Noninvasive calibration of cardiac pressure transducers in patients with heart failure: an aid to implantable hemodynamic monitoring and therapeutic guidance.
McClean, Dougal; Aragon, Joseph; Jamali, Aamer; Kar, Saibal; Ritzema-Carter, Jay; Troughton, Richard; Krum, Henry; Doughty, Robert; Abraham, William T; Whiting, James S; Eigler, Neal.
Afiliação
  • McClean D; Division of Cardiology, Department of Medicine, and the Research Institute at Cedars-Sinai Medical Center, Los Angeles, California, USA.
J Card Fail ; 12(7): 568-76, 2006 Sep.
Article em En | MEDLINE | ID: mdl-16952791
ABSTRACT

BACKGROUND:

Implantable cardiac pressure monitors require assurance of calibration. This study evaluated if airway pressure responses during Valsalva maneuver (VM) can be used for calibrating intracardiac pressure transducers. METHODS AND

RESULTS:

Thirty-eight heart failure patients performed VMs while cardiac and airway pressures were recorded. Patients were designated as Lower (L) if baseline PCW was <20 mm Hg (n = 17); otherwise, they were categorized as Higher (H) (n = 21). VMs were repeated in 9 H patients after nitroglycerin. Procedural success was 92% and there were no complications. Differences between filling pressure and airway pressure (effective pressure) were eliminated during VM (RA(eff) = -0.9 +/- 1.3, RVED(eff) = 1.2 +/- 1.1, PCW(eff) = 2.1 +/- 2.8, and LVED(eff) = 0.9 +/- 1.6 mm Hg), and filling pressures were highly correlated with airway pressure r = 0.94. On average, group H had higher PCW(eff) and LVED(eff) than L patients by 1.8 and 2.5 mm Hg (P < or = .002), respectively, but after nitrates their responses were identical.

CONCLUSION:

The relationships between cardiac filling pressure and airway pressure during the Valsalva maneuver are sufficiently reliable to be considered as a new, noninvasive method for establishing the calibration of cardiac pressure sensors in patients with heart failure.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores de Pressão / Pressão Sanguínea / Circulação Coronária / Coração / Insuficiência Cardíaca Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Card Fail Assunto da revista: CARDIOLOGIA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores de Pressão / Pressão Sanguínea / Circulação Coronária / Coração / Insuficiência Cardíaca Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Card Fail Assunto da revista: CARDIOLOGIA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos