A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects.
Dave, Meetal; Davies, Jonathan; Wilson, Ron; Palmer, Richard.
Afiliação
  • Dave M; Department of Restorative Dentistry, King's College London Dental Institute, Tower Wing, Guy's Hospital Campus, London, SE1 9RT, UK.
Clin Oral Implants Res ; 24(6): 671-8, 2013 Jun.
Article em En | MEDLINE | ID: mdl-22458628
ABSTRACT

OBJECTIVE:

To compare the diagnostic accuracy of conventional periapical radiography and cone beam computed tomography (CBCT) at detecting peri-implant bone defects. MATERIALS AND

METHODS:

Implants were placed in fresh bovine ribs in osteotomy sites of varying diameter (five with no peri-implant space, five with a 0.35 mm space, five with a 0.675 mm space) and imaged using (i) digital long cone periapical radiographs (LCPAs), (ii) limited volume CBCT using 3D Accuitomo 80(®) and (iii) large volume CBCT using i-CAT Next Generation(®). Images from each were randomly presented to nine examiners on two occasions. Confidence in diagnosing the presence or absence of a peri-implant radiolucency was recorded on a five-point scale. Receiver Operating Characteristic (ROC) analysis and Kappa tests were performed.

RESULTS:

Digital LCPAs were better at diagnosing a peri-implant bone defect when the peri-implant space was 0.35 mm (P < 0.02). As the peri-implant space increased to 0.675 mm, there was no significant difference in diagnostic accuracy between the three imaging methods. Sensitivity of LCPAs (100) and Accuitomo (97.8) was better than i-CAT (64.4) (P < 0.02). LCPAs and i-CAT had significantly better specificity and positive predictive value than Accuitomo. The negative predictive value of LCPA was significantly better than i-CAT. LCPAs showed better intra-examiner and inter-examiner agreement than CBCT.

CONCLUSION:

Within the limitations of this study, LCPAs are a reliable and valid method of detecting circumferential peri-implant bone defects and performed significantly better than CBCT.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Costelas / Implantes Dentários / Radiografia Dentária Digital / Implantação Dentária Endóssea / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Costelas / Implantes Dentários / Radiografia Dentária Digital / Implantação Dentária Endóssea / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Reino Unido