Your browser doesn't support javascript.
loading
Detection and characterization of hepatocellular carcinoma in rats with liver cirrhosis: diagnostic value of combined use of MR positive and negative contrast agents.
Guo, Dong-Mei; Qiu, Tian-Shuang; Bian, Jie; Liu, Shu-Feng; Wang, Chang-Zheng.
Afiliação
  • Guo DM; Department of Electronic Engineering, Dalian University of Technology, Dalian 116024, China.
Hepatobiliary Pancreat Dis Int ; 8(1): 65-70, 2009 Feb.
Article em En | MEDLINE | ID: mdl-19208518
BACKGROUND: Gadolinium-enhanced multi-phase dynamic imaging has improved the accuracy of the diagnosis of hypervascular hepatocellular carcinoma (HCC), but using gadolinium-enhanced dynamic imaging alone is problematic in evaluating hypovascular HCC. This work aimed at evaluating the combined use of superparamagnetic iron oxide (SPIO)-enhanced and gadolinium set in distinguishing HCCs from regenerative nodules (RNs) in a rat model induced by diethylnitrosamine (DEN). METHODS: DEN-induced HCC model rats (n=40) and control rats (n=10) were studied. From weeks 16 to 19 after DEN administration, 4 animals were scanned every week. The hepatic changes were tested with a 1.5 Tesla magnet, and MR images of SPIO-enhanced and gadolinium set were obtained. According to the pathologic changes, the tumorigenesis was divided into HCC and RN (diameter of nodules > or =3 mm). Diagnostic accuracy of the combined SPIO-enhanced and gadolinium set and the gadolinium set alone was evaluated using receiver-operating characteristic curves. Sensitivity and specificity of the combined SPIO-enhanced and gadolinium set and the gadolinium set alone were calculated. RESULTS: The listed tests were completed in 29 rats (21 treated and 8 controls). One hundred and six nodules (82 HCCs, 24 RNs) were analyzed. The Az value and sensitivity with the combined SPIO-enhanced and gadolinium set (Az 0.94, sensitivity 0.96) were higher than those with the gadolinium set alone (Az 0.92, sensitivity 0.89). Using the combined SPIO-enhanced and gadolinium set led to detection of 6 nodules which were negative in the gadolinium set alone and 3 nodules were correctly characterized. CONCLUSION: Using the combined SPIO-enhanced and gadolinium set improved the detectability of HCCs and the SPIO-enhanced imaging compensated for the gadolinium set in differentiating HCCs from RNs in a rat model.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Carcinoma Hepatocelular / Meios de Contraste / Cirrose Hepática / Neoplasias Hepáticas Experimentais Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Hepatobiliary Pancreat Dis Int Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Carcinoma Hepatocelular / Meios de Contraste / Cirrose Hepática / Neoplasias Hepáticas Experimentais Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Hepatobiliary Pancreat Dis Int Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: China