Your browser doesn't support javascript.
loading
Buoyancy-corrected gravimetric analysis of lightly loaded filters.
Rasmussen, Pat E; Gardner, H David; Niu, Jianjun.
Afiliação
  • Rasmussen PE; Exposures and Biomonitoring Division, Environmental Health Science and Research Bureau, Health Canada, Ottawa, Ontario, Canada. pat.rasmussen@hc-sc.gc.ca
J Air Waste Manag Assoc ; 60(9): 1065-77, 2010 Sep.
Article em En | MEDLINE | ID: mdl-20863052
ABSTRACT
Numerous sources of uncertainty are associated with the gravimetric analysis of lightly loaded air filter samples (< 100 microg). The purpose of the study presented here is to investigate the effectiveness and limitations of air buoyancy corrections over experimentally adjusted conditions of temperature (21-25 degrees C) and relative humidity (RH) (16-60% RH). Conditioning (24 hr) and weighing were performed inside the Archimedes M3 environmentally controlled chamber. The measurements were performed using 20 size-fractionated samples of resuspended house dust loaded onto Teflo (PTFE) filters using a Micro-Orifice Uniform Deposit Impactor representing a wide range of mass loading (7.2-3130 microg) and cut sizes (0.056-9.9 microm). By maintaining tight controls on humidity (within 0.5% RH of control setting) throughout pre- and postweighing at each stepwise increase in RH, it was possible to quantify error due to water absorption 45% of the total mass change due to water absorption occurred between 16 and 50% RH, and 55% occurred between 50 and 60% RH. The buoyancy corrections ranged from -3.5 to +5.8 microg in magnitude and improved relative standard deviation (RSD) from 21.3% (uncorrected) to 5.6% (corrected) for a 7.2 microg sample. It is recommended that protocols for weighing low-mass particle samples (e.g., nanoparticle samples) should include buoyancy corrections and tight temperature/humidity controls. In some cases, conditioning times longer than 24 hr may be warranted.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Poluentes Atmosféricos / Filtração Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Air Waste Manag Assoc Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Canadá
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Poluentes Atmosféricos / Filtração Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Air Waste Manag Assoc Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Canadá