomes after ablation.


Assuntos
Fibrilação Atrial , Criocirurgia , Frequência Cardíaca , Recidiva , Sistema de Registros , Tempo para o Tratamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Criocirurgia/efeitos adversos , Feminino , Dinamarca/epidemiologia , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Fatores de Tempo , Medição de Risco , Resultado do Tratamento , Potenciais de Ação , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
7.
J Cardiovasc Electrophysiol ; 35(7): 1461-1470, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38769635

RESUMO

INTRODUCTION: This study sought to elucidate the impact of vein of Marshall (VOM) chemical ablation on atrial fibrillation (AF) drivers by investigating the changes in CARTOFINDER mappings before and after VOM chemical ablation in patients with persistent AF. METHODS: This study included 23 consecutive patients undergoing catheter ablation for long-persistent AF (>18 months). VOM chemical ablation was performed following pulmonary vein isolation. CARTOFINDER and AF cycle length (AFCL) maps were created in the left atrium (LA) before and after VOM chemical ablation. The LA was divided into 8 segments, and the number of focal activation points with 6 or more repetitions was counted in each segment. RESULTS: The number of focal activation points was largest in the LA appendage (LAA). After VOM chemical ablation, the number of focal activation points in the LA decreased significantly (37 [interquartile range, IQR: 19-55] vs. 15 [IQR: 7-21], p < .001), and median AFCL was significantly prolonged (159 [147-168] vs. 164 [150-173] ms, p < .001). In the assessment of each segment, significant decreases in focal activation points were observed in the inferior, lateral, and anterior segments and LAA. Among the focal activation points disappearing after chemical ablation, the number in the non-ethanol-affected area was significantly larger than that in the affected area (13 [8-25] vs. 4 [1-10], p < .001). CONCLUSIONS: VOM chemical ablation decreases AF drivers detected by CARTOFINDER. Mechanisms other than direct myocardial damage are considered to contribute the attenuation of AF drivers.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Valor Preditivo dos Testes , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Fatores de Tempo , Recidiva
8.
J Cardiovasc Electrophysiol ; 35(7): 1360-1367, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38715310

RESUMO

INTRODUCTION: Numerous P-wave indices have been explored as biomarkers to assess atrial fibrillation (AF) risk and the impact of therapy with variable success. OBJECTIVE: We investigated the utility of P-wave alternans (PWA) to track the effects of pulmonary vein isolation (PVI) and to predict atrial arrhythmia recurrence. METHODS: This medical records study included patients who underwent PVI for AF ablation at our institution, along with 20 control subjects without AF or overt cardiovascular disease. PWA was assessed using novel artificial intelligence-enabled modified moving average (AI-MMA) algorithms. PWA was monitored from the 12-lead ECG at ~1 h before and ~16 h after PVI (n = 45) and at the 4- to 17-week clinically indicated follow-up visit (n = 30). The arrhythmia follow-up period was 955 ± 112 days. RESULTS: PVI acutely reduced PWA by 48%-63% (p < .05) to control ranges in leads II, III, aVF, the leads with the greatest sensitivity in monitoring PWA. Pre-ablation PWA was ~6 µV and decreased to ~3 µV following ablation. Patients who exhibited a rebound in PWA to pre-ablation levels at 4- to 17-week follow-up (p < .01) experienced recurrent atrial arrhythmias, whereas patients whose PWA remained reduced (p = .85) did not, resulting in a significant difference (p < .001) at follow-up. The AUC for PWA's prediction of first recurrence of atrial arrhythmia was 0.81 (p < .01) with 88% sensitivity and 82% specificity. Kaplan-Meier analysis estimated atrial arrhythmia-free survival (p < .01) with an adjusted hazard ratio of 3.4 (95% CI: 1.47-5.24, p < .02). CONCLUSION: A rebound in PWA to pre-ablation levels detected by AI-MMA in the 12-lead ECG at standard clinical follow-up predicts atrial arrhythmia recurrence.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Eletrocardiografia , Frequência Cardíaca , Valor Preditivo dos Testes , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos , Estudos de Casos e Controles
9.
J Cardiovasc Electrophysiol ; 35(8): 1624-1632, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38898656

RESUMO

INTRODUCTION: A hybrid convergent approach (endocardial and epicardial ablation) demonstrated superior effectiveness in a recent randomized study for long-standing persistent atrial fibrillation (LSPAF). Yet, there is a lack of real-world, long-term evidence as to which patients are best candidates for a hybrid convergent approach compared to standard endocardial cryoballoon pulmonary vein isolation (CB PVI). METHODS AND RESULTS: This single-center, retrospective analysis spanning from 2010 to 2015 compared two distinctly different atrial fibrillation (AF) cohorts; one treated with stand-alone cryoablation and one treated with a hybrid convergent approach. Baseline characteristics described candidates for each approach. The following criteria were utilized to determine CB PVI candidacy: (1) paroxysmal AF (PAF) (stage 3A) with failed class I/III antiarrhythmic drug (AAD) or (2) persistent/LSPAF (stage 3B/3C/3D) with failed class I/III AAD unwilling to undergo hybrid procedure. Selection criteria for the hybrid procedure included: (1) PAF refractory to both class I/III AAD and prior CB PVI (stage 3D) or (2) persistent/LSPAF (stage 3B/3C/3D) with failed class I/III AAD agreeable to hybrid procedure. Prior sternotomy was excluded. Serial electrocardiograms and continuous monitoring evaluated primary efficacy outcome of time-to-first recurrence of atrial arrhythmia after a 90-day blanking period. Secondary outcomes were procedure-related complications and AAD use (at discharge, 12, and 36 months). Kaplan-Meier methods evaluated arrhythmia recurrence. Of 276 patients, 197 (64.2 ± 10.6 years old; 66.5% male; 74.1% 3A-PAF; 18.3% 3B/3D-persistent AF; 1.0% 3C-LSPAF; 6.6% undetermined) underwent CB PVI and 79 (61.4 ± 8.1 years old; 83.5% male; 41.8% 3D-PAF; 45.5% 3B/3D-persistent AF; 12.7% 3C/3D-LSPAF) underwent hybrid procedure. Arrhythmia freedom through 36 months was 55.2% for CB PVI and 50.4% for hybrid (p = .32). Class I AAD utilization at discharge occurred in 38 (19.3%) patients in the CB PVI group and 5 (6.3%) patients in the hybrid group (p = .01). CB PVI class I AAD utilization at 12 months occurred in 14 (9.0) patients versus 0 patients for hybrid convergent (p = .004). Patients with one or more adverse event were as follows: two (1.0%) in the CB PVI group (both transient phrenic nerve palsy) and three (3.7%) in the hybrid group (two with significant bleeding and one with wound infection) (p = .14). CONCLUSION: This study demonstrated that patients with more complex forms of AF (3D-PAF or 3B/3C/3D-persistent/LSPAF) could be well managed with a convergent approach. In a real-world evaluation, outcomes match safety and efficacy thresholds achieved for patients with earlier, less complex AF etiologies treated by CB PVI alone.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Fatores de Tempo , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Fatores de Risco , Resultado do Tratamento , Frequência Cardíaca , Tomada de Decisão Clínica , Intervalo Livre de Progressão
10.
J Cardiovasc Electrophysiol ; 35(6): 1150-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566579

RESUMO

INTRODUCTION: Proactive esophageal cooling has been FDA cleared to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures. Data suggest that procedure times for RF pulmonary vein isolation (PVI) also decrease when proactive esophageal cooling is employed instead of luminal esophageal temperature (LET) monitoring. Reduced procedure times may allow increased electrophysiology (EP) lab throughput. We aimed to quantify the change in EP lab throughput of PVI cases after the introduction of proactive esophageal cooling. METHODS: EP lab throughput data were obtained from three EP groups. We then compared EP lab throughput over equal time frames at each site before (pre-adoption) and after (post-adoption) the adoption of proactive esophageal cooling. RESULTS: Over the time frame of the study, a total of 2498 PVIs were performed over a combined 74 months, with cooling adopted in September 2021, November 2021, and March 2022 at each respective site. In the pre-adoption time frame, 1026 PVIs were performed using a combination of LET monitoring with the addition of esophageal deviation when deemed necessary by the operator. In the post-adoption time frame, 1472 PVIs were performed using exclusively proactive esophageal cooling, representing a mean 43% increase in throughput (p < .0001), despite the loss of two operators during the post-adoption time frame. CONCLUSION: Adoption of proactive esophageal cooling during PVI ablation procedures is associated with a significant increase in EP lab throughput, even after a reduction in total number of operating physicians in the post-adoption group.


Assuntos
Ablação por Cateter , Esôfago , Veias Pulmonares , Humanos , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Resultado do Tratamento , Hipotermia Induzida , Fatores de Risco , Duração da Cirurgia , Técnicas Eletrofisiológicas Cardíacas , Fluxo de Trabalho , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino
11.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
12.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38556747

RESUMO

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Assuntos
Fibrilação Atrial , Criocirurgia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Átrios do Coração/cirurgia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Potenciais de Ação , Frequência Cardíaca , Fatores de Tempo , Estudos Retrospectivos , Recidiva , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
13.
J Cardiovasc Electrophysiol ; 35(8): 1614-1623, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38890808

RESUMO

INTRODUCTION: The impact of early recurrence of atrial tachyarrhythmia (ERAT) within the 90-day blanking period on long-term outcomes in atrial fibrillation (AF) patients undergoing cryoballoon ablation (CBA) is controversial. This study aimed to assess the relationship between ERAT and late recurrence of atrial tachyarrhythmia (LRAT) post-CBA. METHODS: Utilizing data from a multicenter registry in Korea (May 2018 to June 2022), we analyzed the presence and timing of ERAT (<30, 30-60, and 60-90 days) and its association with LRAT risk after CBA. LRAT was defined as any recurrence of AF, atrial flutter, or atrial tachycardia lasting more than 30 s beyond the 90 days. RESULTS: Out of 2636 patients, 745 (28.2%) experienced ERAT post-CBA. Over an average follow-up period of 21.2 ± 10.3 months, LRAT was observed in 874 (33.1%) patients. Patients with ERAT had significantly lower 1-year LRAT freedom compared to those without ERAT (42.6% vs. 85.5%, p < .001). Multivariate analysis identified ERAT as a potential predictor of LRAT, with a hazard ratio (HR) of 3.98 (95% confidence interval [CI], 3.47-4.57). Significant associations were noted across all examined time frames (HR, 3.84; 95% CI, 3.32-4.45 in <30 days, HR, 5.53; 95% CI, 4.13-7.42 in 30-60 days, and HR, 4.29; 95% CI, 3.12-5.89 in 60-90 days). This finding was consistently observed across all types of AF. CONCLUSION: ERAT during the 90-day blanking period strongly predicts LRAT in AF patients undergoing CBA, indicating a need to reconsider the clinical significance of this period.


Assuntos
Fibrilação Atrial , Criocirurgia , Frequência Cardíaca , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Criocirurgia/efeitos adversos , Pessoa de Meia-Idade , Fatores de Tempo , Idoso , Fatores de Risco , República da Coreia/epidemiologia , Medição de Risco , Estudos Retrospectivos , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/etiologia , Potenciais de Ação , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
14.
J Cardiovasc Electrophysiol ; 35(8): 1589-1600, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38837477

RESUMO

INTRODUCTION: The underlying risks of asymptomatic embolization during high-power short-duration (HPSD) ablation for atrial fibrillation remain unclear. We aimed to evaluate microembolic signals (MESs) during HPSD ablation with power settings of 50 and 90 W in comparison with those during cryoballoon (CB) ablation using a novel carotid ultrasound-Doppler system that classifies solid and air bubble signals using real-time monitoring. METHODS AND RESULTS: Forty-seven patients underwent HPSD ablation using radiofrequency (RF), and 13 underwent CB ablation. MESs were evaluated using a novel pastable soft ultrasound probe equipped with a carotid ultrasound during pulmonary vein isolation. We compared the detailed MESs and their timing between RF and CB ablations. The number of MESs and solid signals were significantly higher in the RF group than in CB group (209 ± 229 vs. 79 ± 32, p = .047, and 83 ± 89 vs. 28 ± 17, p = .032, respectively). In RF ablation, the number of MESs, solid, and bubble signals per ablation point, or per second, was significantly higher at 90 W than at 50 W ablation. The MESs, solid, and bubble signals were detected more frequently in the bottom and anterior walls of the left pulmonary vein (LPV) ablation. In contrast, many MESs were observed before the first CB application and decreased chronologically as the procedure progressed. Signals were more prevalent during the CB interval rather than during the freezing time. Among the 28 patients, 4 exhibited a high-intensity area on postbrain magnetic resonance imaging (MRI). The MRI-positive group showed a trend of larger signal sizes than did the MRI-negative group. CONCLUSION: The number of MESs was higher in the HPSD RF group than in the CB group, with this risk being more pronounced in the 90 W ablation group. The primary detection site was the anterior wall of the LPV in RF and the first interval in CB ablation.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Valor Preditivo dos Testes , Fatores de Risco , Ultrassonografia Doppler , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Estudos Retrospectivos , Doenças Assintomáticas , Ultrassonografia das Artérias Carótidas
15.
J Cardiovasc Electrophysiol ; 35(6): 1140-1149, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38561951

RESUMO

INTRODUCTION: The presence of low-voltage zones (LVZs) in the left atrium (LA) is associated with the recurrence of atrial fibrillation (AF) following pulmonary vein isolation (PVI). However, there is variability and conflict in the data regarding predictors of LVZs as reported in previous studies. The objective of this study was to identify predictors for the presence of LVZs in a cohort of patients with persistent AF. METHODS: The study prospectively enrolled 439 patients with persistent AF who were scheduled for ablation. Voltage map of the LA was collected using a multipolar catheter. An LVZ was defined as an area of ≥3 cm2 exhibiting a peak-to-peak bipolar voltage of <0.5 mV. RESULTS: The mean age of the cohort was 65.3 ± 8.6 years and 26.4% were female. Additionally, 25.7% had significant LVZs, most frequently located in the anterior wall of the LA. Multivariable analysis identified the following independent predictors for LVZ: advanced age (OR [odds ratio] = 1.08, 95% CI [confidence interval] = 1.03-1.13, p = .002); female sex (OR = 4.83, 95% CI = 2.66-8.76, p < .001); coronary artery disease (CAD) (OR = 3.20, 95% CI = 1.32-7.77, p = .01) and enlarged LA diameter (OR = 1.10, 95% CI = 1.04-1.17, p = .001). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve for the final model was 0.829. CONCLUSION: Approximately 25% of the patients with persistent AF had LVZs. Advanced age, female sex, CAD, and a larger LA were independent predictors for LVZs with the model demonstrating a very good AUC for the ROC curve. These findings hold the potential to be used to tailor the ablation procedure for the individual patient.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Valor Preditivo dos Testes , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Medição de Risco , Fatores Sexuais , Fatores de Tempo , Fatores Etários
16.
J Cardiovasc Electrophysiol ; 35(7): 1471-1479, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38803006

RESUMO

INTRODUCTION: According to current guidelines, pulmonary vein isolation as first-line therapy should be considered for patients with atrial fibrillation (AF), however, optimal timing of the procedure is still unknown in patients with heart failure (HF). We aimed to evaluate the effect of early catheter ablation (CA) in patients with HF and left ventricular ejection fraction (LVEF) below 50%. METHODS: We analyzed data from a structured registry comprising 227 patients with paroxysmal or persistent AF and HF with LVEF < 50% who underwent radiofrequency CA between 2015 and 2022. Early CA was defined as a procedure performed within 12 months of AF diagnosis. The median follow-up duration was 1748 (1176.3-2353.5) days, with a minimum follow-up of 365 days. Our endpoints were AF recurrence after a 3-months blanking period and all-cause mortality. RESULTS: Among the 227 patients with a median age of 64.3 years, 97 (42.7%) experienced AF recurrence and 55 (24.2%) died during the follow-up period. The median LVEF was 40% for early CA and 38% for delayed CA (p = .053). Early CA significantly reduced AF recurrence (HR = 0.25 [0.15-0.42], p < .001), however, the timing of procedure did not affect all-cause mortality (p = .16). These findings were consistent regardless of AF subtype or the burden of comorbidities, as assessed by the CHA2DS2-VASc score. CONCLUSION: The timing of CA of AF appears to be an important factor in patients with HF. Early CA reduced AF recurrence, although it does not impact all-cause mortality. We found similar results regardless of AF subtype or burden of comorbidities.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Recidiva , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Masculino , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Fatores de Risco , Resultado do Tratamento , Tempo para o Tratamento , Potenciais de Ação , Estudos Retrospectivos , Frequência Cardíaca , Medição de Risco , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
17.
J Cardiovasc Electrophysiol ; 35(8): 1525-1535, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38803029

RESUMO

INTRODUCTION: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long-term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter. METHODS: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long-term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24-h Holter ECGs at 3, 6, and 12 months postablation; and 12-lead ECGs recorded during symptomatic episodes or visits. RESULTS: Half of the patients had ls-PerAF, and half had a history of catheter ablation-mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low-voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow-up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months. CONCLUSION: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Fatores de Risco , Sistema de Registros , Estudos de Viabilidade , Resultado do Tratamento , Intervalo Livre de Progressão , Flutter Atrial/cirurgia , Flutter Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Cateteres Cardíacos
18.
J Vasc Interv Radiol ; 35(8): 1148-1153, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38692392

RESUMO

PURPOSE: To evaluate the correlation between pulmonary hypertension (PH) and recurrence of pulmonary arteriovenous malformation (PAVM) after embolization. MATERIALS AND METHODS: With institutional review board (IRB) approval, the records of 377 patients with PAVMs evaluated at a single hereditary hemorrhagic telangiectasia (HHT) center of excellence between January 1, 2013, and September 10, 2023, were retrospectively reviewed. PAVMs embolized during this time period were evaluated for recurrence. Patients and PAVMs not treated during this time period were excluded. Growth of previously untreated PAVMs was not considered recurrence. Patients without chest computed tomography (CT) follow-up were excluded. General demographics, HHT status as defined by genetic testing or Curacao criteria, presence of PH, history of smoking, anemia, and hepatic arteriovenous malformations (AVMs) were documented. Odds ratio (OR) was calculated and stratified analysis was performed to assay the correlation between PAVM recurrence, PH, and possible confounders. RESULTS: A total of 151 patients with PAVMs were treated during the study period, including 438 PAVMs, for which follow-up was available. This included 106 patients with definite, 31 with doubtful, and 14 with possible HHT. The presence of PH was significantly associated with PAVM recurrence both by patient (OR, 8.13; 95% CI, 3.50-19.67) and by lesion (OR, 4.07; 95% CI, 2.14-7.91). Multivariate analysis demonstrated that this correlation was independent of several variables including HHT status, smoking history, presence of hepatic AVMs, and anemia. CONCLUSIONS: There is a high correlation between PH and PAVM recurrence, suspected to be due to high pulmonary artery pressures causing recanalization. PH may suggest the need for shorter surveillance intervals.


Assuntos
Malformações Arteriovenosas , Embolização Terapêutica , Hipertensão Pulmonar , Artéria Pulmonar , Veias Pulmonares , Recidiva , Humanos , Feminino , Masculino , Artéria Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Embolização Terapêutica/efeitos adversos , Pessoa de Meia-Idade , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Resultado do Tratamento , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Adulto , Malformações Arteriovenosas/terapia , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/complicações , Fatores de Risco , Fatores de Tempo , Idoso , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/diagnóstico por imagem , Telangiectasia Hemorrágica Hereditária/terapia , Adulto Jovem , Pressão Arterial
19.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38767127

RESUMO

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Assuntos
Criocirurgia , Veias Pulmonares , Criocirurgia/métodos , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Animais , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Suínos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirurgia , Modelos Anatômicos
20.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607938

RESUMO

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Sistema de Registros , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Suíça/epidemiologia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA