Development and evaluation of an affordable real-time qualitative assay for determining HIV-1 virological failure in plasma and dried blood spots.
Aitken, Susan C; Kliphuis, Aletta; Bronze, Michelle; Wallis, Carole L; Kityo, Cissy; Balinda, Sheila; Stevens, Wendy; Spieker, Nicole; de Oliveira, Tulio; Rinke de Wit, Tobias F; Schuurman, Rob.
Afiliação
  • Aitken SC; University Medical Centre Utrecht, Utrecht, the Netherlands. s.c.aitken@umcutrecht.nl
J Clin Microbiol ; 51(6): 1899-905, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23596235
ABSTRACT
Virological failure (VF) has been identified as the earliest, most predictive determinant of HIV-1 antiretroviral treatment (ART) failure. Due to the high cost and complexity of virological monitoring, VF assays are rarely performed in resource-limited settings (RLS). Rather, ART failure is determined by clinical monitoring and to a large extent immunological monitoring. This paper describes the development and evaluation of a low-cost, dried blood spot (DBS)-compatible qualitative assay to determine VF, in accordance with current WHO guideline recommendations for therapy switching in RLS. The assay described here is an internally controlled qualitative real-time PCR targeting the conserved long terminal repeat domain of HIV-1. This assay was applied to HIV-1 subtypes A to H and further evaluated on HIV-1 clinical plasma samples from South Africa (n = 191) and Tanzania (n = 42). Field evaluation was performed in Uganda using local clinical plasma samples (n = 176). Furthermore, assay performance was evaluated for DBS. This assay is able to identify VF for all major HIV-1 group M subtypes with equal specificity and has a lower detection limit of 1.00E+03 copies/ml for plasma samples and 5.00E+03 copies/ml for DBS. Comparative testing yielded accurate VF determination for therapy switching in 89% to 96% of samples compared to gold standards. The assay is robust and flexible, allowing for "open platform" applications and producing results comparable to those of commercial assays. Assay design enables application in laboratories that can accommodate real-time PCR equipment, allowing decentralization of testing to some extent. Compatibility with DBS extends access of sampling and thus access to this test to remote settings.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Manejo de Espécimes / Sangue / Infecções por HIV / HIV-1 / Carga Viral / Dessecação / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Qualitative_research Limite: Humans País/Região como assunto: Africa Idioma: En Revista: J Clin Microbiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Manejo de Espécimes / Sangue / Infecções por HIV / HIV-1 / Carga Viral / Dessecação / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Qualitative_research Limite: Humans País/Região como assunto: Africa Idioma: En Revista: J Clin Microbiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Holanda